Post by viktorr on Shared Memory Requested Size CODESYS Forge talk (Post)
Hello Derek, I recognize this is an older post, but i was wondering if found any ways to remedy this. I am running into what i think is the same problem you had here. Thank you in advance for any information, Viktor
Last updated: 2024-07-04

Post by viktorr on IP-Change not alloed on this adapter ! PN-Device will operate with limitations. CODESYS Forge talk (Post)
Hi i know this is a bit of a long shot but did you ever find a solution to this? Running into similar issues...
Last updated: 2024-07-24

Post by jinlee on IP Camera on the Webvisu CODESYS Forge talk (Post)
Hi guys, I am experiencing the issue that browser element can't show anything other than wbm of my PLC. I am using WAGO PFC200, trying to feed IP camera into web browser element. Can anyone helps me ? Kind regards, Jin
Last updated: 2024-09-12

Post by ph0010421 on Converting each character to a string into ASCII CODESYS Forge talk (Post)
So the printer wants an ASCII conversion of the hex equivalent of ASCII characters?? They don't make it easy for us
Last updated: 2024-11-11

Post by timvh on Converting each character to a string into ASCII CODESYS Forge talk (Post)
A standard string is actually a list of bytes that represent the ASCII code for each character. The following part of code will give you the ASCII code of one of the characters in the string: byChar := sInput[i];
Last updated: 2024-11-11

Post by jeroenaero on MC_CamIn did not work properly with SMC_FreeEncoder on SoftMotion 4.17.0.0 CODESYS Forge talk (Post)
For what it is worth taking into account on version 4.18: Softmotion 4.17 doesn't work with the SMC_TRAFO_Scara2. Very small numbers come out of dA and dB. Going back to version 4.16 solves the issues.
Last updated: 2025-01-07

Post by winki on Not Possible to connect using control SL CODESYS Forge talk (Post)
Thx for your help, I just Uninstall and install again codesys. I did it as admnistrator and now it is working... I did not change anything into the target configuration. Only my codesys on my computer. Loic,
Last updated: 2025-01-10

Post by winki on Not Possible to connect using control SL CODESYS Forge talk (Post)
Thx for your help, I just Uninstall and install again codesys. I did it as admnistrator and now it is working... I did not change anything into the target configuration. Only my codesys on my computer. Loic,
Last updated: 2025-01-10

Post by dkugler on Erreur bibliothèque WagoSysKbusTerminalControl et WagoSysKbusServices pour la gestion de la carte 750-671 CODESYS Forge talk (Post)
Hi naci, because this is a english forum it increases the chance to get help a lot if you translate your questions into english before posting :-) happy coding!
Last updated: 2025-08-12

Post by lostcontrol on USB barcode scanners CODESYS Forge talk (Post)
Hi Team, Anyone had success integrating an USB scanner into a raspberryPi application.? There is notes/old links that dont work, but cannt seem to find them yet.
Last updated: 2023-12-14

Post by calviniscoding on JSON CODESYS Forge talk (Post)
Can you post the new code that you have by chance? Also, are you able to send the values of tags dynamically with the RTAC in this JSON format? I'm running into a lot of road blocks with it.
Last updated: 2024-06-21

Post by calviniscoding on JSON CODESYS Forge talk (Post)
Can you post the new code that you have by chance? Also, are you able to send the values of tags dynamically with the RTAC in this JSON format? I'm running into a lot of road blocks with it.
Last updated: 2024-06-21

Post by calviniscoding on JSON CODESYS Forge talk (Post)
Can you post the new code that you have by chance? Also, are you able to send the values of tags dynamically with the RTAC in this JSON format? I'm running into a lot of road blocks with it.
Last updated: 2024-06-21

Post by timvh on Device logon problem following fresh install CODESYS Forge talk (Post)
In your project you selected the "CODESYS Control Win V3" as device, but the device you want to connect to is a "CODESYS Control Win V3 x64". Those are not the same. If you double click on the device during the network scan, you will get information that these are not the same, but that you can change the type in your project to the x64 bit type. Another option is to "right-click" on the device in the device tree of your project and select "update device" then select the x64 type.
Last updated: 2024-03-19

Post by kurtk on SysProcess Execute Command unable to run commands with special characters CODESYS Forge talk (Post)
Thank you for this additional information. Could you please provide the references to the official documentation where you found this information ? I got as far as: Then insert this: [SysProcess] BasePriority=Realtime Command=AllowAll devoid of references of where the CodesysContol.cfg file was located or of the need to run codesys as root I incrementally located bits of information with perplexity searches but remained mired at error 25 ERR_NO_ACCESS I am curious whether root access is MANDATORY to run SysProcessExecuteCommand (- and/or any other SysProcess functions) or if a more access-constrained User=quasiroot could suffice without the security concerns ? Apparently codesys runs fine without User=root for almost everything... That raises the question: What IS the default codesys user ? I notice in the prototypes: VAR sCommand : STRING := '/usr/bin/whoami'; sOutput : STRING(255); refCommand : REFERENCE TO STRING; refOutput : REFERENCE TO STRING; resultCmd : UDINT; END_VAR whenever I attempt to build this Codesys v3.5 SP2 whines that "cannot convert type REFERENCE TO STRING to STRING" don't remember the exact message... Apparently this happens whenever a fixed-length string is involved. if I get rid of (255) and just set the string := ' '; that is sufficient to make the compiler happy. Is this a recently enforced constraint ? Why does this compile for you and not for me ? There are references to functions / utilities which are used/needed to massage the string references - but I see no specific details... I also notice you specify: Make sure the lib SysProcessImplementation, SysTypes, and CmpErrors is on the project. I don't comprehend why all of the dependent libraries are not automatically referenced, added ? I don't recall seeing anywhere but here that SysProcessImplementation must be included... It just seems odd that the default is to exclude essential libraries, or require alchemical conjuring to assemble all the ingredients for gnat soup ;-) Thanks a lot... I'm still a codesys newby getting my wheels on - or sometimes just partially on
Last updated: 2025-09-12

