Search talk: C Implemented Library

 
<< < 1 .. 41 42 43 (Page 43 of 43)

Post by salvadegianluca on List files in a directory with SysDiropen And SysDirRead CODESYS Forge talk (Post)
Good morning; I'm facing an issue that seems being caused by the library itself. I'm trying to create the list of all the files that are stored inside a psecific directory. Unluckily the first file is allways hidden. VAR CONSTANT arysEmptyArray:ARRAY[iArrayMinDimension..iArrayMAXDimension] OF STRING := [(iArrayMAXDimension - iArrayMinDimension)('')]; iArrayMinDimension:INT := 1; iArrayMAXDimension:INT := 99; END_VAR VAR_INPUT sDirectoryToInspect:STRING; sSearchFilter:STRING; END_VAR VAR_IN_OUT xCheckFileInsideDirectory:BOOL; END_VAR VAR arysListOfFoundFiles:ARRAY[iArrayMinDimension..iArrayMAXDimension] OF STRING; sNullString:STRING; iNullIndex:INT := 0; libInfoAboutThePath:DirInfo; libResultOfThePathMonitoring:CmpErrors.RTS_IEC_RESULT; libInstanceToMonitorThePath:CmpErrors.RTS_IEC_HANDLE; sEntityToSearch:STRING; dMaxEntityDimension:DINT := SIZEOF(sEntityToSearch); libFileInfo:DirInfo; sFilteredFileName:STRING; iIndexToScrollArrays:INT; END_VAR IF xCheckFileInsideDirectory THEN arysListOfFoundFiles:=arysEmptyArray; iIndexToScrollArrays:=iArrayMinDimension; libInstanceToMonitorThePath:= SysDirOpen(szDir:= sDirectoryToInspect,szDirEntry:=sNullString,diMaxDirEntry:= iNullIndex,pDirInfo:= ADR(libInfoAboutThePath),pResult:= ADR(libResultOfThePathMonitoring)); WHILE libResultOfThePathMonitoring = Errors.ERR_OK AND iIndexToScrollArrays <= iArrayMAXDimension DO sEntityToSearch:= ''; libResultOfThePathMonitoring:=SysDirRead(hDir:=libInstanceToMonitorThePath,szDirEntry:=sEntityToSearch,diMaxDirEntry:=dMaxEntityDimension,pDirInfo:=ADR(libFileInfo)); sFilteredFileName:= FUN_06_00_FindItemInString_0(sFilter:=sSearchFilter,sSource:=sEntityToSearch); IF sFilteredFileName <> '' THEN arysListOfFoundFiles[iIndexToScrollArrays]:=sFilteredFileName; iIndexToScrollArrays:=iIndexToScrollArrays + 1; END_IF IF libResultOfThePathMonitoring <> Errors.ERR_OK THEN libResultOfThePathMonitoring:= Errors.ERR_OK; END_IF END_WHILE libResultOfThePathMonitoring:=SysDirClose(hDir:= libInstanceToMonitorThePath); xCheckFileInsideDirectory:=FALSE; END_IF How is possible to solve this issue? Any known work around?
Last updated: 2024-09-17

Post by salvadegianluca on List files in a directory with SysDiropen And SysDirRead CODESYS Forge talk (Post)
Good morning; I'm facing an issue that seems being caused by the library itself. I'm trying to create the list of all the files that are stored inside a psecific directory. Unluckily the first file is allways hidden. VAR CONSTANT arysEmptyArray:ARRAY[iArrayMinDimension..iArrayMAXDimension] OF STRING := [(iArrayMAXDimension - iArrayMinDimension)('')]; iArrayMinDimension:INT := 1; iArrayMAXDimension:INT := 99; END_VAR VAR_INPUT sDirectoryToInspect:STRING; sSearchFilter:STRING; END_VAR VAR_IN_OUT xCheckFileInsideDirectory:BOOL; END_VAR VAR arysListOfFoundFiles:ARRAY[iArrayMinDimension..iArrayMAXDimension] OF STRING; sNullString:STRING; iNullIndex:INT := 0; libInfoAboutThePath:DirInfo; libResultOfThePathMonitoring:CmpErrors.RTS_IEC_RESULT; libInstanceToMonitorThePath:CmpErrors.RTS_IEC_HANDLE; sEntityToSearch:STRING; dMaxEntityDimension:DINT := SIZEOF(sEntityToSearch); libFileInfo:DirInfo; sFilteredFileName:STRING; iIndexToScrollArrays:INT; END_VAR IF xCheckFileInsideDirectory THEN arysListOfFoundFiles:=arysEmptyArray; iIndexToScrollArrays:=iArrayMinDimension; libInstanceToMonitorThePath:= SysDirOpen(szDir:= sDirectoryToInspect,szDirEntry:=sNullString,diMaxDirEntry:= iNullIndex,pDirInfo:= ADR(libInfoAboutThePath),pResult:= ADR(libResultOfThePathMonitoring)); WHILE libResultOfThePathMonitoring = Errors.ERR_OK AND iIndexToScrollArrays <= iArrayMAXDimension DO sEntityToSearch:= ''; libResultOfThePathMonitoring:=SysDirRead(hDir:=libInstanceToMonitorThePath,szDirEntry:=sEntityToSearch,diMaxDirEntry:=dMaxEntityDimension,pDirInfo:=ADR(libFileInfo)); sFilteredFileName:= FUN_06_00_FindItemInString_0(sFilter:=sSearchFilter,sSource:=sEntityToSearch); IF sFilteredFileName <> '' THEN arysListOfFoundFiles[iIndexToScrollArrays]:=sFilteredFileName; iIndexToScrollArrays:=iIndexToScrollArrays + 1; END_IF IF libResultOfThePathMonitoring <> Errors.ERR_OK THEN libResultOfThePathMonitoring:= Errors.ERR_OK; END_IF END_WHILE libResultOfThePathMonitoring:=SysDirClose(hDir:= libInstanceToMonitorThePath); xCheckFileInsideDirectory:=FALSE; END_IF How is possible to solve this issue? Any known work around?
Last updated: 2024-09-17

Post by lbartik on J1939 TX/RX PDU1 CODESYS Forge talk (Post)
Is it possible to transmit a PDU1 PGN using the J1939 manager and local device? What if I need to transmit a PGN RQST via 0xEA00 (PGN 59904)? How would I do this P2P (Destination < 0xFF) or broadcast (Destination 0xFF)? I don't think this is possible for any destination type. I don't think it's possible to receive broadcast PDU1 messages either. For example, an address claim PGN 60928 (0x18EEFF80) is addressed to all nodes (0xFF) and not any specific local device so it will be filtered out. These are major oversights in the IoDrvJ1939 library to not support every PDU1 RX/TX scenario. IoDrvJ1939 supported scenario: 1. Receive (RX) PDU1 (P2P) destination-specific (PDU-specific < 255) to local device with matching address IoDrvJ1939 unsupported scenarios: 1. Receive (RX) PDU1 (P2P) global (PDU-specific = 255) 2. Transmit (TX) PDU1 (P2P) global (PDU-specific = 255) 3. Transmit (TX) PDU1 (P2P) destination-specific (PDU-specific < 255)
Last updated: 2024-09-23

Post by breiter on Frustration-Fueled Feedback on Project File Management and Git Integration CODESYS Forge talk (Post)
Hi, supporting a text based storage format is on our roadmap, see https://www.codesys.com/the-system/releases-updates-lifecycle/release-plan-roadmap.html It will be an Add-On feature called "File Based Storage" for the professional developer edition. Structured text POUs will be stored as plain text. Other graphical languages will remain in an xml format. You will be able to switch the storage type for projects. Certain workflows will become easier this way. Nevertheless restrictions will remain because of CODESYS specific storage logic (for example how methods below function blocks are stored as file). So merging using our Git Integration Add-On remains the recommended workflow. A workflow involving Visual Studio Code as the main IDE is not supported. Simply because many topics like library management, task configuration or fieldbus configurators are not available for VS Code. A PLC project is a lot more than just some ST POUs. Best Regards
Last updated: 2024-10-16

Post by dwpessoa on CNC Jumps G20 - SMC_NCInterpreter and long time to process CODESYS Forge talk (Post)
I am studying and developing a Softmotion+CNC system for a machine that executes multiple pieces. The G code program is written by the machine operator and each cycle execute 1 piece. The programs are large, exceeding 1000 lines and using up to 8 axes (X, Y, Z, A, B, C, P and Q). The machine needs to run cyclically, executing N pieces (selected by the Operator)... so I tested it using Looping and counters (G36 G37 and G20) and it worked, but it takes a long time to process, and the more pieces I need, the longer the processing time and this is totally impracticable. I found this solution which was very good, and for a few cycles it works well, but for 99999 pieces of a program with 1000 lines, it doesn't work very well... Another solution I tested is to maintain the interpolator with an automatic restart, that is, I load the program without looping (without G20) and give it another start as soon as it finishes. This partially resolved it, but there is still a delay in processing SMC_NCInterpreter in each restart :(. Another solution I thought of is to manually create the SMC_GEOINFO structure and then reuse it, avoinding the Interpreter, but reading the documentation and checking the structure filled by standard blocks, I noticed that there doesn't seem to be a "JUMP" function in the structure! In other words, the SMC_NCInterpreter actually keeps copying and copying the program section for each jump (G20)... If I repeat a 10-line program 1000 times, I will have a structure with more than 10000 lines... possibly this is the cause of take so long to process. Has anyone ever had a problem like this? I believe the same thing happens with typical applications with manipulator robots using Codesys in continuous cycles, and I would like to know if there is any solution, or even if I am misinterpreting the G20 question in SMC_GEOINFO. Thanks!
Last updated: 2023-09-20

Post by alex-at-xana on EThercat Dynamic configuration CODESYS Forge talk (Post)
Hi Everyone, For a fast monitoring system I am using Ethercat oversampling and timestamping inputs. As the customers has a lot of different configurations out in the field, we went for a dynamic Ethercat configuration. Already got the whole detection chain working but now I am stuck since two days in debugging the configuration. Here are my quesitons: I extended the dynamic config example for the EL3632 16#0E303052: //EL3632 pSlave^.SetDCSettings(TRUE,TRUE,80,80,TRUE,4000,0,0); pSlave^.AddSyncManager(16#1000,128,16#26,TRUE,3); pSlave^.AddSyncManager(16#1080,128,16#22,TRUE,2); pSlave^.AddSyncManager(16#1100,0,16#4,TRUE,1); pSlave^.AddSyncManager(16#1110,214,16#20,TRUE,0); pSlave^.AddFMMU(0,214,0,7,16#1110,0,1,1); pSlave^.AddFMMU(0,1,0,0,16#80D,0,1,1); xKnown := TRUE; This leads to a PLL Error for these devices. I double and triple checked the configuraton, but cannot find the issue. There seems to be one difference: the config dialog creates a startup parameter: 16#10F3:16#05, Name: Command_0, Value:0. Bitlen: 16, Stop on fault: false, jumpt at fault: false: next line: 0 a) I do not find information on how to set this in my code. Can you help me there? b) Without trying to set the value, I get a PLL error for these devices in the master log. Is the config wrong? c) Do I need to set the Master to Autoconfigure or Manual? I used autoconfigure for my tests. The stack creates input data addresses for the slaves input data range (pSlaves[i].InputData) which are different from those created when I use the Engineering tools dialogs to configure Ethercat. Specifically, the addresses seem to be aligned at 16 byte boundaries when they are created using the engineering tool, but may appear at uneven addresses when I use the script in dynamic config. I did not try to access ULINT at uneven addresses yet, but I am suspecting this may be a problem. Do I need to manually align the addresses ? Any help is appreciated...
Last updated: 2024-09-10

