Post by mmpl on Array to String
CODESYS Forge
talk
(Post)
I would like to create one large JSON string from an array of objects, where each object contains a value. My current approach involves using a for loop and string concatenation, but with 20,000 elements in the array, this method takes almost 7 seconds and negatively affects the PLC scan time. Is there a more efficient way to accomplish this?
Last updated: 2024-07-18
Post by mmpl on Array to String
CODESYS Forge
talk
(Post)
I would like to create one large JSON string from an array of objects, where each object contains a value. My current approach involves using a for loop and string concatenation, but with 20,000 elements in the array, this method takes almost 7 seconds and negatively affects the PLC scan time. Is there a more efficient way to accomplish this?
Last updated: 2024-07-18
Post by fionexyan on Codesys Installation Always Freeze when the installing is almost done
CODESYS Forge
talk
(Post)
Hello Everyone , I have try in repeatedly with uninstall and reinstall the Codesys software and even turn-off the antivirus application before implement to reinstall the codesys ,but at the consequence the problem still same although go with such method, therefore is there any solution for this issue . Thank You .
Last updated: 2025-05-16
Post by blitz on Latch alarm variables from the PLC runtime
CODESYS Forge
talk
(Post)
Hi, I have a question. Does anyone know a way to change latch alarm variables from the PLC runtime? In the help there is a method described: https://content.helpme-codesys.com/en/libs/AlarmManager/Current/Interfaces/pou-IAlarm3/SetLatchVarValue.html but I don’t know how to use it correctly.
Last updated: 2025-09-23
Post by kimnegw on Codesys offline license batch
CODESYS Forge
talk
(Post)
Hey guys, I'm currently developing a Codesys application for an offline Linux device. I can easily set up the license for ONE device using my Windows PC, but what happens if I need to produce a thousand devices? Is there any method to automate license insertion? I have already generated a dpkg installer for deploying the Linux control application to multiple targets. Thanks,
Last updated: 2024-04-04
Post by corriibme on JSON Utilities and SetArray
CODESYS Forge
talk
(Post)
Hello @florian, Could you please help with how to set an array value? I've been trying to use the with the setKeyWithArray method which creates the key with an empty array value. But I have been unable to set items in this array? objindex:= fb_JBuilder.SetKeyWithArray("Key6", diParentIndex := diRootIndex); objindex2:= fb_JBuilder.SetValue(value:= iValue2, diParentIndex:= objindexx); //iValue: array[0..n] of int; Best regards
Last updated: 2024-05-11
Post by siscu on Raspberry Pi: List of available example applications
CODESYS Forge
talk
(Post)
Could this be turned into a library? I'd love for a way to have the main program call a function block method using the program's I2C_master device. I assume I should be passing the master as a variable for the function block, but I don't see how that could be achieved
Last updated: 2024-05-15
Post by dtamm on How to read string from CharBufferPtr?
CODESYS Forge
talk
(Post)
I am trying to implement a mechanism to send alarm SMS. For this, I have created an Alarm Class with a Notification Action which calls a POU. This POU implements IAlarmNotifiable making it selectable in the Alarm Class configuration. IAlarmNotifiable has an Execute method which is called by the alarm class. Now, I want to extract the alarm message of the triggered alarm. The Execute method comes with a VAR_INPUT itfAlarm: AlarmManager.IAlarm which supplies a method called GetMessage. The help text says: Returns the message text, that has been configured for the alarm. The result is a pointer to the buffer, where the message text is stored The type of the result is CharBufferPtr, and at some place I read that it can be interpreted as a pointer to string. But I cannot manage to extract the alarm message, all I get are numbers. I have tried the following: psAlarmText := itfAlarm.GetMessage(__SYSTEM.TYPE_CLASS.TYPE_STRING)^; sAlarmText := TO_STRING( itfAlarm.GetMessage(__SYSTEM.TYPE_CLASS.TYPE_STRING)^ ); So how do I get access to the alarm message as clear text? (In this case, "Larm 1")
Last updated: 2024-02-21
Post by eschwellinger on How to configure CODESYSControl_User.cfg in order to use a specific network card for OPCUA Server
CODESYS Forge
talk
(Post)
check this faq section here: https://faq.codesys.com/plugins/servlet/mobile?contentId=102137886#content/view/102137886
Last updated: 2023-08-25
Post by eschwellinger on How to configure CODESYSControl_User.cfg in order to use a specific network card for OPCUA Server
CODESYS Forge
talk
(Post)
Hi Rossano, thank you for the feedback, you are right this need to be changed in the faq section. Regards Edwin
Last updated: 2023-08-28
Post by janber0206 on RPI is license server down
CODESYS Forge
talk
(Post)
I had the same problem. Problem solved: all licences purchased before October 2022 must be updated by Codesys. To do so, simply contact the support in the Codesys Store.
