Post by installwhat on How to access to variable value through symbolic string name CODESYS Forge talk (Post)
https://help.codesys.com/api-content/2/codesys/3.5.12.0/en/_cds_operator_string_to/ Something like this?
Last updated: 2024-06-13

Post by davidbo on How to stop dhcpcd and use SysSockSetIpAddressAndNetMask to set address? CODESYS Forge talk (Post)
The reason for why CODESYS halts was a CODESYS watchdog exception. 'sudo ip' takes a long time.
Last updated: 2025-11-04

Post by eschwellinger on Reset device password Festo PLC CODESYS Forge talk (Post)
these credentials are saved in the plc - you need to ask Festo how to do this.
Last updated: 2026-08-13

Post by durallymax on Help understanding analog in-/outputs CODESYS Forge talk (Post)
WAGO will use 0-32767 as the raw units. Note a value of 3 means over/under range. Map that IO however you please, then scale in your program using any of the available libraries or with your own simple y=mx+b scaling formula to get to the engineering units you desire. Inverse for the AO to get back to 0-32767.
Last updated: 2024-12-15

Post by calviniscoding on Publish a JSON payload via MQTT Publish (using IIot Libraries) CODESYS Forge talk (Post)
Are you able to dynamically change the JSON message? As in, if wsValue or iValue is linked to some real telemetry that varies over time, will the JSON message reflect these changes? I am only able to send the values that I initialize the JSON message to
Last updated: 2024-06-18

Post by winki on Not Possible to connect using control SL CODESYS Forge talk (Post)
Hello, I used to connect into my gateway using control SL tool 4.13, (it was called Update Linux.) I formated my computer, so today I install the new version of codesys and all package. Now I am not able to connect to my PLC using control SL. It says, check the status. Normally it used to worked perfectly before that.
Last updated: 2025-01-07

Post by jbcregen on Accessing parameters from a structure or function block with the web interface CODESYS Forge talk (Post)
I have a project with hundreds of OPC-UA variables available on the network. A lot of these variables are used actively in various scripts that run in background in the OS (Linux). I'm experimenting with Automation Server and I have a hard time understanding how the web interface populates its parameters list for a given PLC (<plc details="" parameters="" for="" plc="" 'xyz'="">).</plc> In this page, it looks like the only variables available are the ones that are of a "base" type : bool, TIME, String, INT, etc. All the variables that are nested into function blocks or structures are not available in the web interface, even if they are available to any OPC-UA client. Is this a limitation of the Automation Server or is there something that can be done in Codesys?
Last updated: 2025-12-01

Post by jonasz on Deploy LicenseServer for Linux SL CODESYS Forge talk (Post)
So here's how: I manually installed the following packages: codemeter-lite_8.30.6885.501_amd64.deb codesyslicenseserver_licenseserver_4.18.0.0_all.deb codesyswbmbase_wbmbase_4.18.0.0_all.deb codesyswbmlicensing_wbmlicensing_4.18.0.0_all.deb Of course, the license server appeared immediately. Trying to install it again using Install in the Deploy tab, the same error appears. Of course, the information that such a server is already installed is also there. Configuring PLC, S_PLC, EDGE, and SAFE_TIMER_PROVIDER went smoothly, and basically everything works. I wrote a simple program for S_PLC. I'm loading the programs into PLC and S_PLC. When loading the program into S_PLC, a message appears stating that there is no connection to the S_PLC controller. Timeout error. Restart the controller, attempt to load, and see the above. After changing the cycle time for S_PLC to 50ms, the problem no longer occurs. My question, besides the difficulty of installation for a new user, is what causes the cycle time for S_PLC to be so long, and how can I fix it?
Last updated: 2025-11-14

Post by westcountryewe on Displaying a Target Web Page on WebVisu CODESYS Forge talk (Post)
I have a main PLC with my CODESYS project on, including Web Visu. I also have a second device used for pump monitoring, all of this is displayed on a seperate HMI. I am looking at displaying the pump monitoring HMI on WebVisu so that I can solely use 1 HMI rather than having two. I can project the pump monitoring HMI into Chrome, and log in and it works fine. When I'm using the Web Browser element in Web Visu, enter my URL (device IP) it shows me the web page, but doesn't show me all of it. It uses parts of JavaScript for the login authenticiation and various other widgets. Similarly, I cannot get Youtube or Google to display on WebVisu either (possibily because of the same reason). Does anybody have any tips on how I can display the likes of Youtube or Google onto WebVisu so I can view it on my 7inch HMI (I suspect that if I can get Youtube or Google to work, then I will also be able to get my pump montitoring web page to work too).
Last updated: 2025-07-09

