Post by eschwellinger on Unrecoverable SoftMotion state after switch to PreOp
CODESYS Forge
talk
(Post)
i would recommend to check the plc log..
Last updated: 2025-10-23
Unrecoverable SoftMotion state after switch to PreOp
CODESYS Forge
talk
(Thread)
Unrecoverable SoftMotion state after switch to PreOp
Last updated: 2025-10-23
How to stay in a method until something is finished.
CODESYS Forge
talk
(Thread)
How to stay in a method until something is finished.
Last updated: 2025-11-04
Codesys v 3.5 to factory IO
CODESYS Forge
talk
(Thread)
Codesys v 3.5 to factory IO
Last updated: 2025-11-20
Post by youness on CSVReaderInit returns error : INVALID_HANDLE
CODESYS Forge
talk
(Post)
I have Already the same problem when i'm trying to write data more than 10 times in the same file. In fact, i send my data periodicaly to a file that i configured to have permission of W/R in my CodesysContol.cfg. When the Error occurs, i must reboot my machine to success. It means that the problem isn't realted to a limitation of size, but a problem in the function supposed to handle the file. totorovic : allow me to know if you've found a solution to your problem. Thanks.
Last updated: 2025-11-26
How to use MQTT in CODESYS Control Win V3
CODESYS Forge
talk
(Thread)
How to use MQTT in CODESYS Control Win V3
Last updated: 2025-12-12
Unable to deploy "Control for Linux SL 4.18.0.0"
CODESYS Forge
talk
(Thread)
Unable to deploy "Control for Linux SL 4.18.0.0"
Last updated: 2025-12-19
Upgraded Raspberry 2b to Raspberry 5, Trends Broken?
CODESYS Forge
talk
(Thread)
Upgraded Raspberry 2b to Raspberry 5, Trends Broken?
Last updated: 2025-11-13
How to read effective version of libraries?
CODESYS Forge
talk
(Thread)
How to read effective version of libraries?
Last updated: 2025-12-11
Post by mondinmr on Frustration-Fueled Feedback on Project File Management and Git Integration
CODESYS Forge
talk
(Post)
Good day, I’m writing this message out of frustration regarding the current way project files are saved as encrypted XML and single-file format in CODESYS. I find this approach to be quite tedious for several reasons: Limited Access to Structured Text: Not being able to access Structured Text (ST) externally makes it impossible to work with alternative editors like VSCode. Tools like VSCode are incredibly responsive and feature advanced systems such as GitHub Copilot, which would be a real game-changer when working with ST IEC. While CODESYS works well for small code snippets or debugging, when the codebase grows, switching to VSCode to boost productivity becomes essential, and copy-pasting between environments is a cumbersome workaround. Poor Integration with Git: This file format also makes it very difficult to integrate effectively with Git. I have tested the internal demo, but for advanced merges, it is unusable. Without properly formatted plain text, it’s impossible to leverage the vast ecosystem of external tools around Git that allow smooth merges in heterogeneous teams. File Corruption on Network Drives: I often work from multiple locations with shared network drives. When the development environment saves a file and something goes wrong midway (which can occasionally happen when using VPNs and network drives), the entire project becomes irrecoverable. There’s no way to cancel the save process, and the development environment freezes. This has happened to me at least four times over the past two weeks, and one of those incidents cost me an entire day of work. All of this is particularly disappointing because I truly believe that the libraries, runtime, and overall work done by CODESYS are exceptional. I find it fantastic that there is a platform allowing development of PLCs and control systems using OOP, which is a huge advantage in modern control engineering. I apologize for the rant, but this issue has been extremely frustrating. Best regards.
