Post by blitz on Can't get SMC_SmoothPath to work
CODESYS Forge
talk
(Post)
This code works well: PROGRAM PLC_PRG VAR execute : BOOL; abort : BOOL; doMDI : BOOL; manualDataInput : STRING(1024) := 'N5 G01 X0.00 Y200.00 N6 G01 X200.00 Y200.00 N7 G01 X200.00 Y0.00 N8 G01 X0.00 Y0.00'; stringStreamArray: ARRAY[0..NUMBER_OF_CHAINS-1] OF SMC_StringStream2 ; i : UDINT; readNCFromStream : SMC_ReadNCFromStream; sentencesFromStringSteam : SMC_GSentenceQueue ; interpreter : SMC_NCInterpreter; interpreterGeoInfoBuffer: ARRAY[1..GEO_INFO_BUFFERS_SIZE] OF SMC_GeoInfo; roundPath : SMC_RoundPath; roundPathGeoInfoBuffer: ARRAY[1..GEO_INFO_BUFFERS_SIZE] OF SMC_GeoInfo; END_VAR VAR CONSTANT MDI_FILE_NAME : STRING := 'MDI.nc'; NUMBER_OF_CHAINS : UDINT := 15; GEO_INFO_BUFFERS_SIZE : DINT := 500; END_VAR readNCFromStream.bExecute := interpreter.bExecute := roundPath.bExecute := execute; readNCFromStream.bAbort := interpreter.bAbort := roundPath.bAbort := abort; IF doMDI THEN stringStreamArray[0].Init(MDI_FILE_NAME); stringStreamArray[0].AppendData(manualDataInput); stringStreamArray[0].SetEndOfData(); i := 0 ; WHILE i < NUMBER_OF_CHAINS DO readNCFromStream.aStream[i] := stringStreamArray[i]; i := i + 1 ; END_WHILE readNCFromStream.bExecute := TRUE; IF readNCFromStream.bBusy THEN ; END_IF END_IF readNCFromStream( fDefaultVel := 10, fDefaultAccel := 10, fDefaultDecel := 10, fDefaultVelFF := 10, fDefaultAccelFF := 10, fDefaultDecelFF := 10, sentences := sentencesFromStringSteam ); interpreter( sentences:= sentencesFromStringSteam, nSizeOutQueue:= SIZEOF(interpreterGeoInfoBuffer), pbyBufferOutQueue:= ADR(interpreterGeoInfoBuffer)); roundPath( poqDataIn := interpreter.poqDataOut, dRadius := , dAngleTol := , nSizeOutQueue := SIZEOF(roundPathGeoInfoBuffer), pbyBufferOutQueue := ADR(roundPathGeoInfoBuffer));
Last updated: 2026-01-09
Post by frank1001 on Codesys läuft nicht hoch
CODESYS Forge
talk
(Post)
Bin Neuling bei Codesys. Habe Codesys 64 Bit installiert (3.5.1) Nach dem Starten geht nur ein EIngabefenster auf mit folgenden Inhalt. Weiter passiert nichts. Was kann ich machen ? //////////////////////////////////////////////////////////// //////////////////////////////////////////////////////////// _/_/_/_/ _/_/_/_/ _/_/_/_/_/ _/_/_/_/_/_/ _/_/_/_/_/ _/_/ _/_/ _/_/_/_/_/ _/ _/_/_/_/_/_/ _/_/_/_/_/_/ _/_/_/_/_/_/ _/_/_/_/_/_/ _/_/_/_/_/_/ _/_/ _/_/ _/_/_/_/_/_/ _/_/_/ _/_/ _/_/ _/_/ _/_/ _/_/ _/_/ _/_/ _/_/ _/_/ _/_/ _/_/ _/_/_/_/_/ // // // // // //// //// //// //// /////// // // // // // // // // // // ///// ////// ////// ////// ////// ////// // ////// /// //// //// ///// ////// ///// // ///// _/ //////////////////////////////////////////////////////////// //////////////////////////////////////////////////////////// 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>CM</cmp>, <id>0x00000001</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>CmpMemPool</cmp>, <id>0x0000001e</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>CmpLog</cmp>, <id>0x00000013</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>CmpSettings</cmp>, <id>0x0000001a</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysFile</cmp>, <id>0x00000104</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>CmpMemGC</cmp>, <id>0x0000001f</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysCom</cmp>, <id>0x00000100</id> <ver>3.5.19.10</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysCpuBreakpoints</cmp>, <id>0x00000305</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysCpuHandling</cmp>, <id>0x00000101</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysCrypto</cmp>, <id>0x00000141</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysDir</cmp>, <id>0x0000011b</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysEthernet</cmp>, <id>0x0000011c</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysEvent</cmp>, <id>0x00000102</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysExcept</cmp>, <id>0x00000103</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysFileStream</cmp>, <id>0x00000120</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysGraphicGDIPlus</cmp>