Post by struccc on Application failing to boot after system reboot CODESYS Forge talk (Post)
I started to experience the same issue, after upgrading to 3.5.19 , and still persists with 3.5.20.3 , using CodesysControlWinV3 x64 on Windows. Unfortunately, this is a live application, normally it is running for months without interruption - so it was a surprise at the last cold start... It was not possible to go online with the original version, so I couldn't see the application, or system status, just the log message. First time I manually clean the Application from the PlcLogic directory (there was no coredump file in there), then I could start the runtime service, and do a fresh download, and set the bootproject. I could not try a cold system reboot - it's in a 24/7 production environment, and I was under heavy pressure to start... What I did, I have created a backup from the * complete * runtime directory, from the failed, and fixed version - before and after download. This directory in my case C:\ProgramData\CODESYS\CODESYSControlWinV3x64\55096128 - At the next shutdown, it was sufficient to copy back this backup completely, and could start the runtime service afterwards. Ugly, but local staff with some skills can do it without programming tool... I don't store any live data, configuration, log files, persistent data in this directory - the only reason I need this is to edit the CodesysControl... .cfg file.... And to see the logfiles in emergencies like this. The application concerned doesn't use any retain area. - exactly for these reasons - Maybe that is causing the problem with the newer runtime versions As far as I see, this problem occurs only if the power of the Windows PLC is interrupted without a proper shutdown. Unfortunately, this can happen sometimes. The newer versions, seems tp modify CodesysControl.cfg on the fly, and register the applications, and bootproject information after download. (I don't really see CodesysControl.cfg a proper location for this... but that's just my feeling) So now I had a look at CodesysCotrol.cfg on my laptop and I found: [CmpRetain] ;Retain.SRAM.Size=0x200200 ;Retain.SRAM.Address=0xFA3C5776 ;SimulateSRAM=1 [CmpApp] ;Bootproject.CreateOnDownload=0 ;Bootproject.StoreOnlyOnDownload=0 ;Bootproject.InvalidateByRename=1 ;Bootproject.InvalidateBySetting=1 ;Bootproject.InvalidateNever=0 ;PersistentForce=0 ;RetainType.Applications=InSRAM ;RetainType.Applications=OnPowerfail ;RetainType.Applications=None ;Exception.Hardware.GlobalStop=1 Application.1=MyTestAppNoRetain The last line appeared after download and boot project creation. Maybe... Should set RetainType.Applications=None? I wonder about all these settings, but... Will write separately about it. I hope this helps a little...
Last updated: 2024-11-21

Post by kevinrn on CODESYS Development System V3 installation auf unter Parallells Windows 11auf MAC PRO M1 ARM Prozessor CODESYS Forge talk (Post)
Hallo, das Thema ist ja etwas offtopic. Aber ich kann gerne mal von meiner Erfahrung berichten: Nachdem ich von 2020 bis 2023 immer einen MacBook Pro mit Intel CPU hatte (i9/32GB) und nun seit Januar 2024 mit dem M3 Max unterwegs bin kann ich Nachfolgendes berichten. Infos zu den Aufgaben, die ich damit erledige: Die Runtime nutze ich nicht auf dem Mac (Wenn ich von Mac rede, dann meine ich damit die Win11 ARM64 Parallels Umgebung) Ich nutze die IDE für Library development und für automatisierungs Tests von CI/CD jobs. Weiterhin öffne ich oft große Projektarchive mit teilweise 160 MB. Erfahrungen zur Installation von CODESYS Versionen: Ich habe einige Versionen installiert, unter anderem, 3.5.14.4, 3.5.17.2, 3.5.16.3, 3.5.18.4 und 3.5.19.6. Ich hatte mit keiner einizgen Installation ein Problem. Die Installation lief immer ohne Probleme durch. Runtimes (Control Win) installiere ich nicht. Ich nutze linux basierte Zielsysteme und bei bedarf eine Windows VM auf einen entfernen Host mit X64. Lokales Gateway läuft ebenso Sonstige Erfahrungen: Ich nutze viele Komponenten Querbeet: Alarming, AC Persistence, Symbol Konfiguration, CFC und ST Editor, externes Packages wie STWeep, Git für Library Entwicklung, Visu, etc. Mit keiner dieser "Komponenten" hatte ich schwierigkeiten oder einen Unterschied zu x64 systemen festgestellt. Man muss aber auch sagen, dass das alles nur ein kleiner Bruchteil ist, was die CODESYS Welt beinhaltet, deshalb sind diese Aussagen auch nur subjektiv aus meinem Erfahrungsbereich. Für das Entwickeln von Libraries sehe ich keine Performance Einschränkungen. Ganz im Gegenteil, für das, dass hier eine emulation stattfindet, ist es erstaunlich schnell. Meiner Meinung nach sind sogar einfache und kleine Projekte schneller als beim Intel Mac. Die Akku Leistung mit dem Mac und Parallels ist fantastisch. Lüfter hört man nicht mal bei der Nutzung von CODESYS. Beim Intel konnte ich sonst ein Spiegelei auf der Abdeckung zubereiten... Was evtl. etwas langsamer ist bzw. mir manchmal so vor kommt ist, der CFC Editor im Online Mode. Aber hierzu fehlt mir ein richtiger Vergleich. Fazit: Ich bin selbst erstaunt wie gut die CODESYS IDE auf einem ARM64 emuliert wird. Ich muss aber auch sagen, dass ich jederzeit eine x64 Workspace zur Verfügung habe, falls was nicht funktionieren sollte. Das habe ich mir extra zum Umstieg zu gelegt. Bisher habe ich es jedoch noch nie benötigt, da meine Anforderungen alle erfüllt werden. Es sollte einem aber bewusst sein, dass dies keine supportete Umgebung ist und man auch bei spezifischen Problemen keinen Support erwarten sollte. Ich nutze CODESYS ca. 4-12 Stunden die Woche und ich warte immer noch auf etwas, um meine X64 Cloud Workspace mal zu verwenden... Vielleicht hilft dir dies ja etwas bei der Entscheidung.
Last updated: 2024-03-21

Post by r-niedermayer on OPC UA subscriber not operational CODESYS Forge talk (Post)
Hi. As far as projects in "old version"s are concerned, these can be upgraded to newer versions at any time. To do this, the device must be updated accordingly and the copilers and library versions must be adapted. You can find instructions on how to proceed in the online help/FAQ: https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_changing_compiler_version.html https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_cmd_update_device.html See also 4.3.22.4 "How to open an Example Project" within the following pdf for more details on the single steps: https://forge.codesys.com/lib/counit/tickets/_discuss/thread/3e991befbc/ca97/attachment/Public%20FAQ-v13-20240610_075228.pdf Regaring your OPCUA connection state always showing just "DISABLED", without knowing both sides of the assembly in detail, one can only approach the problem theoretically. We can give a chekclist on how to proceed: Fist, please recheck the communication settings in the OPC UA connection function block to ensure that the server URL, endpoint URL, and other settings are correct and match the configuration of the OPC UA server. Verify that the OPC UA server is running and accessible. -You can try to connect to the OPC UA server using a separate client, such as UAExpert, to ensure that the issue is not related to the OPC UA server itself. Test the security settings in the OPC UA connection function block to ensure that the correct security policy and certificate are selected. If you are using a dynamic connection to the OPC UA server, probe that the connection settings are correctly configured and that the OPC UA client is able to establish a connection to the OPC UA server. Also, please loock into the log files for any errors related to the OPC UA connection function block, these should be listet there. The log files may also provide additional information about the issue and help you to further troubleshoot the problem. FYI - Please see https://content.helpme-codesys.com/en/CODESYS%20Communication/_cds_obj_data_source_communication_opc_ua_server.html: Her you can finde the Communication settings via OPC UA Server -> layout Browse Live Server: The client connects to the server and detects the existing variables and types. From Information Model The client reads the data structure (layout) of the OPC UA Server from the information model set here and as a result receives the information about available variables and types. A connection to the server is not required. The list contains the information models installed in the OPC UA Information Model Repository. "Read Connection" Settings from IEC Variable (option set): - The connection settings used by the device are not read here from the dialog, but at runtime from the IEC variable specified here. - For this possibility, please see the Using a Dynamic Connection to an OPC UA Server (https://content.helpme-codesys.com/en/CODESYS%20Communication/_comm_use_dynamic_opc_ua_server_comm_settings.html) The settings for the communication of a Client-data source to an OPC UA Server can also be dynamically configured from the IEC code and can also be changed at runtime. For such a purpose, a structure is available in the DatasourceOpcUAServer library (For a description of the OPC UA Server, there is one included in the standard installation of CODESYS, https://content.helpme-codesys.com/en/CODESYS%20Communication/_cds_encrypt_communication_data_sources_opc_ua_client.html)
Last updated: 2024-11-04

Post by fefefede on Get the numer of day CODESYS Forge talk (Post)
Hello i tro to create a program to turn on or off the air condition in relationship temperature and numer of day. I can't get the number of day. I try this after installing SysTime library but this not work and have this error on debug ------ Build started: Application: Device.Sim.Device.Application ------- Typify code... Generate code... [ERROR] giorno_accensione_aria: PLC_PRG Device: PLC Logic: Application: C0032: Cannot convert type 'Unknown type: 'SysTimeCore(TRUE)'' to type 'TIME' [ERROR] giorno_accensione_aria: PLC_PRG Device: PLC Logic: Application: C0035: Program name, function or function block instance expected instead of 'SysTimeCore' [ERROR] giorno_accensione_aria: PLC_PRG Device: PLC Logic: Application: C0032: Cannot convert type 'Unknown type: 'DayOfWeek(CurrentTime)'' to type 'INT' [ERROR] giorno_accensione_aria: PLC_PRG Device: PLC Logic: Application: C0035: Program name, function or function block instance expected instead of 'DayOfWeek' [INFORMATION] giorno_accensione_aria: PLC_PRG Device: PLC Logic: Application: C0181: Related position Build complete -- 4 errors, 0 warnings : No download possible PROGRAM PLC_PRG VAR Temperatura: UDINT; AriaCondizionata: BOOL := FALSE; CurrentDayOfWeek: INT; //Variabile Giorno CurrentTime: TIME; GiornoDellaSettimana: INT; DayOfWeek: INT; END_VAR CurrentTime := SysTimeCore(TRUE); // Ottieni l'ora corrente CurrentDayOfWeek := DayOfWeek(CurrentTime); CASE GiornoDellaSettimana OF 1: // Azioni per Lunedì 2: // Martedì se più 10° accend altrimenti spegni IF Temperatura >= 10 THEN AriaCondizionata := TRUE; ELSE AriaCondizionata := FALSE; END_IF 3: // Mercoledì se più di 50° accendi altrimenti spegni IF Temperatura >=50 THEN AriaCondizionata := TRUE; ELSE AriaCondizionata := FALSE; END_IF 4: // Giovedì se più di 40° accendi altrimenti spegni IF Temperatura >=40 THEN AriaCondizionata := TRUE; ELSE AriaCondizionata := FALSE; END_IF 5: // Venerdì se più di 50° accendi altrimenti spegni IF Temperatura >=50 THEN AriaCondizionata := TRUE; ELSE AriaCondizionata := FALSE; END_IF 6: // Sabato se più di 25° accendi altrimenti spegni IF Temperatura >=25 THEN AriaCondizionata := TRUE; ELSE AriaCondizionata := FALSE; END_IF 7: // Domenica sempre spenta AriaCondizionata := FALSE; END_CASE
Last updated: 2023-09-14

