Post by eschwellinger on CODESYS Control Raspberry Pi mit Servotreiber T6 von StepperOnline
CODESYS Forge
talk
(Post)
Ist das RS232 oder RS485? Bei RS485 muss der Adaper also dein USB/Serial die Senderichtung in Hardware machen und das unterstützen. Abschlusswiederstände?
Last updated: 2024-06-01
Post by paulg on CODESYSControl_User.cfg - link to documentation?
CODESYS Forge
talk
(Post)
Is there somewhere in the Codesys help files that generally details what configuration options are available for this file, and what details it logs regarding the configuration file? Or is that going to differ by libraries being used? Thanks!
Last updated: 2024-06-11
Post by sahil-koul on Touch Probe Continuous Trigger
CODESYS Forge
talk
(Post)
Hi everyone. Can anyone tell how to do continuous trigger function of probe in codesys and change scaling of servo online in program
Last updated: 2024-06-16
Post by jinlee on Camera Feed (CCTV)
CODESYS Forge
talk
(Post)
Hi everyone, Can someone share some projects or samples with me regarding implementing the camera as a CCTV in Codesys 3.5 visualisation ? Kind regards, Jin.
Last updated: 2024-06-17
Post by eschwellinger on Cant login to Rpi4 but can see it in codesys communications settings.
CODESYS Forge
talk
(Post)
your device in the device tree is Pi 64 online you have Pi MC (32bit) - update device in the device tree to Pi MC then it will work.
Last updated: 2024-06-23
Post by s1mon on Two OneWireMaster on one Raspberry PI 5
CODESYS Forge
talk
(Post)
yes sure. Thx for your support! This is the Codesys project stripped down only to my EtherCat and OneWire Configuration. The Project now contains only one OneWire Master on GPIO4.
Last updated: 2025-10-20
Post by jtebokkel on VAR_GENERIC unknown token
CODESYS Forge
talk
(Post)
The help says VAR_GENERIC exists, but trying to use it in 3.5.21.30 results in a unknown token error. https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_vartypes_var_generic_constant.html Did this feature get removed or is there something else that needs to be done to enable using generic function blocks?
Last updated: 2025-10-21
Post by alimans on Unrecoverable SoftMotion state after switch to PreOp
CODESYS Forge
talk
(Post)
Hi Kim, Hi eschwellinger, how you could solve the problem? I am using Codesys V3.5.19.60 and I still have the same problem. It will work only after a warm/cold restart. Thank you in advance for your kind help.
Last updated: 2025-10-22
Post by jeroenaero on Difference between using OPCUA symbol configuration and OPCUA Server object
CODESYS Forge
talk
(Post)
Hi, What is exactly the difference between using symbol configuration as OPCUA server or using the Codesys object OPCUA server? What are the advantages and disadvantages of using symbol configuration and OPCUA server object. Please let me know
Last updated: 2025-10-30
Post by eschwellinger on EtherCAT status errors
CODESYS Forge
talk
(Post)
Setting IRQ priorities using shell commands irq-list and irq-set-prio for the network adapter which is used for Ethercat. This is here: https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_performance_optimization_linux.html
Last updated: 2025-11-25
Post by micik on Error, visualisation property handling, VISU_USEPROPERTYINFO
CODESYS Forge
talk
(Post)
@davidking, can you be more specific about where exactly "Compiler Defines" is located. I'm using Codesys v3.5 SP21 Patch2 and cannot find this Compiler Defines option. In the menu Project -> Project Settings there are Compiler options and Compiler warnings, but that is not it.
Last updated: 2025-11-26
Post by durallymax on How to use MQTT in CODESYS Control Win V3
CODESYS Forge
talk
(Post)
With the IIoT library/license or the one provided by the hardware OEM. Several examples online of how to use the MQTT Client SL library.
