Post by aliazzz on Unable to deploy Virtual Control SL on ARM64 (Raspberry Pi5)
CODESYS Forge
talk
(Post)
Hi, I have successfully deployed "Virtual Control SL" on a few x86/64 machines now. However, I'd now like to deploy this to a Raspberry Pi (ARM64). To do this I prepared the Raspberry Pi5 with the following prereq's; * Minimal PREEMPT Debian * Latest Bootfirmware * full SSH access via non-root account * Podman * RedHat Cockpit with CODESYS LicensServer plugin up and running However, I can't seem to resolve copying the correct (deploy) Images as they wont show up in the CODESYS IDE I have added CODESYS Virtual Control for Linux SL and the CODESYS LicenseServer for Linux SL via the CODESYS installer on my DevBox. I open CODESYS > Tools > Deploy Control SL Next I enter the SSH targets IP and Credentials and for my RPi5 and it shows "Connected". In the next tab, Deployment, the dropdown box only shows one (1) image, which also is the incorrect CPU architecture. Only Virtual Control AMDx64 shows up (!?) while I expect to see the ARM64 based images for both Edge and Control. Has someone encountered this too? I'd like to hear other people experiences with Virtual Control deployment on ARM based architecture. attachment 1: AMD64 based deployment pulldown menu (correct images) attachment 2: ARM64 based deployment pulldown menu (incorrect images) regards,
Last updated: 2024-07-28
Post by mwandy on Codesys Project Protection
CODESYS Forge
talk
(Post)
I'm having trouble finding clear answers on this. I'm looking for a way to make a Codesys project password protected so that if the project is distributed it can be used to log into a controller to view and debug logic. At this same time I want to prevent the project from being saved as well as edits being downloaded to the controller. Basically I want to make a whole project view-only. What is the beat way to achieve this? I have had minor success with access rights, which solves the problem with trying to login if the project doesn't match what is in the controller. However with this solution, edits can still be made and saved, possibly corrupting the core project, preventing future logins. Any suggestions?
Last updated: 2024-03-29
Attempt to upgrade a pi 3 from a working V3.5.11 to V3.5.15 fails
CODESYS Forge
talk
(Thread)
Attempt to upgrade a pi 3 from a working V3.5.11 to V3.5.15 fails
Last updated: 2021-07-13
It it possible to connect 100 EtherCAT Slaves to a Codesys Master on a RaspberryPi 3
CODESYS Forge
talk
(Thread)
It it possible to connect 100 EtherCAT Slaves to a Codesys Master on a RaspberryPi 3
Last updated: 2020-12-14
it is possible to add a function template to a program from scripting ...
CODESYS Forge
talk
(Thread)
it is possible to add a function template to a program from scripting ...
Last updated: 2018-05-25
Post by tk096 on SMC_Interpolator + SMC_controAxislbyPos
CODESYS Forge
talk
(Post)
Hi, you can define a start position for your GCode. How the start position can be defined depends on the CompileMode: For File and SMC_CNC_REF: Set the start position input of SMC_NCInterpreter (https://content.helpme-codesys.com/en/libs/SM3_CNC/Current/SM_CNC_POUs/NC2/Interpreter/SMC_NCInterpreter.html) For SMC_OutQueue: * Right-click on the CNC object in the project tree * Select Properties * Select the tab 'CNC' * Set the start position Concerning your second question: If the new set position cannot be reached with the given velocity limit (AXIS_REF_SM3.fSWMaxVelocity), SMC_controlAxisByPos will report bStopIpo and close the 'gap' with the given gap dynamics (SMC_controlAxisByPos.fGap*).
Last updated: 2024-02-07
Post by saugat10 on I have errors while building the project
CODESYS Forge
talk
(Post)
I have some errors as you can see in the picture when i build the project. I have not been able to trace back to the error and i have no idea where to look at to fix this issue. What is GVL_Io? Is it related to some library?