Post by leafy on Use third party actuator with IO-Link Master (IFM) CODESYS Forge talk (Post)
Hey there! I am currently doing a little automation project for uni. I am trying to integrate a control-valve-system (Buerkert AirLINE Field) in my IO-Link environment. With IFM sensors, I used their pre-built function blocks, but with this third-party device, i need to write my own function block. Thankfully, IFM provides a generic sensor-fb so I can write my own FB with "extends" and "super". So far, so good. I found the IODD and some other documentation and I thought I get how it works, but somehow can't really get it to work at all. From my understanding, i need to write data into the PDO-Array. But i get confused with the indices and subindices of IO-Link. I'll append the IODD and some screenshots of my project. There is an AOI for LogicXDesigner, but I can't use that in Codesys. I hope someone has integrated a IOL-device in Codesys before and can help me with this. Cheers leafy
Last updated: 2024-04-16

Post by leafy on Use third party actuator with IO-Link Master (IFM) CODESYS Forge talk (Post)
Hey there! I am currently doing a little automation project for uni. I am trying to integrate a control-valve-system (Buerkert AirLINE Field) in my IO-Link environment. With IFM sensors, I used their pre-built function blocks, but with this third-party device, i need to write my own function block. Thankfully, IFM provides a generic sensor-fb so I can write my own FB with "extends" and "super". So far, so good. I found the IODD and some other documentation and I thought I get how it works, but somehow can't really get it to work at all. From my understanding, i need to write data into the PDO-Array. But i get confused with the indices and subindices of IO-Link. I'll append the IODD and some screenshots of my project. There is an AOI for LogicXDesigner, but I can't use that in Codesys. I hope someone has integrated a IOL-device in Codesys before and can help me with this. Cheers leafy
Last updated: 2024-04-16

Post by simotion on Codesys Softmotion Win V3 x64 CODESYS Forge talk (Post)
I have a project in Codesys v3.5 sp19 patch2 that contains softmotion virtual axes. I want to simulation the code (softmotion) on the simulated plc on the pc. The controller in the project is a Codesys Softmotion Win V3 x64. I have started up the Codesys Softmotion Win 64 on the pc. However it seems a 3.5 sp14 controller. When trying to download the project, I get a message that target system is different from connected system (3.5.19 vs 3.5.14). How do I set the connected system to 3.5.20 (there seems no way to set the target system to 3.5.14
Last updated: 2023-10-04

Post by jari-koivuluoma on Comparing between SP19 patch 5 and patch 7 CODESYS Forge talk (Post)
Hello. Has anyone here used project compare tool across different versions of Codesys? I tried the compare of the title but it does not seem to do much. It lets me choose the project files and then seems to be comparing but no results are ever shown. If the compare tool cannot be used how else would I keep 2 nearly identical projects in sync when the versions differ? On the other hand it might be possible to just have one project but then I would need to use the older codesys with older target device description to develop for devices that have newer device description. Codesys will let me do that but its not recommending it. Any advice?
Last updated: 2026-08-20

Post by felixal on Codesys automatic Data transfer to USB on rasberry pi CODESYS Forge talk (Post)
Hi all, I am currently working on a project where I need to save data automatically on many diffrent USB-Sticks, which are always plugged in the same USB-Port on a Rasberry PI, but I do not get how I can automatically detect the USB devices Folder Name and save a file there on Linux. Thanks!
Last updated: 2024-01-03

Post by dkugler on build (F11) / generate code using a python script file CODESYS Forge talk (Post)
After a project is opened and I have done some changes, I want to start the build or code generating process by a python script file. After the build is done I a Windows sound/beep should appear. Anyone has an example or hint how the .py file has to look like? Thanks!
Last updated: 2024-04-10

