Post by gunstr on CODESYS control on RPi starts, shortly runs, then exits
CODESYS Forge
talk
(Post)
Thank you very much for the quick answer! The RPi hw were delivered last week so it's probably a resent version. I found an old scrapped board (2 years or so) with a broken GPIO that I tested with the same SD card image and with that board Codeys can run for the full 2h demo period without issues. Then I went back the the new board to test the 4.17.0.0 release but the installation fails... [INFORMATION] Standard output: create and install daemon [INFORMATION] Standard output: codesyscontrol started [WARNING] Unable to detect Raspberry Pi Architecture. Setting armv6l as default, you can change this through the settings panel. [INFORMATION] Standard output: codesyscontrol stopped [ERROR] Expected exit value of command failed: expected 0, received 1 [WARNING] Error setting the Raspberry Pi Architecture [ERROR] Error installing codesyscontrol Do you have any idea what could be the reason? I'm using an OS image including Python drivers for LCD and some I/O:s from last year to keep things stable, but also after upgrading with sudo apt update && sudo apt upgrade I still get the same error Reverting back to 4.15.00 works fine: [INFORMATION] Standard output: create and install daemon [INFORMATION] Standard output: codesysedge started [INFORMATION] Successfully installed codesyscontrol [INFORMATION] Successfully started CODESYS Edge Gateway for Linux [INFORMATION] Successfully started CODESYS Control for Raspberry Pi SL but as before the Codesys services stops after 30 seconds. And I noticed that the Codesys control stops and is not reachable also if I have no application loaded.
Last updated: 2025-09-02
Post by gunstr on CODESYS control on RPi starts, shortly runs, then exits
CODESYS Forge
talk
(Post)
I now tried to install 4.17.0.0 on a fully clean installations: A brand new RPi 4B Install latest Raspberry Pi OS Lite, Release date 13 May 2025, 64bit run sudo apt update && sudo apt full-upgrade When asked - Select to install the updated version of '/etc/initramfs-tools/initramfs.conf' Install CODESYS Control for Raspberry Pi SL. version 4.17.0.0 Log output: [INFORMATION] Connected successfully! [INFORMATION] Successfully connected to target (192.168.0.197) [WARNING] No supported container engine found on device. You have to install a supported container engine to use Virtual Control. Please contact the Administrator of the device. [WARNING] Error detecting container architecture [INFORMATION] Finished reading device information [ERROR] Error output: /var/lib/dpkg/info/codesyscontrol.postinst: 88: check_legacy_extensionapi_folder: not found [INFORMATION] Standard output: Selecting previously unselected package codesyscontrol. [INFORMATION] Standard output: (Reading database ... 76772 files and directories currently installed.) [INFORMATION] Standard output: Preparing to unpack .../codesyscontrol_raspberry_4.17.0.0_all.deb ... [INFORMATION] Standard output: Unpacking codesyscontrol (4.17.0.0) ... [INFORMATION] Standard output: Setting up codesyscontrol (4.17.0.0) ... [INFORMATION] Standard output: make config rw [INFORMATION] Standard output: set folder permissions [INFORMATION] Standard output: prepare permissions [INFORMATION] Standard output: check legacy extension api folder [INFORMATION] Standard output: create and install daemon [INFORMATION] Standard output: codesyscontrol started [WARNING] Unable to detect Raspberry Pi Architecture. Setting armv6l as default, you can change this through the settings panel. [INFORMATION] Standard output: codesyscontrol stopped [ERROR] Expected exit value of command failed: expected 0, received 1 [WARNING] Error setting the Raspberry Pi Architecture [ERROR] Error installing codesyscontrol If I read the log correctly the control is actually installed but cannot start. I'm running out of ideas how to proceeed now, any suggestions are welcome.
