Post by wmoon on Licensing info not available. CODESYS Forge talk (Post)
That command can't excute on my device. I installed CODESYS into Hilscher's product using container Here is the Docker file what I used. I'm not sure if this docker file have a problem. If it have a problem, please let me know how to download the files into my device using ftp server. FROM arm64v8/debian:11.6 RUN apt-get update RUN apt-get install -y wget sudo unzip libusb-1.0-0-dev procps ENV CDS_VERSION "4.10.0.0" ENV EDGE_VERSION "4.10.0.0" ENV URL "https://store-archive.codesys.com/ftp_download/3S/LinuxARM64/2302000039/$CDS_VERSION/CODESYS%20Control%20for%20Linux%20ARM64%20SL%20$CDS_VERSION.package" ENV EDGE_URL "https://store-archive.codesys.com/ftp_download/3S/EdgeGatewayLinux/000120/$EDGE_VERSION/CODESYS%20Edge%20Gateway%20for%20Linux%20$EDGE_VERSION.package" RUN wget --output-document=/tmp/codesys.package $URL && \ unzip -p /tmp/codesys.package 'codemeter.deb' > /tmp/codemeter.deb && dpkg -i /tmp/codemeter.deb && \ unzip -p /tmp/codesys.package 'codesyscontrol.deb' > /tmp/codesys.deb && dpkg -i /tmp/codesys.deb RUN wget --output-document=/tmp/edge.package $EDGE_URL && \ unzip -p /tmp/edge.package '*arm64.deb' > /tmp/edge.deb && dpkg -i /tmp/edge.deb EXPOSE 11740 1217 11743 ENTRYPOINT ["/bin/sh", "-c" , "/etc/init.d/codesyscontrol start && /etc/init.d/codesysedge start && tail -f /dev/null"]
Last updated: 2024-03-20

Post by sanacfu on looking for v2.3 libraries on v3.5.19 CODESYS Forge talk (Post)
Hi all, I'm new to Codesys and Wago but well versed in Rockwell. I've been tasked with upgrading old Wago 750-880 PLCs that run Codesys v2.3. All I was giving is the original PLC program in v2.3 and the currently running machine. I've spec out to what I believe is a suitable upgrade, the PFC100 2ndGen, 750-8111. As I'm rewriting this code on the Codesys I can't find the same library functions blocks for ethernet settings PLC functions. Currently I'm working on code to get/set the PLC ethernet IP address and HMI IP addresses from the HMI screen. One other function I'm looking for is a warm reset function to the PLC. When googling for this stuff I see a lot of code not in ladder logic. Are these functions now not available to implement in ladder logic? Where can I get more information on finding and implementing this functions? Do I have to buy a license from Codesys to use these functions? The PLC I ordered should be arriving in 2-3 weeks.
Last updated: 2024-03-25

Post by konstantin on Lenze i950 Servo and WAGO PFC200 CODESYS Forge talk (Post)
Hello, In our workshop we have a Lenze i950 servo drive that has an EtherCAT bus and CiA402 compatibility. The WAGO is PFC200 750-8212 and as per documentation it has built-in license for SoftMotion Light functionality. It is not capable of supporting the full SoftMotion functionality like gearing and synchronizing. I added the EtherCAT esi files from Lenze and the EtherCAT master does see the drive, then I added a SoftMotion Light Axis object. The problem is that I can only energize the axis, I cannot execute any other commands. I set the positive and negative torque limits from the PDOs to 200% and when I try to move the axis by force it does not move back to its original position. I use the SML function blocks from the PLCOpen library and the error from the function blocks is that the op mode cannot be changed. Then I tried using a standard SoftMotion axis object and everything works fine, except the MC_Home function block. The axis moves back to its position when forced out of it. I follow this guide from Lenze - Lenze i950 CODESYS V3 What could cause this issue with the SoftMotion Light axis object? Best Regards Konstantin Kolev
Last updated: 2026-02-11

