Post by eaglealex on Length of string and Array of bytes CODESYS Forge talk (Post)
Hello! I have tried read a file to the string variable. But I faced a problem - there is about 2800 bytes of information in file, but string have a limit 2393 bytes. I made two variables with same address (for automatic convertion) - string[3000] and array of bytes[1..3000]. And I noticed that array of bytes contains all information from file, but string shows only first 2393 bytes. So I have lost information. Is there really such a limitation? Or I have an error in my program and Codesys 2.3 have no limit for such kind of conversation between string and array of bytes? Thank you very much!
Last updated: 2025-04-01

Post by kut69 on Retain / Persistent Variables in Codesys for Raspberry Pi CODESYS Forge talk (Post)
Hi, I am interested in details about the .ret file in the filesystem. I have already a project where the file is used (write on demand, read by start) and I want to share it as 'default input' for test devices using the identical application. Opening the .ret file content in a hex editor (I only use a single string retain var) I asked myself what the meaning of the first 24 bytes is. It neither contains a handle to the application nor a reference to the variable. Is this maybe a timestamp? Or a CRC/checksum? Regards, Thomas
Last updated: 2025-05-19

Post by taywinkel on Virtual Runtime CSV Utility Error CODESYS Forge talk (Post)
Hello, I am having trouble figuring out the proper location for my virtual runtime to create a .CSV file. No matter the file location I set, I get error 14 (CANNOT_OPEN_DIRECTORY). I have tried multiple different file paths ('/', '/var/opt/codesysvcontrol/PlcLogic', '/var/opt/codesys/'). I understand that there is only certain places that Codesys can read/write. I am also running this virtual runtime in a Podman container. Does anyone know what the location should be? I attached the archive I was using, a project that tests CSV capability that I borrowed from someone else. Thanks!
Last updated: 2025-09-03

Post by arjunk on How to correctly create a device descriptor (.devdesc.xml) for a custom Linux ARM64 PLC in CODESYS 3.5.21.20? CODESYS Forge talk (Post)
I’m trying to integrate a custom PLC into CODESYS so that it appears under the Device section. From what I understand, this requires a .devdesc.xml device descriptor file. I attempted to create the XML manually, but whenever I try to install it in order to generate a .package file, CODESYS crashes. CODESYS version: 3.5.21.20 Target PLC: Linux ARM64–based My questions are: Is there an official or easier way to generate a valid .devdesc.xml file for a custom PLC? Are there tools, templates, or examples that can help ensure the XML is structured correctly and won’t cause crashes? For Linux ARM64 targets specifically, is there a recommended starting point (e.g., modifying an existing device descriptor)? Any guidance or best practices for creating and packaging custom device descriptors would be greatly appreciated.
Last updated: 2025-10-06

Post by francescoc on Logger in ms CODESYS Forge talk (Post)
Hi, I cannot find any documentation regarding the codesys configuration file. I modified this part to have log files saved to disk: [CmpLog] Logger.0.Name=LOGS/PlcLog Logger.0.Filter=0xFFFFFFFF Logger.0.Enable=1 Logger.0.MaxEntries=20000 Logger.0.MaxFileSize=5000 Logger.0.MaxFiles=10 Logger.0.Backend.0.ClassId=0x0000010B ;sends logger messages to SysOut Logger.0.Backend.1.ClassId=0x00000104 ;writes logger messages in a file Logger.0.Backend.2.ClassId=0x00000135 ;sends logger messages as UDP syslog Logger.0.Type=0x314;Set the timestamp to RTC ;Logger.1.Name=/tmp/CommLog ;Logger.1.Enable=1 I need to have milliseconds in the timestamp as well. What value should I use instead of 0x314? Is there any documentation regarding this file? Thank you
Last updated: 2024-03-16

Post by k2saki on CNC / G-Code streaming processing ( to start quickly in long G-Code File ) CODESYS Forge talk (Post)
Is it possible like G-Code streaming processing (like FANUC or SIEMENS DNC Function )? Or Does anyone know the tips for CODESYS Motion to start moving long Long G-Code File quickly? I have to wait long time after "Start" button to start moving, I have to wait finishing interpreting whole G-Code file, ( and I have to prepare huge buffer to store. ) Now, I'm working on my CNC Project using SMC_ReadNCFile2, and SMC_NcInterpreter to preprocess G-Code. I tried to set SMC_Interpolator.xExecute to true to Start while after SMC_NcInterpreter processed more 50-line of G-Code, but that not worked, I had to wait SMC_NcInterpreter processed all lines to start SMC_Interpolator. G-Code have about 2000 lines of XY of G01 (or more over.. ) of short segment that a CAM software has exploded from NURBS Curve.
Last updated: 2024-05-03