Last updated: 2025-09-03
Post by testlogic on Sending Sequential Modbus TCP Packets
CODESYS Forge
talk
(Post)
I have a Modbus TCP slave device where I need to do sequential writes to the same register. The register I'm writing to is kind of like a command line, each packet is a command word encoded in Hexadecimal. I am having difficulty implementing this system in CoDeSys 3.5 SP19. I feel like the structure of the program should be something along the lines of (Pseudocode): ModbusTCPSend(Command Register, Command1) ModbusTCPSend(Command Register, Command2) ModbusTCPSend(Command Register, Command3) I have tried to implement this with a rising edge trigger wMot1OPCode := 16#E1; //Stop Motor & Kill Program xMot1SendOP := TRUE; //Send OP on rising edge xMot1SendOP := FALSE; //Reset wMot1OPCode := 16#9E; //Disable Motor xMot1SendOP :=TRUE; //Send OP on rising edge xMot1SendOP := FALSE; //Reset Where "wMot1OPCode" is the IO map for writing to the command register, and "xMot1SendOP" is the rising edge trigger for that modbus channel. However, this doesn't work. The device never responds to the modbus commands. It seems like the trigger variable is switched too quickly for modbus to send the packet. I know the modbus register is working, because I can set the channel to cyclic and the device will respond. However, I can't use this reliably because I need each command to be sent once, in order. Cyclic keeps re-sending the commands and seems like it could miss a command as well if one was sent in-between cycle time. I have also trying using the Application trigger as described by https://faq.codesys.com/pages/viewpage.action?pageId=24510480, but this is also not working for me. See attached picture for my FBD code. This seems like a simple function, I can't tell what I'm doing wrong here. Thanks for the help.
Last updated: 2024-03-06
Post by mp9876 on Device logon problem following fresh install
CODESYS Forge
talk
(Post)
All screenshots are enclosed in MS Word document. NOTE; 4 questions features at the end. Any assistance would be greatly appreciated! Hi everyone, I am still having device logon problem following a fresh install Here are the STEPS I went through following a FRESH CODESYS Win 64 3.5.19.60 install on a different computer. ‘Gateway not configured properly’ when attempting to REFRESH from the Users and Groups. Then did Gateway manage and confirmed it was ok: This message popped out as it was a fresh install: YES then: Initially went with Administrator twice (user & password) but it did not like it. No device is responding to …: Continued by setting a new user Pressed OK and obtained the following message: Stopped and Restarted PLC at that point: Obtained the following: Attempted to login a 2nd time without success. Then I scanned the network to see if matching device can be detected: Only way to get it detected was to remove the tick in the ‘Hide non-matching devices…’ Attempted a WINK but got a return like this one: REFRESH either @ Users and Groups or @ Access Rights returns: Then created user ‘mp’ at Project level ang logged in: Understandably device user mp9876 was not valid for the Project. Device information A few questions comes to my mind following these connection attempts: 1- Gateway not configured properly message pops out because of a non-compatible device ? 2- Why would the device not be compatible ? 3- Any way to make the device compatible ? 4- Any ideas on how to get this connectivity problem to the device solved ?
Last updated: 2024-03-17
Post by manuknecht on Maximum dynamic limits of MC_MoveLinearAbsolute and MC_MoveLinearRelative
CODESYS Forge
talk
(Post)
Hello all I use an axis group with two linear axes in a kinematic system. Using MC_MoveLinearAbsolute and MC_MoveLinearRelative, I am trying to realise dynamic movements (set velocity: 1 m/s, set acceleration: 30 m/s^2) with the highest possible jerk, as I want to compare this with a movement with a trapezoidal velocity profile. However, my measurements show that the axes accelerate with a maximum jerk of approx. 800 m/s^3, even if the value in the function block was set to 10,000 m/s^3. I have already increased the dynamic limits of the two axes accordingly (Velocity: 5000 u/s, Acc-/Deceleration: 250'000 u/s^2, Jerk: 100'000'000 u/s^3, where 1 u = 1 mm), but this had no effect. I have checked the input parameters of the function blocks and the VelFactor, AccFactor and JerkFactor factors are all set to the maximum (value 1). Reducing the cycle time has resulted in a higher jerk, but as we are already working with a cycle time of 1 ms, there is nothing more that can be done here. The axes themselves are still a long way from drawing the maximum current, which is why I assume that this should not be a problem either. Are there other factors or parameters that influence the dynamic limits and therefore allow faster movements? The PLC I am using is a Raspberry Pi 4 and Codesys V3.5 SP20 with all libraries up to date. Thanks in advance Manuel
