Post by petrus on Redundancy Codesys Runtime, Synchronization
CODESYS Forge
talk
(Post)
Hello, Has anyone figured out the Standalone issue after a network break? I have the similar behavior with two 750-8212 WAGO controllers. Using firmware 27 and CODESYS 3.5.19.70.
Last updated: 2024-08-22
Post by tomw on Soft Motion - PosControl External Encoder
CODESYS Forge
talk
(Post)
I need to understand how an external encoder ties into the SM_Drive_PosControl setup. I have an application where I have two hydraulic servo amplifiers. The encoder is a Temposonic Linear SSI encoder. How does the encoder get tied back into the SM_Drive_PosControl axis. Thanks.
Last updated: 2025-05-13
Post by s1mon on Two OneWireMaster on one Raspberry PI 5
CODESYS Forge
talk
(Post)
Thx for the hint. It works if I add following line to the .cfg file. PlaceholderFilePath.2=/sys/devices/w1_bus_master2, $OneWire2$ Is there a documentation how to modify this config file? Will this be overwritten if I do an update of the CodesysControl Runtime?
Last updated: 2025-06-13
Post by llewv123 on Bullseye and Waveshare 2-CH CAN FD HAT rev2.1 with two slaves
CODESYS Forge
talk
(Post)
Hi David, I am trying to use a Waveshare AD/DA hat for RPi in CodeSYS control for RPi, and have no idea as to where to start. Perhpas you've cracked this above? Any help appreciated!
Last updated: 2025-08-04
Post by lipton on Safety Cross-communication with network variables
CODESYS Forge
talk
(Post)
I am currently engaged in research for a Codesys project that involves the establishment of communication between two or more Codesys safety controllers using safe communication protocols, would it be possibole ? /Best Regards
Last updated: 2023-12-29
Post by cavein on PFC100 Licensing fails
CODESYS Forge
talk
(Post)
Hi, i have a similar problem. im using pfc200 4.5.0.0. There are two softcontainer and only one with license in it. every 1-2 hrs it will auto logoff. i tried the steps above but i dont find the /var/opt/codesys/.cmact_licenses i need help please.
Last updated: 2024-03-19
Post by abjha1998 on Codesys v3.5 Sint to byte
CODESYS Forge
talk
(Post)
Hi everyone, I have been doing a project where I have to send CAN messages from WAGO plc pf200 in BYtes. The signed integer needs to be unpacked into two bytes. so far I have tried Union but that has not worked with me
Last updated: 2024-04-22
Post by arrotek on Codesys HMI Redundancy
CODESYS Forge
talk
(Post)
Is there a way to run Codesys HMI on two different PC's and have the web visu clients fail over to the HMI instance that is wokring or running?
Last updated: 2024-05-30
Post by mahmutbeyaz on Create a Motion Profile
CODESYS Forge
talk
(Post)
Dear All, I hope first to get notice and somebody answer my question. How can I create a motion profile with the axis following it (once or periodically)? As my research shows, Schineder has a UI-based (Motion Sizer) program that helps create a motion with different configurations, which is Codesys-based. I need to create a motion profile based on position, changing the speed. (i.e., 0-300mm moves with 300 mm/s, 300-400mm moves with 500 mm/s, 500-800mm moves with 1000 mm/s, and 800-0mm moves with 2000 mm/s). MC_PositionProfile does it time-based, which is not working for me as the axis may not stabilize the position in time, which may cause a big failure in the system.
Last updated: 2023-11-30
Post by teichhei on The selected container ... does not fit your ticket
CODESYS Forge
talk
(Post)
Hi, When trying to activate a control Basic L license on a Wago PFC200 750-8203 the error The selected container ... does not fit your ticket comes up and won't allow licensing. I have deleted the /var/opt/codesys/cmact_license/ content 3 times and the container number changed each time after a reboot, but the problem persists. Not a happy first time experience with those weird application based licenses. IDE is 19.20. This was a e!Cockpit FW22 PLC and I used Deploy Control SL to make the green web interface red. WBM shows Codesys 2 and e!Runtime active which is a bit weird. What do I do now? Regards Heinz
Last updated: 2025-01-08
Post by reinier-geers on License problem gateway
CODESYS Forge
talk
(Post)
16.4 Epis What has it to do with the manufacture? It just a licence more not. So basicly the idee of codesys sucks. 3s acts like its posible to add a license. And then it depence on the manufacturer. Why ?? Its a computer !! has nothing to do with the manufacturer. Most dont what a basic licence because they have to pay for that. 3s is the problem not the manufacture of the hardware. Its like the licence of the raspberry pi. HMI is not working. Sorry you get a refund. Why suggest that its possible wen its not !!. It cost me a lot of time. Who pays my time. Why do i have to pay for somting thats not working.
