how use / convert I/O name or address from array (of strings or other) CODESYS Forge talk (Thread)
how use / convert I/O name or address from array (of strings or other)
Last updated: 2023-01-05

Post by kumareasu on Windows on ARM / Microsoft Surface CODESYS Forge talk (Post)
I too need this information. Is it possible to install CoDeSys runtime and convert a ARM system installed Windows IoT as OS and convert as PLC?
Last updated: 2024-11-16

Post by abjha1998 on Codesys v3.5 Sint to byte CODESYS Forge talk (Post)
Hi everyone, I have been doing a project where I have to send CAN messages from WAGO plc pf200 in BYtes. The signed integer needs to be unpacked into two bytes. so far I have tried Union but that has not worked with me
Last updated: 2024-04-22

Post by phoward131 on Text List Fallback Value CODESYS Forge talk (Post)
I am relatively new to Codesys and I'm trying to develop an HMI that displays what mode a particular device is in based on an integer value. I am currently using dynamic texts with a text list which works fine but I am looking for a way to display a particular string (ie 'Unknown') when the index doesn't match any of of the indices in the text list. I can enter 'Unknown' in the text property of the text field element which works as expected but it displays the single quotes on the visualization. How can I escape these quotes to simply display the word Unknown? Thanks!
Last updated: 2024-03-22

Post by kislov on Formatting Integer CODESYS Forge talk (Post)
https://content.helpme-codesys.com/en/CODESYS%20Visualization/_visu_placeholder_with_formatting_sequence_in_a_string.html Use %03d
Last updated: 2024-06-14

Zugriff auf BYTE in einem WORD / INT in einem DINT etc... CODESYS Forge talk (Thread)
Zugriff auf BYTE in einem WORD / INT in einem DINT etc...
Last updated: 2023-01-19

schaltplan als PDF-Datein oder als ein Bild in MS-WORD CODESYS Forge talk (Thread)
schaltplan als PDF-Datein oder als ein Bild in MS-WORD
Last updated: 2007-10-05

Post by stdenits on Set several bits in WORD CODESYS Forge talk (Post)
DEL
Last updated: 2024-04-23

Post by aarondw10 on Use element properties CODESYS Forge talk (Post)
Assume I have a rectangle named rec1 from which I want to use the coordinates of the upper left corner. Is there a way to links these X and Y values from the properties to an integer defined in the main program? Note that I just want to use them and not change any of these coordinates in the program.
Last updated: 2024-02-29

Post by nico01 on Integer with comma in visualization CODESYS Forge talk (Post)
Hello everyone, I created a visualization with a lot of REAL, with one or two digits after the decimal point. This causes me problems in terms of rounding and memory... is it possible to display an integer with a comma, like with PROFACE or SIEMENS? It's just an "abuse" of display, the comma is just on the visualization. This limits the memory (16 versus 64 bytes) and rounding is easier to manage... See print screen on proface software THANKS
Last updated: 2023-09-20

Post by ahmedbadawi10 on Codesys Trend Problem CODESYS Forge talk (Post)
I have control win v3 with simulation and a small program with function to convert analog values to percentages, I need to show these percentages in a trend chart, but nothing is shown in the trend as you see in snips attached! thanks in advance
Last updated: 2025-09-16

Post by tvm on Timer On Vijeo CODESYS Forge talk (Post)
Vijeo doesn't support TIME variables, so the easiest thing to do is convert to a STRING in your program, and use that variable. You could use TimeAsString:= TIME_TO_STRING(TimeVar) to get a string that looks like this: T#5h10m45s200ms
Last updated: 2024-05-07

Post by garrian on How to write multiple coils (Modbus FC15) CODESYS Forge talk (Post)
Thanks for your reply. I belive it is contiguous, I'm writing to adress 0 to 4. Or, do you mean something else? Well, something is happening. If I on the client set adress 1,2,3 to true, only 1 is set to true on the server side. On the client side, the data is array of word. But on the server side, the coils are array of bool. Holding register is array of word on server side. Can this be a problem? Attached screenshot of how it looks at the server side.
Last updated: 2024-11-17

Post by dkugler on Converting hex bytes to float CODESYS Forge talk (Post)
have a look at UNIONs. With a union you are able to write single bytes to the same adress area which belongs to a float variable at the same time. I like to do a lot of convertions belonging to interfaces and fieldbus in this way, f.eg. word / byte swapping etc.
Last updated: 2024-08-06

Post by alimans on Hex string CODESYS Forge talk (Post)
Hi kdkwhite, for Word you still can use suggested code by using a union structure and crack down your Word to two byte as bellow: TYPE CrackWordToByte : UNION InWord : WORD; OutBytes : ARRAY [0..1] OF BYTE; END_UNION END_TYPE then define your variable as this type: udInput : CrackWordToByte; now assign your Word variable input to InWord and send OutBytes[x] to the mentioned method: udInput.InWord := WordVariableInput; Input := udInput.OutBytes[x]; Regarding your question about the code: actually 48 is ascii code of "0" and while 65 is the ascii code of "A" so in above code 55 + 10 would be 65.
Last updated: 2023-09-20