Last updated: 2024-05-08
Post by xcqt on Oop best practice
CODESYS Forge
talk
(Post)
Hi all, I’m currently trying to improve my OOP structure in CODESYS and I’m looking for some input on how others approach this. I understand the basics like inheritance, interfaces, abstract FBs, methods, and properties, but I still struggle a bit with the overall architecture and what’s considered clean or scalable in bigger projects. As an example, I’m working on two different energy meter function blocks: FB_EnergyMeter_MQTT reads data from MQTT (strings) FB_EnergyMeter_Modbus reads data from Modbus (words) Both have their own Update() method and implement the same interface (something like IF_EnergyMeter). Later on, I’ll probably add more meter types, but they should all behave the same from the controller’s point of view. Now, there’s a FB_GridControl block that needs power data from these meters. I see two options here: Define the meter blocks inside FB_GridControl and call them directly (for example fbModbusMeter.UpdateModbus()). Keep the meter blocks outside and pass them into FB_GridControl as interface references, so the control block doesn’t know which specific type of meter it’s dealing with. Option 2 feels cleaner and more flexible to me, but I’m not entirely sure how to handle the data flow in that case. Should I pass the meter instance through an interface reference (REFERENCE TO IF_EnergyMeter)? Or is there a better way to link the external FBs to the control block? I’d like to hear how you structure this kind of setup or see an example from someone who has done something similar. EDIT: I think i need to do something like this fbModbusUpdateInput(wInput:= wWordValue); fbMqttUpdateInput(strInput:= strStringValue); IF bUseMqtt THEN Meter REF = fbMqttUpdateInput; ELSE Meter REF = fbModbusUpdateInput; END_IF fbControl.SetMeter(UsedMeter := Meter); Or am i thinking wrong? Thanks, Thomas
Last updated: 2025-10-16
Post by kishan on SMC_Interpolator / CNC Abort – ControlAxisByPos Sometimes Remains Busy and Axis Continues Moving
CODESYS Forge
talk
(Post)
Hello, I am working with CODESYS SoftMotion CNC using a preprocessing chain, SMC_Interpolator, and SMC_ControlAxisByPos for controlling the CNC axes. I have noticed an issue when aborting CNC execution. When I execute the Abort command, I abort both the CNC preprocessing blocks and SMC_Interpolator. Normally the CNC process stops correctly. However, occasionally after the abort: SMC_Interpolator has already been aborted. CNC preprocessing has also been aborted/reset. But SMC_ControlAxisByPos.bBusy remains TRUE. The corresponding physical axis can still continue moving for some distance. This does not happen every time. My basic sequence is similar to: G-code / CNC preprocessing ↓ SMC_Interpolator ↓ Transformation ↓ SMC_ControlAxisByPos ↓ SoftMotion Axis When the operator requests CNC Abort, I set the Abort inputs of the interpolator and preprocessing function blocks. My questions are: Does SMC_Interpolator.bAbort only stop/reset the interpolator, or should it also stop the motion currently being executed by SMC_ControlAxisByPos? Can SMC_ControlAxisByPos remain Busy after the interpolator has been aborted? If bAvoidGaps = TRUE, could SMC_ControlAxisByPos still be trying to reach the last fSetPosition using the fGapVelocity / fGapAcceleration / fGapDeceleration settings after the interpolator has stopped? What is the recommended sequence for safely aborting a running CNC program? For example, should the sequence be something like: Stop / Abort Interpolator Disable SMC_ControlAxisByPos Execute MC_Stop for all physical axes Wait until all axes reach standstill Abort/reset preprocessing blocks and CNC queues Reset CNC state Re-enable axis controllers Or is there a recommended CODESYS CNC method for performing a complete CNC Abort? I would especially like to understand why SMC_ControlAxisByPos.bBusy can occasionally remain TRUE and continue moving the axis even though the interpolator and preprocessing blocks have already been aborted. CODESYS SoftMotion CNC is being used with real EtherCAT servo axes. Any explanation about the correct abort/stop sequence would be appreciated.
