Post by davidb on Initialisation TimerSwitch of Util Codesys 3.5 Library CODESYS Forge talk (Post)
Last updated: 2024-10-14

Post by rafaelbrito on The element of type 'VisuFbElemImage' could not be updated. Reason: Index was outside the bounds of the array. CODESYS Forge talk (Post)
When trying to use the Visualization ToolBox, no objects appear and the following error appears. Could you tell me what this error could be? The element of type 'VisuFbElemImage' could not be updated. Reason: Index was outside the bounds of the array. Can anyone tell me what this error is?
Last updated: 2024-12-03

Post by hismoon on Inheritence of struct, CODESYS Forge talk (Post)
--- deleted. Was a bug.
Last updated: 2025-03-14

Post by hismoon on Inheritence of struct, CODESYS Forge talk (Post)
--- deleted. Was a bug.
Last updated: 2025-03-14

Post by hismoon on Inheritence of struct, CODESYS Forge talk (Post)
--- deleted. Was a bug.
Last updated: 2025-03-14

Post by hismoon on Inheritence of struct, CODESYS Forge talk (Post)
--- deleted. Was a bug.
Last updated: 2025-03-14

Post by hismoon on Inheritence of struct, CODESYS Forge talk (Post)
--- deleted. Was a bug.
Last updated: 2025-03-14

Post by laurits on Max lines of code, codesys CNC ? CODESYS Forge talk (Post)
Testing Codesys CNC. SMC Interpolator Throws me an error if my code surpass approximately 32000 lines of code. (SMC_CNC_INTERNAL_ERROR) What is the max lines of code SMC Interpoltor can handle ? I've been thinking breaking the code up into smaller sections, but that gives me a lot problems later if i want to use "Blocksearch" etc. I need to run approximately 2000000 lines of code.
Last updated: 2025-06-01

Post by mondinmr on What happened to Python? CODESYS Forge talk (Post)
What happened to Python? I’ve just installed version 3.5.21.3 of the CODESYS development environment. I’m coming from 3.5.19.5. What happened to Python scripting! We rely heavily on it for the automatic generation of thousands of lines of code! It seems absurd to me that such an important feature has been removed!
Last updated: 2025-10-01

Post by arj3090 on Linux ARM64 Deploy Fail - Index out of range CODESYS Forge talk (Post)
Codesys V3.5 SP22 Patch 2 I am attemtping to install Linux Arm64 SL on a Beckhoff CX9240. When the deploy of the run time begins, an error box pops up with an unhandled exception - Index was out of range. Attached is an image of the error. I am unable to expand the complete error because the software is locked up.
Last updated: 2026-07-01

Forge πŸ‡¬πŸ‡§ CODESYS Forge talk (Discussion)
Discussions about CODESYS Forge projects and features of the CODESYS Forge website
Last updated: 2026-06-15

Post by ucconversions on displaying all incoming CAN bus messages CODESYS Forge talk (Post)
Hello Im using CAN API Im receiving CAN messages with no problem. below is my code. METHOD ProcessMessage VAR_IN_OUT ( Incoming message ) Message : CAN.RxMESSAGE; END_VAR VAR i: USINT; END_VAR recvCANid := Message.udiCanID; IF recvCANid = 16#18FF8247 THEN UserVarGlobal.g_countMsg_RPMset := UserVarGlobal.g_countMsg_RPMset + 1; FOR i := 0 TO 7 DO myDataFF82[i] := Message.abyData[i]; END_FOR END_IF but in this way I can only display CAN messages which I know its ID. I want to display all incoming CAN messages for example first incoming CAN message - I assign it into a variable Message1. second incoming CAN message - I assign it into a variable Message2. third incoming CAN message - I assign it into a variable Message3. Can you give me guidance? Thank you BR
Last updated: 2024-07-18

Post by gilad on CODESYS SoftMotion Generic DSP402 on WAGO PFC200 + Festo CMMT-AS: MC_Power stays Busy, Controlword remains 0 CODESYS Forge talk (Post)
Hello, I am trying to connect a Festo CMMT-AS-C4-3A-MP-S1 servo drive to a WAGO PFC200 (750-8210) using EtherCAT and CODESYS SoftMotion. Hardware PLC: WAGO PFC200 750-8210 Drive: Festo CMMT-AS-C4-3A-MP-S1 Communication: EtherCAT CODESYS version: Device description version 6.3.1.1 Drive firmware: 36.10.3 Current Status EtherCAT communication is working correctly: EtherCAT master = Running Drive detected and operational PDO input and output mapping is active Statusword, position and velocity are updating correctly Current PDO mapping: Outputs: 6040 Controlword -> %QW0 6060 Modes of operation -> %QB2 607A Target position -> %QD1 60FF Target velocity -> %QD3 Inputs: 6041 Statusword -> %IW2 6061 Modes of operation display -> %IB6 6064 Position actual value -> %ID2 606C Velocity actual value -> %ID3 SoftMotion Axis I added a SoftMotion CiA402 axis under the EtherCAT slave: Axis type: SM_Drive_GenericDSP402 Axis communication state: operational (100) No SoftMotion mapping errors anymore Problem MC_Power is executed with: Enable = TRUE bRegulatorOn = TRUE bDriveStart = TRUE but: Status = FALSE Busy = TRUE Error = FALSE ErrorID = SMC_NO_ERROR The axis remains in: SMC_AXIS_STATE.power_off DSP402 state = SWITCH_ON_DISABLED The most important observation: Statusword = 32784 (0x8010) Controlword (%QW0) remains 0 all the time SoftMotion never writes 6, 7, or 15 to the Controlword. Additional Information The axis status page reports: "The license is missing or invalid. The PLC runs in demo mode." I am not sure whether: The missing SoftMotion license prevents Controlword generation completely. The axis is still not correctly connected to the EtherCAT slave despite operational communication. There is an additional CiA402 configuration step required for the Festo CMMT-AS drive. Has anyone successfully used a Festo CMMT-AS MP drive with CODESYS SoftMotion Generic DSP402 on a WAGO PFC200? Any suggestions on what should be checked next would be greatly appreciated.
Last updated: 2026-06-24

