Search talk: -128到127是什么数据类型

 
<< < 1 .. 57 58 59 60 61 .. 887 > >> (Page 59 of 887)

Post by voffi on Converting UINT into bytes and converting 2Bytes into UINT CODESYS Forge talk (Post)
There are some ways. One is to use SHR and SHL and it depends on your byte order in the data array. For Motorola byte order: PROGRAM PLC_PRG VAR u : UINT; byte_array_in : ARRAY [1..8] OF BYTE := [16#11, 16#12, 16#13, 16#14, 16#15, 16#16, 16#17]; byte_array_out : ARRAY [1..8] OF BYTE; END_VAR u := SHL(TO_UINT(byte_array_in[2]), 8) + TO_UINT(byte_array_in[1]); byte_array_out[1] := TO_BYTE(u); byte_array_out[2] := TO_BYTE(SHR(u, 8)); If it's Intel byte order just change 1 and 2 in the array indexes.
Last updated: 2023-12-07

Adding a variable from text list into ST code CODESYS Forge talk (Thread)
Adding a variable from text list into ST code
Last updated: 2023-12-07

Post by talhaali on Adding a variable from text list into ST code CODESYS Forge talk (Post)
Hi, can I use a entry of a text list as variable in structured text? for example in attach picture, if i use want to use data of first row. I am trying to write: A : STRING := TextList.Default.0; but it is not workings
Last updated: 2023-12-07

Post by talhaali on Adding a variable from text list into ST code CODESYS Forge talk (Post)
Hi, can I use a entry of a text list as variable in structured text? for example in attach picture, if i want to use data of first row. I am trying to write: A : STRING := TextList.Default.0; but it is not workings
Last updated: 2023-12-07

Adding a variable from text list into ST code CODESYS Forge talk (Thread)
Adding a variable from text list into ST code
Last updated: 2023-12-07

Post by kumareasu on Hydraulic Axis Controller CODESYS Forge talk (Post)
I want to make Hydraulic Axis Controller with Linear encoder feedback. Any library available ?
Last updated: 2023-12-08

Post by open on How to create a stopwatch? CODESYS Forge talk (Post)
Hi @ph0010421, I tried the program the TimeTaken is calculated when stop is triggered. I want the TimeTaken to be continuously calculated and counting when a BOOL variable is true. I tried to program this way: Declaration: PROGRAM PLC_PRG VAR bStartStop: BOOL := FALSE; // Start/Stop button bReset: BOOL := FALSE; // Reset button bRunning: BOOL := FALSE; // Flag indicating whether the stopwatch is running tStartTime: TIME; // Variable to store the start time tElapsedTime: TIME; // Variable to store the elapsed time END_VAR Implementation: // Main program logic IF bReset THEN // Reset button pressed, reset the stopwatch bRunning := FALSE; tElapsedTime := T#0s; ELSIF bStartStop THEN // Start/Stop button pressed, toggle the running state IF bRunning THEN // Stop the stopwatch bRunning := FALSE; ELSE // Start the stopwatch bRunning := TRUE; tStartTime := tElapsedTime; END_IF; END_IF // Update the elapsed time when the stopwatch is running IF bRunning THEN tElapsedTime := tElapsedTime + T#1s; // Adjust the time increment as needed END_IF However counting of the seconds is not accurate. I tried changing the main task cycle time interval to 1000ms. The counting of seconds become slower. (see attached) Please help
Last updated: 2023-12-08

Post by dileesha on Codesys device configuration CODESYS Forge talk (Post)
I am new to this and I have a Beijer X2 Control 7 HMI and in my laptop I have installed codesys v3.5, ix developer and codesys gateway control. I have designed a simple PLC programme and Im trying to connect my PC and Beijer HMI via an ethernet cable and scanit in the codesys software. But when I scan it does not show any device.
Last updated: 2023-12-08

Error codesys raspberry CODESYS Forge talk (Thread)
Error codesys raspberry
Last updated: 2023-12-08

Post by theo on Error codesys raspberry CODESYS Forge talk (Post)
Bonjour a tous je souhaiterai connecter mon Raspberry a codesys en tant qu'automate cependant lorsque je enterent l'IP dans le encadré et que je fais entrer voici le message qui apparait, je suis français mais en anglais ça signifie : " vous n'êtes actuellement pas autorisé a exécuter cette action sur l'appareil. Please enter the username and password of a user account with the required access rights.
Last updated: 2023-12-08

Post by kislov on Converting UINT into bytes and converting 2Bytes into UINT CODESYS Forge talk (Post)
https://content.helpme-codesys.com/en/libs/CAA%20Memory/Current/CAA_Memory/Packing/PackBytesToWord.html + optional TO_UINT
Last updated: 2023-12-08

How to generate EtherCat xml from command line CODESYS Forge talk (Thread)
How to generate EtherCat xml from command line
Last updated: 2024-06-27

