Post by gatto on CAA File open Problems CODESYS Forge talk (Post)
Ciao, here same question https://forge.codesys.com/forge/talk/Engineering/thread/2538729618/ in this post https://forge.codesys.com/forge/talk/Engineering/thread/4586a90290/?limit=25#d531 i find : keep in mind that all files which are generated / or read should be exist in the iecfilepath this means: for Windows (Control Win as example) c:\ProgramData\CODESYS\CODESYSControlWinV3x64\268E8ADF\PlcLogic for Linux /var/opt/codesys/PlcLogic I never use codesys on windows but im sure on linux we can manipulate file only inside /var/opt/codesys/Plc Logic. Or you need to modify the file codesyscontrol.cfg for change path permission, but this is another history Buone feste !
Last updated: 2024-12-21

Post by sigurdrb on Read codesys version in the codesys application CODESYS Forge talk (Post)
Hi! I want to read the codesys version into the project, so I can highlight it in the SCADA system. VAR dwVersion : DWORD; END_VAR SysTarget.SysTargetGetVersion(pulVersion := ADR(dwVersion)); This gives me the value 100859909. I tried to search ths up and found som older post (https://forge.codesys.com/forge/talk/Runtime/thread/a55981ff4d/) that said each 4 bytes reads a number in the version. Example is 50662666 = 16#03050D0A which reads to V3.5.13.10 When I run this code I get the value 100859909, which I cant translate to anything meaningful. I am running it on Codesys V3.5.19.70. Help appreciated!
Last updated: 2025-01-17

Post by janber0206 on Adding PLC to the List view resolves in Unknown Error CODESYS Forge talk (Post)
Problem Solved The Problem was within the Usermanagment. There should be 6 files for the Usermanagment in /var/opt/codesys/ .UserMgmtDB.csv .UserMgmRightstDB.csv .GroupDatabase.csv .UserDatabase.csv_ .GroupDatabase.csv_ .UserDatabase.csv The file .UserMgmtDB.csv was missing. I moved the other files in a savefolder. Full Step by step instructions stop the runtime with sudo /etc/init.d/codesyscontrol stop rename the following files on the PI: (or save them and then delete them) in this directory: /var/opt/codesys/ .UserMgmtDB.csv .UserMgmRightstDB.csv .GroupDatabase.csv .UserDatabase.csv_ .GroupDatabase.csv_ .UserDatabase.csv then restart the Runtime: sudo /etc/init.d/codesyscontrol start now reconnect the PLC via the Automation Server - here you will be asked to create a new CODESYS user password, The user management files deleted above are then created again (in /var/opt/codesys/ on the PI).
Last updated: 2025-02-24

Post by matthew on High resolution displays with 150% scaling causes CodeSys IDE to be blurry CODESYS Forge talk (Post)
I have just upgraded my laptop which has a high res display 2560x1600 and I have to have scaling switch on at 150% but everything looks blurry and not crisp, It seems CodeSys IDE is the only software on my system to look this bad, if I switch to 100% it's crisp but way to small. From a bit of research this could be due to the use of old windows forms or something? I have found a temp workaround that sort of works but not great. You have to run CodeSys in compatibility mode and adjust the DPI settings, this works ok and the editor is clear and crisp again but the actual tool bars are small like running at 100% Anyone got any tips for running CodeSys on high res displays with scaling?
Last updated: 2025-03-03

Post by elsmart on How to create custom visualisation components (widgets)? CODESYS Forge talk (Post)
Hello I'm currently working on a project where I need to implement visualisation in Codesys on Raspberry Pi via web browser. I'm uing Codesys IDE V. 3.5 and I was able to successfully run my program and visualisation using generic elements provided by Codesys on Raspberry Pi Compute Module 4. However I am dissatisifed by the limiations and looks of generic elements. I would like to create my own components for this specific task (like cyclic buffer with messege boxes or matrix of data structures). How do people develop their own visualisation components in Codesys and how to implement them in a project?
Last updated: 2025-05-27

Post by s1mon on Two OneWireMaster on one Raspberry PI 5 CODESYS Forge talk (Post)
Hi, I want to use two OneWireMaster on a Raspberry Pi5. I'm running Codesys Control for Raspberry Pi 64SL V 4.15.0.0. Under Linux I've configured two GPIOs for 1w bus usage on GPIO4 and GPIO27. Under Linux both masters seem to work fine and I can readout both sensors connected to both GPIOs. The two masters are 'w1_bus_master1' and 'w1_bus_master2'. In Codesys I've configured to OneWireMasters with the corresponding file paths. But in Codesys the 2nd onewiremaster "w1_bus_master2" doesn't work. Status is showing "OnewireMaster : Not running" What am I doing wrong? Does Codesys on Raspberry support multiple OneWireMasters? Any help is appreciated.
Last updated: 2025-06-10