, <id>0x0000012a</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysInt</cmp>, <id>0x00000106</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysInternalLib</cmp>, <id>0x00000107</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysMem</cmp>, <id>0x00000108</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysModule</cmp>, <id>0x00000109</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysMsgQ</cmp>, <id>0x0000010a</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysMutex</cmp>, <id>0x0000013a</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysNativeCommonControls</cmp>, <id>0x00000138</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysNativeControl</cmp>, <id>0x0000012f</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysOut</cmp>, <id>0x0000010b</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysPci</cmp>, <id>0x0000010c</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysPort</cmp>, <id>0x0000010d</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysProcess</cmp>, <id>0x0000010e</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysSem</cmp>, <id>0x0000010f</id> <ver>3.5.19.10</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysSemCount</cmp>, <id>0x00000139</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysSemProcess</cmp>, <id>0x00000119</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysShm</cmp>, <id>0x00000110</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysSocket</cmp>, <id>0x00000111</id> <ver>3.5.19.10</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysTarget</cmp>, <id>0x00000112</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysTask</cmp>, <id>0x00000114</id> <ver>3.5.19.10</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysTime</cmp>, <id>0x00000115</id> <ver>3.5.19.10</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysTimeRtc</cmp>, <id>0x00000127</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysTimer</cmp>, <id>0x00000116</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysWindow</cmp>, <id>0x00000117</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysWindowFileDialog</cmp>, <id>0x0000011a</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System|Dynamic: <cmp>SysTargetSoftMotion</cmp>, <id>0x00000112</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System|Dynamic: <cmp>SysCpuMultiCore</cmp>, <id>0x0000013d</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System|Dynamic: <cmp>SysReadWriteLock</cmp>, <id>0x0000013e</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpAlarmManager</cmp>, <id>0x0000007c</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpApp</cmp>, <id>0x00000002</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpAppBP</cmp>, <id>0x00000073</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpAppForce</cmp>, <id>0x00000074</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpAsyncMgr</cmp>, <id>0x0000005f</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpAuditLog</cmp>, <id>0x000000a1</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpBinTagUtil</cmp>, <id>0x00000004</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpBinTagUtilIec</cmp>, <id>0x0000005c</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpBitmapPool</cmp>, <id>0x00000050</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpBlkDrvCom</cmp>, <id>0x00000006</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpBlkDrvShm</cmp>, <id>0x00000068</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpBlkDrvTcp</cmp>, <id>0x00000030</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpBlkDrvUdp</cmp>, <id>0x00000007</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAAAsyncMan</cmp>, <id>0x00004007</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAABehaviourModel</cmp>, <id>0x00004015</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAACallback</cmp>, <id>0x00004001</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAACanL2</cmp>, <id>0x00004004</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAADTUtil</cmp>, <id>0x00004013</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAAFile</cmp>, <id>0x00004008</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAAMemBlockMan</cmp>, <id>0x00004003</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAANetBaseServices</cmp>, <id>0x00004018</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAARealTimeClock</cmp>, <id>0x00004014</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAASdoClient</cmp>, <id>0x00004011</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAASdoServer</cmp>, <id>0x00004017</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAASegBufferMan</cmp>, <id>0x00004019</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAASerialCom</cmp>, <id>0x00004012</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAAStorage</cmp>, <id>0x0000007e</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAATick</cmp>, <id>0x00004009</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAATickUtil</cmp>, <id>0x00004010</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAATimer</cmp>, <id>0x00004016</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAATypes</cmp>, <id>0x00004006</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpChannelClient</cmp>, <id>0x00000008</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpChannelClientIec</cmp>, <id>0x0000005d</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpChannelMgr</cmp>, <id>0x00000009</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpChannelServer</cmp>, <id>0x0000000a</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpChecksum</cmp>, <id>0x0000000b</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCodeMeter</cmp>, <id>0x0000007a</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCommunicationLib</cmp>, <id>0x0000000c</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCoreDump</cmp>, <id>0x00000083</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCryptMD5</cmp>, <id>0x0000006a</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpDevice</cmp>, <id>0x0000000e</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpDynamicText</cmp>, <id>0x00000051</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpEventMgr</cmp>, <id>0x0000005b</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpFileTransfer</cmp>, <id>0x0000005e</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpIecStringUtils</cmp>, <id>0x0000007f</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpIecTask</cmp>, <id>0x00000011</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpIecVarAccess</cmp>, <id>0x00000060</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpIoDrvC</cmp>, <id>0x00000066</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpIoDrvIec</cmp>, <id>0x0000005a</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpIoMgr</cmp>, <id>0x00000012</id> <ver>3.5.19.10</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpIpc</cmp>, <id>0x0000001d</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpMonitor</cmp>, <id>0x00000014</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpMonitor2</cmp>, <id>0x00000032</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpNameServiceClient</cmp>, <id>0x00000015</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpNameServiceClientIec</cmp>, <id>0x0000011d</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpNameServiceServer</cmp>, <id>0x00000016</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpOPCUAClient</cmp>, <id>0x00000096</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpOPCUAProviderIecVarAccess</cmp>, <id>0x00000126</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpOPCUAServer</cmp>, <id>0x00000124</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpOPCUAStack</cmp>, <id>0x0000008d</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpObjectMgr</cmp>, <id>0x00000080</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpOpenSSL</cmp>, <id>0x00000033</id> <ver>3.5.19.10</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpPlcShell</cmp>, <id>0x00000128</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpRedundancy</cmp>, <id>0x00000129</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpRedundancyConnectionIP</cmp>, <id>0x0000ff03</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpRetain</cmp>, <id>0x00000017</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpRouter</cmp>, <id>0x00000018</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpSchedule</cmp>, <id>0x00000019</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpSecureChannel</cmp>, <id>0x00000090</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpSecurityManager</cmp>, <id>0x0000008e</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpSercos3Master</cmp>, <id>0x0000004c</id> <ver>3.1.2.