Post by bschraud on runtime received SIGABRT CODESYS Forge talk (Post)
Hallo, seit der Umstellung meines Projektes auf die aktuelle Codesys Version mit aktuellen Bibliotheken und Aktualisierung der Runtimer Version bekomme ich im Zeitraum 15min bis 1h nach Neustart des Target Systems folgende Fehlermeldung: runtime received SIGABRT - system may be in an inconsistent state Der Fehler kommt auch nach dem Start des Systems ohne eine Benutzeraktion zuverlässig, aber in unterschiedlichen Zeiträumern. Hier sind die Logs und Daten, die ich dazu ermitteln konnte: $ tail -f /var/opt/codesys/codesyscontrol.log 2025-04-03T06:54:37.659Z, 0x0000100c, 1, 0, 0, Visu_PRG: Creating Client for Extern-ID: 594337835 2025-04-03T06:54:37.660Z, 0x0000100c, 1, 0, 0, Visu_PRG: Creating Client successful for Extern-ID: 594337835 Returned IEC-ID: 0 2025-04-03T07:01:38.135Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state * We recommend a reboot of the controller now! 2025-04-03T07:01:38.135Z, 0x00000111, 8, 260, 3, #### Exception: HANDLED EXCPT* <excpt>NonContinuable</excpt> in CH_COMM_CYCLE 2025-04-03T07:02:18.181Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state * We recommend a reboot of the controller now! 2025-04-03T07:02:18.181Z, 0x00000111, 8, 260, 3, #### Exception: HANDLED EXCPT* <excpt>NonContinuable</excpt> in CH_COMM_CYCLE $ vmstat 1 procs -----------memory---------- ---swap-- -----io---- -system-- ------cpu----- r b swpd free buff cache si so bi bo in cs us sy id wa st 1 0 0 271120 33976 342284 0 0 135 2 2387 4751 10 7 82 1 0 1 0 0 271024 33976 342380 0 0 0 0 10163 20427 10 9 81 0 0 1 0 0 271056 33976 342380 0 0 0 0 8455 16869 9 5 86 0 0 0 0 0 271040 33976 342380 0 0 0 0 8674 17484 9 4 87 0 0 0 0 0 271072 33976 342380 0 0 0 0 10070 20350 7 7 87 0 0 1 0 0 271040 33976 342380 0 0 0 0 10354 20802 10 6 84 0 0 0 0 0 271072 33976 342380 0 0 0 0 8401 16923 8 6 86 0 0 $ vcgencmd measure_temp temp=56.9'C $ uname -a Linux PAC4 5.10.103-v7+ #1529 SMP Tue Mar 8 12:21:37 GMT 2022 armv7l GNU/Linux CODESYS V3.5 SP21 Runtime: Codesys control for Raspberry Pi MC SL V 4.13.0.0 Hinweise auf ein instabiles OS oder instabile Netzwerkverbindungen konnte ich keine finden. In dmesg und im syslog gibt es keine Auffälligkeiten. Die anderen Posts zu diesem Thema wurden nicht beantwortet. Hat jemand einen Tip, wie man an das Problem herangehen kann? Vielen Dank
Last updated: 2025-04-03

Post by baltzer on ICertificateVerifier.VerifyCertificate doesn't appear to override an ERR_CERT_HAS_EXPIRED rejection in TCP_Client.Upgrade() CODESYS Forge talk (Post)
Follow-up: working workaround found (routing TLS outside CODESYS) For anyone finding this thread later with the same problem (a third-party device presenting a self-signed and/or expired certificate that ICertificateVerifier/udiVerificationMode won't let you connect through) - we never got a working fix within NBS itself, but found a practical workaround worth sharing. Approach: run a local TLS-terminating proxy on the same host as the CODESYS runtime, and have CODESYS talk plain, unencrypted TCP to it instead of connecting to the remote device directly over TLS: CODESYS --plain TCP--> 127.0.0.1:<port> --stunnel/TLS--> <remote device>:<port> We used stunnel (client mode), with certificate verification explicitly disabled at that layer (verifyChain = no, verifyPeer = no) - a simple, well-documented one-line option, unlike anything we could get working inside NBS. Running it as a systemd service with Restart=always means it survives reboots and recovers automatically if the proxy or the remote device drops. On the CODESYS side, this required no changes beyond pointing TCP_Client at 127.0.0.1 instead of the device's real IP, and removing the TLSContext/ICertificateVerifier code entirely - the rest of our application-layer logic (framing, checksums, etc.) was completely unaffected, since none of that ever depended on where the TLS termination happened. Confirmed working end-to-end against a real device with an expired self-signed certificate, running on CODESYS Control for Raspberry Pi SL (Linux). We haven't yet set this up on Windows - stunnel does have Windows builds available, so the same general approach should be possible there too, but that combination isn't tested or confirmed by us at this point. Caveat: this only makes sense when the proxy and the CODESYS runtime are on the same trusted host (in our case, both on the same Raspberry Pi) - don't expose the proxy's plaintext side on a reachable network interface, since that would create an unauthenticated plaintext path to the device. The original question - whether there's a supported way to override an ERR_CERT_HAS_EXPIRED/self-signed rejection from within NBS's own TLSContext/ICertificateVerifier - remains open as far as we know. Still happy to hear from anyone who's solved that particular piece, since the workaround above is a practical detour rather than an actual answer to the original question.
Last updated: 2026-08-06

