Post by faceplant on Comparison via CLI is broken
CODESYS Forge
talk
(Post)
Hello! I am trying to compare 2 projects via the --compare CLI option. In the docs for the --compare option, it describes the usage as .\CODESYS.exe --compare "project path 1" "project path 2". I store my projects in WSL2 on my windows machine. Since CODESYS is happy to open those projects via a path like \\wsl.localhost\home\project.project. So, to compare, I use the command .\CODESYS.exe --compare "\\wsl.localhost\home\prog1.project" "\\wsl.localhost\home\prog2.project". This results in CODESYS just opening the project and starting, not comparing the two projects. No errors are thrown, and I know the paths are correct since I can open both independently in CODESYS, and I can compare them manually through the CODESYS UI. I have also tried moving my projects to the Windows 11 OS and still have the same issue. CODESYS opens the project and does not actually compare them. I am using CODESYS profile v3.5 sp20 patch 1. What is the correct way to compare 2 projects using the --compare CLI option?
Last updated: 2024-12-18
Post by gerdkoch on Dynamic I/Os Mapping
CODESYS Forge
talk
(Post)
Hi, I assume that you have a Pfc200 G2 or something and work with the original WAGO runtime. Then I would recommend the WagoSysDynamicIoMapping. Here in the example projects there is a PDF file for the library: https://downloadcenter.wago.com/learning-material/details/ll0w3pmdunzvem83g1 There is a global functional component in a GVL of the library. I think it's called DynKbusIoManager or something. The active terminals are registered there. Then there are filter Fb's for e.g. the first clamp with a specific article number. Everything is in the PDF.
Last updated: 2023-08-18
Post by transmin01 on CANbus issue
CODESYS Forge
talk
(Post)
Update: This initial issue was when using a Linux target PLC. Since then I have created a Win10 target PC and the Codesys software reported an issue associated with the device version (see attached). I am assuming this is an incompatibility with the xml file from the manufacturer and the firmware version on the module and I am chasing this up with Beckhoff. Question is, why would this not report with a Linux target?
Last updated: 2023-09-14
Post by docker on Canopen connection. Unknown node id.
CODESYS Forge
talk
(Post)
hi, i am currently trying to adapt an i/o device for a project. the node id is unknown and there is no eds file available. no data is being emitted from the device as a giveaway, the baudrate is known but useless without the node id. is there an sdo request available to determine the id? i cannot get the device to leave pre op status even with a global nmt request. please help. no hair left.
Last updated: 2023-09-25
Post by john-martin on Send file from codesys to...... ftp, cloud, etc
CODESYS Forge
talk
(Post)
Hi everybody, I am looking for a solution to send files, for example, to an ftp or a cloud. I can't use oscat library because 64 bit controller are not supported. Therefore, I see that the IIoT library has some functions that might help me to implement this sending process in codesys. Does anyone have any examples of how to do this? I have spent some days with this issue without success. Best regards.
Last updated: 2023-11-02
Post by drno on AlarmMgr Database Error in method WriteToStorage: Error code = 30531, Action = 1030
CODESYS Forge
talk
(Post)
Hallo zusammen, auf einer Industriesteuerung (Target-Version 3.5.5.0) läuft unter anderem eine Alarmverwaltung mit Alarmspeicherung. Offensichtlich kann kein Schreibzugriff auf das .sqlite File durchgeführt werden, daher ist die Alarmhistorie nicht mehr verfügbar. Versuche mit unterschiedlichen Unterverzeichnissen führten nicht zum Erfolg. Die Datei "application.alarmstorage.sqlite" wird zwar angelegt, aber es erfolgen keine Einträge. Hat jemand eine Idee dazu? Die Steuerung ist ca. 8 Jahre in Betrieb, die Alarmhistorie hat früher mal funktioniert. Danke, LG
Last updated: 2023-11-21
Post by taqamert on Codesys 2.3 & Peak PCAN
CODESYS Forge
talk
(Post)
Despite working on it for days, I haven't achieved any results. I followed the necessary steps one by one as mentioned in the file you sent, but there hasn't been the slightest change. I couldn't find the step you mentioned "Set the 'Can Board Type' to PCAN USB" in the Word document. There is no such setting anywhere I looked. Is there a more detailed explanation available, or can you explain it in more detail? What am I missing?
Last updated: 2024-07-16
Post by kleeswi on Visualization scaling problem with B&R T30 panel
CODESYS Forge
talk
(Post)
I have found a work around. I have written a python scripts that runs on user login (entry in .bashrc) which overwrites the webvisu.htm and webvisu.cfg.json file with the configuration for the B&R T30 panel (resolution and disable scaling). First I tried to add this setting to the the CODESYSControl.cfg, but that does not work following the big CODESYS Control V3 Manual. [CmpTargetVisu] Application.WindowPositionX=0 Application.WindowPositionY=0 Application.WindowSizeWidth=800 Application.WindowSizeHeight=480
Last updated: 2024-07-30
Post by pavanifm on Test a manager script (.tsd file{xml document}) not starting from Git CI heedlessly/ without ui
CODESYS Forge
talk
(Post)
'--noUI' option of Command line interface for test manager test script not executing when triggered from CI as well as from Local PC however is it working for execution of python scripts from CLI. can we start codesys test manager scripts from CLI interface without any GUI in background process of windows? i can see simlillar questions asked but no answer yet. otherwise, what is the solution to built test automation framework using Test Manager & GIT CI/CD?