Post by soped on How to generate EtherCat xml from command line CODESYS Forge talk (Post)
Hi Under tools->customize I have added the command "Generate ethercat xml" to my project so that I can export the configuration as an xml file. I can't find a way how to run that command from CLI, is that even possible and if a script is needed I would appreciate an example ?
Last updated: 2024-06-27

Post by e71828 on how to calculate the D-term in PID? CODESYS Forge talk (Post)
D.OUT: 5000 -> 2214 ->662 -> -888; X = ACTUAL= -100; SET_POINT = 0; Error = 100; D.OUT = 5000 = 100 / 0.02; Y = 0.1*(100 + 0.04 * 5000) = 30; X = ACTUAL= -70; Error = 70; D.OUT = (30-70)/0.02 <=> -1500;???? How to explain this?
Last updated: 2024-06-27

How to generate EtherCat xml from command line CODESYS Forge talk (Thread)
How to generate EtherCat xml from command line
Last updated: 2024-06-27

how to calculate the D-term in PID? CODESYS Forge talk (Thread)
how to calculate the D-term in PID?
Last updated: 2024-06-27

Post by mikek10 on Ethernet/IP 4.6.0 causing exceptions? CODESYS Forge talk (Post)
Hi, I have a project currently in development, it has a number of Ethernet/IP devices (18 adapter devices with Codesys as scanner, another scanner device with codesys as adapter). This has been stable whilst on factory floor for several months (though prior to that I did have some Ethernet/IP issues which were resolved by adjusting RPI rates). Today I tried updating to Ethernet /IP 4.6.0 from 4.5.1, subsequent to this I had 2 exceptions in a 2 hour period, I reverted to 4.5.1 and have had no further exceptions. Note I do have a device (Zebra printer) that frequently times out and reconnects, this does not seem to cause any issues in operation and does not cause any exceptions with 4.5.1. I believe the root cause of this is on the Zebra side, however there does not seem to be any adjustment I can make to prevent the time outs. Information from device log is in screenshot attached.
Last updated: 2024-06-27

Post by soped on How to generate EtherCat xml from command line CODESYS Forge talk (Post)
Hi I'm using codesys 3.5 SP4 Under tools->customize I have added the command "Generate ethercat xml" to my project so that I can export the configuration as an xml file. I can't find a way how to run that command from CLI, is that even possible and if a script is needed I would appreciate an example ?
Last updated: 2024-06-27

OPC UA Server custom NodeID CODESYS Forge talk (Thread)
OPC UA Server custom NodeID
Last updated: 2024-06-27

Post by orbis-tertius on 3.5 P20 hangs - no response CODESYS Forge talk (Post)
Is there anybody can help me with the same problem? I have to migrate created project in ver.3.5.17.0 32BIT with runtime 4.7.0 to ver.3.5.20.0 64BIT with runtime 4.7.11.0 due to the new license. All the libraries and dependencies are updaded and there are no any errors. The first compilation and loading to the controller is being compleated well. After this being done and if I am forced to change any values or change any code in the current project, another compilation will be freezed. This problem can be solved if pressed Build/cleen or cleen all. There is another method to solve this; if project is loaded with excluded object (Alarm Configuration), repeated compilations will be done well.
Last updated: 2024-06-27

Post by climblinne on OPC UA Server custom NodeID CODESYS Forge talk (Post)
I think, I have the same issue. Do you find a solution for it?
Last updated: 2024-06-27

Post by kunz on Responsive Design Example CODESYS Forge talk (Post)
Hello everyone, I have a problem with the example project Responsive Design Example, which is available here in Codesys Forge. I wanted to try switching the visualization depending on the device type. To do this, I used a smartphone to access it. I can see via breakpoints that the Smartphone visualization is selected, but the visualization of the normal monitor still appears on the smartphone. Could there be a problem with the libraries, or why is the device not assigned the correct visualization page? I dont know how do further debuggin or troubleshooting. Here the page to the example: https://forge.codesys.com/prj/codesys-example/responsive-desi/home/Home/ Thank you very much.
Last updated: 2024-06-27

Post by nano on Profinet Controller IP-Adresse ändern CODESYS Forge talk (Post)
evtl. hilft dies. ich bin mir ausserdem sicher das nach der änderung die entsprechenden master/slave-functions reconnect machen müssen. dies evtl. manuel/programatisch angestossen https://content.helpme-codesys.com/en/CODESYS%20PROFINET/_pnio_reconfigure.html
Last updated: 2024-06-28

Profinet Controller IP-Adresse ändern CODESYS Forge talk (Thread)
Profinet Controller IP-Adresse ändern
Last updated: 2024-06-28

Post by thn-power on Codesys Communication Manger - Required information model version exists in the model repository but is not found CODESYS Forge talk (Post)
Hi, Did you manage to solve the problem? I'm experiencing the same thing using a exported nodeset from UaModeler.
Last updated: 2024-06-28

<< < 1 .. 57 58 59 60 61 .. 887 > >> (Page 59 of 887)

Showing results of 22165

Sort by relevance or date