Last updated: 2024-04-26
Post by damian177 on Codesys and SMS in RPi
CODESYS Forge
talk
(Post)
I tried initialize my GSM modem by write simple application in C, and GSM modem works, below used AT commands: AtChat: T : "AT" AtChat: F : "OK" AtChat: T : "AT+CMEE=1" AtChat: F : "OK" AtChat: T : "AT+CMGF=0" AtChat: F : "OK" AtChat: T : "AT+CGMI" AtChat: F : "WH_Ltd" AtChat: F : "WH_GM35" AtChat: F : "Revision: RDA BV5" AtChat: F : "OK" AtChat: T : "AT+CGMM" AtChat: F : "WH_GM35" AtChat: F : "OK" AtChat: T : "AT+CGMR" AtChat: F : "Revision: GM35-D_B5_R05_A01_D170914" AtChat: F : "OK" AtChat: T : "AT+CGSN" AtChat: F : "868221045990218" AtChat: F : "OK" AtChat: T : "AT+CNMI=2,1,0,1,0" AtChat: F : "OK" AtChat: T : "AT+CLIP=1" AtChat: F : "OK" AtChat: T : "AT+COPS?" AtChat: F : "+COPS: 0,2,\"26002\"" AtChat: F : "OK" operator name: "26002" AtChat: T : "AT+CREG?" AtChat: F : "+CREG: 1,1" AtChat: F : "OK" at+creg Modem is initialized I do not understand why Codesys SMS library send AT+CPIN? command ?
Last updated: 2023-09-29
Post by ivan-g on MODBUS
CODESYS Forge
talk
(Post)
Hi There, I took over a project from a colleague (in GTB) who left the company. When I took over his project, it wouldn't compile because some libraries were missing. I managed to recover quite a few libraries, but I can't find the library that contains the block functions shown in the image. Here are a few examples: Fb_RegMel_ISO Fb_DefModbus FbDecalConsSalSO Fb_Autor_FreeCool_CTA_C I'm a little stuck at the moment, so if you see a Facebook post that speaks to you, don't hesitate to get in touch! Thank you in advance for your help.
Last updated: 2025-08-05
Post by ivan-g on MODBUS
CODESYS Forge
talk
(Post)
Hi There, I took over a project from a colleague (in GTB) who left the company. When I took over his project, it wouldn't compile because some libraries were missing. I managed to recover quite a few libraries, but I can't find the library that contains the block functions shown in the image. Here are a few examples: Fb_RegMel_ISO Fb_DefModbus FbDecalConsSalSO Fb_Autor_FreeCool_CTA_C I'm a little stuck at the moment, so if you see a FB that speaks to you, don't hesitate to get in touch! Thank you in advance for your help.
Last updated: 2025-08-05
Post by jzhvymetal77 on Special Chars in Visualizationfor QR code string
CODESYS Forge
talk
(Post)
In Visualization, is there any way to make special characters in a string display properly in a Text object? I wrote a function block to create QR codes at runtime. My code uses β$DB,β which in ASCII should render as a solid block. The code works, but to display it in Visualization I had to create multiple rectangles with visibility bound to a BOOL array. That works, but since each BOOL must be exposed as a separate variable, it consumes most of the available monitoring resources. See Attached image.
Last updated: 2025-09-29
Post by jzhvymetal77 on Special Chars in Visualizationfor QR code string
CODESYS Forge
talk
(Post)
In Visualization, is there any way to make special characters in a string display properly in a Text object? I wrote a function block to create QR codes at runtime. My code uses β$DB,β which in ASCII should render as a solid block. The code works, but to display it in Visualization I had to create multiple rectangles with visibility bound to a BOOL array. That works, but since each BOOL must be exposed as a separate variable, it consumes most of the available monitoring resources. See Attached image.