Post by pra83 on CODESYS SoftRedundancy — Both PLCs stay standalone after network interruption — Auto recovery not working CODESYS Forge talk (Post)
Hello, We are facing a critical issue with CODESYS SoftRedundancy that we have been unable to resolve despite extensive troubleshooting. HARDWARE: 2× HP EliteDesk 800 G9 SFF Intel Core i7-14700 (20 cores) 16GB RAM, 512GB NVMe SSD Windows 11 IoT Enterprise LTSC 2024 NIC1: Built-in Intel GbE NIC2: Intel I210-T1 PCIe (NIC team) SOFTWARE: CODESYS Control Win V3 - x64 Version 3.5.22.10 CODESYS SoftRedundancy SL Server 1 IP: 172.10.10.101 (PLC1 — Active) Server 2 IP: 172.10.10.102 (PLC2 — Standby) CURRENT CODESYSControl.cfg: [CmpRedundancy] BootupWaitTime=120000 StandbyWaitTime=12100 SynchronousTimeout=12100 [CmpSchedule] ProcessorLoad.Maximum=80 WatchdogTime=12000 WatchdogTimeoutAction=0 CONFIRMED WORKING: PLC1/PLC2 identification configured via IDE Connection IP configured via IDE AutoSync enabled and written via IDE Normal Active/Standby operation working Server 2 auto-promotes when Server 1 completely fails PROBLEM DESCRIPTION: When NIC1 cable is removed from Server 1 — both servers go to standalone mode. When NIC1 cable is reconnected — both servers remain in standalone indefinitely. Neither server auto-recovers to Active/Standby without manual CODESYS service restart. AutoSync fires (!!! Autosync !!! visible in log) but recovery does not complete. Tested with direct cable (no NIC team) — same result. Confirmed not a hardware or NIC teaming issue. KEY LOG MESSAGES: "Timeout: No sync message RMSG_StartCycle (5) from master: Standalone" "Socket on other side closed gracefully 0" "Standby PLC: Open acyclic work socket failed" "Connection broke after 11806ms. Check BootupWaitTime." Autosync(fires but does not complete recovery) PCAP ANALYSIS (Wireshark): CODESYS sync stops completely at T+3s Server 1 sends TCP FIN on ports 1206 and 1208 at T+5s No CODESYS redundancy traffic for remaining 24 seconds Both servers stay standalone indefinitely WHAT WE HAVE TRIED: StandbyWaitTime = 12100ms SynchronousTimeout = 12100ms WatchdogTime = 12000ms (less than StandbyWaitTime) AutoSync enabled NIC2 set as Standby adapter Disabled Windows Network Discovery Direct cable test — rules out NIC hardware QUESTION: Per official CODESYS documentation: "No automatic Reconnect is included in the functional scope of the redundancy components. You can program the triggering of a reconnect." Is RDCY.Synchronize() the correct function to add to our application for automatic recovery after both PLCs go standalone? What is preventing auto-recovery when AutoSync is enabled and PlcIdent is correctly set? Thank you for your support.
Last updated: 2026-05-02

Post by cfam on Codesys Control for PLCnext (PLC - AXL F 2152) CODESYS Forge talk (Post)
Good day All I would like to share some information on this site for the Codesys team as well for the future members using Codesys Control for PLCnext if it is allowed. I hope that i Post it in the correct spot. Subject: Codesys, Codesys Control for PLCnext Objective: Using the following Phoenix components to built a PLC Rack and run it on Codesys: Hardware and Software used 1. 2404267, AXC F 2152 - Controller 2. 1088136, AXL F BP SE6 - Module carrier 3. 1088129, AXL SE DO16/1 - Digital module 4. 1337224, AXL SE PD16 GND - Potential distributors 5. 1088127, AXL SE DI16/1 - Digital module 6. 1337223, AXL SE PD16 24V - Potential distributors 7. 1088123, AXL SE AO4 I 4-20 - Analog module 8. 1088134, AXL SE SC-A - Cover 9. Codesys v3.5 SP19 Patch 4 10. Codesys Control for PLCnext V4.10.0.0 Process: Firstly I built the Rack according to the Phoenix Project+ Software tool. Where I rebuilt it onto my test bench . I used the PLCnext Engineer IDE from Phoenix and all Communications where up and running and my PLC program executed successfully. THEN I tried the same PLC Layout with Codesys and Codesys Control for PLCnext. It was not successful and gave me the "Error: Local Bus not Running". I searched the web for answers but was unsuccessful in finding a solution. So I tried to change my configuration and found that the following Modules COULD NOT be recognized by Codesys Control. The result was that the Local Bus Failed to run. 1337224, AXL SE PD16 GND - Potential distributors 1337223, AXL SE PD16 24V - Potential distributors Example 1, Resulted in "Error: Local Bus Not Running": Module carrier slot 1: 1088129, AXL SE DO16/1 - Digital module Module carrier slot 2: 1337224, AXL SE PD16 GND - Potential distributors Module carrier slot 3: 1088127, AXL SE DI16/1 - Digital module Module carrier slot 4: 1337223, AXL SE PD16 24V - Potential distributors Module carrier slot 5: 1088123, AXL SE AO4 I 4-20 - Analog module Module carrier slot 6: 1088134, AXL SE SC-A - Cover Example 2, Result "Successful": Module carrier slot 1: 1088129, AXL SE DO16/1 - Digital module Module carrier slot 2: 1088127, AXL SE DI16/1 - Digital module Module carrier slot 3: 1088123, AXL SE AO4 I 4-20 - Analog module Module carrier slot 4: 1088134, AXL SE SC-A - Cover Module carrier slot 5: 1088134, AXL SE SC-A - Cover Module carrier slot 6: 1088134, AXL SE SC-A - Cover Result: Codesys or Codesys Control for PLCnext, has a PROBLEM to identify the following Modules. 1. AXL SE PD16 24V - Potential distributors 2. AXL SE PD16 GND - Potential distributors Hope that this information could be useful in future. Best regards Jaco Pretorius
Last updated: 2023-12-06