Post by ben1 on How to write multiple coils (Modbus FC15) CODESYS Forge talk (Post)
Yeah that is odd - sometimes you have to do what you have to do unfortunately. Have you tried sending consecutive bits in the word instead - ie. instead of [0].0. [1].0, [2].0 etc, send [0].0,[0].1, [0].2 etc. ?
Last updated: 2024-11-17

Post by davidbo on Modbus: Is there a way to get the channel index from the channel name? CODESYS Forge talk (Post)
When I use the FUNCTION_BLOCK ModbusChannel I have to sepcify the integer iChannelIndex It can easily go wrong if one has many channels. It would be better if one could use the name. Is that possible? Attached a snippet of the channel name and the channel index to the left.
Last updated: 2024-10-21

Post by reinier-geers on JSON (WString format) accessing elements. Convert to STRUCT? CODESYS Forge talk (Post)
HI , Ill try the same with Energy prices. But no data I add the Query to the wsPost. Add $ because wstring use "as start end end. Here the link of the API info https://reversed.notion.site/Marktprijzen-API-89ce600a88ac4abe8c2ad89d3167a83e
Last updated: 2025-10-09

Post by reinier-geers on JSON (WString format) accessing elements. Convert to STRUCT? CODESYS Forge talk (Post)
HI , Ill try the same with Energy prices. But no data I add the Query to the wsPost. Add $ because wstring use "as start end end. Here the link of the API info https://reversed.notion.site/Marktprijzen-API-89ce600a88ac4abe8c2ad89d3167a83e
Last updated: 2025-10-09

Post by snhatton on Integer with comma in visualization CODESYS Forge talk (Post)
Here is some information about formatting different variables types: https://content.helpme-codesys.com/en/CODESYS%20Visualization/_visu_placeholder_with_formatting_sequence_in_a_string.html I hope this helps!
Last updated: 2023-09-20

Post by bjarne-pagaard on Newly created texlists wont appear in the selection dropdown CODESYS Forge talk (Post)
I just had the same problem in 3.5 SP19 Patch 6. Trying to use a textlist for Combobox Integer element. The textlist cannot be selected in the IDE, and is not found when manually entering the name. The textlist is copied to the device, but is not used. Can confirm, that copying an existing textlist and renaming it does work.
Last updated: 2024-12-16

Post by liamb on Converting CANbus to Decimal from signed 2's complement CODESYS Forge talk (Post)
I need to combine two 8 bit CANbus messages to 16 bits signed int then convert to decimal Decimal from signed 2's complement. I've been using the below code to read for new messages, combine them then assign them to a variable What is the best way to do this for from signed 2's complement? fbRxMessage351(Data := RxMessage351Data); IF fbRxMessage351.NewMessage THEN ChargeVoltage := (WORD_TO_REAL((RxMessage351Data[0]) + ((RxMessage351Data[1]) * 256))) * 0.1; END_IF
Last updated: 2024-08-16

Post by k2saki on CNC Open Source Project / Can I convert my project to text-files ? CODESYS Forge talk (Post)
Hi. I published My CODESYS-CNC Project to GitHub and I set it Open Source Software. Here https://github.com/k-s-saki/RPi_CODESYS_CNC My CNC Project is binary file , using FBD for IPO , so I found it is a little bit hard to work with people on GitHub. (diff / merge ) My question is 1) Is it possible to convert my project ( only POUs is also fine ) into text file ? How? 2) Would it be better to rewrite all FBD/LD into ST and copy them manually to text files? Thanks.
Last updated: 2024-05-16

Post by risele on Modbus connection via Qronox PCD3 M6893 CODESYS Forge talk (Post)
First, if you don't need to change conversion rules in runtime, take a look at "Unit conversion" module (Application -> add object -> UnitConversion). You can specify there biderectional conversion with different units, limits and so on. Second, since MODBUS don't have "real" types but only general 16-bit registers and Real is 32-bit, generally you need a byte-was conversion Real <> two Words. Note, that depending on the devices on both sides, there are two options: Real-> Word1, Word2 or Real-> Word2, Word1, where Word1 is minor register in Modbus register pair and Word2 is major. You can use simple union: TYPE u_Real : UNION rVal:REAL; wVal:ARRAY[0..1] OF WORD; dwVAL:DWORD; //same as previous, may be easier to specify the MB register END_UNION END_TYPE and convert it as following: VAR myUnion:u_Real; rValue_TO_SEND:REAL; rValue_TO_GET:REAL; END_VAR myUnion.rVal:=rValue_TO_SEND; rValue_TO_GET:=myUnion.rVal; Note, that WORD-order should be properly set in MODBUS registers, otherwise you will get strange values. This tool is helpful: https://www.scadacore.com/tools/programming-calculators/online-hex-converter/ Alternative, you can use functions as REAL_TO_DW and DW_TO_REAL from OSCAT_BASIC, for example.
Last updated: 2026-02-19

Post by abjha1998 on Converting UINT into bytes and converting 2Bytes into UINT CODESYS Forge talk (Post)
Hi, I have been working on Codesys V3.5 with PFC200 controller and Can Gateway 750-658. I want to convert the incoming CAN data from bytes into UINT and for outgoing data bytes to UINT. Does anyone has experience with this kind of data? I tried few different ways but it doesn't seem to be working.
Last updated: 2023-12-07