Post by albzen on EtherCat Slaves diagnosis CODESYS Forge talk (Post)
Hello everybody, I'm working on a RunTime Plc (Codesys 3.5.16/18.20) connected to an EtherCat bus with many devices. The bus has some communication fault but I don't know how understand which is the device or the cable that has the trouble. To understand the cause of the problem I would like to read the WKC (Working counter) of the devices (0x0300...0x030C), how is explained in EtherCat documents, but it seems that the read of the counter is disabled. Attached there is an extract of the Ethercat document. Can anyone give me some advice about how and with function can I read it. Thank you in advance!
Last updated: 2024-03-29

Post by markosrod on License problem gateway CODESYS Forge talk (Post)
i have the same error with when i try to validate de license of the libraries. can you help me?
Last updated: 2024-04-02

Post by squiggleypuff on Can't Add New Version of Modbus TCP Master CODESYS Forge talk (Post)
Bumping for visibility, still unable to get Modbus working on this thing.
Last updated: 2024-04-08

Post by eschwellinger on cmDongle Raspberry Pi issue CODESYS Forge talk (Post)
use Arm64 SL or Arm SL instead of the PI package - this will work
Last updated: 2024-04-24

Post by reinier-geers on License problem gateway CODESYS Forge talk (Post)
16.4 Epis What has it to do with the manufacture? It just a licence more not. So basicly the idee of codesys sucks. 3s acts like its posible to add a license. And then it depence on the manufacturer. Why ?? Its a computer !! has nothing to do with the manufacturer. Most dont what a basic licence because they have to pay for that. 3s is the problem not the manufacture of the hardware. Its like the licence of the raspberry pi. HMI is not working. Sorry you get a refund. Why suggest that its possible wen its not !!. It cost me a lot of time. Who pays my time. Why do i have to pay for somting thats not working.
Last updated: 2024-04-26

Post by k2saki on CNC / G-Code streaming processing ( to start quickly in long G-Code File ) CODESYS Forge talk (Post)
Is it possible like G-Code streaming processing (like FANUC or SIEMENS DNC Function )? Or Does anyone know the tips for CODESYS Motion to start moving long Long G-Code File quickly? I have to wait long time after "Start" button to start moving, I have to wait finishing interpreting whole G-Code file, ( and I have to prepare huge buffer to store. ) Now, I'm working on my CNC Project using SMC_ReadNCFile2, and SMC_NcInterpreter to preprocess G-Code. I tried to set SMC_Interpolator.xExecute to true to Start while after SMC_NcInterpreter processed more 50-line of G-Code, but that not worked, I had to wait SMC_NcInterpreter processed all lines to start SMC_Interpolator. G-Code have about 2000 lines of XY of G01 (or more over.. ) of short segment that a CAM software has exploded from NURBS Curve.
Last updated: 2024-05-03

Post by corriibme on Read Serial Number of PLC CODESYS Forge talk (Post)
I have recently used this example from @Brine, and it worked. Thanks
Last updated: 2024-05-21

Post by kislov on Signature verification faited fro the following package CODESYS Forge talk (Post)
Try to use newer version of CODESYS Installer: https://store.codesys.com/de/codesys-installer.html
Last updated: 2024-06-11

Post by installwhat on C0077 on one machine but not another CODESYS Forge talk (Post)
I have a version of codesys 3.5.16 on my local machine and a vm. The local machine has loads of codesys versions and libraries installed etc. I can open the FPosCR_Example_Project_SP16_patch1 project on my vm without any errors. On the local machine I get the error C0077: unknown type IoDrvEthercatLib.ETC_CO_SdoWrite. I can, on the local machine, declare a var of type IoDrvEthercatLib.ETC_CO_SdoWrite and include it in the code without adding an extra error. The problem only seems to affect the library. This is seems more an issue with my codesys set up rather than something with festo. I would like to know the possible causes. I understand most of the library manager features but it's not clear how to find the cause. Thanks
Last updated: 2024-06-11

Post by martinlithlith on Raspberry Pi: List of available drivers / libraries CODESYS Forge talk (Post)
hi! this sounds awsome! Sorry for a perhaps stupid question; how do i find you're collection?
Last updated: 2024-06-11

Post by andrew-budaiev on Formatting Integer CODESYS Forge talk (Post)
How can I format integer so it would display 001 instead of 1? Is it possible? I couldn't find it in documentation
Last updated: 2024-06-14

