Post by ph0010421 on How to create a stopwatch? CODESYS Forge talk (Post)
FUNCTION_BLOCK fbdStopwatch VAR_INPUT Condition: BOOL; END_VAR VAR_OUTPUT TimeTaken: TIME; END_VAR VAR StartTime: TIME; fbiStartOs: R_TRIG; fbiStopOs: F_TRIG; END_VAR and then: fbiStartOs(CLK := Condition); fbiStopOs(CLK := Condition); IF fbiStartOs.Q THEN StartTime := TIME(); END_IF; IF fbiStopOs.Q THEN TimeTaken := TIME() - StartTime; END_IF;
Last updated: 2023-12-07

Post by kuuki on Losing focus of variable CODESYS Forge talk (Post)
Hi. Does anyone know how to fix a problem with losing focus of a variable in FBD editor. Sometimes when trying to edit variable name, array index, etc. in network, editor randomly exits "text edit mode" and variable is replaced by text you were typing.
Last updated: 2024-03-26

Post by jeindhoven on Deploying to raspberry pi 5 hangs CODESYS Forge talk (Post)
Yep sure, though now that i think of it, its a pi 4. My bad. The whole ordeal was necessary to use the VGA666 adapter. That needs the old graphical system and GPIO directly on the CPU. Edit: Putty on the virtual development machine connects fine. But i did change the login/pw. The account is still a sudo'er so that should be all right. Edit2: Sorry i get a "Comment rate limit exceeded" from the forum. Then i'll add it as edit here. So i have tried the stock raspberry pi image on a different pi5 (truly 5 this time). Packages updated. Standard password. Same symptoms, no runtime deployed and long hang time. Versions of this pi: pi@raspberrypi:~ $ uname -a Linux raspberrypi 6.12.25+rpt-rpi-2712 #1 SMP PREEMPT Debian 1:6.12.25-1+rpt1 (2025-04-30) aarch64 GNU/Linux pi@raspberrypi:~ $ lsb_release -a No LSB modules are available. Distributor ID: Debian Description: Debian GNU/Linux 12 (bookworm) Release: 12 Codename: bookworm pi@raspberrypi:~ $ apt list --installed | grep openssh-server openssh-server/stable,now 1:9.2p1-2+deb12u6 arm64 [installed,automatic] Attached is the Device information and error text that Codesys comes up with. Edit 3 (Comment rate limit, otherwise it would be a new post) Now i have tried booting an older native Windows 10 machine (no virtualization), and it just works as expected. I have now a raspberry pi 4 and raspberry pi 5 with version 4.16.0.0 of the control application. Windows 10 native: build 19045 (same as virtualised Win 10), same .NET version, same CODESYS version. It seems that running CODESYS virtualized somehow messes with the deployment?
Last updated: 2025-06-23

Post by rita56re on Temu Coupon Code $100 off➧ [act892435] for First-time Users CODESYS Forge talk (Post)
New users can enjoy a fantastic $100 discount on orders over $100. Use the code [act892435] at checkout to receive your $100 off Temu coupon. This offer is available for a limited time only, so don't miss out! Exclusive Deals: β€’ Extra 30% off for new and existing customers, plus up to 90% off on select items. β€’ Temu coupon codes for new users: [act892435] β€’ Temu discount code for new customers: [act892435] β€’ Temu $100 coupon code: [act892435] Special Promotions: β€’ Temu $20 coupon code: [act892435] β€’ Verified Temu coupon code August 2024: [act892435] β€’ WORKING,,$100 OFF** TEMU COUPON CODE|!act892435! Temu new customer offer: [act892435] β€’ Temu discount code 2024 UK: [act892435] β€’ $100 off coupon code Temu: [act892435] β€’ 100% off any order: [act892435] β€’ $100 off Temu code: [act892435] Amazing Bundles and More: β€’ Shoppers can take advantage of numerous discounts and deals with the Temu Coupon Bundle [act892435]. β€’ Temu coupon $100 off for new customers: [act892435] will save you $100 on your order. β€’ Temu coupon code 80% off: [act892435] β€’ Free Temu codes 50% off: [act892435] β€’ Temu coupon $100 off: [act892435] β€’ Temu buy to get $39: [act892435] β€’ Temu 129 coupon bundle: [act892435] β€’ Temu buy 3 to get $99: [act892435] Exclusive Savings: β€’ $100 Off Temu Coupon Code: [act892435] β€’ Temu $100 Off Coupon Code: [act892435] β€’ Temu Coupon Code $100 Bundle: [] β€’ Free Gift On Temu: [act892435] β€’ Temu $40 Off Coupon Code: [act892435] β€’ Temu $100 off coupon code for existing users: [act892435] Get the Most Out of Temu: β€’ Yes, Temu offers a $100 off coupon code [act892435] for first-time users. You can get a $100 bonus plus 30% off any purchase at Temu with the $100 Coupon Bundle if you sign up with the referral code [act892435] and make a first purchase of $100 or more. β€’ For existing users, Temu Coupon code [act892435] can get up to 50% discount on products during checkout. β€’ Temu Coupon Codes for Existing Customers: [act892435]
Last updated: 2024-10-26