Post by tcarlbom on Read tag values using external program CODESYS Forge talk (Post)
This is my first time posting in this forum and I am new to codesys. I am a fullstack developer and I am trying to figure out how the following. What would be the best approach to create a own/custom tag browser? Either directly in codesys ide or using a separate custom program (perhaps a winforms application). 1.a. Shall I parse the .project xml file to get a list of all tags in the project? 1b. Shall I use python scripting in codesys ide to get a list of tags? Once one have selected some tags. These tags shall be exposed to a python program which will be acting as a edge computer. It’s fine to be able to import a file. 2a. I found a library called codesys plchandler which (as I understand) acts a rest api server. Is this correct? If so, can I query the api from a custom python script, ie can query what tags exist in project and or read tag values? My research so far. From earlier projects I know that using opc ua would be perfect for this but from my opinion it’s bloating the plc since it’s resource intensive. So opc ua is not an option. Codesys automation server is neat. But I don’t want to rely on some cloud services and subscription based pricing. There seem to be several interesting codesys libraries like mqtt, tcp server and NVL sender which would help me expose plc tags. But all have a common problem. One have to manually write what tags which will be used in these function blocks. I want a similar experience like “selecting” tags in the opc ua or the codesys tracing, ie a tag browser.
Last updated: 2024-06-28

Post by youness on No source code available (cip object) CODESYS Forge talk (Post)
Hi yotaro, hope your problem was resolved. I had the same, but with an other library title. This exception is not detected during compilation, but rather at a given position in the program (when switching to a given visualization). Although the exception is generated at this point, it does not involve the visualization in question. This error is due to one of 3 reasons: 1) A division by zero somewhere: The program is able to detect divisions by zero at compile time. But in the case of a variable, which takes a valid value at init and changes to 0 at a later stage. 2) An invalid pointer: (either because it has a value of 0, or because it points outside the memory reserved for the program) is being dereferenced. Locate any pointers or interfaces you have in the code and check them - you should also be wary of mixing inline modifications and pointers. 3) Array overflow: Generally when a processing operation is executed outside the array's definition range. Example: a write loop with n iterations is executed on an array of dimmension n-1. On the other hand, the error message may not appear. In the latter case, the error may have fatal consequences, as the overflow has induced writing to potentially forbidden memory areas. This problem can be explained by the fact that it's not always the adjacent memory areas of PLC_PRG that are overwritten, but the memory areas that are randomly allocated to the array during compilation. In this case, however, there is no entry in the log, so you need to integrate the "Implicit Check function", which checks the line of code generating the error. To integrate this functions, click on Application --> POU for implicit controls Regards,
Last updated: 2024-07-16

Post by yannickasselin on MQTT QoS 1 & 2 CODESYS Forge talk (Post)
Hello, I am using Codesys sp20p3 and IIoT library 1.11. I am trying to test QoS 1 & 2 and I have some issues. I am using mosquitto as the broker. I am also using some other MQTT clients like Node-Red and TwinCAT. They all work as expected for every QoS levels. I only have issues with Codesys MQTT client. In the Codesys client, if I subscribe to a topic as QoS 1 or 2, and a client publishes to this topic, I receive the message. But if I disconnect the Codesys client from the network and a client publishes to the subscribed topic, when I reconnect Codesys client to the network, I don't receive the messages as expected. Also there does not seem to be an auto-reconnect feature. So I have to manually set the mqttClient.xEnable bit to FALSE then back to TRUE in order to reconnect to the broker, then I also have to set the subscribe.xEnable to FALSE and back to TRUE in order to re-subscribe to the topic, but even then, I don't receive the messages that were published while I was disconnected. What am I doing wrong? I set the cleanSession bit to FALSE and I give my client a clientID. With the TwinCAT MQTT Client, I do the same thing and everything works as expected. It even auto-reconnects to the broker. I would expect Codesys MQTT Client to be as reliable as TwinCAT. Maybe I am doing something wrong? I also noticed that when trying to publish a QoS 1 or 2 message while disconnected from the broker, it does not work. In TwinCAT, I am still able to publish. The messages are stored in the client and published once reconnected to the broker. I would expect to be able to do the same thing in Codesys. Is this all possible? Am I doing something wrong? Thank you
Last updated: 2024-10-26

Post by gorditron on I2C Communication with CODESYS Forge talk (Post)
Hello, I have problems with the I2C communication to an ADS7828 AD converter. I don't get any value back from the chip. I use a Kontron chip (ARM 32SC) with Linux as the operating system. I also use the CmpCharDevice library. ADS7828 parameters Address: A1 = 0 / A0 = 0 = SD = 1 = Single End C2 = 0 / C1= 0 / C0= 0 / Channel 0 PD1 = Internal Reference and PD0 = AD Converter ON Here is my code: VAR b_i2cAdr : BYTE := 16#48; (* Standard I2C-Adresse des ADS7828 *) x_Init: BOOL;(* Flag für die Initialisierung *) b_config_byte: BYTE;(* Konfigurationsbyte für den ADS7828 *) ab_cmd_buffer : ARRAY [0..0] OF BYTE; (* Buffer für den Befehl *) ab_data_buffer : ARRAY [0..1] OF BYTE; (* Buffer für die empfangenen Daten *) ui_adc_value_1 : UINT; (* Ausgelesener ADC-Wert *) I2C_Handle: RTS_IEC_HANDLE; (* Handle für das I2C-Device *) di_result_open: DINT;(* Ergebnis der Funktionsaufrufe *) di_result_adr: DINT;(* Ergebnis der Funktionsaufrufe *) di_result_wr_cmd: DINT;(* Ergebnis der Funktionsaufrufe *) di_result_rd_cmd: DINT;(* Ergebnis der Funktionsaufrufe *) di_result_close: DINT;(* Ergebnis der Funktionsaufrufe *) END_VAR //*** Init from the I2C communication port *** IF NOT x_Init THEN I2C_Handle := CDOpen(szFile:= '/dev/i2c-0', dFlags:= O_RDWR, pResult:= ADR(di_result_open)); //* I2C opening * //*** set of the I2C address *** CDIoctl(hFile:=I2C_Handle , dRequest:=1795 , dParameter:=b_i2cAdr , pResult:=ADR(di_result_adr) ); x_Init := TRUE; END_IF (* Hauptlogik *) IF I2C_Handle <> 0 THEN (* Konfigurationsbyte setzen: Single-Ended Kanal 0, interne Referenz *) b_config_byte := 16#8C; (* 10001100b: AIN0, interne Referenz, Single-Ended *) ab_cmd_buffer[0] := b_config_byte; (* Schreiboperation zum Konfigurieren des Chips *) CDWrite(hFile:= I2C_Handle, pbyBuffer:= ADR(ab_cmd_buffer), udCount:= SIZEOF(ab_cmd_buffer), pResult:= ADR(di_result_wr_cmd)); IF di_result_wr_cmd = 0 THEN (* Leseoperation, um den ADC-Wert zu erhalten *) CDRead(hFile:= I2C_Handle, pbyBuffer:= ADR(ab_data_buffer), udCount:= SIZEOF(ab_data_buffer), pResult:= ADR(di_result_rd_cmd)); IF di_result_rd_cmd = 0 THEN (* ADC-Wert aus den Daten extrahieren *) ui_adc_value_1 := SHL(TO_UINT(ab_data_buffer[0]), 8) OR TO_UINT(ab_data_buffer[1]); ELSE (* Fehler beim Lesen der Daten *) ui_adc_value_1 := 0; (* ADC-Wert auf 0 setzen *) END_IF ELSE (* Fehler beim Schreiben der Konfiguration *) ui_adc_value_1 := 0; END_IF END_IF
Last updated: 2024-12-13

Post by spiessli on Raspberry Pi 4 with Legacy Drivers and Codesys 3.5.19 Patch 4 CODESYS Forge talk (Post)
Hi, I wanted to use the Adafruit Hat for the Raspberry and get acquainted with Softmotion using servos for RC models. This did work great with Codesys 3.5.19 Patch 1, but with Patch 4 and 5 i get errors. I suspect changes in the SoftMotion library have broken dependencies in the legacy drivers, might that be true? Thanks for any hint, spiessli Here the error log: ------ Übersetzungslauf gestartet: Applikation: Device.Application ------- Code typisieren... Code erzeugen... [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet Übersetzung abgeschlossen -- 15 Fehler, 0 Warnungen : Kein Download möglich
Last updated: 2023-12-19

