Deploy Codesys Control SL to a 'secure' device
CODESYS Forge
talk
(Thread)
Deploy Codesys Control SL to a 'secure' device
Last updated: 2026-05-01
Post by gmau on RS232 Communication in CODESYS Control RTE V3
CODESYS Forge
talk
(Post)
Hello, I would like to implement RS232 communication into CODESYS Control RTE V3. I was writing the program testing it on CODESYS Control Win V3, where it worked fine. When I changed it to RTE, the communication was on, but I cannot send the data between PLC and scale - there is no or little response from scale - mostly one time receive and that is it. On Win V3 it was working fine. I read that I am supposed to configure CODESYSControl file for a proper communication using RTE, but even after that I can not get a stable and working communication. I am attaching my CODESYSControl and CODESYSControlUser data below, as well as I am sending the code from communication function. The communication should be through COM1 port of PC. CODESYS Version: CODESYS V3.5 SP21 + (64-bit) Runtime + Version: CODESYS Control RTE V3 Version 3.5.21.0 / CODESYS Gateway V3 - x64 Version 2.5.21.0 I would be much gratefull for any help. Sincerely,
Last updated: 2025-07-16
Post by vipul on Multicast udp
CODESYS Forge
talk
(Post)
Hi, Good afternoon can anybody help me with UDP Multicast code. I am not able to send or recieve data when code is dumped on linux device. Below is my code. Declaration: PROGRAM udp_multicast VAR oneTimeFlag :UINT :=0; state: INT:=0; driver: UDP.UDPDriver; //port : UDP.Port;//moved to GVL src_ipAddr_ud: UDINT; src_ipAddr_st:STRING := '192.168.127.155';//'192.168.1.155';//ipms ip address dst_ipAddr_ud:UDINT; group_ipAddr_st:STRING := '239.1.5.10'; //group_ipAddr_ud:UDINT; result: SysTypes.RTS_IEC_RESULT; //result of recieve function. bind: UDINT; //result of binding. resultCreate:SysTypes.RTS_IEC_RESULT;//result of port creation. timer:BLINK; temFlag :INT:= 0; post:INT :=0; checksumFunc:checksumXor; localStringBuf:STRING[500]; chksum:BYTE; dataBuffer:POINTER TO BYTE; checksumString:ARRAY[0..5] OF BYTE; recvSize:__XINT; errorCode:UDINT; joinGroupErrorCode:UDINT; END_VAR ************8 Implementation: IF oneTimeFlag <> 1 THEN oneTimeFlag:=1; resultCreate := driver.CreatePort(ADR(GVL.port)); src_ipAddr_ud := UDP.IPSTRING_TO_UDINT(sIPAddress:= src_ipAddr_st); GVL.group_ipAddr_ud := UDP.IPSTRING_TO_UDINT(sIpAddress:= group_ipAddr_st); GVL.port.IPAddress := src_ipAddr_ud; GVl.port.ReceivePort:= GVL.src_port;//port on which messages are expected. GVl.port.SendPort := GVL.dest_port; GVl.port.OperatingSystem := 0; //0- any system GVL.port.Socket :=3; //3- socket type is multicast bind := GVL.port.Bind(udiIPAddress:=src_ipAddr_ud,); GVl.port.JoinGroup(udiGroupAddress:= GVL.group_ipAddr_ud,udiInterfaceAddress:= src_ipAddr_ud,eLogCode=>joinGroupErrorCode); END_IF timer(ENABLE:=TRUE,TIMELOW:=T#100MS,TIMEHIGH:=T#100MS); IF timer.OUT = TRUE THEN GVL.port.Send(udiIPTo:=GVL.group_ipAddr_ud,GVL.dest_port,pbyData:=ADR(GVL.writeData),diDataSize:=SIZEOF(GVL.writeData)); ELSE SysMemSet(ADR(GVL.readData[0]),0,SIZEOF(GVL.readData)); result := GVl.port.Receive(ADR(GVL.readData),diDataSize:=SIZEOF(GVL.readData),udiIPFrom=>dst_ipAddr_ud,diRecvSize=>recvSize,eLogCode=>errorCode); SysMemMove(ADR(GVL.readDataBuf[0]),ADR(GVL.readData[0]),SIZEOF(GVL.readData)); END_IF post:=LEN(GVL.readDataBuf);
Last updated: 2024-01-14
Post by thewizard8 on Raspberry PI4 Serial Port
CODESYS Forge
talk
(Post)
Hi Dear All, I'm using my raspberry PI4 as a CoDeSyS PLC (Build from scratch with custom electronics). I was able to implement all fieldbuses with the exception of Modbus Serial. I'm using the internal Port (GPIO) and I configured it in /etc/Codesyscontrol_user.cfg the following away: [SysCom] Linux.Devicefile.1=/dev/ttyUSB0 Linux.Devicefile.2=/dev/ttyS0 I'm using COM2 on Master configuration. I'm using a interface board from TTL/RS485 (bidirectional board), and it's works perfectly with other devices but not in CoDeSyS. I'm able to send data with python script and read it on my pc using putty, but when I use a modbus slave simulator to interface with codesys I always get red icons on master and slave. (Please find image attached). I'm pretty shure that this might be a bad parameter on my CoDeSyS runtime configurstion file. Can someone help me? I'm stuck and this is for my master degree certification.
