Post by pernockham on Preferred way of managing Ip-adress/es for linux (debian) host? CODESYS Forge talk (Post)
I have a debian linux host running Control SL. I tried to manage IP-addresses through codesys/Control SL but that was not successful. What works though is manually editing the network-interfaces config file. /etc/network/interfaces. Is there a way to set this up so that IP-addresses can be managed from within codesys instead? Thanks! / Per
Last updated: 2025-01-22

Post by s1ack on Wago PFC200 Ethernet / IoDrvEthernet Issue? CODESYS Forge talk (Post)
I changed the interfaces to br0 & br1 as they are designated on the Wago PFC200. That issue is resoved. However, on site I have very high system cpu usage, system as in Linux. Presently it is not known why - my bench system does not exhibit such high system usage. In the past this was due to IGMP network traffic every 250uSec from synchronized inverters.
Last updated: 2025-01-22

Post by mubeta on UNION statement is not supported in the ethercat data exchange CODESYS Forge talk (Post)
Hi all, I am using a unionn statement for merge in integer data type some values that are received in byte from the i/o cards, but, using this simple and light technique, is not recognized by the ethercat data exchange and in fact the tags are not updated. In my opinion it's a very big bug.
Last updated: 2025-02-05

Post by jkopicz on How can you get the active frame index from a frame CODESYS Forge talk (Post)
In my project, I have frames that I would like to read the current active index. I change the frame index using the onclick properties of a button, then change frame index. I need to do some logic based on which frame index is selected. Is there a way to read the current active index of a frame?
Last updated: 2025-03-11

Post by timvh on library is not available CODESYS Forge talk (Post)
1) In the library manager of your project select "Download missing libraries". 2) In the library manager open the "Placeholders" dialog. In here find the Placeholder which is not referenced to a specific library yet. Click in this line on the Library column and select the latest version of this library.
Last updated: 2025-03-24

Post by sking on ModbusTCP/slave CODESYS Forge talk (Post)
i can not find the solution, i have 2 modbus tcp slave and i want to know how to do when one is activated the other one is desactivated. that means when i run the project, with a bouton click on my web visu i can choose wich modbus slave i want to activate. can someone have a solution plz ? thank you :)
Last updated: 2025-04-01

Post by eaglealex on Length of string and Array of bytes CODESYS Forge talk (Post)
Thank you for your answer! I know that 0 will be the end of the string. I checked it. There is no 0 in array of bytes. I made screenshots. There is array of bytes, aborted string and the result of my test via online converter.
Last updated: 2025-04-02

Post by snguyen on Atomic and Shared memory? CODESYS Forge talk (Post)
Hi, I've read that you can perform Atomic instructions like AtomicReadLInt on variables. However, I'd like to know if this uses stdatomic internally. My main question is : Is it possible to share atomic types in shared memory with CodeSys. If so, what types should they be declared as? If not, are the atomic functions lock-free or does it use a mutex?
Last updated: 2025-04-15

Post by andrej on Creating, using an external Function. CODESYS Forge talk (Post)
Hello, many thanks for your reply. I checked the logs. It seems that dll is not loaded. However other dll such as the Webserver are loaded. Could you tell me what I need to do such that my dll is loaded. (Furthermore I changed the C-Function a bit. I used the M4.exe from the SDK.) Many thanks.
Last updated: 2025-04-23

Post by atone on Change IO-Link Device Interface connected to a Profinet-Slave at Runtime CODESYS Forge talk (Post)
OK, I figured out that I can simply define all the sensors as 16 bytes IN/OUT, even if they are not all used. EDIT: The negative effect is that each bit is taken into account as an I/O for the license, even if not used.
Last updated: 2025-04-28

Post by andrej on Creating, using an external Function. CODESYS Forge talk (Post)
One step closer Hello finally the SoftPlc starts to load the dll on start up, however it is not successfull. I create a new minimal example Lib_XMATH.dll. Could please give me a hint, why the dll is not succesully loaded yet. Inputs would be highly appreciated. Many thanks.
Last updated: 2025-04-30

Post by fionexyan on Codesys Installation Always Freeze when the installing is almost done CODESYS Forge talk (Post)
Hello Everyone , I have try in repeatedly with uninstall and reinstall the Codesys software and even turn-off the antivirus application before implement to reinstall the codesys ,but at the consequence the problem still same although go with such method, therefore is there any solution for this issue . Thank You .
Last updated: 2025-05-16

Post by wbj0t on one variable signed to modbus tcp server device and modbus serial device CODESYS Forge talk (Post)
Hi. Raspberry pi 4 runtime. Runtime version 4.16, IDE version 3.5.21. Is it possible write new value for variable via modbus tcp or serial devices when both enabled? As I see - not. What can I do? It is terrible restriction.
Last updated: 2025-07-17