Post by timvh on Case Function - Multiple Conditions, Is it possible? CODESYS Forge talk (Post)
This is not possible. Possible solution could be: CASE var1 OF 10: CASE var2 OF 10:; 20:; END_CASE 20: CASE var2 OF 10:; 20:; END_CASE ELSE ; END_CASE
Last updated: 2024-11-05

Post by smartcoco on OPC server in "Communication manager" CODESYS Forge talk (Post)
I don't recommend using 'Communication Manager'. Under 'Communication Manager', the 'NodeId' type of OPC UA can only be of type 'OPAQUE'. This will bring compatibility issues to the development of the upper computer.
Last updated: 2025-01-24

Post by abrarsk on Download libraries of old versions CODESYS Forge talk (Post)
You can download the missing libraries by clicking on the "Download Missing Libraries" button. However, if you were unaware of this and accidentally downloaded the latest version of the library from the Library Repository, you may need to uninstall it first to avoid conflicts.
Last updated: 2025-02-11

Post by rushikeshsonone on Get the list of all languages from TextList or from font settings of visualmanager CODESYS Forge talk (Post)
Hi, I want list of all languages added in text list during runtime. I check with various object call but no luck. Can you help me with that? Note - I can not using Textlistutil, need other solution
Last updated: 2025-03-04

Post by ivanmaltar on Codesys Control shutdown CODESYS Forge talk (Post)
Hello, the problem was that the 4.6.0.0 Codesys control was not compatible with S versions of the RevPi controller because of the becuase of the Compute Module 4S. For those controllers, 4.8.0.0 version must be used.
Last updated: 2024-03-25

Post by danamocca on SM3_CNC Sentence modifier CODESYS Forge talk (Post)
Hi! Does anyone have an example of ReadNCFile2 with Sentence Modifier? Current examples on CODESYS help page are outdated and have a lot of errors, like "SMC_CNC_LibParams.MAX_SUBPROGRAM_NESTING_DEPTH" calls, which are not present in current version of SMC3_CNC library.
Last updated: 2025-12-25

Post by yueqiqi on How to get the instance of a CANopen Master in the Device Tree? CODESYS Forge talk (Post)
I have been wondering of how to get the instance of a Canopen Master in the device tree, please see the picture in the attachment . Could anyone help me?
Last updated: 2026-09-02

Post by eschwellinger on Linux ARM64 Deploy Fail - Index out of range CODESYS Forge talk (Post)
I would check the version of the deloy tool using the CODESYS installer. Sure manually installing works too, but woukd nice to know if there is a problem. Currebt version is 4.21.0.0 of the deploytool.
Last updated: 2026-07-01

Post by ofey on Symbol configuration / GVL CODESYS Forge talk (Post)
Hi! I have som variables that I communicate to a Modbus Master. These variables are declared in a "Global Variable List" where I have assigned them memory addresses. To organize this mapping I want to make a MODBUS list where I show all the variable names together with the memory address. Is there an easy way to export this list from CODESYS? Either through script or some export function maybe?
Last updated: 2023-10-11

Post by ofey on Symbol configuration / GVL CODESYS Forge talk (Post)
Hi! I have som variables that I communicate to a Modbus Master. These variables are declared in a "Global Variable List" where I have assigned them memory addresses. To organize this mapping I want to make a MODBUS list where I show all the variable names together with the memory address. Is there an easy way to export this list from CODESYS? Either through script or some export function maybe?
Last updated: 2023-10-11

Post by camjam on BOOL variable in OPC UA and modbus simultaneously CODESYS Forge talk (Post)
I have come across this. The only way i could get it to work would be to define a word that is also the same address as the Bools. eg %MX600.0 through to %MX600.15 would be individually defined in the variables and them have another variable word defined at %MW300. You still need to break out the word in what ever program you are using to read/write the OPCUA tags.
Last updated: 2025-08-18

Post by stefan-gimpl on Beobachtungszeitpunkt CODESYS Forge talk (Post)
Guten Tag, irgendwas ist hier im Argen, die Status werden nicht richtig angezeigt. Im Bild im Anhang wird die Variable in Zeile 16 CollectiveAlarm auf false gesetzt, es wird aber true angezeigt. In Zeile 17 frage ich testweise den Status nochmals ab, der ist auch false, obwohl die Variable CollectiveAlarm noch immer true anzeigt. Was kann hier die Ursache sein? Gibt es einen Beobachtungszeitpunkt, wann die Werte abgefragt werden?
Last updated: 2026-03-04