Last updated: 2025-09-29
Post by stuartjr on Disabling forcing of specific variables
CODESYS Forge
talk
(Post)
Is there a way that I can create a variable in a GVL that I can control with logic but a user can not put a force on this variable. I have looked at the access rights but this seems to only limit editing the GVL or POU. This variable will only be assigned a value in one POU but it will be used throughout many other POUs.
Last updated: 2024-03-15
Post by arcadium on TargetVisu element stacking on top of each other
CODESYS Forge
talk
(Post)
Hello, I'm new here so if I do something wrong please bare with me. I am using raspberry pi touchscreen made by comfile (CPi-C070WR4C). I also have a window 11 pc where I would like to have a second visualisation, but when I run a TargetVisu with it, all elements of the visualisation end up in the top left corner stacked on top of each other. I have same results running targetVisu on my laptop. Maybe someone had same issues and know the solution? Simas
Last updated: 2024-06-17
Post by toffeebonbon on EL7041-0052 - does it run with EL7041 SoftMotion?
CODESYS Forge
talk
(Post)
I let this project rest for a while and picked it up last week. I have been in contact with the support from beckhoff and got the information that the terminals were identical (communication wise). As the Log of the Axis (not the drive's log) shows the error when trying to write into the register 0x8012 and set the value for an encoder to a value that is the default - at least according to the manual - I was wondering if it is possible to "not write that value" to skip that part? Or am I misunderstanding the way the library communicates with the drive?
Last updated: 2024-07-24
Is it possible to replace a table row header for a text in a text list?
CODESYS Forge
talk
(Thread)
Is it possible to replace a table row header for a text in a text list?
Last updated: 2021-10-21
Assign a value to a variable that is defined in a string
CODESYS Forge
talk
(Thread)
Assign a value to a variable that is defined in a string
Last updated: 2023-02-13
how to execute a pointer to a function or a function block?
CODESYS Forge
talk
(Thread)
how to execute a pointer to a function or a function block?
Last updated: 2017-04-04
How can I put a delay in a st code with a for cycle?
CODESYS Forge
talk
(Thread)
How can I put a delay in a st code with a for cycle?
Last updated: 2019-11-12
Post by plunje on Sensor not set
CODESYS Forge
talk
(Post)
A got a larger project but this very small example makes it clear. I have a button, and after it's clicked a lamp should flip on and stays on, and when the mouse-button is released it should stay on. When I try that in the PLC_PRG it works, but when I change it to a function block (seet attched demo proj) it isn't. I'm fairly new to PLC programming but are very experienced C# engineer, but this goes above my head...
Last updated: 2024-05-26
Post by manuknecht on Opening a Dialog on a specific Client from ST
CODESYS Forge
talk
(Post)
I managed to find a solution that seems to work reliably. As the VU.Globals.CurrentClient-filter accesses the CURRENTCLIENTID or at least a similar, internal variable it can only be used if called from a certain client (e.g. from a button in a visualization). My solution works by implementing a new client filter that compares the client ID of all clients to the ID of the last client that was used. The variable containing the data of the last client is defined as: G_LastClient : VU.IVisualizationClient; // Copy of last client that detected click This last client is then updated every time a button is pressed using the Execute ST-Code input configuration of the button: G_LastClient := VU.PublicVariables.Clients.Current; Next, I created a function block that implements the client filter interface as so: FUNCTION_BLOCK FB_LastClientFilter IMPLEMENTS VU.IVisualizationClientFilter VAR_INPUT END_VAR VAR_OUTPUT END_VAR VAR END_VAR Then i added a method to the FB called IsAccepted which is used to filter out the client. When creating the method, it should automatically be filled with the according variable declaration, as it is defined in the interface: (* For every client can be desided, if it is accepted. ``TRUE``: Client is accepted*) METHOD IsAccepted : BOOL VAR_INPUT (* The client, to check*) itfClient : VU.IVisualizationClient; END_VAR Now the client can be compared to the last used client as such: // check if clientID corresponds to clientID of last recorderd client IF itfCLient.ClientId = G_LastClient.ClientId THEN IsAccepted := TRUE; ELSE IsAccepted := FALSE; END_IF To make use of this custom client filter, initialize a variable with the client filter: LastClient : FB_LastClientFilter; // Client filter to find last used client Then use this client filter when opening or closing a dialog from ST: fbOpenMyDialog(itfClientFilter:=LastClient,xExecute:=TRUE,sDialogName:='VIS_MyDialog_DLG');
Last updated: 2023-09-27