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpSessionInformation</cmp>, <id>0x00000097</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpSrv</cmp>, <id>0x0000001c</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpSupervisor</cmp>, <id>0x0000008f</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpTraceMgr</cmp>, <id>0x00000070</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpUserDBFile</cmp>, <id>0x00000098</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpUserGroupsDBFile</cmp>, <id>0x00000099</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpUserMgr</cmp>, <id>0x00000061</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpUserObjectsDBFile</cmp>, <id>0x0000009c</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpVisuClientControllerHost</cmp>, <id>0x00000132</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpVisuHandler</cmp>, <id>0x00000054</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpVisuServer</cmp>, <id>0x00000057</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpXMLParser</cmp>, <id>0x00000058</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= Dynamic: <cmp>CmpTargetVisuStub</cmp>, <id>0x00000053</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= Dynamic: <cmp>CmpWebServer</cmp>, <id>0x00000071</id> <ver>3.5.19.10</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= Dynamic: <cmp>CmpWebServerHandlerV3</cmp>, <id>0x00000072</id> <ver>3.5.19.10</ver> 2023-09-19T08:02:04.045Z: Cmp=SysCpuMultiCore, Class=1, Error=0, Info=4, pszInfo= MultiCore support: [activated], all cores are used 2023-09-19T08:02:04.045Z: Cmp=SysCpuMultiCore, Class=1, Error=0, Info=4, pszInfo= Number of available cores: 8 2023-09-19T08:02:04.076Z: Cmp=CmpBlkDrvUdp, Class=1, Error=0, Info=6, pszInfo= Network interface: <ipaddress>192.168.1.167</ipaddress>, subnetmask <subnetmask>255.255.255.0</subnetmask> 2023-09-19T08:02:04.076Z: Cmp=CmpRouter, Class=1, Error=0, Info=4, pszInfo= Network interface <interface>ether 0</interface> at router <instance>0</instance> registered 2023-09-19T08:02:04.076Z: Cmp=CmpBlkDrvUdp, Class=1, Error=0, Info=6, pszInfo= Network interface: <ipaddress>192.168.56.1</ipaddress>, subnetmask <subnetmask>255.255.255.0</subnetmask> 2023-09-19T08:02:04.076Z: Cmp=CmpRouter, Class=1, Error=0, Info=4, pszInfo= Network interface <interface>ether 3</interface> at router <instance>1</instance> registered 2023-09-19T08:02:04.076Z: Cmp=CmpChannelMgr, Class=1, Error=0, Info=2, pszInfo= Running as network server 2023-09-19T08:02:04.076Z: Cmp=CmpChannelMgr, Class=1, Error=0, Info=1, pszInfo= Running as network client 2023-09-19T08:02:04.077Z: Cmp=CmpChannelServer, Class=1, Error=0, Info=0, pszInfo= <numofchannels>4</numofchannels> channels available, each of the size <buffersize>100000</buffersize> Bytes 2023-09-19T08:02:04.265Z: Cmp=CmpRedundancy, Class=1, Error=0, Info=0, pszInfo= Debug Messages not activated 2023-09-19T08:02:04.266Z: Cmp=CmpRedundancyConnectionIP, Class=1, Error=0, Info=0, pszInfo= Read connection settings... 2023-09-19T08:02:05.456Z: Cmp=CmpRouter, Class=1, Error=0, Info=4, pszInfo= Network interface <interface>BlkDrvShm</interface> at router <instance>2</instance> registered 2023-09-19T08:02:05.456Z: Cmp=CmpBlkDrvShm, Class=1, Error=0, Info=9, pszInfo= Local address (BlkDrvShm) set to 1 2023-09-19T08:02:05.463Z: Cmp=CmpBlkDrvTcp, Class=1, Error=0, Info=6, pszInfo= Local network address: <ipaddress>192.168.56.1</ipaddress> 2023-09-19T08:02:05.464Z: Cmp=CmpRouter, Class=1, Error=0, Info=4, pszInfo= Network interface <interface>BlkDrvTcp</interface> at router <instance>3</instance> registered 2023-09-19T08:02:05.507Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= No certificate for the OPC UA server available. 