Last updated: 2024-08-07
Post by pavanifm on Test a manager script (.tsd file{xml document}) not starting from Git CI heedlessly/ without ui
CODESYS Forge
talk
(Post)
'--noUI' option of Command line interface for test manager test script not executing when triggered from CI as well as from Local PC however is it working for execution of python scripts from CLI. can we start codesys test manager scripts from CLI interface without any GUI in background process of windows? i can see simlillar questions asked but no answer yet. otherwise, what is the solution to built test automation framework using Test Manager & GIT CI/CD?
Last updated: 2024-08-07
Post by pavanifm on Test a manager script (.tsd file{xml document}) not starting from Git CI heedlessly/ without ui
CODESYS Forge
talk
(Post)
'--noUI' option of Command line interface for test manager test script not executing when triggered from CI as well as from Local PC however is it working for execution of python scripts from CLI. can we start codesys test manager scripts from CLI interface without any GUI in background process of windows? i can see simlillar questions asked but no answer yet. otherwise, what is the solution to built test automation framework using Test Manager & GIT CI/CD?
Last updated: 2024-08-07
Post by pavanifm on Test a manager script (.tsd file{xml document}) not starting from Git CI heedlessly/ without ui
CODESYS Forge
talk
(Post)
'--noUI' option of Command line interface for test manager test script not executing when triggered from CI as well as from Local PC however is it working for execution of python scripts from CLI. can we start codesys test manager scripts from CLI interface without any GUI in background process of windows? i can see simlillar questions asked but no answer yet. otherwise, what is the solution to built test automation framework using Test Manager & GIT CI/CD?
Last updated: 2024-08-07
Post by pietrobalint on Retain / Persistent Variables in Codesys for Raspberry Pi
CODESYS Forge
talk
(Post)
Hi micik, I am not sure I am using well the code, because I checked the directory and there is no retains.ret file. Now I deleted the code from my project and the values are still works as persistant variables after ssh reboot it seems to me they retain as their previous value. So I am a bit confused, maybe 4.12.0.0 Raspberry Pi SL solved the persitent variable problem...
Last updated: 2024-08-20
Post by wbj0t on tool 'update raspberry pi' unavailable
CODESYS Forge
talk
(Post)
Doesnt matter. I have installed sp20 with latest RP 4.13. Same problem. Anyway My large project in RP 4.10 and SP 19 and I need these versions and use same installation programm for Codesys IDE and RP4 package. I did install again, because my SSD broke and now cant update raspberry... I dont know how to translate correctly project to newest version - there are 52769 errors and incompatabilities: after updates libraries anyway some errors still because of devices... I found solution with .deb file from raspberry package - dont need IDE anymore for update raspberry.
Last updated: 2024-09-27
Post by totorovic on Hard shutdown: no code on device after power on
CODESYS Forge
talk
(Post)
However, if faulty EtherCAT cables were the issue, why wouldn't the error occur during normal operation? Why would bad cables only cause problems during a hard shutdown? I don't have the answer to this question. One last question: When you encountered this behavior, did you see a similar error in your logs? i.e, an "AccessViolation" exception in the EtherCAT Task Yes. It was the exeption you can see in attached file.
Last updated: 2024-10-03
Post by dkugler on csv datei einlesen und verarbeiten
CODESYS Forge
talk
(Post)
in der https://store.codesys.com/de/codesys-iiot-libraries-sl.html ist u.a. die CSV Utility SL Bibliothek incl. Beispiel enthalten. Die kostet etwas. Generell Codesys Beispiele findest Du hier: https://content.helpme-codesys.com/de/CODESYS%20Examples/_ex_start_page.html Alternativ file read verwenden und Zeit investieren um von Hand zu Fuß den Dateiinhalt zu durchforsten: https://content.helpme-codesys.com/de/CODESYS%20Examples/_ex_cds_file_utilities.html In der OSCAT Library gab es mal noch etwas, da könnte google weiterhelfen
Last updated: 2024-10-28
Post by jeroenaero on CodeSys Raspberry pi I2C driver not found
CODESYS Forge
talk
(Post)
Finnaly i get it working. There was a line in the file that set the ADS1015 chip in /boot/firmware/config.txt which i removed and after that the ADS1115 has a green turning circle and i got values. i created a new component so it fits our ADS1015. see screenshot. It works also with Codesys Control for Raspberry Pi 64 SL after adding the ULINT_TO_UDINT conversion in the library. i think the chip was all the time in use by the Raspberry pi itself. Thanks for your help!