Last updated: 2024-04-10
Post by vformanek on No source code available for profinet library
CODESYS Forge
talk
(Post)
Hello, I have been using CODESYS for a while and after updating to version 3.5.18.50 the code randomly stops with this fault. Why is that ? I have tried to locate the fault in the Call Stack but I dont know what to do now... I have updated the projects properly for the version I am using. This fault started happening after like 14 days of using the new version of CODESYS.
Last updated: 2023-08-23
Post by vformanek on Datasource OPC UA Client error ID:7012
CODESYS Forge
talk
(Post)
Sorry to bother but what do you mean by target ?
Last updated: 2023-11-21
Post by ewi04 on How to upload application file to remote controller (offline) ?
CODESYS Forge
talk
(Post)
Thank you very much for your time and replay! Sounds like a good idea. Unfortunately, I have no other option to run the code from the running plc. So, I can’t stop any services. If anyone has the same problem, I've gotten a little closer to understanding it: Sometimes the copied files are empty after the restart. The update code checks if there are any empty files. Before I turn off the device, everything is okay. But after starting, some files are suddenly empty and that cause the problems. I don't know why this happens.
Last updated: 2024-02-16
Post by jarnok on How to know if output if function block is used
CODESYS Forge
talk
(Post)
Hi, Is it possible to know of an output of a function block is used? I've found there is a way to find unused inputs of a fb, through the attribute: is_connected. But I'm wondering if the same can be done for an output. Thanks in advance!
Last updated: 2024-10-15
Post by ryusoup on OPC UA Client certificate for datasource link
CODESYS Forge
talk
(Post)
Hello, I'm looking for a way to set my client certificate, not one which self-signed cert generated with CODESYS, for OPC UA connection via datasource linking. Does anyone know how to archive that? BR,
Last updated: 2024-03-08
Post by ggis on Unable to connect to git remotes through Codesys.
CODESYS Forge
talk
(Post)
When trying to connect to a Github repository in the Git remotes windows of Codesys, the user can be the account username or the account email, while the password is the Github token. (I know this is an old topic, but I lost some time figuring it out from the guides.)
Last updated: 2023-11-10
Post by khaledkhalil on Question about the hairaichy of UaExpert
CODESYS Forge
talk
(Post)
Hello, I am Examining this Example from Codesys Tutorial about OPC-UA server here https://www.youtube.com/watch?v=aJhzN3Uk-Do&list=PLWtD08CpmZcSV26aWh1axCAef5c5HxX-3&index=1&t=1167s. Now i am running to problem, when i create instances and i want them to appear directly under the object directory, However, it always appear with me under Objects >> Device set >> Device Name in CODESYS. I need to know how i can change the directory of my instances 'inst_3' and so on. So they can be under objects directly. I tried to modify the settings, but couldn't find any leads till now. Thanks in advance for helping
Last updated: 2024-09-12
Post by struccc on Release SP20 - Changes in behaviour?
CODESYS Forge
talk
(Post)
Dear all, I've just started to migrate some of my ancient projects to SP20. There is one strange error (?) I have noticed so far. In a method call, depending on the circumstances I would like to return reference to an object, or an invalid reference: METHOD Add_EVT_OUT : REFERENCE TO FB_MSG VAR END_VAR IF __ISVALIDREF(refMSG_Entry) THEN Add_EVT_OUT REF= MANAGER.AddMsg_EVT_OUT( refMSG_Entry, _Get_EVT_Message(MSG_EVENT.OUT), _Get_EVT_AddCode(MSG_EVENT.OUT) )^; ELSE Add_EVT_OUT := 0; END_IF So far setting a reference variable to 0, did this. But now, the expression Add_EVT_OUT := 0; gives an error: [ERROR] DB_WTP_370: Add_EVT_ACK MSG_TRIGGER_EXT: C0032: Cannot convert type 'BIT' to type 'REFERENCE TO FB_MSG' Naturally... I can write: Add_EVT_OUT := DWORD#0; But is this the correct way? Is there any constant I could use instead, like "NULL"? Or this is totally wrong and to be avoided?
