Post by mmpl on Array to String
CODESYS Forge
talk
(Post)
Hi Thank you for you reply. Yes I can concatenat longer string. I am using string_Util_Intern libraray for concat. The issue is abot plc performance. It takes 7 second. I am looking to improve time.
Last updated: 2024-07-23
Post by viktorr on IP-Change not alloed on this adapter ! PN-Device will operate with limitations.
CODESYS Forge
talk
(Post)
Hi i know this is a bit of a long shot but did you ever find a solution to this? Running into similar issues...
Last updated: 2024-07-24
Post by ibarragerman on PLCHandler where is it
CODESYS Forge
talk
(Post)
Hello, someone has some example to use PLC Handler? Without SDK. I would like to make some test before to go forward buying SDKs.
Last updated: 2024-07-26
Post by ibarragerman on PLCHandler where is it
CODESYS Forge
talk
(Post)
Hello, someone has some example to use PLC Handler? Without SDK. I would like to make some test before to go forward buying SDKs.
Last updated: 2024-07-26
Post by ibarragerman on PLCHandler where is it
CODESYS Forge
talk
(Post)
Hello, someone has some example to use PLC Handler? Without SDK. I would like to make some test before to go forward buying SDKs.
Last updated: 2024-07-26
Post by jmfernandes on OpenDir always in error
CODESYS Forge
talk
(Post)
Well I created a user as Admin, gave access rigths to the file but still can't read the files in the plc it gives the same error. I guess is something to do with plc itself.
Last updated: 2024-08-01
Post by programmierer on Implementing UDP Communication
CODESYS Forge
talk
(Post)
Hello everyone, I hope you can help me with my problem. I am new to programming and am currently working with a WAGO controller in our lab, which controls a heat pump. My goal is to send the electrical power of the heat pump (Pel_WP) via a UDP connection to a specific IP address. I am using Codesys version 2.3 and following the guide I found here: https://forge.codesys.com/forum/de/396/genmed-Konfiguration%20der%20UDP%20Kommunikation%20Cosesys%20S7.pdf. I have adapted the guide to suit my needs. The data sending works since I can force the reception value Pel_WP and the data is sent accordingly. However, I am having trouble with the receiving part. The reception value is not being correctly received, and the diSocket variable shows -1. The connection between the heat pump and the WAGO controller seems to be set up correctly, as the heat pump is listed under the communication parameters with the correct IP address. I have also attached images to provide a better view of the setup. I would greatly appreciate any support or suggestions for a solution. Thank you in advance!
Last updated: 2024-08-02
Post by mubeta on parker servo and position
CODESYS Forge
talk
(Post)
With this kind of motor nominal tourque I can belive that it can be moved very easy. 1,6 Nm is, for example, the torque required for unscrew a small loose cap from a bottle.
Last updated: 2024-08-05
Post by mubeta on parker servo and position
CODESYS Forge
talk
(Post)
In general, drives have parameter sets to adjust behaviour in such cases: position recovery, adaptation with resistant torque, out-of-position window failure, etc. (Much depends on the type of configuration set for the axis: positioner, speed controller, torque controller, etc.). I have used that type of drive very little, in only two cases and a long time ago. To tell you what is normal is impossible. I know by reputation they are very simple objects, without too many pretensions and adjustments possible. Try running traces by monitoring actual position, motor current, torque and following error. These are the most sensible curves to understand what is going on. Maybe by fine tuning the motor tuning, the current controller or the speed controller you will get something closer to what you want. For example, from DS, the motor has a standstill torque of 3 Nm. Observe with traces whether this is effective: motor current trend. And afterwards, when you have your own accurate picture of the situation, you can also hear from the product's local support to see if you can steal a few more things from it performance-wise.
Last updated: 2024-08-05
Post by pavanifm on CODESYS 3.5 Testmanager and Jenkins
CODESYS Forge
talk
(Post)
Hello All, we are also struggling with the same issue, can we start codesys test manager with CLI interface headless/ without UI? This is preventing us to do CI from git for our test automation.
Last updated: 2024-08-07
Post by installwhat on No connection to target: An existing connection was forcibly closed by the remote host
CODESYS Forge
talk
(Post)
Worked for me too. Now I have to find out why I didn't need to do this on very similar systems and what the security issue is
Last updated: 2024-08-11
Post by sturmghost on Codesys Visu Update Frame Parameters No Dialog Appears to update
CODESYS Forge
talk
(Post)
This is still a huge problem. Does someone know how to update the frame references (not manually for every frame-element...)?
