Post by vformanek on OPCUA Datasource, can not login...
CODESYS Forge
talk
(Post)
Hello? I have a problem with datasource... I am trying to connect to a OPCUA server. I create a datasource, but I can not login into it. I need to use login credentials to login... Everything works fine in UAExpert, but in codesys I cant seem to get in properly using the login credentials... I have tried to configure the datasource initializer but seem to keep failing... Do I need to call it somewhere ? Will the find endpoints work with this configured to store my password ? !
Last updated: 2023-11-20
Post by sachem on SysFileGetTime problem
CODESYS Forge
talk
(Post)
Good morning. I'm working with a Weidmuller controller using Codesys. My project use OPC-UA to communicate an application in my pc with the controller. Yesterday, I installed the license of the controller and test it, and the communication works perfect. I use the communication with anonymous login, and works fine. But, hours later, the anonymous login don't work, and the controller only allows connection via OPC with username and password. Someone know why this happend? Thanks
Last updated: 2024-04-09
Post by alexgooi on Codesys KNX implementation
CODESYS Forge
talk
(Post)
Dear forum, We are currently doing some research on the Codesys KNX implementation (https://store.codesys.com/en/codesys-knx-sl.html). We almost have it working but we are missing the last part. The setup: We have a Codesys virtual control container running on docker (4.17.0.0), the I/O is running over an Ethernet IP coupler (Weidmüller), and this is running fine. As far as I’m concerned this tells me that the ethernet device is working properly (the container has access to the outside world, including multicast). Underneath this ethernet adapter the KNX module is added (see picture). In the KNX device (Codesys) 2 input variables are added (see picture), and these are exported to ETS (ETS 5). In ETS A Codesys KNX device has been imported and the Codesys export was imported, afterwards the group addresses are attached to the variables (see picture). Afterwards this configuration is downloaded to the Codesys controller (Container) via ETS. ETS asks for the pressing of the programming button, when the virtual programming button is pressed the download starts and finishes without any errors. This tells me that ETS is communicating with the Codesys controller, and that the download process is ok (so far so good). Now the part where we are struggling with, somehow we need to convert the KNX TP to KNX IP. For this we have the following interface: Zenio KIPI SC (https://www.zennio.com/product/kipi-sc/) this is a KNX TP to IP interface. We have the following setup for this device (see picture) (an IP in the same subnet is used). We tried multiple combinations of IP addresses but the TP devices are simply not communicating to the Codesys container. Does anyone has any advice on what to try next. To make the question more explicit how can we link the TP bus to the Codesys device? Kind Regards Alex
Last updated: 2026-01-05
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.