Post by alimans on Unrecoverable SoftMotion state after switch to PreOp
CODESYS Forge
talk
(Post)
Hi Kim, Hi eschwellinger, how you could solve the problem? I am using Codesys V3.5.19.60 and I still have the same problem. It will work only after a warm/cold restart. Thank you in advance for your kind help.
Last updated: 2025-10-22
Post by kenth1973 on MC_Phasing state explenation
CODESYS Forge
talk
(Post)
Hi George. Thx for the info and recommendation - the robot is running production at customer. But - would you have any information about the states numbers and their different explenations?
Last updated: 2025-12-11
Post by gseidel on MC_Phasing state explenation
CODESYS Forge
talk
(Post)
Hi kenth1973, no, we do not have this kind of information on internal variables. iPhasingState has been removed and is no longer present in current versions of SoftMotion. Best regards, Georg
Last updated: 2025-12-17
Post by gseidel on MC_Phasing state explenation
CODESYS Forge
talk
(Post)
Hi kenth1973, it is not a matter of who created the function block. It is just that we don't have, and don't provide, documentation about internal implementation details... Hope you can understand that, Georg
Last updated: 2025-12-17
Post by kenth1973 on MC_Phasing state explenation
CODESYS Forge
talk
(Post)
Hi George - ok thanks - but who created this FB in the first place? Could you lead me to the creator company? Is CODESYS not the old S3 that created this FB? :-)
Last updated: 2025-12-17
Post by r-c-r on SM3RaspiStepper 0.0.0.6 issue
CODESYS Forge
talk
(Post)
Ok, so i made some tests in the meantime and i have some conclusions. It apears that the enable bit is activated only when a motion function is executed. I implemented a very simple program with MC_Power and MC_Jog. If i enable everything on MC_Power, the enable GPIO pin stays off. However, as soon as the MC_Jog function is used the enable GPIO pin turns ON and remains ON. In version 0.0.0.4 this is not happening. The GPIO enable pin turns on or off when the MC_Power is enabled or disabled. From this behaviour i understand that in version 0.0.0.6 the GPIO enable bit is activated together with pulse and dir pins when motion starts. When motion stops, enable bit remains with the last state (on in this case) and you cannot turn it off for example. For me this bit is useful because i can turn on and off the stepper drive with MC_Power function. Now i can turn it on, but never off.
Last updated: 2025-04-04
Post by hoatran on Use third party actuator with IO-Link Master (IFM)
CODESYS Forge
talk
(Post)
The generic sensor FB is for controlling the sensor via its cyclic input (PDI) and output (PDO). In this case, ifm raw cyclic input and output data are WORDs (16 bits total) The PDO data from the Buerkert unit are SINT (8 bits) In this case, I would use the unpackword fb from the CAA memory library to unpack the valve feed back value into the appropriate location.
Last updated: 2024-04-23
Post by bahrt on Raspberry Pi GPIO mapping
CODESYS Forge
talk
(Post)
Hi I am about to configure ALL GPIOs on a Raspberry Pi 3 model B V1.2. It seems that I have limited understanding of why not all the IOβs become available with the corresponding mapped IOβs β the 'dwInUse' contains mapping of the inputs from GPIO0 to GPIO27. But 'dwInputs' are only showing GPIO0 to GPIO8 and GPIO15 as available inputs. These mentioned inputs work fine You will be able to watch the limited mapped IO activity here: https://drive.google.com/file/d/1zz4PBNBfRZBF2YkiJ2VQxw6L9MBVji7R/view?usp=sharing Can you please bring your best idea on why GPIO09 to GPIO14 and GPIO16 to GPIO27 state are not active (at a fixed zero state) in the dwInputs register? Thanks in advance. Best regards Andreas Bahrt
Last updated: 2023-11-21
Post by tmarmy1 on Redundancy for RTE x64 - stuck in standalone
CODESYS Forge
talk
(Post)
Sorry if this has been asked before, but I can't seem to locate a thread that leads me answers. I am running two RTE x64 softPLCs, one on the host machine and a second via a VM. I have managed to finally get both to a position that they see each other, but they are in standalone mode instead of an active/passive state for failover (image attached). Every attempt to sync via the button fails. There is probably some step or option that I have missed in my bumbling through this learning process, but for the life of me I can't seem to figure it out. Anyone got any suggestions what I need to look at to get this into an active/passive redundancy state?
Last updated: 2025-02-20
Post by pernockham on *Exception* Async service: ServiceGroup=17, IP=0x5fa45617, Component=CmpSrv
CODESYS Forge
talk
(Post)
*** The system may be in an inconsistent state, please reboot *** *Exception* Async service: ServiceGroup=17, IP=0x5fa45617, Component=CmpSrv Every time at the instant that I Login to the system a message that the "system may be in an inconsistent state, please reboot" is written in the log. If I logout and repeat login a new entry is set. My system is a "Control for linux SL" running on a debian linux host. Im running it on my desk without any IO attached so message might be caused from that, but I doubt i have seen it before. Rebooting makes no difference. Anyone that have a clue of how I should interpret this error message?