Last updated: 2024-10-15
Post by bruceae on Ethernet/IP Scan
CODESYS Forge
talk
(Post)
Hello, I have a robot configured as a Generic Ethernet Module under Ethernet/IP Scanner. I can not see the change of state of the outputs coming from the robot on the codesys side in real-time. (The robot has it's own internal program that would changes the values of remote outputs 0-3 off and on). Also when I send data down to the inputs of the robot it doesn't transfer over as expected. As an example I'll send to the robot's input bit 0 a value of 1. It doesn't see that value change. However, when I write that input bit 0 back to a value of 0, the robot changes state and shows a value of 1. And if I change the state of a different bit, the other bits update properly, except for the bit that I changed. Any advice would be greatly appreciated, and if anything else is needed let me know.
Last updated: 2024-09-10
Post by ojz0r on Assignment Efficiency - Repetitive Assignment vs IF statement
CODESYS Forge
talk
(Post)
Its important that you know the difference between the two. Example 1: Coils[0] := Coils[0] OR (Buttons[0] AND Sensors[0] > 6); In this case the statements will be evaluated every scan and result in either true or false for Coils[0]. Example 2: IF NOT Coils[0] AND Buttons[0] AND (Sensors[0] > 6) THEN Coils[0] := TRUE; END_IF In this example Coils[0] will latch the result in a true evaluation, if you want it to behave the same way as example 1 then you need to do it like example 3 below: IF NOT Coils[0] AND Buttons[0] AND (Sensors[0] > 6) THEN Coils[0] := TRUE; ELSE Coils[0] := FALSE; END_IF However back to the real question. There is no problem using either example 1 or example 3, if im not requiring a latch i usually go with example 1 as it is more compact.
Last updated: 2025-03-07
Post by jonasz on Deploy LicenseServer for Linux SL
CODESYS Forge
talk
(Post)
Good morning, I'm digging into this topic because I'm curious about resolving my problem in a test environment. In my previous message, I asked about the CODESYS Safe Timeprovider SL package (4.18.0.0), which I saw in the illustration. I noticed that it runs as a service. I am asking about this because from the perspective of an "ordinary" user, this service provides easier access to the settings of the time provider's operating parameters. The basic time provider configuration is outlined at https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_virtual_safe_time_provider.html. Why my questions? They stem from my specific case, which is experiencing timeout issues. I know that my environment is currently only a test environment. I'm assuming a real-world scenario in which I won't be able to achieve a better result with my configuration, and I will ultimately need to increase the time provider's cycle time. By running the time provider service, I can easily influence the time provider's operation and thus eliminate the problem. I know, I know, safety systems are not life-enhancing extras.
Last updated: 2025-11-19
Post by rshabsh on Using Latch Variable in Alarm as input from text list
CODESYS Forge
talk
(Post)
I am currently utilizing Alarm Manager’s Latch Variable 1 to display additional information related to alarms. However, instead of mapping this latch variable to a fixed PLC variable, I would like to dynamically update its text content based on the selected language in the system. To achieve this, I am considering using a text list that corresponds to different languages rather than directly linking Latch Variable 1 to a PLC variable. This approach would allow the displayed alarm information to be automatically translated according to the active language setting. Could you please confirm if this method is feasible within the Alarm Manager configuration? Additionally, if there are specific steps or best practices to follow when implementing this functionality, I would appreciate any guidance you can provide. Looking forward to your insights.
Last updated: 2025-02-26
Post by mondinmr on Direct Pointers in IOMapping for EtherCAT with IoDrvEthercatLib.ETCSlave_Dia
CODESYS Forge
talk
(Post)
Using SDO, I can read the EtherCAT mappings and offsets from various registers like 0x1c12, 0x1c13, etc. When I obtain registers mapped in the PDOs and various offsets, I could technically access directly to the statusword, controlword, etc., if they are mapped. I have noticed that on IoDrvEthercatLib.ETCSlave_Diag I can find pointers to the input and output buffers. However, although the input buffer can be easily read by referring to what has been obtained from the SDOs, it is not possible to write to the output buffer, as it is overwritten in each cycle by the data from the IOMapping task. Is there a way, knowing an instance of IoDrvEthercatLib.ETCSlave_Diag, to obtain the pointer to the first data in the IOMapping? The offsets are identical to those of the PDOs, but obviously the data is a copy. For me, the cleanest thing would be to access the pointers on IOMapping, for DS402a devices to retrieve the key data and point them to internal references. I need to know this as, having developed our own motion library, I would like to simplify the initial setup by eliminating unnecessary and nonsensical mappings that can lead users to unnecessary errors. In the current version that we have been using for years, we have to map everything manually. I would like to pass only the slave reference to the FB_init constructors and eliminate the mapping.