Post by ron-rp on Errors with VisuUserManagement library CODESYS Forge talk (Post)
Hi all, I've played a bit with the VisuUserManagement library, and some other security option in my project, and I started getting this error when logging in - see attached pic. something to do with a specific screen in the library - VUM_Login. Also, Codesys started to ask me to log in to the library when logging in, asking to log in as user of the groups Maintainer or Owner, which I dont know either users (attached pic). when I close the login screen and try to log in to the PLC again, everything works again until I close and open Codesys. I do use user and password to login to the PLC, and this login screen is fine I know the user and pass I setup. anyone know what did I do wrong here and how to fix it?
Last updated: 2024-06-25

Post by roundex on CSVReaderInit returns error : INVALID_HANDLE CODESYS Forge talk (Post)
I got same issue but managed to get it to work again by downgrading the Runtime. Here's my specs: CODESYS V3.5.19.0 Runtime Linux SL 4.7.0.0. CSV Utility SL 1.1.0.0 (Licensed IIoT libraries SL) I tried Runtime 4.8.0.0. and 4.9.0.0 but both result in INVALID_HANDLE error.
Last updated: 2023-08-30

Post by taqamert on Codesys 2.3 & Peak PCAN CODESYS Forge talk (Post)
I will use Codesys to program a PLC. I will connect the PLC to the computer via the CAN interface using PEAK CAN, but Codesys does not recognize the CAN adapter. I have added the following libraries. What should I do? What steps should I follow?
Last updated: 2024-07-03

Post by i-campbell on Codesys 3.5 Library Download Failed CODESYS Forge talk (Post)
You use very old codesys, maybe SP13? the newer sp17 libraries are in a format not compatible with your version. I suggest upgrading everything to at least SP17, but may as well go to SP20 Patch 2.
Last updated: 2024-08-21

Post by paulg on CODESYSControl_User.cfg - link to documentation? CODESYS Forge talk (Post)
Is there somewhere in the Codesys help files that generally details what configuration options are available for this file, and what details it logs regarding the configuration file? Or is that going to differ by libraries being used? Thanks!
Last updated: 2024-06-11

Post by thedertom on Help with DynamicTextGetTextW CODESYS Forge talk (Post)
Hi I try to get korean texts out of a textlist. For that I want to use DynamicTextGetTextW, but I am a little confused how it is supposed to work. The function returns POINTER TO STRING, but how do I get WSTRING? I succesfully used DynamicTextGetText with classical Strings. Thanks in advance!
Last updated: 2024-09-02

Post by mos89p on how to use UseDataExpanding() in datasource CODESYS Forge talk (Post)
Hi I need to update by software some structures in my datasource, i found this example: https://content.helpme-codesys.com/en/CODESYS%20Communication/_cds_update_data_interface.html it seems that because i use complex variable structure i need to use UseDataExpanding() instead of use data, the question is how to get an instance of IDatasourcesMgr3 i have the global variable g_Datasources is instantiated automatically
Last updated: 2024-06-18

Post by alsiddhartha on TextList name error (fake) CODESYS Forge talk (Post)
Hello, I’m developing a program and for some reason I got this error: C0193: Name '2,Recipe #2GVL' is no valid identifier I was creating a combo box and creating a TextList for my recipe. I couldn't find where the error was, until in the combo box properties in the 'Text List' property in the options it gives me to select, I found '2,Recipe #2' to be able to select (I never created a list with this name) and I can't find a way to delete that option or I can't find where that list is. I tried to delete the TextLists, delete the combo box, to clean the project, but the error still there. How can I delete this option (2,Recipe #2)? Or how can I fix this error?** Thank you.
Last updated: 2025-06-19

Post by reinier-geers on One project diverent devices CODESYS Forge talk (Post)
Ive got a project with 6 Divices version 9. They use networkvariable to communicate. I whant to add an Extra. But that one is probebly verion 19. Should that be a problem ? i have to update the software to 19. But i cant update the devices
Last updated: 2024-01-12

Post by ameba on PersistentVars and Webvisu Element CODESYS Forge talk (Post)
hello everyone I would like to try to better understand how persistent variables work. I created some boolean variables in the PersistentVars section initialized to the value TRUE. I have tied these boolean variables to toggle switches placed inside the HMI interface pages. Once the PLC program is started, the lever selectors, if operated, change their state, at least at a graphical level, but the persistent variables do not undergo any variation. Initially the above variables were declared as simple global variables, in this case the operation with the levers was correct; I then tried to transform them into persistent ones with the aim of using them as "settings saver" Thank you for support Bye
Last updated: 2025-04-03