Post by exkrim19 on Unable to connect to this device
CODESYS Forge
talk
(Post)
What worked for me with this error was to go to Tools -> Update Raspberry Pi, select Install, and from the popup screen, there are options to change your installation (I changed it to single core, instead of multicore), and I was then able to connect to my Rpi 4.
Last updated: 2024-06-28
Post by hermsen on Raspberry Pi 4.12.0.0 SL also stops after 15s
CODESYS Forge
talk
(Post)
After installing this new 4.12.0.0 SL version on my RPi5 8GB and the latest bootloader, the runtime disappeared after 15secs. The bootloader my pi uses is from 2024-06-11. I was able to resolve this issue using this post: https://forge.codesys.com/forge/talk/Runtime/thread/be25c0ff66/ The workaround works for me.
Last updated: 2024-07-06
Post by dkugler on Converting hex bytes to float
CODESYS Forge
talk
(Post)
have a look at UNIONs. With a union you are able to write single bytes to the same adress area which belongs to a float variable at the same time. I like to do a lot of convertions belonging to interfaces and fieldbus in this way, f.eg. word / byte swapping etc.
Last updated: 2024-08-06
Post by runtimevictor on codesys VLAN tagging
CODESYS Forge
talk
(Post)
Hello, In Codesys I can't find where to configure Ethercat Master VLAN tagging? In Beckhoff in Infosys there is an attached image so you can see it... I would like to try ethercat master with VLAN, to try to have several ethercat masters on a single ethernet port... I imagine that managed VLAN switches are also necessary? Thanks.
Last updated: 2024-09-06
Post by joep on Creating Custom Kinematics
CODESYS Forge
talk
(Post)
Hi John, Coincidentally I also tried creating a custom kinematics model for a parallel delta2 like the picture I added. bipod_rotary doesn't seem to do the job. Have you accomplished a working model? I'm stuck on error: "smc_cp_invalid_path_elem" while im certain my math is correct since we made it work using single axis movements. Maybe we could help each other Best regards, Joep
Last updated: 2024-09-06
Post by andrax on CodeSys Raspberry pi I2C driver not found
CODESYS Forge
talk
(Post)
Ok, this is a test programme with ADS1115. It is currently configured for the TCA9548 muxboard. If you want to run the ADS1115 single, then change the settings to the default values: ‘Is Multiplex:’ False ‘Stage mux channel numbers:’ [0,0,0,0,0,0,0,0,0] It is also important that the libraries are installed correctly here. But should be in this project
Last updated: 2024-11-07
Post by imdatatas on Problem with edge gateway config mode
CODESYS Forge
talk
(Post)
I encountered the same problem. (Windows10 x64 single language OS). As @eschwellinger mentioned, I uninstalled the latest EdgeGateway version and installed version 3.5.20.0. Now, when I right-click and select "Allow Edge Gateway...", Config mode is activated without any error or warning window and I do not need to manually type [CmpEdgeGateway] for EdgeGateway version 3.5.20.0.
Last updated: 2025-02-04
Post by rickwot809 on Codesys Soft PLC OPC UA server
CODESYS Forge
talk
(Post)
Enabling Anonymous Login 1. Navigate to 'Device' > 'Communication Settings' > 'Device'. 2. Next, click on 'Change Runtime Security Policy'. 3. In the new window, find and check the box for 'Allow anonymous login'. After completing these steps, you should be able to communicate with the OPC UA server.
Last updated: 2025-09-11
Post by dhumphries on IO link on IFM AL133x only single digital input on a channel
CODESYS Forge
talk
(Post)
Try changing the port mode to digital input for each port you want to have 2 inputs in the connection settings for the device. I've successfully used ports for inputs on an AL1920 this way, I think the procedure should be the same for an AL1332.
Last updated: 2023-12-30
Post by nima-khajehali on Data Transferring between 2 PLCs in a same PC
CODESYS Forge
talk
(Post)
Hi Guys, I want to simulate the data exchange between 2 soft PLCs on the same PC. We are trying to simulate the process and we could not see the desired result. What should I do to pass all data between these 2 PLC's correctly ? Please see attached
Last updated: 2024-02-05
Post by michelebianchi on cm4 runtime problem
CODESYS Forge
talk
(Post)
hello i have installed codesys runtime mc sl and sl on a CM4 but after 30 second process exit. have tried those runtime versions: 4.08 4.09 4.10 4.11 i get this message in all situations: ooops... this runtime was built for RASPBERRYPI. Hardware version or firmware version not supported! (-18, 0x00000BB8, 0xFFFFFFFB) os version is raspbian bullseye
Last updated: 2024-05-02
Post by gatto on warning C0195
CODESYS Forge
talk
(Post)
Good morning dear codesys users. I'm using 3.5.20.40 and I get this warning C0195 when I assign an initial value to xyz. However, if I do it on a single byte (abc), it doesn't display any warning. Why? VAR_GLOBAL abc : BYTE := 100 ; xyz : ARRAY [1..10] OF BYTE := [10(100)] ; END_VAR
Last updated: 2 days ago
Post by pmasip on Codesys Control for Raspberry Pi 4.10.0.0 - Raspberry Pi OS > 2023-12-05
CODESYS Forge
talk
(Post)
So none of the images from the 64bit archive work with any Codesys Control versions? I have tried the last Pi OS with every Codesys Control version and they don't work. I was wondering if there's any stable combination of versions.