Last updated: 2023-10-30
Post by hwopereis on How to use Application Trigger in Modbus TCP Server
CODESYS Forge
talk
(Post)
I'm now circumventing the problem by creating a separate TCP client for all Write actions. Upon registering a changed variable, I enable this client, until the change is processed.
Last updated: 2024-07-01
Post by reinier-geers on Syssockping hang up V3.5.9.2
CODESYS Forge
talk
(Post)
For data logging on a server i check the connection with Syssockping. When i do that it seems to hang uo the system once a while for 13 seconds. Why ??
Last updated: 2024-09-02
Post by arfoto on Gateway
CODESYS Forge
talk
(Post)
Merhaba Gateway config moda almak istediğimde BU hatayı alıyorum. maalesef bu sorunu çözemiyorum amacım softplc yi Automation Server a Bağlamak Ama maalesef config moda giremiyorum dosya yolumda C:\ProgramData\CODESYS\CODESYSGatewayV3 bu şekilde. Teşekkür ediyorum.
Last updated: 2024-09-17
Post by fmbrew-rob on Licensing info not available.
CODESYS Forge
talk
(Post)
I do have a license server installed. Can you point to a document or ANYTHING that shows how to configure this virtual control to properly do licensing?
Last updated: 2024-09-24
Post by hanpekel on Reading request counter value from modbus server in application
CODESYS Forge
talk
(Post)
Any way I can read the value of the 'request counter' (see screenshot) in my application. Amount of client connections is easily found using ModbusTCP_Slave_Device.uiClientConnections; But for request counter it does not seem to be that simple.
Last updated: 2024-10-16
Post by banialuk on Modbus TCP Server
CODESYS Forge
talk
(Post)
Hello, I have poroblem with define input in function block modbusFB.serverTCP 'dataModel', in my aplication I need starting Input Registers from 3000, and I must define this in 'data Model' but I dont now how exacly to do it. Anybody now somethin about this?
Last updated: 2024-10-19
Post by tmo21 on Automation server - trends stop recording - need to manually reconnect
CODESYS Forge
talk
(Post)
Hi Edwin, Thanks for your message. Edge controller Version: 4.4.0.0 based on 3.5.17.30 PLC version: Device Identification Name CODESYS Control for Raspberry Pi MC SL Vendor 3S - Smart Software Solutions GmbH Device type Softmotion3S Firmware version 4.4.0.0
Last updated: 2024-10-23
Post by eschwellinger on Virtual Control SL Profinet connection
CODESYS Forge
talk
(Post)
means not licensed demo mode.. use the Licenserver on the host and apply a license and add the Ip of the license server then it will be green.
Last updated: 2025-02-28
Post by vincerex on SFTP access
CODESYS Forge
talk
(Post)
hello everyone, is there a library or a way to access to SFTP server using Codesys? SysSocket library is only suitable for FTP it seems. I didn't find any other suggestion on the web Thanks for your help VinceReX
Last updated: 2025-04-01
Post by timvh on How to correctly create a device descriptor (.devdesc.xml) for a custom Linux ARM64 PLC in CODESYS 3.5.21.20?
CODESYS Forge
talk
(Post)
Yes, this is possible with the Toolkit. We only server customers in the Benelux that do this, so contact your local CODESYS distributor, or contact the sales team of CODESYS Germany.
Last updated: 2025-10-07
Post by rjwkerkhof on IIot Libraries SL --> Web Socket Client SL Pong issue
CODESYS Forge
talk
(Post)
Dear all, I am developing a Web Socket Client in Codesys 3.5 using the Web Socket Client SL library to retrieve data from a third party. Connecting and reading works fine however after 40 seconds the connection gets interrupted by the server due to keepalive ping timeout. After discussion with third party it seems that the Web Socket Client SL library replys to the Ping request of the Web Socket server BUT does not add the "Application data" = 4 bytes in the body of the Pingframe to the Pongframe. Therefor the server does not recognize the Pongframe send by the Web Socket Client SL library and automatically disconnects. Is this a known issue with the libary or am I doing something wrong? Is there a workaround to add the 4 bytes manually to the Pongframe before replying it to the server? Thanks in advance, Roy
Last updated: 2024-04-09
Post by timvh on Modbus TCP Server connection is ESTABLISHED but all holding registers are value 0?
CODESYS Forge
talk
(Post)
Are you sure you need to read holding registers? Have you tried reading input registers?
Last updated: 2026-01-07
Post by fleaplc on Modbus TCP Server connection is ESTABLISHED but all holding registers are value 0?
CODESYS Forge
talk
(Post)
Did you check the communication with a sniffer ? (ex. Wireshark) to check if the holding get to zero by a wrong writing (client initialization?) o something else?
Last updated: 2026-01-27
Post by husarz17 on How change Unity-ID in TCP Modbus Slave
CODESYS Forge
talk
(Post)
I need the same issue. In my application TCP server on raspberry (codesys) should have UnitID 1. But it only works when I am requesting with UnitID 255. And my application can't work with this parameters...
Last updated: 2026-03-31