Last updated: 2025-09-26
Post by gurke258 on Codesys Safety EtherCAT with Beckhoff
CODESYS Forge
talk
(Post)
Okay, the solution was so simple... In my case, you first have to add the EL1918 and then the EL2904... then the connection is made automatically. I probably had something else before and then added the EL1918... then it doesn't catch the connection :/
Last updated: 2023-11-08
Post by installwhat on exception in system events handler
CODESYS Forge
talk
(Post)
I've noticed that exceptions in system event handlers don't stop the runtime or call the exception handler. I've included a very basic example to demonstrate. It seems likely this is undesired but unavoidable. Is that the case? Is there any advice on the matter? Thanks
Last updated: 2024-07-08
Post by squale on URL jumps between different visualizations behind a reverse proxy
CODESYS Forge
talk
(Post)
Hi kevinrn, I have the same question as yours. On my side I try to make nginx work but it doesn't goes well. I think the sub_filter doesn't work int this case.
Last updated: 2024-07-26
Post by lyngaansns on Python script: Launch Codesys, Execute Script, Exit Codesys
CODESYS Forge
talk
(Post)
Hello I am looking for the same thing, so i don't have an answer, but in your case you could possibly use the --noUI flag when running codesys, if you don't care about showing what's happening.
Last updated: 2024-09-06
Post by jari-koivuluoma on Problem trying Net Base Services 3.5.15.0 TCP connection
CODESYS Forge
talk
(Post)
Solved. Just in case that someone else is now to this also. It seems that the xDone of the TCP_Connection FB goes true once client disconnects and then you need to reset the FB by setting the xEnable to false.
Last updated: 2024-10-04
Post by pistola on Case Function - Multiple Conditions, Is it possible?
CODESYS Forge
talk
(Post)
Thanks for the information, I ended up just making a long if else statement as each variable had 3 possible options, I figured at least this way it would still work.
Last updated: 2024-11-05
Post by aikapan on Ethernet/IP Scanner Exception
CODESYS Forge
talk
(Post)
Same here. plcload in my case is about 7% while running. Watchdog ENIPScannerIOTask was about 200ms. Max cycle around 6ms, normal cycle time 4ms. Probably just increase the watchdog to 2000ms? or so... (Hardware: A Panel from Weintek)
Last updated: 2024-11-28
Post by eschwellinger on Newly created texlists wont appear in the selection dropdown
CODESYS Forge
talk
(Post)
Guess you need to update Visualization Support Package to latest version (4.5.0.0) in case you are using CODESYS Visualization 4.7.0.0
Last updated: 2024-12-18
Post by gseidel on Beckhoff EL7037 softmotion
CODESYS Forge
talk
(Post)
Hi Stefan, we will update our driver to support the EL7037 in our next release of SoftMotion. In case you are interested to test a pre-release, please contact our support and mention this forum post. Best regards, Georg
Last updated: 2024-12-23
Post by matthewkim on Codesys Gateway not running
CODESYS Forge
talk
(Post)
In my case, I used a different version of gateway. ex)3.5.18.5 sysTray gateway start did not work, so I terminated it and made it work with 3.5.18.3 in "codesys installer" "Settings" and was able to connect to the PLC.
Last updated: 2025-06-12
Post by matthewkim on Codesys Gateway not running
CODESYS Forge
talk
(Post)
In my case, I used a different version of gateway. ex)3.5.18.5 sysTray gateway start did not work, so I terminated it and made it work with 3.5.18.3 in "codesys installer" "Settings" and was able to connect to the PLC.
Last updated: 2025-06-12
Post by matthewkim on Codesys Gateway not running
CODESYS Forge
talk
(Post)
In my case, I used a different version of gateway. ex)3.5.18.5 sysTray gateway start did not work, so I terminated it and made it work with 3.5.18.3 in "codesys installer" "Settings" and was able to connect to the PLC.
Last updated: 2025-06-12
Post by arwie on Use MC_Home without enabling the drive for homing method 35
CODESYS Forge
talk
(Post)
So we pay 380β¬ for SoftMotion licenses for each robot, but have to implement such an obvious use case manually without any hint in the official documentation how to achieve this. This is crazy...
Last updated: 2025-07-31
Post by jonasz on TargetVisu not accepting touch inputs
CODESYS Forge
talk
(Post)
So, in my case, the solution is to uncheck the option to support client animation and overlay native elements. Visualisation Manager -> Settings -> General Settings
Last updated: 2025-08-19
Post by eschwellinger on CODESYS control on RPi starts, shortly runs, then exits
CODESYS Forge
talk
(Post)
in case you are using latest hw revision, there have been added some mac adresses - for the 4.17.0.0 release this might solve it. If not we need to investigate deeper. If it is application related you need to check the plclogger.
Last updated: 2025-09-02
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.