Last updated: 2024-08-12
Post by andreiot40 on Step motor ECT60 Ethercat in codesys 3.5
CODESYS Forge
talk
(Post)
I want to use my step motor with driver ECT60 Ethercat on CODESYS 3.5. All connexion is good because it work with Twincat 3. But now I want to use that with CODESYS 3.5 but the communication doesn't work. someone can help me ?
Last updated: 2024-08-13
Post by dkugler on Calculate Time Between Two Events Using RTC
CODESYS Forge
talk
(Post)
a few seconds later with google search... https://stackoverflow.com/a/61986234 SYS_TIME is definitely an ABB AC500 specific function, included in library SysInt_AC500_V10.lib.
Last updated: 2024-08-14
Post by andreiot40 on Step motor ECT60 Ethercat in codesys 3.5
CODESYS Forge
talk
(Post)
Thanks for your response. for Master in log i have : no slaves found, Interface could not be opened, could not open network adapters. Status : Not running FOR ETC60 There is nothing !!!
Last updated: 2024-08-15
Post by simon001 on CAN communication settings for USB2CAN-C
CODESYS Forge
talk
(Post)
I am using the Innomaker USB2CAN-C device to communicate via CAN in the Windows version of CODESYS, but I am encountering error code 27E2, which indicates that the driver is not found. Could you please advise on how to proceed with the CODESYS settings?
Last updated: 2024-08-18
Post by ruobian on Analog Input Delay Timer
CODESYS Forge
talk
(Post)
Hello there, I am new here and in programming. I need help with the basics. I am trying to do what I mentioned in the title. I have an analog input. So I have a real or integer data type value. I want to delay it. TON and TOF only work with bool. I think there is a function block that has two inputs, 1 for real or int and 1 for bool. And if bool is true, it will give the output as real or int. I don't know but I need something like this. Actually, it is not exactly like that. In other words, it will not show the real value at the input at the output after a certain period of time. I want it to show the real value from 2 seconds ago continuously. The purpose of doing this is to compare the real value I received with the value from 2 seconds ago and find out whether it went up or down. I am using only FBD. Please help me with this. Thanks in advance.
Last updated: 2024-08-20
Post by fabriciosegalin on SMC_NCDecoder very slow to decode lines
CODESYS Forge
talk
(Post)
Does anyone know a way to load a CNC program from CNC Editor faster using SMC_NCDecoder? It takes around 7 seconds to load 34 lines of G code and this is a problem for repeating the CNC program.
Last updated: 2024-08-23
Post by hfelek on TargetVisu for Linux Package on runtime 4.12.0.0 install error due to Qt dependencies.
CODESYS Forge
talk
(Post)
I use V3.5.SP20 Patch 2 for development and my device with runtime is armv7l 32-bit arch
Last updated: 2024-08-27
Post by nicopolux on Profinet RPC-call error
CODESYS Forge
talk
(Post)
I have tested this on several PC, several Windows version and I cannot figure out why the RPC is bloqued. I have no idea how I could make it work before lol thanks all for your help
Last updated: 2024-08-28
Post by trycyclepower on How to set unit in Axis
CODESYS Forge
talk
(Post)
I am very new to Motion in Codesys. I have linear axis and would like to setup as mm, I want to move axis and control axis in mm, mm/s. How do I do that? I know my electronic gearing is 200000.
Last updated: 2024-08-29
Post by tk096 on How to set unit in Axis
CODESYS Forge
talk
(Post)
Hi, you have to define how many increments of the drive correspond to one unit in your application. This is done in the Scaling/Mapping Tab in the drive editor.
Last updated: 2024-09-02
Post by damian177 on OPC UA Client
CODESYS Forge
talk
(Post)
When I try connect by other OPC UA Client everything is ok. Look like codesys have a problem with 'Tags' group. It possible add manually measurements form 'tag' group to codesys ?
Last updated: 2024-09-03
Post by timvh on Help with DynamicTextGetTextW
CODESYS Forge
talk
(Post)
First of all you need to enable "Use unicodestrings" in the Visualization Manager. This function returns a pointer to a WSTRING (not STRING). To get this wstring value, do something like this: VAR myWstringVariable : WSTRING(255); END_VAR myWstringVariable := myResult^; // this is dereferencing the pointer to the WSTRING.
Last updated: 2024-09-03
Post by damian177 on Problem with downloading OPC UA tags by Data Source Manager
CODESYS Forge
talk
(Post)
In my OPC UA Server is about 12 thousands tags. Can by possible that downloading tags from OPC UA Server lasts a long time , and when expires about 2 hours (demo license time) that downloading freezes ?
Last updated: 2024-09-04
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND
or OR
.