Last updated: 2025-12-12
Post by kenth1973 on MC_Phasing state explenation
CODESYS Forge
talk
(Post)
Hi George - ok thanks - but who created this FB in the first place? Could you lead me to the creator company? Is CODESYS not the old S3 that created this FB? :-)
Last updated: 2025-12-17
Post by aniket-b on Scara3 kinematic robot error
CODESYS Forge
talk
(Post)
It is Moons PLC which uses Codesys IDE. https://www.moonsindustries.com/series/mca6-medium-motion-plc-a150102 This has Realtime capability using Linux with preempt
Last updated: 2025-12-29
Post by baott569 on CODESYS OPC UA Security: HMI Client Not Receiving Server Certificate
CODESYS Forge
talk
(Post)
Hello everyone, I am currently using OPC UA in CODESYS with the security mode BASIC256SHA256 – Signed and Encrypted. The OPC UA Server is running on an RTE CX device, and the HMI is running on another computer. I have reviewed many CODESYS documents and successfully established communication when the security mode is set to None with Anonymous login. However, when security is enabled, the server does not provide its certificate for the CODESYS HMI client to trust. Interestingly, the client can send its certificate to the server, and UAExpert works normally, but the CODESYS HMI client does not receive the server certificate. Can anyone help clarify what I might be missing? I have been stuck on this issue for three days. If I missed or misconfigured any step, please let me know. I believe I am stuck at step 15 in the following CODESYS guide: Encrypting the Communication of a Data Source OPC UA Client https://content.helpme-codesys.com/en/CODESYS%20Communication/_cds_encrypt_communication_data_sources_opc_ua_client.html Thank you very much.
Last updated: 5 days ago
Post by timvh on High resolution displays with 150% scaling causes CodeSys IDE to be blurry
CODESYS Forge
talk
(Post)
Instead of using scaling of 150%, can't you adjust your diplay resolution (Windows+i keys, then go to System > Display settings)?
Last updated: 4 days ago
Post by emmieturner on Which Lib to use, connect to a socket with URL instead of IP address
CODESYS Forge
talk
(Post)
hi, maybe Net Base Services https://forge.codesys.com/prj/codesys-example/nbs/home/Home/ https://geometrydashlite.online Thank for sharing
Last updated: 2025-11-16
Post by davidbo on *EXCEPTION* [ProsessorLoadWatchdog] codesys 3.5.11.40
CODESYS Forge
talk
(Post)
Under Application->"Task Configuration" you can find your task double click on that and you will see a fane to the right. You find the watchdog enable switch it off or increase the time
Last updated: 2025-11-17
Post by tristan on Textfield display problem
CODESYS Forge
talk
(Post)
Hello Tim, I am using CODESYS Visu V4.8.1.0. It works when I turn off the "Support client animation and overlay of native elements". But if I do that, dialog box moving and other options are also disabled so it is a bit problematic. Thank you for helping.
Last updated: 2025-11-27
Post by somlioy on Non-formal invocation of function blocks in CODESYS
CODESYS Forge
talk
(Post)
No that is not possible for function blocks, although it is possible to that with methods and functions as you see in your second pic.
Last updated: 2025-12-05
Post by danamocca on SM3_CNC Sentence modifier
CODESYS Forge
talk
(Post)
Hi! Does anyone have an example of ReadNCFile2 with Sentence Modifier? Current examples on CODESYS help page are outdated and have a lot of errors, like "SMC_CNC_LibParams.MAX_SUBPROGRAM_NESTING_DEPTH" calls, which are not present in current version of SMC3_CNC library.
Last updated: 2025-12-25
Post by karsonsv on CODESYS HMI and 2 monitors
CODESYS Forge
talk
(Post)
I need open visualization on two monitors (every monitor 19201080). In TargetVisu i configure Scaling Options as Fixed 38401080. But visualization open onli main monitor and onli half.
Last updated: 2026-01-02
Post by baott569 on CODESYS OPC UA Security: HMI Client Not Receiving Server Certificate
CODESYS Forge
talk
(Post)
Hello everyone, I am currently using OPC UA in CODESYS with the security mode BASIC256SHA256 – Signed and Encrypted. The OPC UA Server is running on an RTE CX device, and the HMI is running on another computer. I have reviewed many CODESYS documents and successfully established communication when the security mode is set to None with Anonymous login. However, when security is enabled, the server does not provide its certificate for the CODESYS HMI client to trust. Interestingly, the client can send its certificate to the server, and UAExpert works normally, but the CODESYS HMI client does not receive the server certificate. Can anyone help clarify what I might be missing? I have been stuck on this issue for three days. If I missed or misconfigured any step, please let me know. I believe I am stuck at step 15 in the following CODESYS guide: Encrypting the Communication of a Data Source OPC UA Client https://content.helpme-codesys.com/en/CODESYS%20Communication/_cds_encrypt_communication_data_sources_opc_ua_client.html Thank you very much.