Last updated: 2024-03-24
Post by victor on Trend-Trace / Time x-axis
CODESYS Forge
talk
(Post)
Good morning, I am new to codesys, I am currently manipulating the Trace and Trend elements and I would like to know if it was possible to configure a variable or a trigger to reset the "X" axis to 0. have a good day.
Last updated: 2024-01-26
Post by eschwellinger on Html5 controls error
CODESYS Forge
talk
(Post)
which plc in which version are you using?
Last updated: 2024-01-29
Post by tomast on Communication PLC with HMI - how to send DUT via NVL.
CODESYS Forge
talk
(Post)
Hi everyone, I am working with project where i have DUT wihth struct. I would like to fill this data trough a form on HMI. I use NVL to communicate and i would like to know how is it possible to do this? Thanks for all your advice in advance.
Last updated: 2024-08-23
Post by dhumphries on How to address visualization change with button press...
CODESYS Forge
talk
(Post)
you can configure the button actions in the hotkey tab in the visualization.
Last updated: 2024-03-15
Post by timvh on Display minutes as hours & minutes
CODESYS Forge
talk
(Post)
You could use the Modulo function to get the minute part from the total minutes: Minutes := TotalMinutes MOD 60;
Last updated: 2024-05-27
Post by rossanoparis on RevPi CONNECT+, CODESYS, EtherCAT master "Filedbus lost synchronicity"
CODESYS Forge
talk
(Post)
Hello @rmaas I assume, you've already verified and tuned everything regarding the EtherCAT network. In my case the problem was due to a wrong core assignement. I suggest to not use the core #0 for your EtherCAT task. The OS realtime patch, which is present on RevPi OS, uses the core #0 for its porpouses and it mustn't be used by any other task which requires realtime and deterministic features. regards Rossano
Last updated: 2024-04-11
Post by simotion on Axis variable indicating modulo of finite setting
CODESYS Forge
talk
(Post)
What variable of the axis indicates it is a modulo of finite axis? I want to check that in the code, to adopt my motion code between the two types.
Last updated: 2023-11-24
Post by ofey on Device parameter - ‘ModbusTCP Configuration’
CODESYS Forge
talk
(Post)
Hi! Do anybody know how I can add and enable the parameter 'Default Modbus TCP slave' on a device? I am currently writing a program where the PLC shall be set up as a Modbus TCP client, but I dont know how to add parameters to devices in codesys. I'm pretty new to the codesys environment. The picture in the attachment is on a similar PLC project where I have not written the code. my goal is to add this parameter in another project.
Last updated: 2023-10-04
Post by rringo on Function block not autofilling
CODESYS Forge
talk
(Post)
I am attempting to place a block and make it an Analog sensor. When I go to change the name like in the instructional video on youtube it does not give me an option to autofill the block with a known configuration. This is a problem I have in Codesys 2.5 and 3.5. Did I mess up the install of the program or need to install a library? Any help would be appreciated. https://www.youtube.com/watch?v=PkJYQeIUmIM&t=136s at time mark 2:15ish The first image is what I can do and the second is what the videos function autofills to.
Last updated: 2023-08-24
Post by arundara on Variable Sync Issue In Soft Plc Redundancy
CODESYS Forge
talk
(Post)
Hello, I was trying to create a redundancy POC for our application where we read data from few modbus tcp devices. As there is a limitaion that modbus tcp device support only for single master device, we wanted to test how the variable sync happens in redundancy mode. For that i have used the redundancy sample code added a variable "b" under a condition. What i observed was while active controller is running, if passive controller is powerup, passive controller is able to sync all the data configured for redundacny. But after that the variable data which resided under a condition is not synching from active to passive controller. I have attached the image where i have highlighter the variable. Can some help me to understand how redundacny work in codesys soft plc and if there is a solution to sync variable which are under condition, please explain the same or suggestion to achieve the same. Hardware - Raspberry Pi (2 qty) Redundancy licence used - yes in both controllers. Codesys runtime - 4.9.0.0 Codesys software version - V3.5 SP19 if i have posted this question in wrong section, please do let me know in whcih section i have to post this question.
Last updated: 2023-12-01