Last updated: 2024-11-12
Post by s1ack on PFC200 Will soft-container & IIoT license survive a firmware update?
CODESYS Forge
talk
(Post)
I have an IIoT License activated on a PFC200 with older firmware 2.08.32 (11). If I flash it to the latest available 4.05.10 (27) does the license get destroyed? I have a back up file '3SLicenseInfo.tar'. But this looks quite a bit different form the backup I got from more modern firmware... 'CMLicenseNew.WibuCmRaU'. Can the new license manager restore it from the old .tar?
Last updated: 2024-11-12
Post by eschwellinger on Codesys Tools Update Raspberry ist nicht vorhanden aktualisieren im Geraete ansicht geht auch nicht
CODESYS Forge
talk
(Post)
Hallo Alex, hier im Deploytool gibt man nur an welches Packet man installiert - das deploy Tool schaut auf dem Zielsystem: Ist es ein Arm64 oder Arm 32 System: Abhängig davon wird für 64Bit: Für Pi MC: armv7l Für Pi SL: armv6l Für Pi 64: aarch64 Beispiel Pi 64B it OS [CmpRasPi] Architecture=aarch64 in /etc/codesyscontrol/CODESYSControl_User.cfg gesetzt. Sprich wenn du das ändern willst kannst du das in diesem Config File ändern oder aber hier im Deploy Tool:
Last updated: 2025-01-23
Post by respl on IFM EXOR Network variable Error
CODESYS Forge
talk
(Post)
We are connected IFM CR711S to Exor EX710. We are exchanging data using network variables. Both devices are configured on same project so no need to use file source. When tested application it works fine. But after 3 months same application not working. We are able to send data from CR711 to EX710 but data from Ex710 to CR711s works only for one scan when we cold reset CR 711S. Can somebody help to find out error.
Last updated: 2025-03-17
Post by simone on Preferred way of managing Ip-adress/es for linux (debian) host?
CODESYS Forge
talk
(Post)
Hi pernockham, I think you should ask your device vendor. For some time I used one from an Italian company where they had made a library where you can manage the ip with a function (something like SetIPAddr...), it was based on connmann on linux. From my little experience is better to use the "default" way, so for me is to manage the config file on interfaces or use the ip addr utility
Last updated: 2025-03-24
Post by ggis on Manage Gateways between different CODESYS IDE versions
CODESYS Forge
talk
(Post)
Hi, I'd like to share the list of gateways between different versions (and sandboxes) of Codesys IDE. I refer to the list that is managed in Device > Communication Settings (as described in https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_edt_device_communication_settings.html ) Can I export/import that list? Or is there a file that I can copy from one installation to another one? Thank you GG
Last updated: 2025-05-28
Post by berkdan on SMC_ReadNCFile2 is always busy
CODESYS Forge
talk
(Post)
Hello, I’m using CODESYS V3.5 SP18. When I try to use SMC_ReadNCFile2 to read the file /PlcLogic/gcode.nc, the function block's bBusy output remains TRUE indefinitely. Can you help me understand what I might be doing wrong? Here is how I’m calling the function block. The value of strFileName is 'gcode.nc'. fbReadFile( bExecute := bExecute, sFileName := strFileName, bAbort := bCycleStop, fDefaultVel := RetainVariables.xSlowVelocity, fDefaultAccel := RetainVariables.xAcc, fDefaultDecel := RetainVariables.xDec, b3DMode := TRUE, bParenthesesAsComments := TRUE, fDefaultVelFF := RetainVariables.xFastVelocity, fDefaultAccelFF := RetainVariables.xAcc, fDefaultDecelFF := RetainVariables.xDec, ErrorID => gCNC.eErrorId, errorPos => gCNC.eErrorPos, ErrorProgramName => gCNC.eErrorProgName, bBusy => bReadFileBusy, sentences => sentencesss ); Thanks in advance for your help.
Last updated: 2025-06-16
Post by nguyenkhoi on Omron R88D-KN08H-ETC with a raspberry on top... (over ethercat)
CODESYS Forge
talk
(Post)
hi everyone, continuing the part about omron g5 axis and nx-ecc201 omron, but i have a problem with not being able to scan with "model with Z code suffix of omron china", it seems that the available softmotion file is not fully compatible mapping, often causing ethercat communication error DC distributed clock after every 10-12 hours of continuous running! omron driver: R88D-KN08H-ECT-Z
Last updated: 2025-07-01
Post by arwie on Working on exporting/importing projects to PlainText.
CODESYS Forge
talk
(Post)
To better track project changes in git I created a script that exports the project structure as text files. Textual POUs are stored as text, everything else as XML (with timestamps removed). The file structure is stored under path/to/your.project.txt Git merge will not work, but at least tracking changes is much easier. Script: https://github.com/arwie/controlOS_demo/blob/main/codesys/txtfy.py Example output: https://github.com/arwie/controlOS_demo/tree/main/codesys/controlOS_demo.project.txt