2023-09-19T08:02:05.507Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= Security policy allows plain text communication. Secure communication is deactivated. 2023-09-19T08:02:05.508Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= ********** 2023-09-19T08:02:05.508Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= OPC UA Server Started: 2023-09-19T08:02:05.508Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= Hostname: SIEMENS, Port: 4840 2023-09-19T08:02:05.508Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= URL: opc.tcp://SIEMENS:4840 2023-09-19T08:02:05.508Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= Loopbackadapter activated. 2023-09-19T08:02:05.508Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= All available networkadapters are used. 2023-09-19T08:02:05.508Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= Multithreading activated. 7 workers used. 2023-09-19T08:02:05.508Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= ************ 2023-09-19T08:02:05.513Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= Provider 'CODESYS_DefaultProvider' (version 0x3051300) registered at the OPC UA server. 2023-09-19T08:02:05.522Z: Cmp=CM, Class=1, Error=0, Info=0, pszInfo= ========================================================================= 2023-09-19T08:02:05.522Z: Cmp=CM, Class=1, Error=0, Info=4, pszInfo= CODESYS SoftMotion Win V3 x64 2023-09-19T08:02:05.522Z: Cmp=CM, Class=1, Error=0, Info=4, pszInfo= OS=Windows, CPU=x86, Arch=64Bit, Coding=C 2023-09-19T08:02:05.522Z: Cmp=CM, Class=1, Error=0, Info=6, pszInfo= <version>3.5.19.20</version> <builddate>Aug 1 2023</builddate> 2023-09-19T08:02:05.522Z: Cmp=CM, Class=1, Error=0, Info=5, pszInfo= Copyright CODESYS Development GmbH 2023-09-19T08:02:05.522Z: Cmp=CM, Class=1, Error=0, Info=0, pszInfo= ========================================================================= 2023-09-19T08:02:05.529Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= Provider 'AddressSpaceFragment Provider' (version 0x3051314) registered at the OPC UA server. 2023-09-19T08:02:05.530Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= Provider 'OPC UA for IEC-61131-3' (version 0x3051314) registered at the OPC UA server. 2023-09-19T08:02:05.530Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= Provider 'AlarmManager' (version 0x3051314) registered at the OPC UA server. 2023-09-19T08:02:05.606Z: Cmp=CmpRouter, Class=1, Error=0, Info=1, pszInfo= Setting router <instance>0</instance> address to (00a7) 2023-09-19T08:02:05.606Z: Cmp=CmpRouter, Class=1, Error=0, Info=1, pszInfo= Setting router <instance>1</instance> address to (0001) 2023-09-19T08:02:05.606Z: Cmp=CmpRouter, Class=1, Error=0, Info=1, pszInfo= Setting router <instance>2</instance> address to (0001) 2023-09-19T08:02:05.606Z: Cmp=CmpRouter, Class=1, Error=0, Info=1, pszInfo= Setting router <instance>3</instance> address to (2ddc:c0a8:3801) 2023-09-19T08:02:05.611Z: Cmp=CM, Class=1, Error=0, Info=34, pszInfo= CODESYS Control ready 2023-09-19T08:02:05.796Z: Cmp=CM, Class=2, Error=0, Info=0, pszInfo=!!!! no runtime license - running in demo mode(~2 hours)
Last updated: 2023-09-19
Post by wiresplus on How to Connect / Go Online without re-downloading the project
CODESYS Forge
talk
(Post)
Hello, I have a PLC in a remote location. I can connect to it, but when I use a different PC, it asks me to re-download to the PLC - which will a) interrupt production and b) cause version issues. Codesys being open-source, if someone else has made changes, I need to be able to connect, upload the current project, compare it with mine and then decide what next. Every time I connect, it says Warning: An application 'Application' is currently in RUN mode on the PLC. As there is no matching compile information, this existing application needs to be replaced. Click 'Yes' to download the latest code or 'No' to abort. What am I doing wrong?