Post by sigurdrb on OPC server in "Communication manager" CODESYS Forge talk (Post)
Hi! I was thinking of switching the OPC server config from "Symbol Configuration" to the "Communication manager" in the device tree. I Have a lot of arrays of structs that I have previously declared in the "Persistent Variable" object in the device tree. It seems as it is not supported to directly expose persistant variables to the OPC server like the "older" way of doing it in the symbol config. Is this correct? Do you recommend to just do it the old fashioned way, or should I edit the structure of the global variable list / persistant data / OPC server and set up the OPC server from the "Communication manager" object?
Last updated: 2025-01-20

Post by thn-power on Opaque NodeId in the OPC UA server CODESYS Forge talk (Post)
I'm wondering the same. Using the old symbol configurator opc ua server gave the node id using a string. Must be a way to specify this at build time?
Last updated: 2024-12-16

Post by totorovic on Project loses 'Download time' information CODESYS Forge talk (Post)
Hello, It happens that the offline project (the IDE one) loses the Download information. Because of this the code has to be download again. Is it possible to force this info somewhere? Is it possible to ignore it? How can I solve this ? Thank you
Last updated: 2024-02-13

Post by riccardo on VisuElems.CurrentUserGroupId is not stable CODESYS Forge talk (Post)
Goodmorning TimvH, Thanks for the reply. I don't know if your solution solve my trouble yet, I am going to see the link you sent me. In the mean time I try to explane better what I need to do. I have a turbine system that get in alarm under some condition (E.g low speed of turbine) and block the itself. When the system is stoped there is no speed turbine and the system cannot start. To give to the operetor the possibility to bypass the alarms, there is an acknoledgement alarm pushbutton. This bypass must not work for everyone but only for those client that perform the login by (User Management). Furthermore, if the user perform the (manual or automatic) logout in alarm conditions, the acknowlegment must be annulled and block the system again. To do this, I need to know if an operator is logged in the page and is working to fix the problem; otherwise the syste must autoturn off again. Now I go to study your solution, if I have explaned better and you have another idea tell me please.
Last updated: 2023-11-16

Post by bmatlove on Variable Length Array - Cannot mix variable and fixed length dimensions? CODESYS Forge talk (Post)
Using Codesys 3.5.18.30 I am trying to work with an array of variable length in one dimension, but known in the other dimension. For example, using an array that represents a list of items, each with an attribute profile. I do not know how many items will be in the list, but I know that every item has 5 attributes, like size, weight, etc. Codesys does not seem to be able to accept this. I have referenced Data Type: ARRAY OF documentation page, which is not explicit if variable & fixed length array dimensions can be mixed. In the VAR_IN_OUT scope, I initially tried MY_ARRAY : ARRAY [*, *] OF REAL; which was no problem, of course. I then modified it to MY_ARRAY : ARRAY [*, 1..5] OF REAL; which throws C0006: ', or ]' expected instead of '..' among consequent downstream errors. I then used the Auto Declare -> Array Wizard, which accepted (asterisk)-(asterisk) and 1-5 for 2-dimensional lower and upper bounds. It output: MY_ARRAY: ARRAY[*..*, 1..6] OF INT; which throws the same error stream. What's the deal here? Is this possible?
Last updated: 2025-05-23

Post by totorovic on Softmotion not working with simulation mode CODESYS Forge talk (Post)
Good morning, I think that the mode Simulation does not support the Softmotion functionnality because it runs the CODESYS process with normal priority wich is not a good thing for real-time behavior. If you want to test your PLC project, please use a Codesys Control Softmotion (and your computer must have the Ethercat driver installed) or much easier, download your code into the C6 Smart. BR
Last updated: 2024-05-13