Post by steven-schalm on Github Actions CI/CD tasks - development topic CODESYS Forge talk (Post)
hello kevinrn, I've been looking for a solution to the CI/CD issue for a long time. Briefly about me... I am 32 and software architect for Codesys V3 and fullstack dev for web (VueJS, NestJS) in a small company in Erfurt (Germany). https://www.rex-at.de/. Through my web part, we already have CI/CD running well via GitLab (YAML-based configuration file (.gitlab-ci.yml), which defines which pipelines and jobs are executed when certain events occur) with everything you know. Stages for npm packages - prepare (GitVersion, npm install or whatever) - build (vite, tsc or whatever) - testing (vitest, jest or whatever) - deploy (npm packages) And similar for monorepo's or backend services (in NestJS) as DockerImages. For Codesys we have been building an OOP framework for years (~50 libraries now), which is currently managed via SVN and a specially written Svn-Watcher (in Python) gets commits and runs and builds everything together and deploys it to an FTP server and network drive. Why do we still have SVN? Because we are unfortunately still tied to the safety integration of Codesys and can therefore only go to SP15 at most with our controller/Eckelmann. But soon there will be an update and there will be no more obstacles to using Git. Hence my questions: 1. the basic idea is to run a local Windows Runner on some machine? 2. install Codesys on the machine where the runner is running? 3. powershell & python scripts are then used to execute builds (compile, build, sign libraries) & deploys? 4. can the Github action also be used in GitLab? ChatGPT has already told me that it's not the same, but it doesn't hurt to ask. Do you have any ideas on this? Greetings :D
Last updated: 2024-08-20

Post by damian177 on Codesys V3.5 + Pixtend v1.3 + RaspberryPi CODESYS Forge talk (Post)
Hi, I use Pixtend v1.3 with my RaspberryPi with Codesys V3.5 SP15 Patch1. Actually in my project I used two packages: - CODESYS Contro for Raspberry PI 3.5.15.10 - PiXtend for CODESYS 1.3.8.0 Now I would like to extend my project about the IIot Libraries SL package, I installed them. Next I added SMS_Service_SL 1.0.0.8 version library and I have problem with compile my project because I get error: [ERROR] PiXtend_DemoProject_q: Library Manager [Device: PLC Logic: Application]: Could not open library '#CAADTUtil'. (Reason: The placeholder library 'CAADTUtil' could not be resolved.) Any have idea what can I do to properly add SMS library to my project?
Last updated: 2023-09-26

Post by jerry-sorrells on Find Function: Object reference not set to an instance of an object. CODESYS Forge talk (Post)
Build: CODESYS 3.5 SP19 Patch 1 (64-bit) Host OS: Windows 10 Target: Linux SL I have a project with programs in Structured Text and Ladder Diagram. When I try to use the Find function, it works for the Active Editor; however, when I try to use Find for the Entire Project, I get the error "Object reference not set to the instance of an object." I know what this error means in the context of the program, but I have no idea why the find function is returning this error. The variable I am searching does not matter: it happens with all variables. Any help with this will be greatly appreciated. I generally use the Find function quite often as I am developing and not having it is really slowing me down.
Last updated: 2023-10-23

Post by wbj0t on Global variable access by Programms and Modbus Devices (attach device to bus) CODESYS Forge talk (Post)
Hi everyone. I use Raspberry Pi 4, one core codesys SL. I have a question about global variable access via programm when I glued the same variable to MODBUS SERIAL/TCP DEVICE holding register. So, the question: what behavior of this modifying? When I set "Always update variables (in bus cycle)" and set some task as bus for the Device, then in another task I cant change this varible (can, but immediatly the old value setted again). But the same things works with MODBUS SLAVE: again "Always update..." and master attached to some task, then I change variable in another task and all works. I cant set up my variables from retains file at PrepareStart event because of this behavior with MODBUS SERIAL/TCP DEVICE. Thanks, wbj0t.
Last updated: 2024-07-18

Post by hazarath on How extract JSONElement containing Array data CODESYS Forge talk (Post)
I want to extract each element of an Array. Can someone help me with this. When I use JSONElementToString (part of JSON Utilities SL), I am seeing output as "ARRAY" instead of actual data. Here is the JSON content that I want to read : { "value1Unit": { "units": "M" }, "data": { "stepSize": 300.23, "points": [6,8] } } I would like to read each item of the element "points" i.e. 6 and 8. Here is the code I used, // Reading the content as JSON reader ( xExecute := execute , pwData := ADR ( converted_value ), jsonData := jsonDataStorage ); // Get the JSON Element jsonDataStorage.FindFirstValueByKey( wsKey := fidKeyVar, diStartIndex := searchElem, jsonElement => jsonElement ); JSON.JSONElementToString ( element := jsonElement , wsResult := valueWstring ); The content of the output of valueWstring is shown as "ARRAY" instead of the array items i.e. 6 and 8 Please can someone help me.
Last updated: 2024-07-30