Last updated: 2024-04-13
Post by mubeta on Some 'pathetic' errors in SoftMotion program
CODESYS Forge
talk
(Post)
Yes, this is the error the sometimes show up. What make me crazy is the fact that it happens randomly and not each times. I know very well where the problem is, in wich one program row it's located. For each actions of the state machine I have all events recorded with log on text file. it is not problematic for me to find the application point of the fault, but I need to understand why occasionally and for no apparent reason, switching the state machine and thus changing the motion FB, sends the axis into failure (but only occasionally). For example, one case that is often problematic is the execution of the Axis Halt instruction. When, after a MoveAbosulte instruction this returns the event as 'done' and indeed the axis is in standstill, the state machine first sets the move instruction to FALSE, and the next cycle sets the Halt request to TRUE. Some of the time everything works out fine. Occasionally, however, in this exchange, the axis goes into fault, also losing the OPERATIONAL state. Meanwhile, I would like to understand why the motion FB instances must still be called even after the Execute is set to FALSE, especially in view of the fact that the next instruction is programmed to abort the previous one, with BufferMode set to 'Aborting'. All these unnecessary FB calls are an unnecessary overhead on the CPU anyway. Is there any precise rule about when to cease calling the various instances? (It should precisely be the 'done' status that says this one has finished its work).
Last updated: 2024-07-18
Post by macros8 on Alarm Management - latched variable represented as Text list
CODESYS Forge
talk
(Post)
Hi, I haven´t noticed you put the comment here. I thing it´s a bit different. What I want is to have detail errors of technology in data type e.g. INT. This variable I would latch to the corresponding error msg but I would like to get it convert to text from the text list and not keep it in INT form. Example. Main error Valve Error: SubErrors 1 - Both sensors 2 - Not retracted in time 3 - Not pulled out in time In HMI Main error + latch SubErrors => "Valve Error: Both sensors" The benefit is that text lists are part of translation and can be easily manipulated. I know I can create whole string msg in PLC but then, it lose advantage of Alarm management. Thanks. M.
Last updated: 2023-11-07
Post by alimans on OPC-UA Server, Symbol Set: Raise an error: Object reference not set to an instance of an object.
CODESYS Forge
talk
(Post)
Hi everyone, I just created a very simple library without any code and, added it to my very simple project. after adding this library, I get an error when I try to open "Symbol Set" in "OPC UA Server" in "Communication Manager". Here is the code of my POU in the library: FUNCTION_BLOCK POU VAR eCommand : (CMD_NONE:=0, CMD_RESET:=-1) INT := CMD_NONE; END_VAR Attached is the error that I get. I also noticed that by removing the enumeration variable above (eCommand), I can open the "Symbol Set" again. Anybody has any idea why this error is raised and how could I use enumeration variables without error in "OPC UA Symbol Set"?
Last updated: 2024-08-08
Post by alsiddhartha on TextList name error (fake)
CODESYS Forge
talk
(Post)
Hello, I’m developing a program and for some reason I got this error: C0193: Name '2,Recipe #2GVL' is no valid identifier I was creating a combo box and creating a TextList for my recipe. I couldn't find where the error was, until in the combo box properties in the 'Text List' property in the options it gives me to select, I found '2,Recipe #2' to be able to select (I never created a list with this name) and I can't find a way to delete that option or I can't find where that list is. I tried to delete the TextLists, delete the combo box, to clean the project, but the error still there. How can I delete this option (2,Recipe #2)? Or how can I fix this error?** Thank you.