Last updated: 2026-09-25
Post by ihatemaryfisher on Sorting array of any-sized structure
CODESYS Forge
talk
(Post)
In my machine's operation, I need to display multiples tables containing arrays of structured variables. The arrays change during operation, and my supervisor has advised me to write a new bubble-sort for each array. I think I can make a function to sort an array of any data type. This was my own project, and I'm a relatively new coder. I want to know the weaknesses in my approach, and a better method, if one exists. As far as I can test, the function accepts an array of a structured variable of any size, and sort it by any VAR in that structure. But it relies heavily on pointers, which I've heard are bad practice? Function call: // SORT BY BYTE-SIZED VAR IF xDoIt[6] THEN FUNBubbleSortSansBuffer( IN_pbySourcePointer := ADR(astArray[1]), // address of first byte in first element of array IN_pbyComparePointer:= ADR(astArray[1].byCompByte), // points to first byte of the comparing variable (variable you sort by) IN_uiStructureSize := SIZEOF(TYPE_STRUCTURE), // size, in bytes, of the structured variable IN_uiCompareSize := SIZEOF(astArray[1].byCompByte), // size, in bytes, of the comparing variable (variable you sort by) diArrayElements := UPPER_BOUND(astArray,1), // number of elements in array IN_xSmallToLarge := xSortOrder // whether to sort by small2large or large2small ); END_IF Function: FUNCTION FUNBubbleSortSansBuffer : BOOL VAR_INPUT IN_pbySourcePointer : POINTER TO BYTE; // points to beginning of array (first byte of first element) IN_pbyComparePointer: POINTER TO BYTE; // points to first byte of the comparing variable (variable you sort by) IN_uiStructureSize : UINT; // size, in bytes, of the structured variable IN_uiCompareSize : UINT; // size, in bytes, of the comparing variable (variable you sort by) diArrayElements : DINT; // number of elements in array IN_xSmallToLarge : BOOL; // whether to sort by small2large or large2small END_VAR VAR j : DINT; // repeat iteration over array until array ends i : DINT; // iterarte over array, swapping when necesary k : DINT; // iterator from 1 to size of structure (stepping 'through' a single element in array) dwSize : DWORD; // internal var for use in MEMUtils.MemCpy(<size>) // FOR SORTING BY BYTE VAR pbySourcePointer : POINTER TO BYTE; pbySourcePointer2 : POINTER TO BYTE; pbyComparePointer : POINTER TO BYTE; pbyComparePointer2 : POINTER TO BYTE; pbyPointerToBuffer : POINTER TO BYTE; // pointer to single byte buffer byBufferByte : BYTE; // single byte buffer END_VAR dwSize := UINT_TO_DWORD(IN_uiStructureSize); // get structure size (number of bytes) pbyPointerToBuffer := ADR(byBufferByte); // assign pointer to address of buffer byte (because MEMUtils.MemCpy requires a pointer input) CASE IN_uiCompareSize OF // depending on the size of the VAR to sort by (current functionality for BYTE and WORD/INT 1: // BYTE (8 BIT) FOR j := 1 TO diArrayElements DO // for number of elements in array FOR i := 1 TO (diArrayElements-1) DO // same thing, but row[i+1] row is included in swap logic pbySourcePointer := IN_pbySourcePointer + dwSize*(i-1); // point at #1 byte in array element[i] pbySourcePointer2 := pbySourcePointer + dwSize; // point at #1 byte in array element[i+1] // NOTE: because of memory locations, each array element is offset from one another by a number of bytes equal to the size of the structure // We can "walk" from array[i] to array[i+1] via steps equal to the size of the structure // e.g., ADR(array[i+1]) == ADR(array[i]) + SIZEOF([array datatype]) pbyComparePointer := IN_pbyComparePointer + dwSize*(i-1); // point to sorting variable in array element[i] pbyComparePointer2 := pbyComparePointer + dwSize; // point to sorting variable in array element[i+1] // using sort order (small -> large/large -> small) IF SEL(IN_xSmallToLarge, (pbyComparePointer2^ > pbyComparePointer^),(pbyComparePointer2^ < pbyComparePointer^)) THEN // This is where it gets tricky. We've identified pointers for the starting bytes of aArray[i] and aArray[i+1] // and we know the size of aArray[i]. We are going to swap individual bytes, one at a time, from aArray[i] and aArray[i+1] // this allows us to use only a single byte var as a buffer or temporary data storage // e.g., consider a structure consisting of a word, a byte, and a string. it is stored like this // |------WORD-------| |--BYTE-| |STRING------...