Post by s1mon on Two OneWireMaster on one Raspberry PI 5 CODESYS Forge talk (Post)
Hi, I want to use two OneWireMaster on a Raspberry Pi5. I'm running Codesys Control for Raspberry Pi 64SL V 4.15.0.0. Under Linux I've configured two GPIOs for 1w bus usage on GPIO4 and GPIO27. Under Linux both masters seem to work fine and I can readout both sensors connected to both GPIOs. The two masters are 'w1_bus_master1' and 'w1_bus_master2'. In Codesys I've configured to OneWireMasters with the corresponding file paths. But in Codesys the 2nd onewiremaster "w1_bus_master2" doesn't work. Status is showing "OnewireMaster : Not running" What am I doing wrong? Does Codesys on Raspberry support multiple OneWireMasters? Any help is appreciated.
Last updated: 2025-06-10

Post by pauloricardoss on Codesys Control Raspberry PI 4.10.0 - missing 'Update Raspberry PI' option CODESYS Forge talk (Post)
I am having the same problem. 'Update Raspberry PI' disappeared from the 'Tools' menu. Using RaspberryPI 3B+, Codesys V3.5 Sp21 + RaspberryPI Package 4.16. I installed the package as Administrator, executed Codesys as Administrator I also tried to connect using the deploy (even with ssh and everything enabled on the RaspberryPi I received password denied). I used in the past the same equipment with Codesys V3.5 Sp18 and RaspberryPI Package 4.08, it was really easy. (I also did a brand new RaspbianOs installation to make sure that nothing affect the connection). Anyone, knows how to fix it? Thanks,
Last updated: 2025-06-13

Post by arjunk on How to correctly create a device descriptor (.devdesc.xml) for a custom Linux ARM64 PLC in CODESYS 3.5.21.20? CODESYS Forge talk (Post)
I’m trying to integrate a custom PLC into CODESYS so that it appears under the Device section. From what I understand, this requires a .devdesc.xml device descriptor file. I attempted to create the XML manually, but whenever I try to install it in order to generate a .package file, CODESYS crashes. CODESYS version: 3.5.21.20 Target PLC: Linux ARM64–based My questions are: Is there an official or easier way to generate a valid .devdesc.xml file for a custom PLC? Are there tools, templates, or examples that can help ensure the XML is structured correctly and won’t cause crashes? For Linux ARM64 targets specifically, is there a recommended starting point (e.g., modifying an existing device descriptor)? Any guidance or best practices for creating and packaging custom device descriptors would be greatly appreciated.
Last updated: 2025-10-06

Post by ranadheer on Implementation of IEC-104 CODESYS Forge talk (Post)
Hi Everyone, As we didn't have client for IEC - 104 - only server server is available , so because of that we are trying to make establish the communication between the external simulator as a Client and codesys itself as a server. We are looking for the variable behavior from CODESYS has to change according to the message triggered by the CLIENT (we are using simulator Application like Redisant). We are able to see the log data as the status of triggering the SCS from Client received to the Log data of the codesys device(attached screen shot of it) and in simulator panel we had set the details to trigger the data from Redisant to Codesys. Current Status: The project builds and runs successfully, but I need guidance on how to connect this to an external IEC-104 simulator for testing and visualization by using demo mode.
Last updated: 2025-10-14

Post by preimesbergert on Raspberry Pi 4 B HW 1.5 Codesys control 4.10.0 stopps after a few seconds CODESYS Forge talk (Post)
Wanted to play a bit with a raspberry Pi 4 Model B HW 1.5 and Codesys. Regardless of the image (tried 32bit / 64bit version from Raspberry Pi Imager) and with all tested Codesys Control versions (4.2.0, 4.8.0, 4.10.0) and regardless if single core / multicore / 64 bit variant, always is the runtime stopped after about 30sec with the nice message: ooops... this runtime was built for RASPBERRYPI. Hardware version or firmware version not supported! (-7, 0x00000BB8, 0xFFFFFFFB) Whats wrong with it?!?!? I read a lot about the issue in topics from 2020-2021 but it always was stated with new Codesys control version issue will be fixed (4.4 for example) but still it is there.
Last updated: 2023-12-21