Post by sbrauns on Codemeter log error: API Error 200 (ENTRY NOT FOUND) occurred! CODESYS Forge talk (Post)
Hi, I am using Codesyscontrol for linux 4.11 with an USB dongle with license. The log file from codemeter shows a constant error message which repeats every minute: Entry (6000437:8755) not found - Event WB0200 (ENTRY NOT FOUND), Request IP-Address local(IPV4) with UserLimit API Error 200 (ENTRY NOT FOUND) occurred! The log file from Codesyscontrol itself shows runtime licensed and I experience no other issues. But I am still concerned about the error message in the log file. Does anybody know what this is and how to fix it? thanks
Last updated: 2024-05-08

Post by leon78 on Codesys 3.5 SP17 Patch 2 CheckBounds (POUs for Implicit Checks) CODESYS Forge talk (Post)
Unfortunately, it was fixed in SP19, but I need SP17 CDS-82162 Bug Compiler: Checkbounds is not working for dynamic arrays with VAR_IN_OUT as index access Fixed [[GENERAL]] Compilerversion >= 3.5.19.0 https://de.codesys.com/fileadmin/data/Images/System/Releaseinformation/Release-Notes-CODESYS-35190.html
Last updated: 2023-11-16

Post by nathant on Running webvisu with Codesys Control Win V3 in Simulation Mode CODESYS Forge talk (Post)
Hello - I was wondering if I can run a webvisu in Codesys V3.5 SP 18 when using the Control Win V3 soft PLC. I don't see anything saying I can't do this, but I haven't been able to access the webvisu using conventional methods. Thanks.
Last updated: 2023-11-28

Post by nathant on Running webvisu with Codesys Control Win V3 in Simulation Mode CODESYS Forge talk (Post)
Hello - I was wondering if I can run a webvisu in Codesys V3.5 SP 18 when using the Control Win V3 soft PLC. I don't see anything saying I can't do this, but I haven't been able to access the webvisu using conventional methods. Thanks.
Last updated: 2023-11-28

Post by theo on Error codesys raspberry CODESYS Forge talk (Post)
Bonjour a tous je souhaiterai connecter mon Raspberry a codesys en tant qu'automate cependant lorsque je enterent l'IP dans le encadré et que je fais entrer voici le message qui apparait, je suis français mais en anglais ça signifie : " vous n'êtes actuellement pas autorisé a exécuter cette action sur l'appareil. Please enter the username and password of a user account with the required access rights.
Last updated: 2023-12-08

Post by mos89p on CodeSysControlWinV3x64 CODESYS Forge talk (Post)
Hello Check: on the latest version the location change: If the PLC is started with the "CODESYS Control Win SysTray PLC Control", it runs in the Windows user account "LocalSystem" and therefore the effective working directory is "C:\Windows\system32\config\systemprofile\AppData\Roaming\CODESYS\" or "C:\Windows\SysWOW64\config\systemprofile\AppData\Roaming\CODESYS\". An administrator account is required to access these folders
Last updated: 2024-07-11

Post by marks on Regarding trend storage access error CODESYS Forge talk (Post)
I had this problem when running the application as a Simulation. When I wrote it to the Pi all worked as expected. If this isn't the case for you, we've seen some issues with sqlite on the Pi's - so reset Origin and re-download may help in that case. Good luck, Mark
Last updated: 2024-07-24

Post by eschwellinger on RS485 CAN HAT to Cosesys CODESYS Forge talk (Post)
Hi if you add in (ttyAMA0 should fit to your HAT's device [SysCom] Linux.Devicefile.1=/dev/ttyAMA0 to /etc/CODESYSControl_Usr.cfg since 4.12.0.0 version /etc/codesyscontrol/CODESYSControl_Usr.cfg then access in CODESYS with Com1 should do it. Keep in mind that only adapters work (for RS485) which do determine the send/receive direction in hardware
Last updated: 2024-10-28

Post by timvh on Colors look different when logged in and running CODESYS Forge talk (Post)
At the top of the Visualisation Properties View, you can enable the "Advanced" options. This will give you access to more properties than what you currently see. There might be a variable linked to the "advanced" colour property where the fill colour is determined by the value of this variable (dword).
Last updated: 2025-01-09