| // astArray[1] == 1000 0100 0010 0001 1100 0011 1010 1010.... etc // astArray[2] == 0001 0010 0100 1000 0011 1100 0101 0101.... etc // performing a single swap (copy into a buffer, etc.) of the first byte of each array element creates this // astArray[1] == 0001 0100 0010 0001 1100 0011 1010 1010.... etc // astArray[2] == 1000 0010 0100 1000 0011 1100 0101 0101.... etc // incrementing the pointer adresses for the swap by 1 and swapping again swaps the next byte in each array element // astArray[1] == 0001 0010 0010 0001 1100 0011 1010 1010.... etc // astArray[2] == 1000 0100 0100 1000 0011 1100 0101 0101.... etc // continuing this from k to SIZEOF(TYPE_STRUCTURE) results in a toally swapped row FOR k := 1 TO IN_uiStructureSize DO // copy single byte[k] of array element 1 to buffer MEMUtils.MemCpy(pbyDest := (pbyPointerToBuffer), pbySrc := (pbySourcePointer+k-1), dwSize := 1); // copy single byte[k] of array element 2 to 1 MEMUtils.MemCpy(pbyDest := pbySourcePointer+k-1, pbySrc := (pbySourcePointer2+k-1), dwSize := 1); // copy buffer to byte[k] array element 2 MEMUtils.MemCpy(pbyDest := (pbySourcePointer2+k-1), pbySrc := pbyPointerToBuffer, dwSize := 1); END_FOR END_IF END_FOR END_FOR
Last updated: 2023-08-17
Post by baltzer on ICertificateVerifier.VerifyCertificate doesn't appear to override an ERR_CERT_HAS_EXPIRED rejection in TCP_Client.Upgrade()
CODESYS Forge
talk
(Post)
Setup: Net Base Services (NBS), TCP_Client + TLSContext, ePurpose := CLIENT_SIDE, connecting to a third-party embedded device (Velux KLF200 home automation gateway) whose factory-installed TLS certificate expired on 2026-07-12 and has no user-facing renewal path. Tested on both CODESYS Control for Raspberry Pi SL (3.5.19.0) and CODESYS Control Win V3 x64, with identical results on both. Goal: Accept the peer's expired certificate via a custom ICertificateVerifier implementation, since the certificate itself can never be replaced. Implementation: FUNCTION_BLOCK FB_MyCertVerifier IMPLEMENTS NBS.ICertificateVerifier VAR udiCallCount : UDINT; aeCurStateLog : ARRAY[0..9] OF NBS.RTS_IEC_RESULT; END_VAR METHOD VerifyCertificate : UDINT VAR_INPUT hCert : NBS.RTS_IEC_HANDLE; eCurState : NBS.RTS_IEC_RESULT; END_VAR IF udiCallCount < 10 THEN aeCurStateLog[udiCallCount] := eCurState; END_IF udiCallCount := udiCallCount + 1; VerifyCertificate := 0; // also tried: VerifyCertificate := eCurState; Wired in via tlsContext.itfCertVerifer := certVerifier at declaration time, alongside itfTLSContext := tlsContext set at TCP_Client's own declaration (per an earlier forum thread here on ensuring inline start-values on FB-typed variables are actually honored when nested one level deep - that fix was needed and worked correctly for getting the handshake to start at all). Observed: - VerifyCertificate is confirmed called exactly once per connection attempt (via the call counter above). - eCurState passed in = 0x709 = ERR_CERT_HAS_EXPIRED - correctly reflecting the actual state of the peer's certificate. - Packet capture confirms the full TLS 1.2 handshake completes correctly at the wire level: ClientHello -> ServerHello -> Certificate -> ServerKeyExchange -> ServerHelloDone -> our ClientKeyExchange/ChangeCipherSpec/Finished -> server's ChangeCipherSpec/Finished. Both sides successfully complete the cryptographic handshake. - Despite this, TCP_Client.Upgrade() subsequently returns NBS.ERROR.CONNECTION_ERROR, and the connection is torn down with a plain TCP FIN (not a TLS alert) roughly 7-8ms after our side ACKs the server's Finished message. - TCP_Client.eErrorID (inherited from LCon) remains NO_ERROR throughout - the failure is only visible via Upgrade()'s return value. - Returning 0 (ERR_OK/ERR_CERT_OK - confirmed via the CmpErrors2 Interfaces documentation that these are literally the same value) makes no difference. - Echoing eCurState back unchanged (on the theory that this callback might work like mbedTLS's native verify callback, where the incoming state is a flags value to be cleared/modified and returned, rather than paired with a separate fixed "accept" sentinel) also makes no difference. - Identical result across udiVerificationMode := 0, 1, and 2. - Importing the peer's certificate into the runtime's trusted certificate store via cert-import