Last updated: 2024-02-12
Upgrading CODESYS runtime from v4.7 to v4.9 using a bash script leads to lose the licences stored in the soft container
CODESYS Forge
talk
(Thread)
Upgrading CODESYS runtime from v4.7 to v4.9 using a bash script leads to lose the licences stored in the soft container
Last updated: 2023-09-19
Post by nathant on Saving variable values on power cycle (RevPi Connect)
CODESYS Forge
talk
(Post)
Hello, this seems to be a known issue, but persistent/retain variables don't seem to work properly on RevPi devices. Is there a workaround to this? All I need is for a few configuration variables to be remembered through power cycle.
Last updated: 2023-12-03
Post by mos89p on is it possible to connect to a newer runtime from HMI runtime 3.5.16
CODESYS Forge
talk
(Post)
is it possible to connect to a newer runtime from HMI runtime 3.5.16 via Datasource manager for example a 3.5.20 ?
Last updated: 2024-07-02
Post by trycyclepower on How to set unit in Axis
CODESYS Forge
talk
(Post)
I am very new to Motion in Codesys. I have linear axis and would like to setup as mm, I want to move axis and control axis in mm, mm/s. How do I do that? I know my electronic gearing is 200000.
Last updated: 2024-08-29
Post by damian177 on OPC UA Client
CODESYS Forge
talk
(Post)
The OPC UA Client Example with webvisu is working. Now I would like to use Datasource to connect to OPC UA Server but some is wrong because nothing to do when I try list tags from server - please find in attachement
Last updated: 2024-09-03
Post by timvh on Help with DynamicTextGetTextW
CODESYS Forge
talk
(Post)
First of all you need to enable "Use unicodestrings" in the Visualization Manager. This function returns a pointer to a WSTRING (not STRING). To get this wstring value, do something like this: VAR myWstringVariable : WSTRING(255); END_VAR myWstringVariable := myResult^; // this is dereferencing the pointer to the WSTRING.
Last updated: 2024-09-03
Post by timvh on CoDeSys 3.5 SP20 "No Offline Help installed"
CODESYS Forge
talk
(Post)
Open the CODESYS Installer (from the menu Tools). Go to Browse. Search for: help ... Select the CODESYS Offline Help which you would like to install. (probably you have to close CODESYS to install it and reopen it after installation).
Last updated: 2024-10-01
Trying to pull Logged In user details and certain other variable values and in turn log to a database
CODESYS Forge
talk
(Thread)
Trying to pull Logged In user details and certain other variable values and in turn log to a database
Last updated: 2024-11-07
Post by xlfll on How to use libdoc to implement libraries in multiple languages
CODESYS Forge
talk
(Post)
po file to generate translation file mo, how to mo file into lmd file into the compilation library? This is not clearly described in the codesys help. Does anyone know? codesys help:https://content.helpme-codesys.com/en/LibDevSummary/localization.html#deployment-of-translated-documents
Last updated: 2025-03-13
Post by peterkcontrols on Codesys Network driver install for Codesys Control RTE x64
CODESYS Forge
talk
(Post)
Resolved this. There is a config file called CodesysControl_User that I had to edit to set the driver to component 5. I deleted the semi colon next to Component.5=CmpEt1000Drv
Last updated: 2025-03-19