Post by dmb-fan on Attemp Convert old V2.3 projects : Error HRESULT: 0x80010105 (RPC_E_SERVERFAULT)) CODESYS Forge talk (Post)
I try Sandbox. Now I get messages like "Converter is on the blacklist for this version". Online help says nothing about a too high version for the converter. How I can find out the allowed version? Or is this only for sandboxes? what a jungle !
Last updated: 2026-08-11

Post by fabian on Sys Process Execute Command CODESYS Forge talk (Post)
Hello, I have a question: Once the command is being executed, is there a way to kill it again? As the called application is running in the background, the user can't close it but it shall be closed/terminated, commanded by codesys. I have tried with "SysProcessTerminate" but I guess this is not correct as the RTE crashes when this function is called. Starting the application: IF GVL.xStrtQR THEN GVL.xStrtQR := FALSE; SysProcess.SysProcessExecuteCommand2(pszCommand:=sCmd, pszStdOut:=stdout, udiStdOutLen:= SIZEOF(stdout),pResult := ADR(GVL.pResQRTsk)); END_IF Trying to stop it again: IF GVL.xTrmQR THEN GVL.xTrmQR := FALSE; pResTerm := SysProcess.SysProcessTerminate(hProcess:=SysProcess.SysProcessGetCurrentHandle(pResult:=ADR(GVL.pResQRTsk))); END_IF Codesyscontrol Win x64, 3.5.19.10. Many thanks for any advice pointing to the correct direction.. :-) Regards, Fabian
Last updated: 2023-11-17

Post by adaml on ScriptEngine - execute "Export -> Bootproject and firmware (SD Card)" from python CODESYS Forge talk (Post)
Hi everybody, recently I was checking how many time consuming manual tasks I can perform with python scripts through ScriptEngine. I have in the project many devices and currently I export bootprojects for them by right clicking on Application, then go Export -> Bootproject and firmware (SD Card) and then point folder where files should be exported. It's fine if project has few devices, but I have some of them with over 30 devices and manual clicking like that is very time consuming. How can I do it with python script? So far I found "create_boot_application" method from Application object (taken by projects.primary.find('Application', True)) but it only generates .app and .crc file instead of full structure to store on SD card (FIRMWARE, USERDATA, SDCARD.INI, Version, Version.txt.sig). Should I use some method to control user interface? Best regards, Adam
Last updated: 2024-07-05

Post by xiaolo on Raspberry Pi 5 CODESYS Forge talk (Post)
Does Ver. 4.12 support Raspberry Pi 5? I have three issues. The first issue is that Codesys cannot detect the RPI 5 when I want to download the runtime. When assigning the IP Address manually then I can download the runtime. The second issue is that I cannot connect to the RPI to download a program. Sometimes the window pops up and it ask for the user credentials, but it is still not connecting. The third issue is that I cannot connect to an ESP32 configured as a Modbus Slave with a Raspberry Pi 4B. I can connect to the ESP32 via a Radzio! Modbus Master Simulator. I am also missing the function Write Holding Registers in the setup of the slave. Are this known issues and when it will be solved?
Last updated: 2024-07-12

Post by sigurdrb on Codesys and error messages, warnings exceptions etc. CODESYS Forge talk (Post)
Hi, I tried some different libraries (CmpApp etc.) to find some global variables that I could read out as a variable in the codesys environment. Do any one of you know which libraries are best suited for this, and how I can read it out? My goal is to send messages, warnings etc. to the system that communicates to the PLC. Currently if something goes wrong I need to see the logfiles, or go online with the controller. I think I could save a lot of time if I could read the errors from our user interface that is connected to the PLC by TCP/IP.
Last updated: 2024-11-06

Post by dsa28 on OPC UA subscriber not operational CODESYS Forge talk (Post)
Hi, Thanks for the reply. Please note that the information and links provided are related to OPC UA Client/Server. My problem was related to OPC UA Pub/Sub. In the end I have managed to establish OPC UA Pub/Sub communication between Codesys and TwinCAT systems. Keep in mind that OPC UA Pub/Sub example is not provided in the latest library version 1.1.0.0. The user needs to download the previous version to get the example. During the configuration I ended up with some doubts regarding the usage of IEC_ARRAY type in the dataset definition (see attachment). Can you please give more information on how to use this type? Many thanks.
Last updated: 2024-11-29

Post by alberto on ExportPLCopenXML is failing CODESYS Forge talk (Post)
I'm trying to export my whole project through the option ExportPLCopenXML. It seems working, but when I'm trying to import the xml I have the following error during the importation process: Object reference not set to an instance of an object. It seems a usual issue with this process that affects to the pointer to user classes inside a procedure. I receive this error for two general functions that have this pointer declarations in the VAR_INPUT section. It seems a bug into the export/import process of CodeSYS and I couldn't skip it so far. Anyone could help me? Thanks in advance.
Last updated: 2025-03-15

Post by beavel on Customizing FileOpenSave Dialog and Keypad Integration in Visualization CODESYS Forge talk (Post)
Hi all, I'm looking to adjust the visualization of the FileOpenSave dialog. Is there a library or visualization file associated with this dialog that can be extracted, customized, and re-imported into the project — similar to how the user management dialogs can be handled? Alternatively, is there a supported way to replace or override the default dialog with a custom one? Also, is it possible to configure the FileOpenSave dialog to use a custom keypad for text input? The rest of the project uses a custom keypad due to readability concerns (the default one is too small), and this inconsistency is now quite noticeable. Any guidance or workarounds would be greatly appreciated. Thanks in advance! @thk @eschwellinger @sheberle
Last updated: 2025-09-08