Post by gustavocsw on MQTT memory leak problem CODESYS Forge talk (Post)
Hello everyone, I'm using the IoT Library to implement the MQTT communication with my local broker server in order to publish and subscribe at specifics topics to share and consume information about my application. But, it seems that are occurring some memory leak problem in a "high" frequency (more than 10 Hz) subscribe process. I follow the same method as in IoT Lib exemples, and at first looks perfect but my PLC was rebooting frequently and when I check its memory usage that was increasing as fast as the subscribe massage was sent. I'm using a WEG PLC410 and a WEG PLC500, and this error occurred in both of them (including in CODESYS Control Win x64). The application sends to the system a message JSON with the float payload Ex. {"data" : 0.8500}, but this happens with a INT, or BOL as well. I use the follow code in my application to find the value: //FindFirstValueByKey VARs PROGRAM JSON_VELO VAR //------Setting the JSON Subscriber to Set the Relay Value jsonDataVelo : JSON.JSONData; jsonByteArrayReaderVelo : JSON.JSONByteArrayReader; xST1okVelo : BOOL; FindFirstValueByKeyVelo : JSON.FindFirstValueByKey; jsonElementVelo : JSON.JSONElement; xDoneReaderVelo : BOOL; xDoneFindVelo : BOOL; //STRING and WSTRING for Subscribe the massage sPayloadJsonVelo : STRING := 'opa'; psPayloadJsonVelo : POINTER TO BYTE := ADR(sPayloadJsonVelo); //wsPayloadJsonRelaySet : WSTRING := "opa"; wsPayloadJsonVelo : WSTRING := STRING_TO_WSTRING('opa'); pwsPayloadJsonVelo : POINTER TO WORD := ADR(wsPayloadJsonVelo); lrVelo : LREAL; xKeepAliveVelo : BOOL; xSetVelo : BOOL; RSSet : RS; LIMPAR : STRING; //Find the msg end sFindVelo : STRING := '}'; psFindVelo : POINTER TO STRING := ADR(sFindVelo); iLenVelo : INT; iSizeVelo : INT := 12; udiContMsg : UDINT; END_VAR // FindFirstValueByKey CODE // Relay Set configuration xSetVelo := MQTT_SUBSCRIBER.RSVelo.Q1; IF xSetVelo THEN xKeepAliveVelo := TRUE; END_IF IF xKeepAliveVelo THEN udiContMsg := udiContMsg + 1; iLenVelo := TO_INT(StrLenA(psPayloadJsonVelo)); iSizeVelo := iLenVelo - TO_INT(MQTT_SUBSCRIBER.udiPayloadSizeVelo); StrDeleteA(psPayloadJsonVelo,iSizeVelo,iLenVelo); wsPayloadJsonVelo := STRING_TO_WSTRING(sPayloadJsonVelo); pwsPayloadJsonVelo := ADR(wsPayloadJsonVelo); //MQTT.ConvertUTF8toUTF16(sourceStart:= ADR(sPayloadJsonVelo), targetStart:= ADR(wsPayloadJsonVelo), dwTargetBufferSize:= TAM, bStrictConversion:= 1); //Reset jsonByteArrayReader jsonByteArrayReaderVelo ( xExecute := TRUE, pwData := pwsPayloadJsonVelo, jsonData := jsonDataVelo, xDone => xDoneReaderVelo ); FindFirstValueByKeyVelo( xExecute := xDoneReaderVelo, wsKey := "data", diStartIndex:= 0, jsonData := jsonDataVelo, jsonElement => jsonElementVelo, xDone => xDoneFindVelo ); IF xDoneFindVelo THEN lrVelo := jsonElementVelo.value.lrValue; //Reset jsonByteArrayReader jsonByteArrayReaderVelo ( xExecute := FALSE, pwData := pwsPayloadJsonVelo, jsonData := jsonDataVelo, xDone => xDoneReaderVelo ); FindFirstValueByKeyVelo( xExecute := FALSE, wsKey := "data", diStartIndex:= 1, jsonData := jsonDataVelo, jsonElement => jsonElementVelo, xDone => xDoneFindVelo ); xKeepAliveVelo := FALSE; GVL.xSetVeloRead := TRUE; END_IF END_IF And this to subscribe at the topic: //SUBSCRIBE VAR: //----------------- Subscribe Velocity ----------------------- MQTTSubscribeVelo : MQTT.MQTTSubscribe;//Variable MQTTSubscriber block -X - function-X wsTopicSubscribeVelo : WSTRING(1024) := "CORE/odometry/GET/data/simp"; // Topic to publish a message sSubscribeMassageVelo : STRING; udiPayloadSizeVelo : UDINT; xSDoneVelo : BOOL; xSErrorVelo : BOOL; xReceiveVelo : BOOL; eSTypeVelo : MQTT.MQTT_ERROR; eSMQTTErrorVelo : MQTT.MQTT_ERROR; RSVelo : RS; udiCont : UDINT; //SUBSCRIBE CODE: MQTTSubscribeVelo( xEnable:= MQTT_CLIENT.xConnection_Broker AND NOT xSErrorVelo AND NOT JSON_VELO.xKeepAliveVelo, pbPayload:= JSON_VELO.psPayloadJsonVelo, udiMaxPayloadSize:= SIZEOF(JSON_VELO.sPayloadJsonVelo), udiPayloadSize => udiPayloadSizeVelo, mqttClient:= MQTT_CLIENT.ClientMQTT, wsTopicFilter:=wsTopicSubscribeVelo, xDone => xSDoneVelo, xError=> xSErrorVelo, xReceived => xReceiveVelo, eMQTTError=> eSMQTTErrorVelo ); RSVelo(SET := xReceiveVelo, RESET1 := JSON_VELO.xKeepAliveVelo);
Last updated: 2024-09-09

Post by patrik on Wish: CODESYSControl.cfg - again CODESYS Forge talk (Post)
Really good post. I hope that it gets seen by CoDeSys staff. I often find the documentation lacking when it comes to using CoDeSys in more complex ways. If using standard "basic PLC functionality", then it's fine and functions are documented in a sufficient way. Once you go outside of that bubble then I find the documentation not enough. CODESYSControl.cfg is a good example of this. And why isn't more of this integrated in the IDE. like changing port of the webserver. Why is it hidden in this file and not accessible through the IDE. It feels like a layer of complexity purposely left in so you don't change it if you don't know what you are doing. Like the argument is if you have the know-how to find the file you have the know-how to edit it. I find the documentation lacking when it comes to more complex libraries too. Like the element collections library. there is parameters I still don't quite know what they do. I can't find any documentation about them. There is an example project to download from CoDeSys so you can see how you are supposed to set your factories up. I leave some parameters like it is in the example. Should I? I don't know. Does it work. Yes. But I could perhaps create memory leaks if I get something wrong and I don't see that until way later. In the create method of your element factory you have a function called __vfinit and you just have to accept that it works. Why can't I get insight in what it does through documentation? Don't CoDeSys want us to know how these work so we can't use them to accidentally break something? I find the error logging lacking too. I've had the CoDeSys service crash but it doesn't say why. I've seen windows noticing the crash but no error code was sent or error message. Also in my current issue where the application fails to start after power outage. I can see in the log that it fails to load retain in the application as one log entry and application failing to start as another. But why? Why does loading the retain fail? give me more information! Is it just a skill issue with me? I don't know. If it is then I'd still want CoDeSys to step up their game when it comes to documentation. I'm sorry if a lot of frustration comes though in this post. I really like the product and what I can do with it compared to other PLC brands.
Last updated: 2024-11-21

Post by hwillems on Ranges, Lambdas, on Fixed arrays of structs CODESYS Forge talk (Post)
I do datastructures and algorithms in Codesys. For example a Struct of Person with thing's like IdNumber, Name, Age etc. as example. Now i do all kind of calculations, filters. So i have this pretty big Fixed Array with Structs. On this struct i want to do simple stuff you can do easily in C++/Python/Rust etc. For example i want to do this: AvererageAge := Average(Peoples.Age); Then it will return the average of all members ages. Or Sort struct on age etc. Or sort on alphabetical Name. Or use Lambda functions to filter/mutate out things like, filter out everybody above 18 years old. Or remove people who it's name start with "A". Currently i have to write my own custom function for example sorting on Age. And make a super specific function based on that particulare datastructure. Here an Example: (*Before calling this FIlter method, set the mNodeFilterSwitch to the desired filter.*) CASE mNodeFilterSelect OF (********************************[ Status Filters ]***********************************) NodeID: FOR x := ACS_OUT_BEGIN TO ACS_OUT_END BY 1 DO FOR y := ACS_IN_BEGIN TO ACS_IN_END BY 1 DO IF marrNode[y].Status.oiNodeID > marrNode[y + 1].Status.oiNodeID THEN mNodeTemp := marrNode[y + 1]; marrNode[y + 1] := marrNode[y]; marrNode[y] := mNodeTemp; END_IF; END_FOR; END_FOR; Started: FOR x := DES_OUT_BEGIN TO DES_OUT_END BY -1 DO FOR y := DES_IN_BEGIN TO DES_IN_END BY -1 DO IF marrNode[y].Status.oxStarted > marrNode[y - 1].Status.oxStarted THEN mNodeTemp := marrNode[y - 1]; marrNode[y - 1] := marrNode[y]; marrNode[y] := mNodeTemp; END_IF; END_FOR; END_FOR; Starting: FOR x := DES_OUT_BEGIN TO DES_OUT_END BY -1 DO FOR y := DES_IN_BEGIN TO DES_IN_END BY -1 DO IF marrNode[y].Status.oxStarting > marrNode[y - 1].Status.oxStarting THEN mNodeTemp := marrNode[y - 1]; marrNode[y - 1] := marrNode[y]; marrNode[y] := mNodeTemp; END_IF; END_FOR; END_FOR; END_CASE; I have like 30+ of these in the enum. Not really DRY code right? These are custom made bubble sort filters in a function. You pass in the Datastructure, and say what function you want. (This is an enum collection of sorting functions) And then the Array with Nodes of Structs gets ordered. Why can't we have Iterators and Lambda's and build in standard functions like regular languages? Also i use bubble sort because it's the easiest to implement because i can't get this to code DRY. Problem with ST (Even the new one with classes) that it's very limited for programming datastructures and algorithms. Yes you still not want dynamic memory and you need to choose the correct algorithm so you know the most extreme edge cases regarding the time it takes to execute the algorithms.(Real-time execution) How are other people dealing with this? Here for example saw some software using an adjusted ST language and having FOR EACH possibility: https://www.fernhillsoftware.com/help/iec-61131/structured-text/st-for-each.html You can then build your own custom Iterator functions. I wish the IEC 61131-3 standard would be more expressive and having more standard modern features, but still keep close to the fact of no dynamics memory and real-time systems.
Last updated: 2023-08-31

Post by scoob on ModbusFB - Slow Response Time CODESYS Forge talk (Post)
Hello, I have been trying to use the ModbusFB functions so I can put some code into libraries, but it seems to be very slow for me. I have a Modbus device with 100ms registers. I previously setup 10 channels in the 'traditional' Modbus Slave with channels and mappings - and set a cyclic trigger at 100ms - this worked fine. I then tried the ModbusFB example, and setup reading the same 10 blocks of modbus addresses, copying the example and putting all of the requests into an array and triggering the requests sequentially. I timed how long the requests are taking to get round to each one, and it is around 1s 450ms. How do I speed this up to match the cyclic time? IF NOT(init) THEN init := TRUE; // Set the required IP address: ipAddress[0] := 192; ipAddress[1] := 168; ipAddress[2] := 1; ipAddress[3] := 10; // Pass the required IP address to the clinet FB: client_NetworkSwitch.aIPaddr := ipAddress; client_NetworkSwitch.udiLogOptions := (ModbusFB.LoggingOptions.ClientConnectDisconnect OR ModbusFB.LoggingOptions.ClientReceivedValidReplies); // Try to connect the client client_NetworkSwitch(xConnect:=TRUE); // Configure all the channels to read connecting them to the client: portStatus_Request(rClient := client_NetworkSwitch, uiStartItem := 4096, uiQuantity := 32, pData := ADR(portStatus), udiReplyTimeout := udiReplyTimeout); portSpeed_Request(rClient := client_NetworkSwitch, uiStartItem := 4352, uiQuantity := 32, pData := ADR(portSpeed)); flowControl_Request(rClient := client_NetworkSwitch, uiStartItem := 4608, uiQuantity := 32, pData := ADR(flowControl)); linkUpCounter_Request(rClient := client_NetworkSwitch, uiStartItem := 5888, uiQuantity := 32, pData := ADR(linkUpCounter)); txPacketCounter1_Request(rClient := client_NetworkSwitch, uiStartItem := 8192, uiQuantity := 100, pData := ADR(txPacketCounter1)); txPacketCounter2_Request(rClient := client_NetworkSwitch, uiStartItem := 8292, uiQuantity := 28, pData := ADR(txPacketCounter2)); rxPacketCounter1_Request(rClient := client_NetworkSwitch, uiStartItem := 8448, uiQuantity := 100, pData := ADR(rxPacketCounter1)); rxPacketCounter2_Request(rClient := client_NetworkSwitch, uiStartItem := 8548, uiQuantity := 28, pData := ADR(rxPacketCounter2)); txErrors_Request(rClient := client_NetworkSwitch, uiStartItem := 8704, uiQuantity := 64, pData := ADR(txErrors)); rxErrors_Request(rClient := client_NetworkSwitch, uiStartItem := 8960, uiQuantity := 64, pData := ADR(rxErrors)); // Trigger all client requests initially FOR clientRequestsCnt := 0 TO (SIZEOF(clientRequests)/SIZEOF(clientRequests[0]))-1 DO pClientRequest := clientRequests[clientRequestsCnt]; pClientRequest^.xExecute := TRUE; END_FOR // Prepare sequential trigger / control of client requests. clientRequestsCnt := 0; pClientRequest := clientRequests[clientRequestsCnt]; END_IF // Call the client to do request processing: client_NetworkSwitch(); // Now we trigger client request sequentially ... IF NOT pClientRequest^.xExecute AND NOT pClientRequest^.xDone AND run AND client_NetworkSwitch.xConnected THEN pClientRequest^.xExecute := TRUE; END_IF // .. and check result/error IF pClientRequest^.xExecute AND run AND client_NetworkSwitch.xConnected THEN IF pClientRequest^.xDone THEN // Prepare next trigger of client request (a rising edge of xExecute) pClientRequest^.xExecute := FALSE; IF clientRequestsCnt < SIZEOF(clientRequests)/SIZEOF(clientRequests[0])-1 THEN // next client request clientRequestsCnt := clientRequestsCnt + 1; ELSE clientRequestsIterationCounter := clientRequestsIterationCounter + 1; clientRequestsCnt := 0; END_IF pClientRequest := clientRequests[clientRequestsCnt]; END_IF END_IF I did try a semi-coded way using the IoDrvModbusTCP library, and setting the slave com settings, then 10 commands and 10 requests, then using a TP on xDone as a pause, before triggering another request - this is time the delay is around 120ms - so the device is fine with the speed, just something I am doing wrong in the ModbusFB method I am sure.
Last updated: 2024-04-26