Last updated: 2024-03-18
Post by baott569 on CODESYS OPC UA Security: HMI Client Not Receiving Server Certificate
CODESYS Forge
talk
(Post)
Hello everyone, I am currently using OPC UA in CODESYS with the security mode BASIC256SHA256 β Signed and Encrypted. The OPC UA Server is running on an RTE CX device, and the HMI is running on another computer. I have reviewed many CODESYS documents and successfully established communication when the security mode is set to None with Anonymous login. However, when security is enabled, the server does not provide its certificate for the CODESYS HMI client to trust. Interestingly, the client can send its certificate to the server, and UAExpert works normally, but the CODESYS HMI client does not receive the server certificate. Can anyone help clarify what I might be missing? I have been stuck on this issue for three days. If I missed or misconfigured any step, please let me know. I believe I am stuck at step 15 in the following CODESYS guide: Encrypting the Communication of a Data Source OPC UA Client https://content.helpme-codesys.com/en/CODESYS%20Communication/_cds_encrypt_communication_data_sources_opc_ua_client.html Thank you very much.
Last updated: 2026-01-06
Post by baott569 on CODESYS OPC UA Security: HMI Client Not Receiving Server Certificate
CODESYS Forge
talk
(Post)
Hello everyone, I am currently using OPC UA in CODESYS with the security mode BASIC256SHA256 β Signed and Encrypted. The OPC UA Server is running on an RTE CX device, and the HMI is running on another computer. I have reviewed many CODESYS documents and successfully established communication when the security mode is set to None with Anonymous login. However, when security is enabled, the server does not provide its certificate for the CODESYS HMI client to trust. Interestingly, the client can send its certificate to the server, and UAExpert works normally, but the CODESYS HMI client does not receive the server certificate. Can anyone help clarify what I might be missing? I have been stuck on this issue for three days. If I missed or misconfigured any step, please let me know. I believe I am stuck at step 15 in the following CODESYS guide: Encrypting the Communication of a Data Source OPC UA Client https://content.helpme-codesys.com/en/CODESYS%20Communication/_cds_encrypt_communication_data_sources_opc_ua_client.html Thank you very much.
Last updated: 2026-01-06
Post by rshabsh on Using Latch Variable in Alarm as input from text list
CODESYS Forge
talk
(Post)
I am currently utilizing Alarm Managerβs Latch Variable 1 to display additional information related to alarms. However, instead of mapping this latch variable to a fixed PLC variable, I would like to dynamically update its text content based on the selected language in the system. To achieve this, I am considering using a text list that corresponds to different languages rather than directly linking Latch Variable 1 to a PLC variable. This approach would allow the displayed alarm information to be automatically translated according to the active language setting. Could you please confirm if this method is feasible within the Alarm Manager configuration? Additionally, if there are specific steps or best practices to follow when implementing this functionality, I would appreciate any guidance you can provide. Looking forward to your insights.
Last updated: 2025-02-26
Post by mondinmr on Direct Pointers in IOMapping for EtherCAT with IoDrvEthercatLib.ETCSlave_Dia
CODESYS Forge
talk
(Post)
Using SDO, I can read the EtherCAT mappings and offsets from various registers like 0x1c12, 0x1c13, etc. When I obtain registers mapped in the PDOs and various offsets, I could technically access directly to the statusword, controlword, etc., if they are mapped. I have noticed that on IoDrvEthercatLib.ETCSlave_Diag I can find pointers to the input and output buffers. However, although the input buffer can be easily read by referring to what has been obtained from the SDOs, it is not possible to write to the output buffer, as it is overwritten in each cycle by the data from the IOMapping task. Is there a way, knowing an instance of IoDrvEthercatLib.ETCSlave_Diag, to obtain the pointer to the first data in the IOMapping? The offsets are identical to those of the PDOs, but obviously the data is a copy. For me, the cleanest thing would be to access the pointers on IOMapping, for DS402a devices to retrieve the key data and point them to internal references. I need to know this as, having developed our own motion library, I would like to simplify the initial setup by eliminating unnecessary and nonsensical mappings that can lead users to unnecessary errors. In the current version that we have been using for years, we have to map everything manually. I would like to pass only the slave reference to the FB_init constructors and eliminate the mapping.