Post by micik on Changed Device of Rapberry Pi to MC SL instead of standard SL and cannot connect anymore CODESYS Forge talk (Post)
I have a test application and use Codesys Control for Rasp Pi SL. I made a mistake and updated device from MSL to MC SL, and now if I try to go online with archived version of the project I gett error message that IDs are different between project device and target device. Of course, I can go online if I changed device in the project from SL to MC SL, but I'm not sure that is correct. So I have two questions: 1. What is the actual difference between MC SL device and standard SL device when it comes to raspberry pi 4? 2. What change I need to do on raspberry pi4 side to change device back from MC SL to SL? Thank you!
Last updated: 2025-08-05

Post by sturmghost on Initialization of visualization variables and cyclic code execution CODESYS Forge talk (Post)
I'm looking for a smart and short way to implement initialization of visualization variables depending on the visualization input. For an easy example consider a rectangle which rests at XPos := 0 when the input state is false and at XPos := 50 when the input state is true. My visualization variables look like this: VAR_IN_OUT State : BOOL; END_VAR VAR XPos : INT; END_VAR I put this rectangle via a visualization frame element into another visualization and link a frame reference variable with the state to it. If the variable is true, the rectangle should rest at XPos := 50 and false at XPos := 0 at visualization init but how should I assign the 50 or 0 to the internal visualization variable XPos? I would need some init-methode for the visualization but I dont want a global init-method for such tasks. I want to do it inside of the visualization element but I can't see any solution for this? It would be good to be able to define ST-code within the visualization element which runs cyclic at each VISU_TASK task-cycle then I could just check the input state and change the XPos accordingly. Does someone have a solution?
Last updated: 2023-10-01

Post by talhaali on Adding a variable from text list into ST code CODESYS Forge talk (Post)
Hi, can I use a entry of a text list as variable in structured text? for example in attach picture, if i use want to use data of first row. I am trying to write: A : STRING := TextList.Default.0; but it is not workings
Last updated: 2023-12-07

Post by talhaali on Adding a variable from text list into ST code CODESYS Forge talk (Post)
Hi, can I use a entry of a text list as variable in structured text? for example in attach picture, if i want to use data of first row. I am trying to write: A : STRING := TextList.Default.0; but it is not workings
Last updated: 2023-12-07

Post by maxkemmeren on PFC200 (750-8214) high linux load average, but seems random. Possibly EtherCAT related. CODESYS Forge talk (Post)
Have you received any feedback or found any solutions to the load problem. We are running into similar issues, even without codesys running the load avarage is above 1 meaning that it is to busy already without plc code running. Hope you might have some more insight.
Last updated: 2024-07-11

Post by tk096 on Some 'pathetic' errors in SoftMotion program CODESYS Forge talk (Post)
Hi, I suppose that you are referring to the error code "SMC_FB_WASNT_CALLED_DURING_MOTION"? Starting of Softmotion version 4.15.0.0 the instance path of the function block that has not been called is logged into the device log. This might help you to identify why it has not been called.
Last updated: 2024-07-18

Post by timvh on Converting each character to a string into ASCII CODESYS Forge talk (Post)
Nice puzzle for a Saturday afternoon :-). Here my suggestion: VAR sInput : STRING := 'R123'; byChar : BYTE; sOutput : STRING; i: INT; END_VAR sOutput := ''; IF LEN(sInput) = 0 THEN RETURN; END_IF FOR i := 0 TO LEN(sInput) - 1 DO byChar := sInput[i]; sOutput := Concat(sOutput, TO_STRING(byChar)); END_FOR
Last updated: 2024-11-09

Post by laurits on Max lines of code, codesys CNC ? CODESYS Forge talk (Post)
Testing Codesys CNC. SMC Interpolator Throws me an error if my code surpass approximately 32000 lines of code. (SMC_CNC_INTERNAL_ERROR) What is the max lines of code SMC Interpoltor can handle ? I've been thinking breaking the code up into smaller sections, but that gives me a lot problems later if i want to use "Blocksearch" etc. I need to run approximately 2000000 lines of code.
Last updated: 2025-06-01

Post by bjarne-pagaard on Multiple WebVisu CODESYS Forge talk (Post)
You can use the switch frame variable, but there should be a variable for each active visu user. You can put the switch frame variable in an array, and use CURRENTCLIENTID as index into the array to get what you want. The CURRENTCLIENTID is assigned to new users automagically by the Visu Management.
Last updated: 2024-03-14

Post by rossanoparis on How to configure CODESYSControl_User.cfg in order to use a specific network card for OPCUA Server CODESYS Forge talk (Post)
Hello at all I'd like to know how to configure CODESYSControl_User.cfg in order to use a specific network card for OPCUA Server. In the past, I tried to ask in "Forge" about this topic, but I could find neither help nor document informations about it. Reading the file "codesyscontrol.log" I see these logs OPC UA Server Started: Hostname: NTLRPICTRL01, Port: 4840 URL: opc.tcp://NTLRPICTRL01:4840 Loopbackadapter activated. **All available networkadapters are used.** Multithreading activated. 3 workers used. My controller, which is a Linux PC, has got two network cards eth0 and eth1 I whant to use the card with name "eth0" as a server for OPCUA and keep the "eth1" free for other stuffs. Is it possible ? Best regards Rossano
Last updated: 2023-08-25