Post by jtebokkel on Access to the path *** is denied CODESYS Forge talk (Post)
I am also having this issue. It was working fine for the first 2ish months and is now throwing this error. I can just try and go online again a second time and it works. I'm wondering if there is an environmental variable or something that isn't set that is causing it to use an empty path as a temp directory. The empty path will be the location the app is running from which is that path C:\Program Files\CODESYS 3.5.19.50\CODESYS\Common. The permissions don't allow a normal user to write to that directory which causes the error. It also only seems to happen when there are changes or the build has been cleaned.
Last updated: 2024-02-14

Post by david24 on Map in Codesys CODESYS Forge talk (Post)
Hello everyone, I have the task of programming a map. With the help of the visualization element "Table", I have managed to accomplish this. In the Input Configuration, I activated the option: "Write Variables", so that the user can change the values in the map. To test the program, I select the Online Mode (Simulation).There I change the values in the map. When restarting the program in CODESYS, the changes in the map are no longer there. Does anyone know an approach how to save the changes in the map? Thank you for your support Best regards David
Last updated: 2024-04-02

Post by dkugler on build (F11) / generate code using a python script file CODESYS Forge talk (Post)
thank you very much! I found the generate_code methode, but struggled with the primary and active_application. With this expample I will be able to play around. If the code generation takes a minute or more I often switch to other programs and don't notify the process is finished. So now I'll get an alert and will switch back immediately. My next little project will be, to beep different if there are errors and a seperate script to do the download incl. the user management data base without stopping at the dialogs asking for onlinechange/complete download and overwriting an existing database and as goody, play a beep/sound again.
Last updated: 2024-04-11

Post by romrot on MS SQL Compact cutting off Database name? CODESYS Forge talk (Post)
I'm trying to use an fbMsSQL_compact function to read data from an SQL database. It works with some databases, but there is one database that I can't seem to get it to work on. It's set up the same as the other databases that I've tested with the only difference I see is that the name of the database is cut off in the status message. I'll get a message like "User: User logged out succesfully from database: 12345" But the whole name of the database is something like 1234567.
Last updated: 2025-08-21

Post by timvh on History of Alarms CODESYS Forge talk (Post)
It is most likely related to the existing alarm log files in the Control Win. Depending on how you start up the Control Win, you can find the files in: C:\Users\<user name="">\AppData\Roaming\CODESYS\CODESYSControlWinV3x64\<unique id="">\PlcLogic\alarms\ Or C:\Windows\System32\config\systemprofile\AppData\Roaming\CODESYS\CODESYSControlWinV3x64\<unique id="">\PlcLogic\alarms\</unique></unique></user> Delete the files in this folder, download your project again and start the application. PS, if you have an older version of CODESYS, the files are in: C:\ProgramData\CODESYS\CODESYSControlWinV3x64\<unique id="">\PlcLogic\alarms</unique>
Last updated: 2026-01-07

Post by to-ke on Errors with VisuUserManagement library CODESYS Forge talk (Post)
Hallo zusammen, hi all, ich habe den gleichen Fehler. Auf einem Raspberry Pi geht der Fehler weg, wenn ich alles bereinige und dann vollständig übersetze. Wenn das Projekt im Codesys Development System wieder neu geladen wird ist der Fehler aber wieder da. Mit eine Win V3 x64 PLC kann ich den Fehler nur unterbinden wenn ich auf der HMI das VUM_Login einbinde. Dieses brauche ich aber nicht, da ich die HMI für das User Management selbst gestaltet habe. Das funktioniert auch. I have the same error. On a Raspberry Pi the error goes away if I clean everything and then compile completely. When the project is reloaded in the Codesys Development System, the error returns. With a Win V3 x64 PLC I can only prevent the error if I integrate the VUM_Login on the HMI. But I don't need this because I designed the HMI for user management myself. That works too. Anyone have an idea to fix this problem. Many thanks
Last updated: 2024-07-09

Post by kumareasu on Code Size CODESYS Forge talk (Post)
Is this "Application Based Licence" is applicable for CODESYS Control RTE SL
Last updated: 2023-09-08

Post by eschwellinger on Correct CAN Driver for EL6751 CODESYS Forge talk (Post)
which plc Linux based or Windows plc?
Last updated: 2023-09-20

Post by eschwellinger on Webvisu NO load CODESYS Forge talk (Post)
check the plclogger for this situation
Last updated: 2023-09-21

Post by sukrit on What licenses are required for runtime on raspberry pi cm4 CODESYS Forge talk (Post)
attached is the software matrics
Last updated: 2023-10-17

Post by simotion on Axis_Ref_SM3.perfTimers CODESYS Forge talk (Post)
Yes but what exactly does each of them stand for?
Last updated: 2023-11-24

Post by kimcuong on Profinet Deivce SL CODESYS Forge talk (Post)
How to get license trial Profinet Device SL in Codesys for beckhoff
Last updated: 2024-07-05

Post by timvh on Python API for GIT extensions CODESYS Forge talk (Post)
https://content.helpme-codesys.com/en/CODESYS%20Git/_git_using_scripting.html
Last updated: 2024-08-29

Post by damian177 on Codesys Control for Linux SL CODESYS Forge talk (Post)
everything works well.
Last updated: 2024-09-08

Post by eschwellinger on codesys VLAN tagging CODESYS Forge talk (Post)
no we'll an example for it but need some time.
Last updated: 2024-09-09

Post by talhaali on Persistent / Programme change CODESYS Forge talk (Post)
Hi, did you get any solution for this.
Last updated: 2024-09-10