Last updated: 2024-01-04
Post by culius on Codesys Control for Win & WagoApp Bibliotheken
CODESYS Forge
talk
(Post)
Hey, ist es nicht möglich die WagoApp Biblitoheken in zusammenhang mit dem Codesys Control for Win zu nutzen? Wenn ich so eine Bibliothek im Projekt habe, lässt sich das Programm nicht auf das Device Control for Win nicht laden. Entferne ich die Bibliotheke geht es ohne Probleme. Hat damit schon jemand Erfahrung gemacht? Viele Grüße!
Last updated: 2024-01-31
Post by superjojo2002 on Licensing info not available.
CODESYS Forge
talk
(Post)
I recognized that I have to start the two services "/etc/init.d/codemeter" and "/etc/init.d/codemeter-webadmin" in the docker container as well. If I do so, then the command "cmu -x" returns root@sensoredge-field-netfield-produktmanagment:/# cmu -x cmu - CodeMeter Universal Support Tool. Version 7.60c of 2023-Aug-09 (Build 5625) for Linux/ARMHF 64-Bit Copyright (C) 2007-2023 by WIBU-SYSTEMS AG. All rights reserved. So this time there is no indication any more that "Codemeter is not running". But still we are getting the error when using the license manager in CODESYS development system.
Last updated: 2024-03-21
Post by fontrap on cmDongle Raspberry Pi issue
CODESYS Forge
talk
(Post)
Good morning @eschwellinger, After some research I found out that the problem is the preinstalled CodeMeter on Raspberry Pi. As I mentioned the CodeMeter was installed on the Raspberry because I use a license from other vendor that needs the CodeMeter to be installed. The problem is that when I uninstall the CodeMeter from Raspberry I am able to detect the dongle from CODESYS and everything works as it should be but now the other product can not detect its own license. When I reinstall the CodeMeter I am back to the initial problem. Is there a way to overcome this conflict through CODESYS?
Last updated: 2024-04-24
Post by reinier-geers on License problem gateway
CODESYS Forge
talk
(Post)
16.4 Epis What has it to do with the manufacture? It just a licence more not. So basicly the idee of codesys sucks. 3s acts like its posible to add a license. And then it depence on the manufacturer. Why ?? Its a computer !! has nothing to do with the manufacturer. Most dont what a basic licence because they have to pay for that. 3s is the problem not the manufacture of the hardware. Its like the licence of the raspberry pi. HMI is not working. Sorry you get a refund. Why suggest that its possible wen its not !!. It cost me a lot of time. Who pays my time. Why do i have to pay for somting thats not working.
Last updated: 2024-04-26
Post by arundara on Variable Sync Issue In Soft Plc Redundancy
CODESYS Forge
talk
(Post)
Hello, I was trying to create a redundancy POC for our application where we read data from few modbus tcp devices. As there is a limitaion that modbus tcp device support only for single master device, we wanted to test how the variable sync happens in redundancy mode. For that i have used the redundancy sample code added a variable "b" under a condition. What i observed was while active controller is running, if passive controller is powerup, passive controller is able to sync all the data configured for redundacny. But after that the variable data which resided under a condition is not synching from active to passive controller. I have attached the image where i have highlighter the variable. Can some help me to understand how redundacny work in codesys soft plc and if there is a solution to sync variable which are under condition, please explain the same or suggestion to achieve the same. Hardware - Raspberry Pi (2 qty) Redundancy licence used - yes in both controllers. Codesys runtime - 4.9.0.0 Codesys software version - V3.5 SP19 if i have posted this question in wrong section, please do let me know in whcih section i have to post this question.
Last updated: 2023-12-01
Post by timvh on Unable to Connect to Modbus RTU Device
CODESYS Forge
talk
(Post)
If your Control Win is the Modbus "Master" then your configuration should be something like: Modbus_COM (Serial port) - Modbus Master (this is the Control Win SoftPLC actively setting up the communication) - Modbus Slave (this is then your WAGO 750-315) You need to add channels to the Modbus Slave configuration to inform the master which variables to read/write from the Wago module. The way you configured it now, the Control Win is also a slave. PS, don't forget to put the PLC (Control Win) in Run.
Last updated: 2024-09-03
Post by eschwellinger on OPC UA Server Status on Win RTE
CODESYS Forge
talk
(Post)
latest version of the Control RTE?
Last updated: 2024-10-21
Post by eschwellinger on Control for Raspberry Pi 4.17
CODESYS Forge
talk
(Post)
today or tomorrow ;-)
Last updated: 2025-08-26
Post by morecoffee on Control for Raspberry Pi 4.17
CODESYS Forge
talk
(Post)
the runtime update to 4.17.0.0 fixed my issue, thank you.
Last updated: 2025-09-08
Post by eschwellinger on Codesys Control for Win & WagoApp Bibliotheken
CODESYS Forge
talk
(Post)
bitte den Wago Support fragen..
Last updated: 2024-01-31
Post by kalmeyer on Stepper motor control with (SM_Drive_RaspStepper_direct)
CODESYS Forge
talk
(Post)
HERE IS MY PLC_PRG /KLAUS
Last updated: 2025-11-04
Post by eschwellinger on Stepper motor control with (SM_Drive_RaspStepper_direct)
CODESYS Forge
talk
(Post)
Which SoftMotion version is installed?