Post by aufwindsh on Visualization Scaling the Keypad CODESYS Forge talk (Post)
Hello everyone, is there an option to change the Scaling of the Keypad? I have an 15inch HMI with a resolution of 1920x1080p and the Keypad for the Login of the usermanagement is still to smals to have a great user Experiance. I really appriciate any feedback. Thanks.
Last updated: 2025-08-02

Post by ulvis on Where to find the OPC-UA Information Model Repository CODESYS Forge talk (Post)
Now, for CODESYS v3.5 SP21 I can no longer find the "OPC UA Information Model Repository" entry to add as a command. In the "Tools" menu it is listed but greyed out, reporting "Plug-in is not available". So how do I add the Plug-in?
Last updated: 2025-08-14

Post by wagokurt on TargetVisu option missing in IDE CODESYS Forge talk (Post)
I have installed both the Codesys Control for Linux SL 4.16.0.0 and Target Visu for Linux 4.16.0.0 packages in Codesys 3.5 SP21 Patch2. When I try to add a target visu, it is missing. I have spent hours on this and tried different machines, all behave the same way. Is this a bug?
Last updated: 2025-08-21

Post by jcarter on Webvisu Combined Authentication CODESYS Forge talk (Post)
Is there a way to have both a Public No Login Screens with Screens that do require login and File Transfer? My Idea is to have the default page be View Only with a Login Button in the Corner and then Once Logged In you can change settings and download files depending on your user group.
Last updated: 2025-08-28

Post by timvh on CoDeSys v3.5: creating libraries for both 32-bit and 64-bit controllers CODESYS Forge talk (Post)
Yes, you are right. I think the help is pretty clear: https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_library_development.html It helps you to find errors in the source code of your library if you want to create a library which is using pointers and you want to use your library on 32 and/or 64 bit platforms.
Last updated: 2025-09-02

Post by gseidel on can not new a cam table in codesys V3.5 SP20 CODESYS Forge talk (Post)
Hi liai, is it possible, that SM3_Basic is missing in the library manager? (It should be inserted automatically when adding a Cam table, along with the other motion libs.) You can add it manually and see if that solves the compile errors. Best regards, Georg
Last updated: 2025-09-19

Post by jy77812 on Visualization XY Charter Question CODESYS Forge talk (Post)
Hello. I'm using Visualization XY Chart, and when I mark a circle through XY position data, a blue line is displayed in the circle with a red circle. At this time, can't I set the blue line not to be seen in the circle? Currently, whenever XY position is drawn, the line follows.
Last updated: 2025-10-02

Post by dogulas on numeric text box control CODESYS Forge talk (Post)
Ok, this is how I made a numeric text field: use a Text Field properties -> Texts -> Text := %f (or %d or whatever you need) properties -> Text variables -> Text variable := (your numeric variable) properties -> Input configuration -> OnMouseDown -> Configure: Write Variable Input type := VisuDialogs.Numpad Use another variable (your numeric variable) Min val Max val etc. Please tell me there is an easier way to do this.
Last updated: 2025-10-02

Post by arwie on Possibility to deactivate CmpBlkDrvUdp CODESYS Forge talk (Post)
Is it possible to completely deactivate CmpBlkDrvUdp? I managed to practically deactivate it by setting MaxRouters=1 in [CmpRouter], but in the log there are warnings: !!!! No router instance found to assign network interface <interface>ether 6</interface> [CmpRouter] MaxRouters=1 0.MainNet=BlkDrvTcp [CmpBlkDrvTcp] Name=BlkDrvTcp Codesys Runtime 4.10.0.0 Is there a setting in [CmpBlkDrvUdp] which would deactivate it?
Last updated: 2023-12-12

Post by nz-dave on Bool turning on in case stament in wrong state? CODESYS Forge talk (Post)
pretty sure its not. ive done a cross reference and only have one write that sets it to true. Only way i can stop it is to remove the function block call from the main pou that is running said case. its got me stumped:/
Last updated: 2023-12-16

Post by ph0010421 on TCP/IP client CODESYS Forge talk (Post)
Hello TCIS_Send needs to be longer than 4 bytes because idata is 28 bytes long. There may be other ways, but I would make a UNION with string/array of bytes. Write your STRING into the AsString part then copy the AsBytes part into TCIS_Send (Elements [3] to [30]) then 252 would be in [31] (I've assumed the idata is always the same length)
Last updated: 2023-12-19

Post by kevin123 on MessageKey for missing library dialog CODESYS Forge talk (Post)
Hi Martin, I got the messagekey of the "upgrade format warning dialog" with key:"<< No Key>>". (please refer to the attachment) Is that means i can't use system.prompt_answers["<<No Key>>"] = PromptResult.OK; to auto-answer 'OK' in this dialog? Is there any other way to auto-answer this dialog? Thanks!
Last updated: 2024-01-26