Last updated: 2024-02-12
Upgrading CODESYS runtime from v4.7 to v4.9 using a bash script leads to lose the licences stored in the soft container
CODESYS Forge
talk
(Thread)
Upgrading CODESYS runtime from v4.7 to v4.9 using a bash script leads to lose the licences stored in the soft container
Last updated: 2023-09-19
Post by nathant on Saving variable values on power cycle (RevPi Connect)
CODESYS Forge
talk
(Post)
Hello, this seems to be a known issue, but persistent/retain variables don't seem to work properly on RevPi devices. Is there a workaround to this? All I need is for a few configuration variables to be remembered through power cycle.
Last updated: 2023-12-03
Post by mos89p on is it possible to connect to a newer runtime from HMI runtime 3.5.16
CODESYS Forge
talk
(Post)
is it possible to connect to a newer runtime from HMI runtime 3.5.16 via Datasource manager for example a 3.5.20 ?
Last updated: 2024-07-02
Post by trycyclepower on How to set unit in Axis
CODESYS Forge
talk
(Post)
I am very new to Motion in Codesys. I have linear axis and would like to setup as mm, I want to move axis and control axis in mm, mm/s. How do I do that? I know my electronic gearing is 200000.
Last updated: 2024-08-29
Post by damian177 on OPC UA Client
CODESYS Forge
talk
(Post)
The OPC UA Client Example with webvisu is working. Now I would like to use Datasource to connect to OPC UA Server but some is wrong because nothing to do when I try list tags from server - please find in attachement
Last updated: 2024-09-03
Post by timvh on Help with DynamicTextGetTextW
CODESYS Forge
talk
(Post)
First of all you need to enable "Use unicodestrings" in the Visualization Manager. This function returns a pointer to a WSTRING (not STRING). To get this wstring value, do something like this: VAR myWstringVariable : WSTRING(255); END_VAR myWstringVariable := myResult^; // this is dereferencing the pointer to the WSTRING.
Last updated: 2024-09-03
Post by timvh on CoDeSys 3.5 SP20 "No Offline Help installed"
CODESYS Forge
talk
(Post)
Open the CODESYS Installer (from the menu Tools). Go to Browse. Search for: help ... Select the CODESYS Offline Help which you would like to install. (probably you have to close CODESYS to install it and reopen it after installation).
Last updated: 2024-10-01
Trying to pull Logged In user details and certain other variable values and in turn log to a database
CODESYS Forge
talk
(Thread)
Trying to pull Logged In user details and certain other variable values and in turn log to a database
Last updated: 2024-11-07
Post by rckalex on Changing Trace Variable at Runtime
CODESYS Forge
talk
(Post)
Is it possible to change the variable being traced during runtime? I would like to use the CURRENTCLIENTID in combination with an array of real numbers to alter the traced variable in a display window, without needing to create separate visualizations for each variable.
Last updated: 2025-01-22
Post by xlfll on How to use libdoc to implement libraries in multiple languages
CODESYS Forge
talk
(Post)
po file to generate translation file mo, how to mo file into lmd file into the compilation library? This is not clearly described in the codesys help. Does anyone know? codesys help:https://content.helpme-codesys.com/en/LibDevSummary/localization.html#deployment-of-translated-documents
Last updated: 2025-03-13
Post by peterkcontrols on Codesys Network driver install for Codesys Control RTE x64
CODESYS Forge
talk
(Post)
Resolved this. There is a config file called CodesysControl_User that I had to edit to set the driver to component 5. I deleted the semi colon next to Component.5=CmpEt1000Drv
Last updated: 2025-03-19
Post by dat422 on OPC UA Method - How to wait for result?
CODESYS Forge
talk
(Post)
Hi, I am also interested to know on how to use the Codesys OPCUA Client to call methods from e.g. a python opcua server.
Last updated: 2025-03-28
Post by altus22 on Type SM3_Drive is not equal to type SM3_Drive
CODESYS Forge
talk
(Post)
Another way to resolve this is to set Codesys to use a specific version of the offending library under Placeholders in the Library Manager.
Last updated: 2025-04-17
Post by keith on Ethernet Adapter issues
CODESYS Forge
talk
(Post)
I uploaded this project and it was running. After upload I had to re-download to get the system to sync up. I now have this fault and am not sure how to resolve it.
Last updated: 2025-08-14
Post by kurtk on How to change keyboard layout on the virtual keyboard?
CODESYS Forge
talk
(Post)
I have never seen a codesys keyboard with anything other than the german layout I'm hoping to find a US Keypad layout so as not to do all the surgery to co-erce a german Layout into English duty
Last updated: 2025-09-17