Post by cihangur on OpC UA server on Raspberry Pi 64 SL runtime CODESYS Forge talk (Post)
After my tests, I noticed two issues. 1- WinCC disconnects the connection after receiving the GetEndPointResponse message from CoDeSys. (I found it with UAExpert and Wireshark.) 2- It establishes a connection despite waiting for a while on the network with DNS. As a result of this information: I solved the problem by adding the line "193.193.193.150 t9pac" to the C:\Windows\System32\Drivers\etc\hosts file and making Windows accept messages coming from the IP number 193.193.193.150 as coming from t9pac. (t9pac is the name of my PLC running CoDeSys.) If there is a setting that will allow CoDeSys OPC UA to respond to GetEndPointRequest with its IP address, this problem will not occur.
Last updated: 2024-12-12

Post by twofacexx on Package Sound Demo funktioniert nicht CODESYS Forge talk (Post)
Moin, ich grab mal den alten Thread hier aus, habe das gleiche Vorhaben, Sounds auf dem Raspberry abzuspielen. Habe einen Pi5 mit Codesys Pi 64 SL und benutze auch die SysProcessExecuteCommand sowie die SysProcessExecuteCommand2. Habe das auch schon erfolgreich umgesetzt um Kamerabilder aufzunehmen und Bilder zu kopieren, aber die Sounds funktionieren leider nicht. Wenn ich direkt in der Konsole die Befehle eingebe, werden die Sounds abgespielt, werden diese aber durch Codesys getriggert, wird kein Sound abgespielt. Ich habe bis jetzt - espeak - espeak-vg - aplay - omxplayer versucht. Alle in die CodesysControl_User.cfg eingetragen etc und keine Fehlermeldung beim ausführen. Habe BT Headset und USB Headset getestet, wie gesagt, direkt in der Konsole gehts, durch Codesys nicht. Hat irgend jemand eine Idee woran es liegen könnte?
Last updated: 2025-03-13

Post by jeroenaero on Targetvisualisation full screen with CmpTargetVisu settings CODESYS Forge talk (Post)
Hi, How can i display targetvisualization in full screen on the target device? I installed Targetvisu For Linux SL 4.16.0.0 on target device which contains Raspberry PI 64bit PIXEL desktop. When i connect my PLC program to the remote targetvisu, the targetvisu displays for 60% horizontally. We contacted CODESYS and they said it is a bug. they had a workaround, and with the settings below added to the file /etc/codesysvisualization/CODESYSVisualizationTV.cfg, the targetvisualization display for 100%, but with the taskbar at the top. VisuClient.BestFit=1 ;VisuClient.ScaleTypeIsotropic=0 VisuClient.FillWholeBackground=1 [CmpTargetVisu] WindowPositionX=0 WindowPositionY=0 WindowSizeWidth=1280 WindowSizeHeight=800 WindowType=2 How can we let it display fullscreen without taskbar?
Last updated: 2025-07-24

Post by mondinmr on COL.IMap2 and HashTableFactory cause frequent Access Violation CODESYS Forge talk (Post)
Good morning, I’ve been using the Collection library for a long time, mostly with Stack, LinkedList, and List. From your examples I was able to manage the different factories, even for custom elements. Now I need a hashtable, but with this object I’m running into a lot of random access violations. If I append something inside FB_Init after constructing the hashtable, it crashes, even though the list was already created. If I only create the hashtable in FB_Init and append afterwards, it usually works. I don’t understand the meaning of the dispose call in this code: pSlave := ADR(slave); uSlave := TO_ULINT(pSlave); iKey := fKey.Create(uSlave); IF hash.CountKeys() = 0 THEN Service.logger.appendLog('Filling hashtable', 'HashManager', AdvLogType.AdvDebugMsg); ok := FALSE; ELSE eError := hash.ContainsKey(iKey, xResult => ok); END_IF IF NOT ok THEN pI := __NEW(UINT); iVal := fKey.Create(TO_ULINT(pI)); Service.logger.appendLog(CONCAT('New slave', TO_STRING(uSlave)), 'HashManager', AdvLogType.AdvDebugMsg); hash.AddKeyValuePair(iKey, iVal); appendNewSlave := pI; ELSE eError := hash.GetElementByKey(iKey, itfValue => iElem); xResult := __QUERYINTERFACE(iKey, itfIInstance); IF xResult THEN itfIInstance.Dispose(); END_IF IF eError <> COL.COLLECTION_ERROR.NO_ERROR THEN Service.logger.appendLog(CONCAT('ERROR ', TO_STRING(eError)), 'HashManager', AdvLogType.AdvCriticalMsg); appendNewSlave := nullptr; RETURN; END_IF __QUERYINTERFACE(iElem, iVal); {warning disable C0033} pI := TO___UXINT(iVal.UlintValue); {warning restore C0033} appendNewSlave := pI; END_IF Without the dispose call, every second cold reset crashes immediately when I try to access iVal, even if eError doesn’t report any error. With the dispose call, the cold reset issue disappears, but I get other problems: a) If I start the runtime using systemctl start codesyscontrol, it crashes at IF hash.CountKeys() = 0 THEN b) If I delete the files in PlcLogic and download again, it works and survives multiple cold resets. But as soon as I run systemctl restart codesyscontrol, everything gets corrupted again and it starts crashing at that point. FUNCTION_BLOCK SlaveMapCounter VAR hash : COL.IMap2; eError : COL.COLLECTION_ERROR; END_VAR In its FB_Init I create it: METHOD FB_Init: BOOL VAR_INPUT bInitRetains: BOOL; // TRUE: retain variables are initialized (reset warm / reset cold) bInCopyCode: BOOL; // TRUE: the instance will be copied to the copy code afterward (online change) END_VAR VAR hF : COL.HashTableFactory; END_VAR hash := hF.Create(256); In another FB I instantiate it statically: FUNCTION_BLOCK ABSTRACT AbstractServoEthercatController EXTENDS AbstractServoController VAR_STAT hashSlaves : SlaveMapCounter; END_VAR VAR field : REFERENCE TO ADVAbstractFieldUnitEthercatCia402; initCnt : REFERENCE TO UINT; END_VAR The append method is the one shown above, and I call it after the runtime has started. The accesses are performed by a single task, and in any case I’m working on an isolated single core. I’ve tried everything, moving the create, the instances, and all the rest several times, but nothing seems to work. I’d like to point out that these FBs are part of our own library, which is used in many applications.
Last updated: 2025-09-11