Post by trusty-squire on Help with __SYSTEM.VAR_INFO CODESYS Forge talk (Post)
Not knowing exactly what you want to accomplish, you can try to use VAR_INPUT MyVar: POINTER TO BOOL; END_VAR MyVar contains the address of your referenced variable, and MyVar^ dereferences it allowing you to access the value. If this doesn't meet your needs, could you add more detail on what you are trying to accomplish?
Last updated: 2025-01-26

Post by benemenn on Type mappings in Datasource CODESYS Forge talk (Post)
Hi! I am trying to achieve the same issue. Has there been a solution? I can create the mapping, and map the local variable, but somehow the object does not update. Furthermore, i have an issue where codesys doesn't let me set ReadWrite accesses to the variables in the "Type Mapping" place. The access will simply not be set. Has anyone ran int that issue?
Last updated: 2025-04-02

Post by llewv123 on Codesys Control for RPi and Waveshare AD/DA hat CODESYS Forge talk (Post)
Good day, I am attempting to use a Waveshare AD/DA precision HAT with RPi 4B+, using Codesys Control for Rpi. The waveshare hat uses SPI. I am successfully using the RPi GPIO (inputs and outputs) but do not know how to access the AD/DA channels. Any help would be appreciated.
Last updated: 2025-08-04

Post by timvh on Sysfile inuts CODESYS Forge talk (Post)
To prevent ambiguous use of this enumeration value. Let's say another ENUM is available in your project or in another library which has an enumeration value AM_WRITE, then it is not clear which AM_WRITE you want to assign. By this qualified access to the SysFile.AM_WRITE, it is completely clear for the compiler.
Last updated: 2024-01-14

Post by francescoc on Access to the path *** is denied CODESYS Forge talk (Post)
Hello, I encountered similar problems, and it appears they were linked to certain add-ons. Resolving this issue turned out to be quite complex. However, we managed to find a solution by downgrading both the "CODESYS Communication" and "CODESYS Recipes" components via the CODESYS Installer, accessible under the "Tools" section.
Last updated: 2024-02-12

Post by jdjennings1962 on Is there any support for I2C on Raspberry Pi? CODESYS Forge talk (Post)
Hello, our team is able to use Raspberry Pi on CODESYS, but we purchased two peripherals that utilize I2C and we cannot figure out how to access these devices in CODESYS. But they are working using Python. Does anyone have a suggestion or an existing library that might help support this? Thank you, Jeff
Last updated: 2024-02-29

Post by timvh on Limiting Memory Access of an Array to Within its Bounds CODESYS Forge talk (Post)
Add the object "POU for Implicit Checks" to your application, then select "Bounds check". This will create a function which is automatically called each time an array is write accessed. In the function you can handle "out of bounds" situations. By default it will be limited to its lower or upper bound.
Last updated: 2024-03-06

Post by yannickasselin on Linux ARM64 SL, GPIO Access CODESYS Forge talk (Post)
A bit of work but maybe possible to make your own driver using "CODESYS Control SL Extension Package". Look at the "ExternalIoDrv" example. It is installed in "C:\Program Files\CODESYS 3.5.20.0\CODESYS\CODESYS Control SL Extension Package" when you install the "CODESYS Control for Linux SL".
Last updated: 2024-05-08

Post by talhaali on Can't read Alarm Class from Alarm Storage CODESYS Forge talk (Post)
Hi, I am trying to access active alarms in code(As alarm count variable updates only when we go to to alarm table frame in visualization). I wrote following code but it is not working: VAR iCountActiveAlarms : INT; parritfActiveAlarms : POINTER TO ARRAY[0..0] OF IAlarm; itfAlarmManagerClientAll : IAlarmManagerClient; END_VAR AlarmManager.g_AlarmHandler.GetActiveAlarms( itfAlarmManagerClient :=itfAlarmManagerClientAll, iCountActiveAlarms => iCountActiveAlarms, parritfActiveAlarms => parritfActiveAlarms); The Value is always 0. Please help.
Last updated: 2024-06-06

Post by talhaali on Can't read Alarm Class from Alarm Storage CODESYS Forge talk (Post)
Hi, I am trying to access active alarms in code(As alarm count variable updates only when we go to to alarm table frame in visualization). I wrote following code but it is not working: VAR iCountActiveAlarms : INT; parritfActiveAlarms : POINTER TO ARRAY[0..0] OF IAlarm; itfAlarmManagerClientAll : IAlarmManagerClient; END_VAR AlarmManager.g_AlarmHandler.GetActiveAlarms( itfAlarmManagerClient :=itfAlarmManagerClientAll, iCountActiveAlarms => iCountActiveAlarms, parritfActiveAlarms => parritfActiveAlarms); The Value is always 0. Please help.
Last updated: 2024-06-06