Post by derpaul on Official MQTT-Client: MAX_RECEIVE_BUFFER_SIZE_EXCEEDED CODESYS Forge talk (Post)
Here is the output Codesyscontrol.log ;**************************************************************** ;<loggername>/tmp/codesyscontrol.log</loggername> ;<logoptions> ; <enable>1</enable> ; <type>normal</type> ; <timestamp>rtc</timestamp> ; <deactivatable>0</deactivatable> ; <dump>always</dump> ; <filter>0x0000000f<filter> ; <maxentries>1000</maxentries> ; <maxfiles>1</maxfiles> ; <maxfilesize>1000000</maxfilesize> ;</logoptions> ;<entries> ;Timestamp, CmpId, ClassId, ErrorId, InfoId, InfoText ;ClassId: LOG_INFO =1 ;ClassId: LOG_WARNING =2 ;ClassId: LOG_ERROR =4 ;ClassId: LOG_EXCEPTION =8 ;ClassId: LOG_DEBUG =16 ;ClassId: LOG_PRINTF =32 ;ClassId: LOG_COM =64 ;</entries> ;**************************************************************** 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, <logoptions> 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, <bEnable>1</bEnable> 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, <type>normal</type> 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, <timestamp>rtc</timestamp> 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, <disableable>0</disableable> 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, <Filter>0x0000000f</Filter> 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, <MaxEntries>1000</MaxEntries> 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, <MaxFiles>1</MaxFiles> 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, <MaxFileSize>1000000</MaxFileSize> 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, </logoptions> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 4, CODESYS Control for PFC200 SL 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 4, OS=Linux, CPU=ARM, Arch=32Bit, Coding=C 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 6, <version>3.5.16.40</version> <builddate>Mar 2 2021</builddate> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 5, Copyright (c) 3S - Smart Software Solutions GmbH 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>CM</cmp>, <id>0x00000001</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>CmpMemPool</cmp>, <id>0x0000001e</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>CmpLog</cmp>, <id>0x00000013</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>CmpSettings</cmp>, <id>0x0000001a</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysFile</cmp>, <id>0x00000104</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysCom</cmp>, <id>0x00000100</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysCpuHandling</cmp>, <id>0x00000101</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysDir</cmp>, <id>0x0000011b</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysEthernet</cmp>, <id>0x0000011c</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysEvent</cmp>, <id>0x00000102</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysExcept</cmp>, <id>0x00000103</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysInternalLib</cmp>, <id>0x00000107</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysMem</cmp>, <id>0x00000108</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysModule</cmp>, <id>0x00000109</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysMsgQ</cmp>, <id>0x0000010a</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysMutex</cmp>, <id>0x0000013a</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysOut</cmp>, <id>0x0000010b</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysProcess</cmp>, <id>0x0000010e</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysSem</cmp>, <id>0x0000010f</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysSemCount</cmp>, <id>0x00000139</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysSemProcess</cmp>, <id>0x00000119</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysShm</cmp>, <id>0x00000110</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysSocket</cmp>, <id>0x00000111</id> <ver>3.5.16.30</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysTarget</cmp>, <id>0x00000112</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysTask</cmp>, <id>0x00000114</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysTime</cmp>, <id>0x00000115</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysTimeRtc</cmp>, <id>0x00000127</id> <ver>3.5.16.30</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysTimer</cmp>, <id>0x00000116</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpAlarmManager</cmp>, <id>0x0000007c</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpApp</cmp>, <id>0x00000002</id> <ver>3.5.16.30</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpAppBP</cmp>, <id>0x00000073</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpAppForce</cmp>, <id>0x00000074</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpAsyncMgr</cmp>, <id>0x0000005f</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpBinTagUtil</cmp>, <id>0x00000004</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpBinTagUtilIec</cmp>, <id>0x0000005c</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpBitmapPool</cmp>, <id>0x00000050</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpBlkDrvTcp</cmp>, <id>0x00000030</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpBlkDrvUdp</cmp>, <id>0x00000007</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAAAsyncMan</cmp>, <id>0x00004007</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAABehaviourModel</cmp>, <id>0x00004015</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAACallback</cmp>, <id>0x00004001</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAACanL2</cmp>, <id>0x00004004</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAADTUtil</cmp>, <id>0x00004013</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAAFile</cmp>, <id>0x00004008</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAAMemBlockMan</cmp>, <id>0x00004003</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAANetBaseServices</cmp>, <id>0x00004018</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAARealTimeClock</cmp>, <id>0x00004014</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAASdoClient</cmp>, <id>0x00004011</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAASdoServer</cmp>, <id>0x00004017</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAASegBufferMan</cmp>, <id>0x00004019</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAASerialCom</cmp>, <id>0x00004012</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAAStorage</cmp>, <id>0x0000007e</id> <ver>3.5.16.30</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAATick</cmp>, <id>0x00004009</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAATickUtil</cmp>, <id>0x00004010</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAATimer</cmp>, <id>0x00004016</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAATypes</cmp>, <id>0x00004006</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpChannelClient</cmp>, <id>0x00000008</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpChannelClientIec</cmp>, <id>0x0000005d</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpChannelMgr</cmp>, <id>0x00000009</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpChannelServer</cmp>, <id>0x0000000a</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCharDevice</cmp>, <id>0x00000300</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpChecksum</cmp>, <id>0x0000000b</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCodeMeter</cmp>, <id>0x0000007a</id> <ver>3.5.16.30</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCommunicationLib</cmp>, <id>0x0000000c</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCoreDump</cmp>, <id>0x00000083</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCryptMD5</cmp>, <id>0x0000006a</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpDevice</cmp>, <id>0x0000000e</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpDynamicText</cmp>, <id>0x00000051</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpEL6751CanDrv</cmp>, <id>0x00005f0b</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpEventMgr</cmp>, <id>0x0000005b</id> <ver>3.5.16.30</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpFileTransfer</cmp>, <id>0x0000005e</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpIecStringUtils</cmp>, <id>0x0000007f</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpIecTask</cmp>, <id>0x00000011</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpIecVarAccess</cmp>, <id>0x00000060</id> <ver>3.5.16.30</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpIoDrvIec</cmp>, <id>0x0000005a</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpIoMgr</cmp>, <id>0x00000012</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpKbus</cmp>, <id>0x0000008a</id> <ver>4.0.1.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpKnxStack</cmp>, <id>0x0000004d</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpMonitor2</cmp>, <id>0x00000032</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpNameServiceClient</cmp>, <id>0x00000015</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpNameServiceClientIec</cmp>, <id>0x0000011d</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpNameServiceServer</cmp>, <id>0x00000016</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpOPCUAClient</cmp>, <id>0x00000096</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpOPCUAProviderIecVarAccess</cmp>, <id>0x00000126</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpOPCUAServer</cmp>, <id>0x00000124</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpOPCUAStack</cmp>, <id>0x0000008d</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpOpenSSL</cmp>, <id>0x00000033</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpPfcx00</cmp>, <id>0x00000088</id> <ver>4.0.1.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpPlcShell</cmp>, <id>0x00000128</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpRedundancy</cmp>, <id>0x00000129</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpRedundancyConnectionIP</cmp>, <id>0x0000ff03</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpRetain</cmp>, <id>0x00000017</id> <ver>3.5.16.30</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpRouter</cmp>, <id>0x00000018</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpSchedule</cmp>, <id>0x00000019</id> <ver>3.5.16.30</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpSecureChannel</cmp>, <id>0x00000090</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpSecurityManager</cmp>, <id>0x0000008e</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpSessionInformation</cmp>, <id>0x00000097</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpSocketCanDrv</cmp>, <id>0x00005f0d</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpSrv</cmp>, <id>0x0000001c</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpTraceMgr</cmp>, <id>0x00000070</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpUserDBFile</cmp>, <id>0x00000098</id> <ver>3.5.16.20</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpUserGroupsDBFile</cmp>, <id>0x00000099</id> <ver>3.5.16.20</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpUserMgr</cmp>, <id>0x00000061</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpUserObjectsDBFile</cmp>, <id>0x0000009c</id> <ver>3.5.16.20</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpVisuHandler</cmp>, <id>0x00000054</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpVisuServer</cmp>, <id>0x00000057</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpWebServer</cmp>, <id>0x00000071</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpWebServerHandlerV3</cmp>, <id>0x00000072</id> <ver>3.5.16.0</ver> 2023-09-12T21:12:16Z, 0x00000007, 1, 0, 6, Network interface: <ipaddress>192.168.1.17</ipaddress>, subnetmask <subnetmask>255.255.255.0</subnetmask> 2023-09-12T21:12:16Z, 0x00000018, 1, 0, 4, Network interface <interface>ether 4</interface> at router <instance>0</instance> registered 2023-09-12T21:12:16Z, 0x00000009, 1, 0, 2, Running as network server 2023-09-12T21:12:16Z, 0x00000009, 1, 0, 1, Running as network client 2023-09-12T21:12:16Z, 0x0000000a, 1, 0, 0, <NumOfChannels>4</NumOfChannels> channels available, each of the size <BufferSize>100000</BufferSize> Bytes 2023-09-12T21:12:16Z, 0x00000129, 1, 0, 0, Debug Messages not activated 2023-09-12T21:12:16Z, 0x0000ff03, 1, 0, 0, Read connection settings... 2023-09-12T21:12:16Z, 0x00000030, 1, 0, 6, Local network address: <ipaddress>192.168.1.17</ipaddress> 2023-09-12T21:12:16Z, 0x00000018, 1, 0, 4, Network interface <interface>BlkDrvTcp</interface> at router <instance>2</instance> registered 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, No certificate for the OPC UA server available. 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, Security policy allows plain text communication. Secure communication is deactivated. 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, ************************************************************** 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, OPC UA Server Started: 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, Hostname: PFC200, Port: 4840 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, URL: opc.tcp://PFC200:4840 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, Loopbackadapter activated. 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, All available networkadapters are used. 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, ************************************************************** 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, Provider CODESYS_DefaultProvider with Version 0x3051028 registerd at the OPC UA server. 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, Provider CmpOPCUAProviderIecVarAccess with Version 0x3051028 registerd at the OPC UA server. 2023-09-12T21:12:17Z, 0x00000126, 1, 0, 0, Valid license found for OPC UA IecVarAccess provider. 2023-09-12T21:12:17Z, 0x00000002, 1, 0, 7, Retains matched to bootproject of application [<app>Application</app>] 2023-09-12T21:12:17Z, 0x00000002, 1, 0, 6, Bootproject of application [<app>Application</app>] loaded 2023-09-12T21:12:17Z, 0x00000018, 1, 0, 1, Setting router <instance>0</instance> address to <address>(0011)</address> 2023-09-12T21:12:17Z, 0x00000018, 1, 16, 8, Network interface for mainnet=<mainnet>ether 5</mainnet> not found 2023-09-12T21:12:17Z, 0x00000018, 1, 0, 1, Setting router <instance>1</instance> address to <address>(0000)</address> 2023-09-12T21:12:17Z, 0x00000018, 1, 0, 1, Setting router <instance>2</instance> address to <address>(2ddc:c0a8:0111)</address> 2023-09-12T21:12:17Z, 0x00000002, 1, 0, 10, Application [<app>Application</app>] started 2023-09-12T21:12:17Z, 0x00000001, 1, 0, 34, CODESYS Control ready 2023-09-12T21:13:37Z, 0x00000001, 1, 0, 0, runtime licensed 2023-09-12T21:17:17Z, 0x00000002, 1, 0, 2, Application [<app>Application</app>] loaded via [OnlineChange] 2023-09-13T01:38:17Z, 0x00000009, 1, 418, 0, Channel timeout (<curtime>16012264</curtime>, <lasttime>15982259</lasttime>) 2023-09-13T01:38:17Z, 0x00000009, 1, 418, 0, Closing connection to <address>0329:032e</address> 2023-09-23T14:46:00Z, 0x00000002, 1, 0, 2, Application [<app>Application</app>] loaded via [OnlineChange] 2023-09-23T14:48:57Z, 0x00000002, 1, 0, 2, Application [<app>Application</app>] loaded via [OnlineChange]
Last updated: 2023-09-27