Post by snhatton on OpC UA server on Raspberry Pi 64 SL runtime CODESYS Forge talk (Post)
Good afternoon, After changing the security settings to: CommunicationPolicy: POLICY_BASICSHA256SHA256 CommunicationMode: ALL Activation: Activated UserAuthentication: ENABLED Then generate a new certificate on the device for the OPC-UA server from Security Agent->Device->OPC UA Server. Restart the runtime using tools->Update Raspberry Pi->Stop->Start for the changes to take effect. It may take a minute for the runtime to start. Initiate the connection from the UA server side. You should see a pop-up asking you to trust the certificate. Click on the button 'Trust Server Certificate'. Next, you should see a certificate in the quarantined folder of the security agent in CODESYS. Click and drag this from quarantined to trusted and then try connecting from UA expert to the device. These steps worked for me and my setup and I hope they can help you!
Last updated: 2023-12-11

Post by amy123 on codesys mqtt publish serialization CODESYS Forge talk (Post)
Hello, I am using the CODESYS IIoT Libraries SL MQTT Publish. Does this publish block only support publishing STRINGS as a readable format? I can publish ENUM, STRUCT, BOOL; however, MQTT Explorer will only display strings. When I use Wireshark, I can see that it is publishing something, but it looks to be publishing a serialized version which is a bunch of 0s or random text. If so, is there any way to deserialize this information back into a readable format? See pictures, where I have a BOOL TRUE that gets published as 001. Then see where I publish a STRUCT and it's an incomprehensible combination of 0s - only the string variable is displayed. Or, is it expected that you convert everything to a string before publishing? Any help is greatly appreciated! :)
Last updated: 2024-02-16

Post by tecnocons on Trouble Writing Files to External Paths in CODESYS CODESYS Forge talk (Post)
Hello everyone, I'm encountering an issue in CODESYS regarding writing files to external paths. Despite correctly configuring the placeholder in the CODESYSControl_User.cfg file to allow access to an external folder, CODESYS doesn't seem to write any files, and no errors are reported. The issue on the older versions was absent with no placeholders. I've checked the operating system permissions, and they seem to be in order, but the issue remains. Has anyone faced a similar situation or has any suggestions on how I might resolve this problem? Any help would be greatly appreciated. Thank you in advance for your support. I'm using raspberry PI as a logger. RPI3 Buster Codesys 32bit SL V4.11 Codesys Win64 3.5.20 [SysFile] PlaceholderFilePath.1=/home/pi/scan, $SCAN$
Last updated: 2024-04-09

Post by ppix on Establishing TLS Connection with MQTT Broker using MQTT Client SL Package CODESYS Forge talk (Post)
For anyone confused with the process visit this link (the bottom section about creating a .pfx file) https://content.helpme-codesys.com/en/LibDevSummary/certificate.html#import-of-client-certificates-with-private-key. I solved this problem by creating a .pfx file and importing it into the security store under 'Own Certificates'(must have SP18 or newer to import .pfx). I used a gitbash shell to enter the openssl command that created the .pfx file. Once you import the file, in your TLS context, set your 'sUseCaseName' to be the same as the name listed in the 'Information' column of your imported certificate. This did it for me
Last updated: 2024-06-20

Post by malte on OPC UA multiple Endpoints CODESYS Forge talk (Post)
My CODESYS OPC UA server provides endpoints using both the hostname and the IP address. Connecting via the IP address works fine, but connecting via the hostname does not. The endpoint list shows both opc.tcp://<hostname>:4840 and opc.tcp://<ip>:4840. When using the hostname, the OPC UA client (UA Expert) fails to connect. Using the IP address connects without issues. Main goal is to conect via Python but opcua-asyncio seems to prefer the hostname. How can I configure CODESYS or my system so that the OPC UA connection via hostname also works properly or disable it completly? Running Codesys for PFC200 sl 4.18.0.0
Last updated: 2025-10-28