trusted makes no difference either. - With itfCertVerifer left at its default (no custom verifier) and udiVerificationMode := 2, the underlying engine sends its own fatal TLS alert (handshake_failure) immediately after receiving the peer's Certificate message - suggesting built-in validation may reject at the record layer independent of whether a custom verifier is even present. Questions: 1. Is there an additional step required for a custom ICertificateVerifier to actually override an ERR_CERT_HAS_EXPIRED (or more generally, any ERR_CERT_*) rejection, or is certificate validation enforced unconditionally for a CLIENT_SIDE TLSContext regardless of what the verifier returns? 2. Is 0/ERR_OK genuinely the correct "accept" return value for VerifyCertificate, or does it expect something else (a specific bit pattern, a different constant, a value that must be computed from hCert itself)? 3. Is there a supported way to connect to a peer presenting a certificate that is both self-signed and expired, short of the peer issuing a new certificate? Happy to share the full packet captures or additional test combinations if useful. Also worth noting for anyone finding this thread later: a maintained Node-RED library for this same device (node-red-contrib-velux-klf200, forked to handle this exact expired-certificate situation) solves it by disabling built-in TLS validation entirely (rejectUnauthorized: false) and doing fingerprint-based pinning by hand after the handshake completes, rather than relying on a validation callback - which may be the more realistic approach here too if ICertificateVerifier genuinely can't override this class of rejection. Thanks in advance /Jørgen Disclosure: most of the CODESYS code and this investigation was developed with the help of Claude (Anthropic's AI assistant) - the state machine design, SLIP/checksum implementation, and debugging methodology (including the packet capture analysis) were worked through in an extended back-and-forth with it. Posting here because we've run out of self-serviceable options and this now looks like it needs input from someone with visibility into NBS's actual implementation.
Last updated: 2026-07-26
Post by thn-power on Updating OPC UA Core Nodeset on PLS
CODESYS Forge
talk
(Post)
Hi After much trail and error I think I found the root cause to my OPC UA problem. The problem is that I cannot manage to build and download a program with a a custom OPC UA Information model. We use a Weidmueller WL2000 PLS, but the problem also exsist on the Win V3 PLC. Our custom information model is based on the latest versions of the OPC UA Core Nodeset v 1.05.03 (2023-09-20) and UA/DI nodeset 1.04.0 (2022-11-03) Those nodesets are installed in the Codesys Information Model Repository (3.5.19.6) However, when trying to build I get the following error. [ERROR] Untitled1: Communication Manager [Device: PLC Logic: Application]: The information model http://opcfoundation.org/UA/ is required by http://bos.org/ with a minimal publication date from 15.12.2023 but the device has only a model from 15.09.2021 installed. Probably the information model from 15.09.2021 is missing in the information model repository. [ERROR] Untitled1: Communication Manager [Device: PLC Logic: Application]: The information model http://opcfoundation.org/UA/DI/ is required by http://bos.org/ with a minimal publication date from 03.11.2022 but the device has only a model from 09.03.2021 installed. Probably the information model from 09.03.2021 is missing in the information model repository. Build complete -- 2 errors, 1 warnings : No download possible I think the problem is that the UA Core nodeset is implemented in the PLC firmware (at least that in Siemens S7), and that only includes the "old" nodeset from 2021-09-21 etc. So the question is, how (or if?) can I transfer the new nodeset to the PLS? I have created separate Information models under Communication manager with the newer code nodesets (UA and DI). But it seems that the compiler does not recognize them being excising, neither in the Codesys IDE or on the PLC. Would have guessed that this is a common issue, sine many manufacturers use the latest versions of the OPC UA standard, and that it would be a solution to the problem.
Last updated: 2024-09-20
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.