Post by frank1001 on Codesys läuft nicht hoch CODESYS Forge talk (Post)
Bin Neuling bei Codesys. Habe Codesys 64 Bit installiert (3.5.1) Nach dem Starten geht nur ein EIngabefenster auf mit folgenden Inhalt. Weiter passiert nichts. Was kann ich machen ? //////////////////////////////////////////////////////////// //////////////////////////////////////////////////////////// _/_/_/_/ _/_/_/_/ _/_/_/_/_/ _/_/_/_/_/_/ _/_/_/_/_/ _/_/ _/_/ _/_/_/_/_/ _/ _/_/_/_/_/_/ _/_/_/_/_/_/ _/_/_/_/_/_/ _/_/_/_/_/_/ _/_/_/_/_/_/ _/_/ _/_/ _/_/_/_/_/_/ _/_/_/ _/_/ _/_/ _/_/ _/_/ _/_/ _/_/ _/_/ _/_/ _/_/ _/_/ _/_/ _/_/_/_/_/ // // // // // //// //// //// //// /////// // // // // // // // // // // ///// ////// ////// ////// ////// ////// // ////// /// //// //// ///// ////// ///// // ///// _/ //////////////////////////////////////////////////////////// //////////////////////////////////////////////////////////// 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>CM</cmp>, <id>0x00000001</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>CmpMemPool</cmp>, <id>0x0000001e</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>CmpLog</cmp>, <id>0x00000013</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>CmpSettings</cmp>, <id>0x0000001a</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysFile</cmp>, <id>0x00000104</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>CmpMemGC</cmp>, <id>0x0000001f</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysCom</cmp>, <id>0x00000100</id> <ver>3.5.19.10</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysCpuBreakpoints</cmp>, <id>0x00000305</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysCpuHandling</cmp>, <id>0x00000101</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysCrypto</cmp>, <id>0x00000141</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysDir</cmp>, <id>0x0000011b</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysEthernet</cmp>, <id>0x0000011c</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysEvent</cmp>, <id>0x00000102</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysExcept</cmp>, <id>0x00000103</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysFileStream</cmp>, <id>0x00000120</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysGraphicGDIPlus</cmp>, <id>0x0000012a</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysInt</cmp>, <id>0x00000106</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysInternalLib</cmp>, <id>0x00000107</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysMem</cmp>, <id>0x00000108</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysModule</cmp>, <id>0x00000109</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysMsgQ</cmp>, <id>0x0000010a</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysMutex</cmp>, <id>0x0000013a</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysNativeCommonControls</cmp>, <id>0x00000138</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysNativeControl</cmp>, <id>0x0000012f</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysOut</cmp>, <id>0x0000010b</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysPci</cmp>, <id>0x0000010c</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysPort</cmp>, <id>0x0000010d</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysProcess</cmp>, <id>0x0000010e</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysSem</cmp>, <id>0x0000010f</id> <ver>3.5.19.10</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysSemCount</cmp>, <id>0x00000139</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysSemProcess</cmp>, <id>0x00000119</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysShm</cmp>, <id>0x00000110</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysSocket</cmp>, <id>0x00000111</id> <ver>3.5.19.10</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysTarget</cmp>, <id>0x00000112</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysTask</cmp>, <id>0x00000114</id> <ver>3.5.19.10</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysTime</cmp>, <id>0x00000115</id> <ver>3.5.19.10</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysTimeRtc</cmp>, <id>0x00000127</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysTimer</cmp>, <id>0x00000116</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysWindow</cmp>, <id>0x00000117</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysWindowFileDialog</cmp>, <id>0x0000011a</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System|Dynamic: <cmp>SysTargetSoftMotion</cmp>, <id>0x00000112</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System|Dynamic: <cmp>SysCpuMultiCore</cmp>, <id>0x0000013d</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System|Dynamic: <cmp>SysReadWriteLock</cmp>, <id>0x0000013e</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpAlarmManager</cmp>, <id>0x0000007c</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpApp</cmp>, <id>0x00000002</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpAppBP</cmp>, <id>0x00000073</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpAppForce</cmp>, <id>0x00000074</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpAsyncMgr</cmp>, <id>0x0000005f</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpAuditLog</cmp>, <id>0x000000a1</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpBinTagUtil</cmp>, <id>0x00000004</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpBinTagUtilIec</cmp>, <id>0x0000005c</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpBitmapPool</cmp>, <id>0x00000050</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpBlkDrvCom</cmp>, <id>0x00000006</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpBlkDrvShm</cmp>, <id>0x00000068</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpBlkDrvTcp</cmp>, <id>0x00000030</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpBlkDrvUdp</cmp>, <id>0x00000007</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAAAsyncMan</cmp>, <id>0x00004007</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAABehaviourModel</cmp>, <id>0x00004015</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAACallback</cmp>, <id>0x00004001</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAACanL2</cmp>, <id>0x00004004</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAADTUtil</cmp>, <id>0x00004013</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAAFile</cmp>, <id>0x00004008</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAAMemBlockMan</cmp>, <id>0x00004003</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAANetBaseServices</cmp>, <id>0x00004018</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAARealTimeClock</cmp>, <id>0x00004014</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAASdoClient</cmp>, <id>0x00004011</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAASdoServer</cmp>, <id>0x00004017</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAASegBufferMan</cmp>, <id>0x00004019</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAASerialCom</cmp>, <id>0x00004012</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAAStorage</cmp>, <id>0x0000007e</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAATick</cmp>, <id>0x00004009</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAATickUtil</cmp>, <id>0x00004010</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAATimer</cmp>, <id>0x00004016</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAATypes</cmp>, <id>0x00004006</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpChannelClient</cmp>, <id>0x00000008</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpChannelClientIec</cmp>, <id>0x0000005d</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpChannelMgr</cmp>, <id>0x00000009</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpChannelServer</cmp>, <id>0x0000000a</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpChecksum</cmp>, <id>0x0000000b</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCodeMeter</cmp>, <id>0x0000007a</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCommunicationLib</cmp>, <id>0x0000000c</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCoreDump</cmp>, <id>0x00000083</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCryptMD5</cmp>, <id>0x0000006a</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpDevice</cmp>, <id>0x0000000e</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpDynamicText</cmp>, <id>0x00000051</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpEventMgr</cmp>, <id>0x0000005b</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpFileTransfer</cmp>, <id>0x0000005e</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpIecStringUtils</cmp>, <id>0x0000007f</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpIecTask</cmp>, <id>0x00000011</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpIecVarAccess</cmp>, <id>0x00000060</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpIoDrvC</cmp>, <id>0x00000066</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpIoDrvIec</cmp>, <id>0x0000005a</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpIoMgr</cmp>, <id>0x00000012</id> <ver>3.5.19.10</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpIpc</cmp>, <id>0x0000001d</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpMonitor</cmp>, <id>0x00000014</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpMonitor2</cmp>, <id>0x00000032</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpNameServiceClient</cmp>, <id>0x00000015</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpNameServiceClientIec</cmp>, <id>0x0000011d</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpNameServiceServer</cmp>, <id>0x00000016</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpOPCUAClient</cmp>, <id>0x00000096</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpOPCUAProviderIecVarAccess</cmp>, <id>0x00000126</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpOPCUAServer</cmp>, <id>0x00000124</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpOPCUAStack</cmp>, <id>0x0000008d</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpObjectMgr</cmp>, <id>0x00000080</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpOpenSSL</cmp>, <id>0x00000033</id> <ver>3.5.19.10</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpPlcShell</cmp>, <id>0x00000128</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpRedundancy</cmp>, <id>0x00000129</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpRedundancyConnectionIP</cmp>, <id>0x0000ff03</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpRetain</cmp>, <id>0x00000017</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpRouter</cmp>, <id>0x00000018</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpSchedule</cmp>, <id>0x00000019</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpSecureChannel</cmp>, <id>0x00000090</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpSecurityManager</cmp>, <id>0x0000008e</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpSercos3Master</cmp>, <id>0x0000004c</id> <ver>3.1.2.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpSessionInformation</cmp>, <id>0x00000097</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpSrv</cmp>, <id>0x0000001c</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpSupervisor</cmp>, <id>0x0000008f</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpTraceMgr</cmp>, <id>0x00000070</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpUserDBFile</cmp>, <id>0x00000098</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpUserGroupsDBFile</cmp>, <id>0x00000099</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpUserMgr</cmp>, <id>0x00000061</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpUserObjectsDBFile</cmp>, <id>0x0000009c</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpVisuClientControllerHost</cmp>, <id>0x00000132</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpVisuHandler</cmp>, <id>0x00000054</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpVisuServer</cmp>, <id>0x00000057</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpXMLParser</cmp>, <id>0x00000058</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= Dynamic: <cmp>CmpTargetVisuStub</cmp>, <id>0x00000053</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= Dynamic: <cmp>CmpWebServer</cmp>, <id>0x00000071</id> <ver>3.5.19.10</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= Dynamic: <cmp>CmpWebServerHandlerV3</cmp>, <id>0x00000072</id> <ver>3.5.19.10</ver> 2023-09-19T08:02:04.045Z: Cmp=SysCpuMultiCore, Class=1, Error=0, Info=4, pszInfo= MultiCore support: [activated], all cores are used 2023-09-19T08:02:04.045Z: Cmp=SysCpuMultiCore, Class=1, Error=0, Info=4, pszInfo= Number of available cores: 8 2023-09-19T08:02:04.076Z: Cmp=CmpBlkDrvUdp, Class=1, Error=0, Info=6, pszInfo= Network interface: <ipaddress>192.168.1.167</ipaddress>, subnetmask <subnetmask>255.255.255.0</subnetmask> 2023-09-19T08:02:04.076Z: Cmp=CmpRouter, Class=1, Error=0, Info=4, pszInfo= Network interface <interface>ether 0</interface> at router <instance>0</instance> registered 2023-09-19T08:02:04.076Z: Cmp=CmpBlkDrvUdp, Class=1, Error=0, Info=6, pszInfo= Network interface: <ipaddress>192.168.56.1</ipaddress>, subnetmask <subnetmask>255.255.255.0</subnetmask> 2023-09-19T08:02:04.076Z: Cmp=CmpRouter, Class=1, Error=0, Info=4, pszInfo= Network interface <interface>ether 3</interface> at router <instance>1</instance> registered 2023-09-19T08:02:04.076Z: Cmp=CmpChannelMgr, Class=1, Error=0, Info=2, pszInfo= Running as network server 2023-09-19T08:02:04.076Z: Cmp=CmpChannelMgr, Class=1, Error=0, Info=1, pszInfo= Running as network client 2023-09-19T08:02:04.077Z: Cmp=CmpChannelServer, Class=1, Error=0, Info=0, pszInfo= <numofchannels>4</numofchannels> channels available, each of the size <buffersize>100000</buffersize> Bytes 2023-09-19T08:02:04.265Z: Cmp=CmpRedundancy, Class=1, Error=0, Info=0, pszInfo= Debug Messages not activated 2023-09-19T08:02:04.266Z: Cmp=CmpRedundancyConnectionIP, Class=1, Error=0, Info=0, pszInfo= Read connection settings... 2023-09-19T08:02:05.456Z: Cmp=CmpRouter, Class=1, Error=0, Info=4, pszInfo= Network interface <interface>BlkDrvShm</interface> at router <instance>2</instance> registered 2023-09-19T08:02:05.456Z: Cmp=CmpBlkDrvShm, Class=1, Error=0, Info=9, pszInfo= Local address (BlkDrvShm) set to 1 2023-09-19T08:02:05.463Z: Cmp=CmpBlkDrvTcp, Class=1, Error=0, Info=6, pszInfo= Local network address: <ipaddress>192.168.56.1</ipaddress> 2023-09-19T08:02:05.464Z: Cmp=CmpRouter, Class=1, Error=0, Info=4, pszInfo= Network interface <interface>BlkDrvTcp</interface> at router <instance>3</instance> registered 2023-09-19T08:02:05.507Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= No certificate for the OPC UA server available. 2023-09-19T08:02:05.507Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= Security policy allows plain text communication. Secure communication is deactivated. 2023-09-19T08:02:05.508Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= ********** 2023-09-19T08:02:05.508Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= OPC UA Server Started: 2023-09-19T08:02:05.508Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= Hostname: SIEMENS, Port: 4840 2023-09-19T08:02:05.508Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= URL: opc.tcp://SIEMENS:4840 2023-09-19T08:02:05.508Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= Loopbackadapter activated. 2023-09-19T08:02:05.508Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= All available networkadapters are used. 2023-09-19T08:02:05.508Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= Multithreading activated. 7 workers used. 2023-09-19T08:02:05.508Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= ************ 2023-09-19T08:02:05.513Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= Provider 'CODESYS_DefaultProvider' (version 0x3051300) registered at the OPC UA server. 2023-09-19T08:02:05.522Z: Cmp=CM, Class=1, Error=0, Info=0, pszInfo= ========================================================================= 2023-09-19T08:02:05.522Z: Cmp=CM, Class=1, Error=0, Info=4, pszInfo= CODESYS SoftMotion Win V3 x64 2023-09-19T08:02:05.522Z: Cmp=CM, Class=1, Error=0, Info=4, pszInfo= OS=Windows, CPU=x86, Arch=64Bit, Coding=C 2023-09-19T08:02:05.522Z: Cmp=CM, Class=1, Error=0, Info=6, pszInfo= <version>3.5.19.20</version> <builddate>Aug 1 2023</builddate> 2023-09-19T08:02:05.522Z: Cmp=CM, Class=1, Error=0, Info=5, pszInfo= Copyright CODESYS Development GmbH 2023-09-19T08:02:05.522Z: Cmp=CM, Class=1, Error=0, Info=0, pszInfo= ========================================================================= 2023-09-19T08:02:05.529Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= Provider 'AddressSpaceFragment Provider' (version 0x3051314) registered at the OPC UA server. 2023-09-19T08:02:05.530Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= Provider 'OPC UA for IEC-61131-3' (version 0x3051314) registered at the OPC UA server. 2023-09-19T08:02:05.530Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= Provider 'AlarmManager' (version 0x3051314) registered at the OPC UA server. 2023-09-19T08:02:05.606Z: Cmp=CmpRouter, Class=1, Error=0, Info=1, pszInfo= Setting router <instance>0</instance> address to (00a7) 2023-09-19T08:02:05.606Z: Cmp=CmpRouter, Class=1, Error=0, Info=1, pszInfo= Setting router <instance>1</instance> address to (0001) 2023-09-19T08:02:05.606Z: Cmp=CmpRouter, Class=1, Error=0, Info=1, pszInfo= Setting router <instance>2</instance> address to (0001) 2023-09-19T08:02:05.606Z: Cmp=CmpRouter, Class=1, Error=0, Info=1, pszInfo= Setting router <instance>3</instance> address to (2ddc:c0a8:3801) 2023-09-19T08:02:05.611Z: Cmp=CM, Class=1, Error=0, Info=34, pszInfo= CODESYS Control ready 2023-09-19T08:02:05.796Z: Cmp=CM, Class=2, Error=0, Info=0, pszInfo=!!!! no runtime license - running in demo mode(~2 hours)
Last updated: 2023-09-19