Last updated: 2025-06-19
Post by pethun on Upgrade from codesys 3.5.19 to 3.5.20
CODESYS Forge
talk
(Post)
Hi We upgraded our ptoject from 3.5.19 to 3.5.20 but we get an error message in the latest version. We made our own trend function and its related to this we get error message: Trend_Menu Device: PLC Logic: Application: C0032: Cannot convert type 'RTS_SYSTIMEDATE(systimertc, 3.5.20.0 (system))' to type 'RTS_SYSTIMEDATE(systimertc, 3.5.17.0 (system))' The variables are defined as follow: start : SysTimeRtc.SYSTIMEDATE; end : SysTimeRtc.SYSTIMEDATE; The code that creates the error is the variable start and end IF xAssign THEN xAssign := FALSE; xPanEnable := FALSE; xZoomEnable := FALSE; drs.liFrom := VisuTrendStorageAccess.TrendStorageConvertToTimestamp(start, 0 (us)); drs.liTo := VisuTrendStorageAccess.TrendStorageConvertToTimestamp(end, 0 (us)); drs.m_itfDateRangeSelectorClient.SetCurrentRange(drs.liFrom, drs.liTo); END_IF I cant understand really what the error message means and what can be the cause of the error? It compiles fine in dthe older codesys 3.5.19. If anyone has some experience of this please help us out? We must upgrade due to the new licenses. Thanks
Last updated: 2024-04-20
Post by pethun on Upgrade from codesys 3.5.19 to 3.5.20
CODESYS Forge
talk
(Post)
Hi We upgraded our ptoject from 3.5.19 to 3.5.20 but we get an error message in the latest version. We made our own trend function and its related to this we get error message: Trend_Menu Device: PLC Logic: Application: C0032: Cannot convert type 'RTS_SYSTIMEDATE(systimertc, 3.5.20.0 (system))' to type 'RTS_SYSTIMEDATE(systimertc, 3.5.17.0 (system))' The variables are defined as follow: start : SysTimeRtc.SYSTIMEDATE; end : SysTimeRtc.SYSTIMEDATE; The code that creates the error is the variable start and end IF xAssign THEN xAssign := FALSE; xPanEnable := FALSE; xZoomEnable := FALSE; drs.liFrom := VisuTrendStorageAccess.TrendStorageConvertToTimestamp(start, 0 (us)); drs.liTo := VisuTrendStorageAccess.TrendStorageConvertToTimestamp(end, 0 (us)); drs.m_itfDateRangeSelectorClient.SetCurrentRange(drs.liFrom, drs.liTo); END_IF I cant understand really what the error message means and what can be the cause of the error? It compiles fine in dthe older codesys 3.5.19. If anyone has some experience of this please help us out? We must upgrade due to the new licenses. Thanks
Last updated: 2024-04-20
Post by sbrauns on Codemeter log error: API Error 200 (ENTRY NOT FOUND) occurred!
CODESYS Forge
talk
(Post)
Hi, I am using Codesyscontrol for linux 4.11 with an USB dongle with license. The log file from codemeter shows a constant error message which repeats every minute: Entry (6000437:8755) not found - Event WB0200 (ENTRY NOT FOUND), Request IP-Address local(IPV4) with UserLimit API Error 200 (ENTRY NOT FOUND) occurred! The log file from Codesyscontrol itself shows runtime licensed and I experience no other issues. But I am still concerned about the error message in the log file. Does anybody know what this is and how to fix it? thanks
Last updated: 2024-05-08
Post by xabier on BUG CODESYS-NO WORK AUTOMATICALLY RESTARSLAVES
CODESYS Forge
talk
(Post)
I detect a Bug of Codesys....NO WORK AUTOMATICALLY RESTARSLAVES. I explain the secuence: I have click in my project the option AUTOMATICALLY RESTARSLAVES In the moment start my Ipc, the network ethercat start correctly I disconnect the wire of my first slave and later connect again the wire..(see the screen Bug Codesys restart slave1) NO work the restart automatic slaves...and is not possible execute of FB MC_REset beacuause appear this error (see the screen Bug Codesys restart slave2) The only way for resolver this problem is execute the FB SMC3ReinitDrive I replay the same with PLC BECKHOFF in Twincat3 and I havent this problem...In the moment connect the wire again in the slave the comunication of ehterCat restart and the slave comunication again with out problem
Last updated: 2024-11-07
Post by felipemsgarcia on EtherCAT - Force Control Word
CODESYS Forge
talk
(Post)
What worked for me: Use SMC_SetControllerMode and set the nControllerMode to SMC_nocontrol. With that, you can control the drive via Modes of Operation(16#6060) and Controlword(16#6040) directly. Hope that helps, Cheers!
Last updated: 2023-08-31
Post by eschwellinger on Ethercat scan for devices not picking up EL7041 as a softmotion axis
CODESYS Forge
talk
(Post)
Add existing version (with SM drive) - without scan - disable under expert settings in the slave the revision check.