Post by preimesbergert on Raspberry Pi 4 B HW 1.5 Codesys control 4.10.0 stopps after a few seconds CODESYS Forge talk (Post)
Wanted to play a bit with a raspberry Pi 4 Model B HW 1.5 and Codesys. Regardless of the image (tried 32bit / 64bit version from Raspberry Pi Imager) and with all tested Codesys Control versions (4.2.0, 4.8.0, 4.10.0) and regardless if single core / multicore / 64 bit variant, always is the runtime stopped after about 30sec with the nice message: ooops... this runtime was built for RASPBERRYPI. Hardware version or firmware version not supported! (-7, 0x00000BB8, 0xFFFFFFFB) Whats wrong with it?!?!? I read a lot about the issue in topics from 2020-2021 but it always was stated with new Codesys control version issue will be fixed (4.4 for example) but still it is there.
Last updated: 2023-12-21

Post by cedriclee on RaspberryPI reconnection error CODESYS Forge talk (Post)
"Hello, I'm Cedric Lee, a PLC engineer based in Korea. I'm reaching out about an ongoing issue with the connection when attempting to control Beckhoff modules using Raspberry Pi with CODESYS for the first time. I use CODESYS to target the Raspberry Pi's IP, install version 4.10.0.0 of the CODESYS Runtime Package, and upon pressing Start in the Runtime, the target connects to the Raspberry Pi. However, within about a minute, an error window appears, stating 'no connection to the device. please rescan your network,' leading to the disconnection of the target. This cycle repeats. I've attached some pictures for your reference. I'm using CODESYS Development System V3, Raspberry Pi 4 Model B (installed as 64-bit), and Beckhoff EK1100 modules. If anyone has a solution to this issue, please help. Your assistance is greatly appreciated."
Last updated: 2024-01-11

Post by idalu on Profinet PN_Controller Issue, Network Adapter CODESYS Forge talk (Post)
i have a problem with Profinet on my project. I'm using Codesys RTE 3.5.19.50. When i download program to controller the ethernet is ok, PN_Controller is ok but every device i'm trying to connect is red with error "DCP no RealStationName". When i'm trying to Scan for Devices on PN_Controller there are no devices found. I have installed Codesys driver CmpEt1000Drv to my network adapter (i'm sure it is right intel pro 1000 model). I have noticed that when i installed codesys driver i'm no longer able to ping this network adapter (i can ping it when intel driver is installed). On my previous projects with runetimes i can ping it even with codesys driver installed. I have also tried to do downgrade of everything to version 3.5.19.20 and it not helped.
Last updated: 2024-01-17

Post by riccardo on Web Browser special tools errors CODESYS Forge talk (Post)
Goodmoning everyone, I hope a codesys tecnichian will see this post. I serched on the forum and I found many topic about this tool but very few reaplies. I am tring to use the Web Browser tool, but it doesn't seem to work properly. I put several links in several forms: https://google.com http://google.com/ http://www.google.com http://www.google.com/ http://www.studiojomega.it/ . . . https://192.168.1.101/u-os-app-codesys/application/visualization/webvisu.htm But I obtain always errors; mainly 400 and 404 and in the normal visu this message appears "www.Google.com has refuse the connection". Is the codesys browser able to work as every other browser or has it some limitation? There is some particular precaution to consider when I pass the link to the codesys browser? Thanks in advance, Riccardo
Last updated: 2024-02-29

Post by valenting on Runtime not working on raspberry pi Bullseye CODESYS Forge talk (Post)
Hello I have a problem with Codesys on Raspberry pi with Bullseye The device is not recognized as a Raspberry pi, as I get this error : ooops... this runtime was built for RASPBERRYPI. Hardware version or firmware version not supported! (-18, 0x00000BB8, 0xFFFFFFFB) I'm running Codesys on a compute module 4S with Raspbian GNU/Linux 11 (bullseye), my kernel version is Linux 5.10.90-v7l+ Codesys version is the latest, released last week (4.11.0.0, CODESYS Control V3.5.19.61 for ARM-32Bit - build Feb 22 2024) I know it works on the same device if I use Raspbian 10 (Buster) with Linux 5.4.81-v7l+ kernel, but for some other reasons I have to use Bullseye. What can I do ?
Last updated: 2024-03-01