Post by svenkaro on Codesyscontrol.service stoppt nach 30s CODESYS Forge talk (Post)
Hallo nano, anbei das Logfile ;********* ;<loggername>codesyscontrol.log</loggername> ;<logoptions> ; <enable>1</enable> ; <type>normal</type> ; <timestamp>rtc high resolution</timestamp> ; <deactivatable>0</deactivatable> ; <dump>always</dump> ; <filter>0x0000000f<filter> ; <maxentries>100000</maxentries> ; <maxfiles>1</maxfiles> ; <maxfilesize>1000000</maxfilesize> ;</filter></filter></logoptions> ;<entries> ;Timestamp, CmpId, ClassId, ErrorId, InfoId, InfoText ;ClassId: LOG_INFO =1 ;ClassId: LOG_WARNING =2 ;ClassId: LOG_ERROR =4 ;ClassId: LOG_EXCEPTION =8 ;ClassId: LOG_DEBUG =16 ;ClassId: LOG_PRINTF =32 ;ClassId: LOG_COM =64 ;</entries> ;********* 2024-06-20T06:07:12.085Z, 0x0000013d, 16, 0, 0, OpenCpusetCpusEffective: using core(s) "0-3" from /sys/fs/cgroup/cpuset.cpus.effective 2024-06-20T06:07:12.085Z, 0x00000109, 16, 0, 0, SysModuleLoad: libCmpBACnet.so: 0x92ae530 2024-06-20T06:07:12.085Z, 0x00000109, 16, 0, 0, SysModuleLoad: libCmpBACnet2.so: 0x92af008 2024-06-20T06:07:12.085Z, 0x00000109, 16, 0, 0, SysModuleLoad: libCmpPLCHandler.so: 0x92afb08 2024-06-20T06:07:12.085Z, 0x00000109, 16, 0, 0, SysModuleLoad: libCmpGwClient.so: 0x92affe8 2024-06-20T06:07:12.085Z, 0x00000109, 16, 0, 0, SysModuleLoad: libCmpXMLParser.so: 0x92b04c0 2024-06-20T06:07:12.085Z, 0x00000109, 16, 0, 0, SysModuleLoad: libCmpGwClientCommDrvTcp.so: 0x92b09a0 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, <logoptions> 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, <benable>1</benable> 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, <type>normal</type> 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, <timestamp>rtc high resolution</timestamp> 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, <disableable>0</disableable> 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, <filter>0x0000000f</filter> 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, <maxentries>100000</maxentries> 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, <maxfiles>1</maxfiles> 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, <maxfilesize>1000000</maxfilesize> 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, </logoptions> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>CM</cmp>, <id>0x00000001</id> <ver>3.5.19.61</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>CmpMemPool</cmp>, <id>0x0000001e</id> <ver>3.5.19.60</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>CmpLog</cmp>, <id>0x00000013</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>CmpSettings</cmp>, <id>0x0000001a</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysFile</cmp>, <id>0x00000104</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>CmpMemGC</cmp>, <id>0x0000001f</id> <ver>3.5.19.20</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysCom</cmp>, <id>0x00000100</id> <ver>3.5.19.10</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysCpuHandling</cmp>, <id>0x00000101</id> <ver>3.5.19.20</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysCpuMultiCore</cmp>, <id>0x0000013d</id> <ver>3.5.19.20</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysCrypto</cmp>, <id>0x00000141</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysDir</cmp>, <id>0x0000011b</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysEthernet</cmp>, <id>0x0000011c</id> <ver>3.5.19.20</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysEvent</cmp>, <id>0x00000102</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysExcept</cmp>, <id>0x00000103</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysInternalLib</cmp>, <id>0x00000107</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysMem</cmp>, <id>0x00000108</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysModule</cmp>, <id>0x00000109</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysMsgQ</cmp>, <id>0x0000010a</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysMutex</cmp>, <id>0x0000013a</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysOut</cmp>, <id>0x0000010b</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysProcess</cmp>, <id>0x0000010e</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysSem</cmp>, <id>0x0000010f</id> <ver>3.5.19.10</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysSemCount</cmp>, <id>0x00000139</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysSemProcess</cmp>, <id>0x00000119</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysShm</cmp>, <id>0x00000110</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysSocket</cmp>, <id>0x00000111</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysTarget</cmp>, <id>0x00000112</id> <ver>3.5.19.61</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysTask</cmp>, <id>0x00000114</id> <ver>3.5.19.10</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysTime</cmp>, <id>0x00000115</id> <ver>3.5.19.10</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysTimeRtc</cmp>, <id>0x00000127</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysTimer</cmp>, <id>0x00000116</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpAlarmManager</cmp>, <id>0x0000007c</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpApp</cmp>, <id>0x00000002</id> <ver>3.5.19.60</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpAppBP</cmp>, <id>0x00000073</id> <ver>3.5.19.20</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpAppForce</cmp>, <id>0x00000074</id> <ver>3.5.19.20</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpAsyncMgr</cmp>, <id>0x0000005f</id> <ver>3.5.19.20</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpAuditLog</cmp>, <id>0x000000a1</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpBinTagUtil</cmp>, <id>0x00000004</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpBinTagUtilIec</cmp>, <id>0x0000005c</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpBitmapPool</cmp>, <id>0x00000050</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpBlkDrvTcp</cmp>, <id>0x00000030</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpBlkDrvUdp</cmp>, <id>0x00000007</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAAAsyncMan</cmp>, <id>0x00004007</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAABehaviourModel</cmp>, <id>0x00004015</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAACallback</cmp>, <id>0x00004001</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAACanL2</cmp>, <id>0x00004004</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAADTUtil</cmp>, <id>0x00004013</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAAFile</cmp>, <id>0x00004008</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAAMemBlockMan</cmp>, <id>0x00004003</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAANetBaseServices</cmp>, <id>0x00004018</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAARealTimeClock</cmp>, <id>0x00004014</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAASdoClient</cmp>, <id>0x00004011</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAASdoServer</cmp>, <id>0x00004017</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAASegBufferMan</cmp>, <id>0x00004019</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAASerialCom</cmp>, <id>0x00004012</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAAStorage</cmp>, <id>0x0000007e</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAATick</cmp>, <id>0x00004009</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAATickUtil</cmp>, <id>0x00004010</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAATimer</cmp>, <id>0x00004016</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAATypes</cmp>, <id>0x00004006</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpChannelClient</cmp>, <id>0x00000008</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpChannelClientIec</cmp>, <id>0x0000005d</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpChannelMgr</cmp>, <id>0x00000009</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpChannelServer</cmp>, <id>0x0000000a</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCharDevice</cmp>, <id>0x00000300</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpChecksum</cmp>, <id>0x0000000b</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCodeMeter</cmp>, <id>0x0000007a</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCommunicationLib</cmp>, <id>0x0000000c</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCoreDump</cmp>, <id>0x00000083</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCryptMD5</cmp>, <id>0x0000006a</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpDevice</cmp>, <id>0x0000000e</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpDynamicText</cmp>, <id>0x00000051</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpEL6751CanDrv</cmp>, <id>0x00005f0b</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpEventMgr</cmp>, <id>0x0000005b</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpEventMgrUnixBackend</cmp>, <id>0x000000a4</id> <ver>4.11.0.