Last updated: 5 days ago
Post by alex-at-xana on EThercat Dynamic configuration
CODESYS Forge
talk
(Post)
Hi Everyone, For a fast monitoring system I am using Ethercat oversampling and timestamping inputs. As the customers has a lot of different configurations out in the field, we went for a dynamic Ethercat configuration. Already got the whole detection chain working but now I am stuck since two days in debugging the configuration. Here are my quesitons: I extended the dynamic config example for the EL3632 16#0E303052: //EL3632 pSlave^.SetDCSettings(TRUE,TRUE,80,80,TRUE,4000,0,0); pSlave^.AddSyncManager(16#1000,128,16#26,TRUE,3); pSlave^.AddSyncManager(16#1080,128,16#22,TRUE,2); pSlave^.AddSyncManager(16#1100,0,16#4,TRUE,1); pSlave^.AddSyncManager(16#1110,214,16#20,TRUE,0); pSlave^.AddFMMU(0,214,0,7,16#1110,0,1,1); pSlave^.AddFMMU(0,1,0,0,16#80D,0,1,1); xKnown := TRUE; This leads to a PLL Error for these devices. I double and triple checked the configuraton, but cannot find the issue. There seems to be one difference: the config dialog creates a startup parameter: 16#10F3:16#05, Name: Command_0, Value:0. Bitlen: 16, Stop on fault: false, jumpt at fault: false: next line: 0 a) I do not find information on how to set this in my code. Can you help me there? b) Without trying to set the value, I get a PLL error for these devices in the master log. Is the config wrong? c) Do I need to set the Master to Autoconfigure or Manual? I used autoconfigure for my tests. The stack creates input data addresses for the slaves input data range (pSlaves[i].InputData) which are different from those created when I use the Engineering tools dialogs to configure Ethercat. Specifically, the addresses seem to be aligned at 16 byte boundaries when they are created using the engineering tool, but may appear at uneven addresses when I use the script in dynamic config. I did not try to access ULINT at uneven addresses yet, but I am suspecting this may be a problem. Do I need to manually align the addresses ? Any help is appreciated...
Last updated: 2024-09-10
Post by george32 on Readable IO names
CODESYS Forge
talk
(Post)
Hello Folks, I have a quite basic understanding of how PLC programming works. However I keep getting stuck on 1 problem I could not get my head around. The problem is as follow: I have a PLC with 60 IO (20 inputs, 40 outputs). Each IO is defined as a function block. Furthermore I have an external IO card connected trough a CanBus connection. This IO card has 4 analog input channels (USINT), 4 digital inputs (Bool) and 4, digital outputs (Bool) Because I have 2 different components which both has data have I made 4 arrays to store the data off every component in one variable. PLC_Input: Array [1..20] of BOOL; PLC_Output: Array [1..40] of BOOL IOCard_Input: Array [1..8] of BOOL IOCard_Output: Array [1..4] of BOOL Because the control and reading of the different in and outputs is done by a TCP connection I want to use some kind of enumeration or struct to give each index a name so that my main would be a little bit more readable instead of all the magic numbers. Also this would make my program more dynamic for the furter in case I need to changes some in the IO nummers. For example: pump is placed on the fysical terminal strip number place 54, which is the 3th output of the IO card in the program: if I am sending a message with value 54 I would like to control IOCard_Output[3]. If there is a solution or methode to get this done, I can eventually do the following in my main program: IOCard_Output[Pump]. I have tried the following: IOCard_Output[Pump - 51] with an enumration but this keeps raising an error I hope some of you could help me further with this problem. In gross lines: I want to couple all the different IO to a more readable name and this readable name should control the right Array index Thanks in advance, George
Last updated: 2024-09-26