Post by khaledkhalil on Import OPC UA model to Codesys CODESYS Forge talk (Post)
I have added a models in SiOME which a software to design nodes and add instances. and created a resultant xml file. I tried to import the xml file to Codesys through OPC UA information model Repository the problem i don't know how to view my objects which i have designed. and map it to my PLC to make viewable on my server UaExpert. I watched the tutorial video https://youtu.be/aJhzN3Uk-Do?feature=shared. But it only give you how to add the Information model, and my resultant model doesn't have information type. So how in Codesys i can view a model which i have designed in SiOME and mapped my instances (Objects, Variable or methods) with my Variables in PLC I saw people do it in Tia Portal or other Software, but i have no clue how to do it on CODESYS
Last updated: 2024-03-12

Post by mp9876 on Problems with simulation in Window 10 CODESYS Forge talk (Post)
Hi Automa, it seems the solution you were bringing up on 2022-04-06 could really help me as I did not remember the password I initially set. My problem though is that I am using Codesys Control Win V3.5 SP19/60 (64 bit) and I cannot locate any of the files you listed up there. I have been looking inside folder: C:\Program Files\CODESYS 3.5.19.60\CODESYS\ and they appear not to be present at all neither in the CODESYS folder or any sub-folders. Uninstalling and re-installing unfortunately does not do the trick. Any idea how I could get out of the ditch on this issue ? Anyone else maybe ? Thanks
Last updated: 2024-03-18

Post by hafizapik99 on Webvisu not showing Codesys V3.5 SP13 Patch 2. CODESYS Forge talk (Post)
Hello, I am using a Hitachi Micro EHV+ for a small project, and I wanted to have a Web visu, done with Codesys V3.5 SP13 Patch 2. I test the Visu screen and it works well in Codesys, but I get a blank page when i enter the web visu in a browser. Here is the setting under web visualization: Update rate (ms): 5000 Default communication size: 100000 Under Visu_Task tab: Priority: 3 The Visu_Task interval is set to 2500ms I'm using Google chrome with the latest update, the Javascript is enabled with HTML5. Any advice?
Last updated: 2024-04-06

Post by timvh on Codesys complains about matching versions CODESYS Forge talk (Post)
Open the CODESYS Installer. Create an export file from your current PC from your current version. Then on the other PC Open the installer and install a new version based on the same essentials version, but additionally select the export file which you have created on the first PC. Or just install (import) it within the already existing version. For the installer, you can install it from: https://store.codesys.com/en/codesys-installer.html For help see: https://content.helpme-codesys.com/en/CODESYS%20Installer/_inst_install_setups_and_addons.html On PC 1, save the project as projectarchive (which will then include all the libraries and devices). Then extract this projectarchive on PC 2.
Last updated: 2025-12-15

Post by cdutz on Problems connecting to Codesys 4.9.0.0 runtime on my Wago PFC200 CODESYS Forge talk (Post)
Hi all. I am currently struggling to get my Wago PFC200 running the Codesys Runtime in version 4.9.0.0 working. I am using Codesys V3.5SP19. I updated the PFC200 to the firmware version 04.01.10(23) after having tried the latest version (04.03.03(25) from Wago and not being able to start the runtime. After reading version 23 was needed, I changed to that and at least was able to have it start the codesys runtime. I also installed the "Codesys Control for PFC200 SL 4.9.0.0" plugin for Codesys to install the Codesys runtime in version 4.9.0.0 as well as update the Gateway on the device. While I seem to be able to connect to the gateway on the PLC (the dot is green) and when doing a scan, I do now find my PFC200, which is a huge improvement to before, where with firmware version 25 it just failed to start the runtime and I never found any device when doing a scan. Unfortunately I don't seem to be able to connect to the PLC in codesys. I logged in via SSH and changed the password and I can see that this password is correct as the stuff in the Codesys PFC200 tools tab only works if I use my changed password. And I used those credentials to update the installed Runtime version, which the log claimed to have worked fine. Now whenever I try to connect to the device found in the scan, I get a authentication pop-up with empy device name, device address: 000A. As User I use "root" and as password the password that I changed it to. As a response I just get "Ungültige Benutzerauthentifizierung auf dem Gerät" (Eng. probably something like "Invalid user authentication on the device". What could I be doing wrong? Admittedly I'm a bit lost here :-/ Chris
Last updated: 2023-08-26