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpFileTransfer</cmp>, <id>0x0000005e</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpIecStringUtils</cmp>, <id>0x0000007f</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpIecTask</cmp>, <id>0x00000011</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpIecVarAccess</cmp>, <id>0x00000060</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpIoDrvIec</cmp>, <id>0x0000005a</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpIoMgr</cmp>, <id>0x00000012</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpKnxStack</cmp>, <id>0x0000004d</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpLinuxInterrupt</cmp>, <id>0x000000a2</id> <ver>3.5.17.10</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpLinuxRTDiag</cmp>, <id>0x000000a7</id> <ver>4.11.0.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpMonitor2</cmp>, <id>0x00000032</id> <ver>3.5.19.20</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpNameServiceClient</cmp>, <id>0x00000015</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpNameServiceClientIec</cmp>, <id>0x0000011d</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpNameServiceServer</cmp>, <id>0x00000016</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpOPCUAClient</cmp>, <id>0x00000096</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpOPCUAProviderIecVarAccess</cmp>, <id>0x00000126</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpOPCUAServer</cmp>, <id>0x00000124</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpOPCUAStack</cmp>, <id>0x0000008d</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpOpenSSL</cmp>, <id>0x00000033</id> <ver>3.5.19.61</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpPlcShellLinux</cmp>, <id>0x00000128</id> <ver>4.11.0.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpPlcShellLinuxBackend</cmp>, <id>0x000000a5</id> <ver>4.11.0.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpRasPi</cmp>, <id>0x00000089</id> <ver>4.11.0.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpRedundancy</cmp>, <id>0x00000129</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpRedundancyConnectionIP</cmp>, <id>0x0000ff03</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpRetain</cmp>, <id>0x00000017</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpRouter</cmp>, <id>0x00000018</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpRunStopSwitch</cmp>, <id>0x000000a6</id> <ver>4.11.0.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpSchedule</cmp>, <id>0x00000019</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpSecureChannel</cmp>, <id>0x00000090</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpSecurityManager</cmp>, <id>0x0000008e</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpSessionInformation</cmp>, <id>0x00000097</id> <ver>3.5.19.20</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpSocketCanDrv</cmp>, <id>0x00005f0d</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpSocketUnix</cmp>, <id>0x000000a3</id> <ver>4.11.0.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpSrv</cmp>, <id>0x0000001c</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpTraceMgr</cmp>, <id>0x00000070</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpUserDBFile</cmp>, <id>0x00000098</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpUserGroupsDBFile</cmp>, <id>0x00000099</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpUserMgr</cmp>, <id>0x00000061</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpUserObjectsDBFile</cmp>, <id>0x0000009c</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpVisuHandler</cmp>, <id>0x00000054</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpVisuServer</cmp>, <id>0x00000057</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpWebServer</cmp>, <id>0x00000071</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpWebServerHandlerV3</cmp>, <id>0x00000072</id> <ver>3.5.19.10</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, Dynamic: <cmp>CmpBACnet</cmp>, <id>0x00000400</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, Dynamic: <cmp>CmpBACnet2</cmp>, <id>0x00000401</id> <ver>3.5.19.10</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, Dynamic: <cmp>CmpPLCHandler</cmp>, <id>0x0000002a</id> <ver>3.5.19.61</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, Dynamic: <cmp>CmpGwClient</cmp>, <id>0x00000021</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, Dynamic: <cmp>CmpXMLParser</cmp>, <id>0x00000058</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, Dynamic: <cmp>CmpGwClientCommDrvTcp</cmp>, <id>0x00000022</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.125Z, 0x0000013d, 1, 0, 4, MultiCore support: [activated], all cores are used 2024-06-20T06:07:12.125Z, 0x0000013d, 1, 0, 4, Number of available cores: 4 2024-06-20T06:07:12.134Z, 0x00000401, 2, 0, 0, !!!! Warning: component CmpBACnet loaded already 2024-06-20T06:07:12.184Z, 0x00000007, 1, 0, 6, Network interface: <ipaddress>10.94.25.39</ipaddress>, subnetmask <subnetmask>255.255.255.0</subnetmask> 2024-06-20T06:07:12.184Z, 0x00000018, 1, 0, 4, Network interface <interface>ether 2</interface> at router <instance>0</instance> registered 2024-06-20T06:07:12.185Z, 0x00000009, 1, 0, 2, Running as network server 2024-06-20T06:07:12.185Z, 0x00000009, 1, 0, 1, Running as network client 2024-06-20T06:07:12.186Z, 0x0000000a, 1, 0, 0, <numofchannels>4</numofchannels> channels available, each of the size <buffersize>100000</buffersize> Bytes 2024-06-20T06:07:12.254Z, 0x00000400, 1, 0, 0, CmpBACnet 1024 BACstack information 2024-06-20T06:07:12.254Z, 0x00000400, 1, 0, 0, version = 15.0.1.1 2024-06-20T06:07:12.254Z, 0x00000400, 1, 0, 0, __BYTE_ORDER = 1234 2024-06-20T06:07:12.254Z, 0x00000400, 1, 0, 0, TARGET_IEEE_FP_FORMAT = 1 2024-06-20T06:07:12.254Z, 0x00000400, 1, 0, 0, TARGET_FP_BIG_ENDIAN = 0 2024-06-20T06:07:12.254Z, 0x00000400, 1, 0, 0, TARGET_DP_BIG_ENDIAN = 0 2024-06-20T06:07:12.254Z, 0x00000400, 1, 0, 0, TARGET_INTEGRAL_BIG_ENDIAN = 0 2024-06-20T06:07:12.254Z, 0x00000400, 1, 0, 0, TARGET_USED_ALIGNMENT = 4 2024-06-20T06:07:12.254Z, 0x00000401, 1, 0, 0, CmpBACnet2 1025 BACstack information 2024-06-20T06:07:12.254Z, 0x00000401, 1, 0, 0, version = 25.1.5.1 2024-06-20T06:07:12.254Z, 0x00000401, 1, 0, 0, __BYTE_ORDER = 1234 2024-06-20T06:07:12.254Z, 0x00000401, 1, 0, 0, TARGET_IEEE_FP_FORMAT = 1 2024-06-20T06:07:12.254Z, 0x00000401, 1, 0, 0, TARGET_FP_BIG_ENDIAN = 0 2024-06-20T06:07:12.254Z, 0x00000401, 1, 0, 0, TARGET_DP_BIG_ENDIAN = 0 2024-06-20T06:07:12.254Z, 0x00000401, 1, 0, 0, TARGET_INTEGRAL_BIG_ENDIAN = 0 2024-06-20T06:07:12.254Z, 0x00000401, 1, 0, 0, TARGET_MCU_USED_ALIGNMENT = 4 2024-06-20T06:07:12.261Z, 0x00000129, 1, 0, 0, Debug Messages not activated 2024-06-20T06:07:12.262Z, 0x0000ff03, 1, 0, 0, Read connection settings... 2024-06-20T06:07:12.266Z, 0x00000030, 1, 0, 6, Local network address: <ipaddress>10.94.25.39</ipaddress> 2024-06-20T06:07:12.266Z, 0x00000018, 1, 0, 4, Network interface <interface>BlkDrvTcp</interface> at router <instance>1</instance> registered 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, No certificate for the OPC UA server available. 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, Security policy allows plain text communication. Secure communication is deactivated. 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, ********** 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, OPC UA Server Started: 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, Hostname: raspberrypi, Port: 4840 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, URL: opc.tcp://raspberrypi:4840 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, Loopbackadapter activated. 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, All available networkadapters are used. 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, Multithreading activated. 3 workers used. 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, ************ 2024-06-20T06:07:12.286Z, 0x00000124, 1, 0, 0, Provider 'CODESYS_DefaultProvider' (version 0x305131e) registered at the OPC UA server. 2024-06-20T06:07:12.287Z, 0x000000a6, 1, 0, 0, Not able to read file of Run/Stop switch. Functionality of component disabled 2024-06-20T06:07:12.306Z, 0x00000001, 1, 0, 0, ========================================================================= 2024-06-20T06:07:12.306Z, 0x00000001, 1, 0, 4, CODESYS Control for Raspberry Pi MC SL 2024-06-20T06:07:12.306Z, 0x00000001, 1, 0, 4, OS=Linux, CPU=ARM, Arch=32Bit, Coding=C 2024-06-20T06:07:12.306Z, 0x00000001, 1, 0, 6, <version>3.5.19.61</version> <builddate>Feb 22 2024</builddate> 2024-06-20T06:07:12.306Z, 0x00000001, 1, 0, 5, Copyright CODESYS Development GmbH 2024-06-20T06:07:12.306Z, 0x00000001, 1, 0, 0, ========================================================================= 2024-06-20T06:07:12.308Z, 0x00000124, 1, 0, 0, Provider 'AddressSpaceFragment Provider' (version 0x3051332) registered at the OPC UA server. 2024-06-20T06:07:12.309Z, 0x00000124, 1, 0, 0, Provider 'OPC UA for IEC-61131-3' (version 0x3051332) registered at the OPC UA server. 2024-06-20T06:07:12.309Z, 0x00000124, 1, 0, 0, Provider 'AlarmManager' (version 0x3051332) registered at the OPC UA server. 2024-06-20T06:07:12.321Z, 0x00000018, 1, 0, 1, Setting router <instance>0</instance> address to (0027) 2024-06-20T06:07:12.321Z, 0x00000018, 1, 0, 1, Setting router <instance>1</instance> address to (2ddc:0a5e:1927) 2024-06-20T06:07:12.332Z, 0x00000001, 1, 0, 34, CODESYS Control ready 2024-06-20T06:07:12.333Z, 0x00000001, 2, 0, 0, !!!! Warning: no runtime license - running in demo mode(~2 hours) Wäre der Zeitraum nicht nur 30s könnte ich das beenden auf Grund der letzten Zeile nachvollziehen. Hoffe Du hast eine Idee, vielen Dank.
Last updated: 2024-06-20

<< < 1 .. 41 42 43 (Page 43 of 43)