Post by julianramirez on ModbusFB write update CODESYS Forge talk (Post)
Hello everyone, I am testing the ModbusFB library tcp server and so far I am able to create holding registers successfully, however, I am trying to identify after each write which registers got updated (i.e. function code, write value). I can even see the var udiNumWriteRequests, which increases with every write. I noticed that there is logging with the LogStatusInfo method. After I call it I am able to read in the console stuff that I want. Nevertheless, this is only available at the logs and is not easy to decode because it consists on several messages, I would like to know if there is a way for me to retrieve this information from the function itself with pointers or if there is any way to copy the logs messages (assuming that I can filter them with the LoggingOptions to only show what I need) inside the runtime code and not in the console. Thanks for your help :)
Last updated: 2024-09-16

Post by timvh on Refresh visulization realtime CODESYS Forge talk (Post)
Should work by using the property Dynamic bitmap - Bitmap version. Change the value of the variable you linked to this property after you updated the image. See: https://content.helpme-codesys.com/en/CODESYS%20Visualization/_visu_elem_image.html
Last updated: 2024-10-23

Post by pietrobalint on Retain / Persistent Variables in Codesys for Raspberry Pi CODESYS Forge talk (Post)
Hi micik, I am not sure I am using well the code, because I checked the directory and there is no retains.ret file. Now I deleted the code from my project and the values are still works as persistant variables after ssh reboot it seems to me they retain as their previous value. So I am a bit confused, maybe 4.12.0.0 Raspberry Pi SL solved the persitent variable problem...
Last updated: 2024-08-20

Post by sajid on NMEA Serial data read in Control win v3 x64 CODESYS Forge talk (Post)
I am using the SerialCom example program from the CODESYS website to read NMEA strings in CODESYS Control Win V3 x64 through a serial-to-USB converter. However, I occasionally receive only partial data or encounter errors in the received string. A screenshot of expected NMEA string attached for reference. Could you please advise on how to ensure the full NMEA string is received consistently? Error in strRead variable is <value of="" the="" expression="" cannot="" be="" retrieved=""></value>
Last updated: 2025-10-16

Post by sajid on NMEA Serial data read in Control win v3 x64 CODESYS Forge talk (Post)
I am using the SerialCom example program from the CODESYS website to read NMEA strings in CODESYS Control Win V3 x64 through a serial-to-USB converter. However, I occasionally receive only partial data or encounter errors in the received string. A screenshot of expected NMEA string attached for reference. Could you please advise on how to ensure the full NMEA string is received consistently? Error in strRead variable is <value of="" the="" expression="" cannot="" be="" retrieved=""></value>
Last updated: 2025-10-16

Post by dkugler on Management of a PLC network from a remote station CODESYS Forge talk (Post)
I would figure out, how to create a simple html webpage with 2 frames. One frame with buttons to select the plc. A second frame with hyperlink to the webvisu of the plc ("XXX.XXX.XXX.XXX:8080/webvisu.htm"). Selecting other PLC Button has to change the hyperlink in 2. frame. Costs only some time to figure out :-) Or setup a raspberry Pi with small visualization. Set up a button for each plc and add one browser element. Each button writes the URL of the depending plc to the URL setting of the browserelement. Costs 55€ for runtime licence and a Raspberry Pi.
Last updated: 2023-12-04

Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications CODESYS Forge talk (Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14

Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications CODESYS Forge talk (Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14

Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications CODESYS Forge talk (Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14

Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications CODESYS Forge talk (Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14

Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications CODESYS Forge talk (Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14

Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications CODESYS Forge talk (Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14

Post by thn-power on How to change OPC NodeId IdentifierType CODESYS Forge talk (Post)
Hi Yet another OPC UA question. When setting up a OPC server using "Communcation manager" (Symbol set and information model) in Codesys the NodeId is always given as "opaque" type. At least when browsing using UAExpert. Other standard OPC objects use numeric (or string) identifier, but for some reason my variables seems to get opaque/binary type. See attached photo. How can I change this? I can't see that this is a parameter in the CodesysControl.cfg. Can this be specified in the information model nodeset? And is it possible to specify the exact numeric or string NodeId for each instance? And on a related topic, is there a way to export the OPC server nodeId's with variable name so that it can be imported in a OPC Client? The .xml files in the project folder does not seem to contain the NodeId.
Last updated: 2024-09-20

Size of the abyPoolMemory input when creating an fb for the purpose of fb creation (fb extends Factorybase from the fbFactory Library) CODESYS Forge talk (Thread)
Size of the abyPoolMemory input when creating an fb for the purpose of fb creation (fb extends Factorybase from the fbFactory Library)
Last updated: 2023-01-15

Is there any way to remove the warning for having two enumerators with the same value in the same enum? CODESYS Forge talk (Thread)
Is there any way to remove the warning for having two enumerators with the same value in the same enum?
Last updated: 2016-12-22