Post by tariq on Using Hilscher CIFX Cards as EtherCAT Masters in CODESYS CODESYS Forge talk (Post)
Dear Codesys Support Team, I hope this message finds you well. I am currently working on a project that involves using a Hilscher CIFX card to act as an EtherCAT master within the CODESYS environment. Despite following the available documentation and setup guides, I have encountered some challenges and require assistance to ensure proper configuration and operation. Questions: 1- Could you please confirm if the Hilscher CIFX card is supported as an EtherCAT master in CODESYS? If so, are there specific drivers or configuration files that need to be installed? 2- Are there detailed setup guides or example projects available that demonstrate the integration of Hilscher CIFX cards with CODESYS for EtherCAT communication? 3- Is there any additional software or plugins required for ensuring seamless communication between the CIFX card and the EtherCAT slaves within CODESYS? Your support and guidance on these matters would be greatly appreciated, as it is crucial for the success of our project. Thank you for your time and assistance. I look forward to your prompt response. Best regards, TB
Last updated: 2024-07-02

Post by aliazzz on Unable to deploy Virtual Control SL on ARM64 (Raspberry Pi5) CODESYS Forge talk (Post)
Hi, I have successfully deployed "Virtual Control SL" on a few x86/64 machines now. However, I'd now like to deploy this to a Raspberry Pi (ARM64). To do this I prepared the Raspberry Pi5 with the following prereq's; * Minimal PREEMPT Debian * Latest Bootfirmware * full SSH access via non-root account * Podman * RedHat Cockpit with CODESYS LicensServer plugin up and running However, I can't seem to resolve copying the correct (deploy) Images as they wont show up in the CODESYS IDE I have added CODESYS Virtual Control for Linux SL and the CODESYS LicenseServer for Linux SL via the CODESYS installer on my DevBox. I open CODESYS > Tools > Deploy Control SL Next I enter the SSH targets IP and Credentials and for my RPi5 and it shows "Connected". In the next tab, Deployment, the dropdown box only shows one (1) image, which also is the incorrect CPU architecture. Only Virtual Control AMDx64 shows up (!?) while I expect to see the ARM64 based images for both Edge and Control. Has someone encountered this too? I'd like to hear other people experiences with Virtual Control deployment on ARM based architecture. attachment 1: AMD64 based deployment pulldown menu (correct images) attachment 2: ARM64 based deployment pulldown menu (incorrect images) regards,
Last updated: 2024-07-28

Post by rossanoparis on Clarifications regarding the appropriate runtime system to use CODESYS Forge talk (Post)
Hallo all I would appreciate some clarifications regarding the appropriate runtime system to use. I've been using 'KUNBUS CPUs' and 'CODESYS Control for Raspberry Pi MC SL' for the last 4 years. Recently, there have been some changes in the CODESYS licensing policy. [ https://store.codesys.com/en/howto_applicationbasedlicenses ] My questions are mainly two: 1) If I need to start a new project using 'KUNBUS CPUs', which is the correct runtime system to use. 2) Old projects built using 'CODESYS Control for Raspberry Pi MC SL' should be updated to another RT system? Current RT systems ... a)CODESYS Control for Raspberry Pi MC SL b)CODESYS Control for Linux ARM SL c)CODESYS Virtual Control SL May I count on receiving an explanation to understand the differences among the runtime systems listed above? A detailed and well-organized answer would be greatly appreciated. Kind regards Rossano
Last updated: 2024-09-23

Post by faceplant on Comparison via CLI is broken CODESYS Forge talk (Post)
Hello! I am trying to compare 2 projects via the --compare CLI option. In the docs for the --compare option, it describes the usage as .\CODESYS.exe --compare "project path 1" "project path 2". I store my projects in WSL2 on my windows machine. Since CODESYS is happy to open those projects via a path like \\wsl.localhost\home\project.project. So, to compare, I use the command .\CODESYS.exe --compare "\\wsl.localhost\home\prog1.project" "\\wsl.localhost\home\prog2.project". This results in CODESYS just opening the project and starting, not comparing the two projects. No errors are thrown, and I know the paths are correct since I can open both independently in CODESYS, and I can compare them manually through the CODESYS UI. I have also tried moving my projects to the Windows 11 OS and still have the same issue. CODESYS opens the project and does not actually compare them. I am using CODESYS profile v3.5 sp20 patch 1. What is the correct way to compare 2 projects using the --compare CLI option?
Last updated: 2024-12-18