Post by hammer on Cartesian XY Chart — 2-D array binding: "Element to use" enumerates the wrong dimension CODESYS Forge talk (Post)
Title: Cartesian XY Chart — 2-D array binding: "Element to use" enumerates the wrong dimension; documented example (Dialog: XY Chart Configuration, "Two-dimensional array of base type REAL") appears transposed Product / version: CODESYS Development System V3.5 SP21 Patch 40 (3.5.21.40). Cartesian XY Chart visualization element (System_VisuElemXYChart / VisuElemXYChart). Summary: When a curve's Data X/Data Y is bound to a two-dimensional array, the element treats the last array dimension as the per-point record (the one selected by "Element to use") and iterates the first dimension as the sequence of curve points. The online documentation's worked example has the dimensions in the opposite order, so following it produces a non-functional curve and a nonsensical "Element to use" list. Steps to reproduce (fails — matches the documented layout): 1. Declare aData : ARRAY[0..1, 0..4095] OF LREAL; (2 data sets × 4096 points, i.e. first dimension = set, second = point). 2. In XY Chart Configuration, bind a curve's Data X (and Y) Variable to this array. 3. Observe the "Element to use" combobox. Actual result: The "Element to use" combobox lists 4096 entries (the indices of the second dimension) instead of 2 (the data sets in the first dimension). Selecting a row does not produce the expected curve; at most a single/degenerate point is plotted. Steps to reproduce (works — transposed): 1. Declare aData : ARRAY[0..4095, 0..1] OF LREAL; (points first, set second). 2. Bind Data X/Y to this array; "Element to use" now correctly lists [0] and [1]. 3. Populate aData[point, set] and the curve plots as expected. Expected result: Either the documented example should select the data set from the first dimension (as its [1]/[2] "Element to use" implies), or the documentation should state that the last dimension is the record dimension (stride) and the first dimension is the point sequence — consistent with how the element actually behaves. Analysis: The behavior is self-consistent if the element always walks a single array by a fixed byte stride, reading one element per point — the same mechanism as the documented "one-dimensional array of a DUT" case, where it strides by SIZEOF(DUT) and "Element to use" picks the member offset. For a 2-D array the record is the last dimension: to plot column/set c it starts at [0, c] and strides by the last-dimension length to reach [1, c], [2, c], … (row-major layout makes this a contiguous column walk). Under that rule, ARRAY[0..N, 0..1] is correct (record length 2 → "Element to use" [0]/[1]), and the documented ARRAY[1..2, 1..50] with "Element to use" [1]/[2] is transposed. Documentation reference: Dialog: XY Chart Configuration → Data X / Data Y → "Example: Two-dimensional array of the base type REAL" (ARRAY[1..2, 1..50], Element to use [1]/[2], "100 array values are displayed"). This example does not plot as described in 3.5.21.40; transposing to ARRAY[1..50, 1..2] does. Request: Please confirm whether this is (a) a documentation error (example dimensions reversed) or (b) an element defect (combobox enumerates the wrong dimension). Either way, a corrected example plus an explicit statement of which dimension is the point sequence vs. the record/stride dimension would prevent others from hitting this. Two separate 1-D arrays for Data X and Data Y work correctly and are unaffected.
Last updated: 2026-08-14

Post by rossanoparis on Upgrading CODESYS runtime from v4.7 to v4.9 using a bash script leads to lose the licences stored in the soft container CODESYS Forge talk (Post)
System information - Controller: KUNBUS RevPi CONNECT-S - OS: Linux buster 32bit 5.10.103-rt62-v7l #1 SMP PREEMPT_RT armv7l GNU/Linux - CODESYS v3.5 SP19 Patch 2 I'm facing a problem related to codesys licences using a procedure based on a bash script. Such bash script detect the presence of new .deb files and install them on system. My automation solution don't allow to be maintained by dedicated personal, thus even the CODESYS runtime SW must be installed using an "automatic" procedure instead of using the CODESYS tool. remark I've been using the following procedure since the runtime v4.5 without any issue. Before installing the new runtime packages, I need to copy the file CODESYSControl_User.cfg (here attached) because of new section which is necessary to add in order to allow some folders to be written by CODESYS runtime v4.9 Up to now, this has been unnecessary, this is the main difference between my previos bash file and the new one. remark If I skip this action, everythings goes fine, but my CODESYS application can't work as it needs to access some folders on controller's file system. Process - Before the procedure: the licenses are OK (see attached file lic-01.png) - After the procedure: the new CODESYS runtime version is correctly installed, but the software container with v1.19 and all licences disappear (see attached file lic-02.png) This is the synthetic content of bash script I'm using. # Stop runtime sudo service codesyscontrol stop sudo service codesysedge stop # Move the new CODESYSControl_User.cfg file # New configuraton with folders declared sudo mv -f CODESYSControl_User.cfg /etc # Install runtime package echo N | sudo apt-get install -y --allow-downgrades codesyscontrol_raspberry_4.9.0.0_armhf.deb # Install edge gateway package echo N | sudo apt-get install -y --allow-downgrades codesysedge_edgearmhf_4.9.0.0_armhf.deb # Reboot controller sudo reboot Thanks in advance
Last updated: 2023-09-19