Post by paro on Which Lib to use, connect to a socket with URL instead of IP address CODESYS Forge talk (Post)
hi, maybe Net Base Services https://forge.codesys.com/prj/codesys-example/nbs/home/Home/
Last updated: 2024-06-17

Post by bruno-roth on Codesys access to DICTIONARY OBJECTS of ethercat (CoE ) Servo Drive CODESYS Forge talk (Post)
You could use the FBs ETC_CO_SdoWrite and ETC_CO_SdoRead
Last updated: 2024-06-19

Post by mos89p on Codesys Soft PLC OPC UA server CODESYS Forge talk (Post)
Hi did you check the log of OPCUA expert Client?
Last updated: 2024-06-27

Post by eschwellinger on Two OneWireMaster on one Raspberry PI 5 CODESYS Forge talk (Post)
hm.. could you add the project or at least parts of it?
Last updated: 2025-10-20

Post by imdatatas on Unrecoverable SoftMotion state after switch to PreOp CODESYS Forge talk (Post)
Dear @alimans, Additionally, As far as I know since starting from Softmotion V4.18.0.0 automatic restart behaviour for an axis has been changed for this issue. See below explanation from release notes. "With CODESYS SoftMotion 4.18.0.0, the behavior of SoftMotion axes after a loss of communication to the servo drive has changed. Now, an automatic reinitialization is performed as soon as the communication is established again. Before, an explicit call to SMC3_ReinitDrive had to be performed. An example for a loss of communication is that the cable to one of the drives is unplugged." Regards, imdatatas
Last updated: 2025-10-23

Post by adam on Get/Set I/O Address Mapping of DeviceObjects in python Script CODESYS Forge talk (Post)
Found out.Its script engine bug . Update to script engine version 4.2.0.0. and problem solved
Last updated: 2025-11-17

Post by eschwellinger on Deploy LicenseServer for Linux SL CODESYS Forge talk (Post)
Hi, just use the deploytool to deploy the Timeprovider on this external device: An set the IP of you SafeControl PLC
Last updated: 2025-11-18

Post by timvh on Using a raspberry pi and NVLs to log variables outside of Codesys CODESYS Forge talk (Post)
Yes, this will work.
Last updated: 2025-11-21

Post by jbcregen on Accessing parameters from a structure or function block with the web interface CODESYS Forge talk (Post)
I have a project with hundreds of OPC-UA variables available on the network. A lot of these variables are used actively in various scripts that run in background in the OS (Linux). I'm experimenting with Automation Server and I have a hard time understanding how the web interface populates its parameters list for a given PLC (<plc details="" parameters="" for="" plc="" 'xyz'="">).</plc> In this page, it looks like the only variables available are the ones that are of a "base" type : bool, TIME, String, INT, etc. All the variables that are nested into function blocks or structures are not available in the web interface, even if they are available to any OPC-UA client. Is this a limitation of the Automation Server or is there something that can be done in Codesys?
Last updated: 2025-12-01

Post by eschwellinger on Soft Container License issue with ARM64 Linux CODESYS Forge talk (Post)
the softcontainer should be generated on first start of the plc runtime on your system
Last updated: 2025-12-10

Post by timvh on Version management CODESYS Forge talk (Post)
This depends on what you want to achieve with installing the latest version and how you manage your projects and repositories. Maybe you also want to update your device (right click on it to update) or maybe your device is depending on certain versions of libraries (go to the library manager in your project and download the missing libraries). An option is also to first create a projectarchive of the current project you have before you install a new version of CODESYS. Then you can open this projectarchive in the new CODESYS version. Especially if you install the latest version of CODESYS in a Sandbox.
Last updated: 2025-12-15

Post by eschwellinger on Access to the path *** is denied CODESYS Forge talk (Post)
will be fixed with an update/patch of the Visu (4.9.1.0) package scheduled for the 17th December - release date
Last updated: 2025-12-11

Post by fless on No source code available for profinet library CODESYS Forge talk (Post)
looks like you are running in a bug in the newest version 4.4.0 of the profinet library or the new library triggers a bug in your code. did you update your profinet device too? you could try to downgrade to an older version of the library. via library manager - placeholders, double click Profinet 4.4.0 in the library column and choose an older version.
Last updated: 2023-08-23

Post by fefefede on Error C0521 - unknow compiler CODESYS Forge talk (Post)
Hello, i'm a new user of Codesys and student of ST program for PLC. Since today for a few new projects i have two error code C0521 and i can't solve. I also just try to update device and search library but nothign resolve. How can i fix this? Thanks
Last updated: 2023-09-02