Last updated: 2023-09-03
Post by kumareasu on Code Size
CODESYS Forge
talk
(Post)
Hello, How to find the following for for my application when I want to switch over to "Application Based Licence"... Code Size. IO size When I use Analog IO. IO size when I use AC inverter(Drive for AC induction motor). For example we read/write few EtherCAT registers.
Last updated: 2023-09-07
Post by gurke258 on Codesys Safety EtherCAT with Beckhoff
CODESYS Forge
talk
(Post)
Okay, the solution was so simple... In my case, you first have to add the EL1918 and then the EL2904... then the connection is made automatically. I probably had something else before and then added the EL1918... then it doesn't catch the connection :/
Last updated: 2023-11-08
Post by justthefacts77 on How to generate an "ENI" file
CODESYS Forge
talk
(Post)
An ENI file is needed for a 3rd party software solution that is being used over EtherCAT connection that emulates multiple Slave devices. This one cant be that complex, seen some legacy posts but no answers. Thank you! Bruce
Last updated: 2024-08-08
Post by andreiot40 on Step motor ECT60 Ethercat in codesys 3.5
CODESYS Forge
talk
(Post)
Thanks for your response. for Master in log i have : no slaves found, Interface could not be opened, could not open network adapters. Status : Not running FOR ETC60 There is nothing !!!
Last updated: 2024-08-15
Post by atakan on Problem importing ethercat config file
CODESYS Forge
talk
(Post)
Hi draeby, I spoke with the manufacturer of the product. We found out that the XML file was faulty. They sent a new XML file and the problem was solved.
Last updated: 2024-08-21
Post by runtimevictor on codesys VLAN tagging
CODESYS Forge
talk
(Post)
Hello, the following store software may be required? https://store.codesys.com/en/codesys-ethercat-master-sl.html Please if anyone has this software installed can you tell me if it has VLAN tagging?
Last updated: 2024-09-09
Post by alex-at-xana on EThercat Dynamic configuration
CODESYS Forge
talk
(Post)
BTW - I had a chat with a Beckhoff support engineer. He explained that if you use sync0 and sync1, two frames per cycle are expected.
Last updated: 2024-09-19
Post by ton on Beckhoff EK series cannot detect but BK1120 detect
CODESYS Forge
talk
(Post)
Hi, I guess you don't have the right xml file. Download Beckhoff_EtherCAT_BKxxx_MDP.zip from https://download.beckhoff.com/download/configuration-files/io/ethercat/xml-device-description and install these in Device Repository.
Last updated: 2024-11-01
Post by felipemsgarcia on Axis EtherCAT address
CODESYS Forge
talk
(Post)
Hello, I'd like to write some parameters to axes from inside a function block where I passed axis by reference, using ETC_CO_SdoWrite. Is it possible to get the device address from inside the function block? Please see example below. Thank you!
Last updated: 2025-03-06
Post by dkugler on Statusabfrage EtherCAT Device
CODESYS Forge
talk
(Post)
das könnte noch eine Möglichkeit sein, siehe Codesys Hilfe: https://content.helpme-codesys.com/en/libs/IODrvEtherCATDriver/Current/IoDrvEtherCAT.html#chained-list-for-checking-of-all-slaves
Last updated: 2025-04-17
Post by r19h72 on Io-link library vor ethernet/ip
CODESYS Forge
talk
(Post)
gibt es Pläne für eine Erweiterung der io Link sl library auf ethernet/ip? derzeit sind nur profinet und ethercat verfügbar wann kann man damit rechnen?
Last updated: 2025-05-24
Post by alexanderraab on EtherCAT: How to change station-alias/ Slave address
CODESYS Forge
talk
(Post)
Hello, i have the same situation to change the Station-Alias adress online by IEC-Code. Have someone an exsample for that?
Last updated: 2025-08-13