Post by pruwetbe on Profinet IO-link master - IODD files CODESYS Forge talk (Post)
Hello, we have the same problem here. Our configuration in the following: Codesys V3.5 SP19 running on Exor Exware700Q Profinet network connected on Eth1 IOLink Master Turck TBEN-S2-4IOL version 3.5.9.0 IOLink sensors E+H & Sick (Pressure, T°) We installed the codesys IO link package and have the codesys IO Link SL licence activated (on a dongle) Our problem is the following: we got the IODD files from E+H & Sick we add the devices in the codesys device repository with success They appear in the devices tree under IODD branch We added the TBEN IOLink master under the Profinet IO . The IO link master are ok and display online. The IO-Link SL package datasheet indicate that there would be a way to scan the IOLink device from the network but we did not find any way to trigger this scan. (we expect to get this from a right click on each IO-Link Master module but the only possibility there is "Plug device") When clicking on Plug Device, we get a browse window with profinet IO modules. The IODD devices are not there so we cannot select them. But other devices for other brands are available and can be plugged. Our question are : 1) how do we update the Profinet IO Module catalogue in order to be able to plug the E+H & Sick Sensors that we have to work with? 2) how do we activate the Scan IOLlink device that is supposed to be included in the Codesys IO-link package? 3) where can we find the manual explaining how to use this package?
Last updated: 2024-11-12

Post by wildcard on Modbus Client Request Not Processed CODESYS Forge talk (Post)
Hi, does anyone has a solution for this issue. I've the same problem. I've implemented a very simple client based on the Modbus Examples and connected the soft PLC to a Modbus Simulator. PROGRAM ModbusClient VAR initDone : BOOL := FALSE; errorID : ModbusFB.Error; client : ModbusFB.ClientTCP; timeout : UDINT := 500000; replyTimeout : UDINT := 200000; aUINT : ARRAY [0..8] OF UINT; clientRequestReadHoldingRegisters : ModbusFB.ClientRequestReadHoldingRegisters; clientRequestsCnt : UINT := 0; clientRequestsProcessCnt : UINT := 0; ipAddress : ARRAY[0..3] OF BYTE := [10,54,0,72]; END_VAR IF NOT initDone THEN initDone := TRUE; client(aIPaddr:=ipAddress, udiLogOptions:=ModbusFB.LoggingOptions.All); client(xConnect:=TRUE, ); clientRequestReadHoldingRegisters(rClient:=client, udiTimeOut:=timeout, uiUnitId:=1, uiStartItem:=0, uiQuantity:=4, pData:=ADR(aUINT[0]), udiReplyTimeout:=replyTimeout); clientRequestReadHoldingRegisters.xExecute := TRUE; clientRequestsCnt := 0; END_IF clientRequestReadHoldingRegisters(rClient:=client, udiTimeOut:=timeout, uiUnitId:=1, uiStartItem:=0, uiQuantity:=4, pData:=ADR(aUINT[0]), udiReplyTimeout:=replyTimeout, xExecute := TRUE); IF clientRequestReadHoldingRegisters.xError THEN clientRequestsCnt := clientRequestsCnt +1 ; errorID := clientRequestReadHoldingRegisters.eErrorID; END_IF clientRequestReadHoldingRegisters(rClient:=client, udiTimeOut:=timeout, uiUnitId:=1, uiStartItem:=0, uiQuantity:=4, pData:=ADR(aUINT[0]), udiReplyTimeout:=replyTimeout, xExecute := NOT clientRequestReadHoldingRegisters.xExecute); When the system is running I do get the following on the logs: 2024-05-13T10:18:07.443Z: Cmp=MODBUS lib, Class=1, Error=0, Info=0, pszInfo= Client.RequestProcessed ClientRequest,16#0164ADC561A0 unitId=1 fc=ReadHoldingRegisters id=2070 state=Error 2024-05-13T10:18:07.443Z: Cmp=MODBUS lib, Class=1, Error=0, Info=0, pszInfo= ClientRequest,16#0164ADC561A0 unitId=1 fc=ReadHoldingRegisters id=2070 change state Error -> None timestamp=63843421226 2024-05-13T10:18:08.444Z: Cmp=MODBUS lib, Class=1, Error=0, Info=0, pszInfo= ClientRequest,16#0164ADC561A0 unitId=1 fc=ReadHoldingRegisters id=2071 change state None -> Init timestamp=63844421420 2024-05-13T10:18:09.444Z: Cmp=MODBUS lib, Class=1, Error=0, Info=0, pszInfo= ClientRequest,16#0164ADC561A0 unitId=1 fc=ReadHoldingRegisters id=2071 change state Init -> Error timestamp=63845421675 But the errorID is jumping between OK and RequestNotProcessed. Any help is very appreciated which gives me a hint what I'm doing wrong. Thanks
Last updated: 2024-05-13