Post by kporter on SoftMotion, accessing PDO input data via object ref/pointer
CODESYS Forge
talk
(Post)
It looks like one can use the OutputData and InputData members of ETCSlaveStack: https://content.helpme-codesys.com/en/libs/EtherCATStack/4.2.0.0/EtherCATStack/ETCSlaveStack.html
Last updated: 2025-10-29
Post by jeroenaero on Difference between using OPCUA symbol configuration and OPCUA Server object
CODESYS Forge
talk
(Post)
Hi, What is exactly the difference between using symbol configuration as OPCUA server or using the Codesys object OPCUA server? What are the advantages and disadvantages of using symbol configuration and OPCUA server object. Please let me know
Last updated: 2025-10-30
Post by kalmeyer on Stepper motor control with (SM_Drive_RaspStepper_direct)
CODESYS Forge
talk
(Post)
Is there perhaps a place where I can see examples of programming with different instructions? This would be a great help. Maybe there are some places where ready-made programs are posted that can be downloaded and tested? /Klaus
Last updated: 2025-11-10
Post by nano on conformation about the CODESYS Extends SL and CODESYS SDK
CODESYS Forge
talk
(Post)
as an oem i can tell you, extension sl isn't the sdk. its more an hard restricted part of it with much missing parts. why u may ask this?
Last updated: 2025-11-11
Post by davidbo on What is the prerequisites for a Raspberry Pi to work with SysSockSetIpAddressAndNetMask()
CODESYS Forge
talk
(Post)
I have now and it works. I had the idea that it had something to do with codesyscontrol.cfg, but where can I find a description of all the things you can set in codesyscontrol.cfg and its syntax?
Last updated: 2025-11-12
Post by jonasz on Deploy LicenseServer for Linux SL
CODESYS Forge
talk
(Post)
After carefully studying the documentation, I have a question: is a second hardware-independent time source required for the correct operation of the VirtualSafety system?
Last updated: 2025-11-17
Post by tristan on Textfield display problem
CODESYS Forge
talk
(Post)
Hello everyone, I have a little problem with textfield display. When I put a solid backgroud, no problem. But when I put it to invisible, some strange things appears with the text. Do you have this kind of issues ? Thanks a lot, Tristan
Last updated: 2025-11-20
Post by jonasz on Deploy LicenseServer for Linux SL
CODESYS Forge
talk
(Post)
Thank you for your response. Is there documentation for the commands? I spent a lot of time trying to figure this out. I have a potato computer at home, so I'll have to test this later.
Last updated: 2025-11-21
Post by timvh on Access Violation sherd memory
CODESYS Forge
talk
(Post)
Maybe it is better to use Interfaces to access the objects instead of pointers. But besides that, is "read_obj_ptr" a method? If yes, you need to call it, so add brackets behind the method call: read_obj_ptr();
Last updated: 2025-11-27
Post by timvh on Error: C0138: No matching 'FB_Init' method found for instantiation of VisuClientObjectMgr
CODESYS Forge
talk
(Post)
Maybe check: - The library manager, are you maybe missing some libraries - Tools - CODESYS installer: update the CODESYS Visualization and Visualization support - Project - Project environment: maybe you need to update the visualization profile
Last updated: 2025-11-27
Post by mbart on VAR_INFO from inside of a FB to get info on the instance.
CODESYS Forge
talk
(Post)
I experienced the same problem: using __VARINFO is working only in PRG context, while it crashes if used inside Function Blocks. I would really appreciate if they would fix this issue
Last updated: 2025-12-04
Post by durallymax on How to use MQTT in CODESYS Control Win V3
CODESYS Forge
talk
(Post)
With the IIoT library/license or the one provided by the hardware OEM. Several examples online of how to use the MQTT Client SL library.
Last updated: 2025-12-12
Post by gseidel on MC_Phasing state explenation
CODESYS Forge
talk
(Post)
Hi kenth1973, it is not a matter of who created the function block. It is just that we don't have, and don't provide, documentation about internal implementation details... Hope you can understand that, Georg
Last updated: 6 days ago
Post by reinier-geers on Data to server
CODESYS Forge
talk
(Post)
HI, i want to copy data to a server of a costumor. Whats the easy way ? contoller is V20p5 but also 2 are V9.2
Last updated: 2025-11-11
Post by mariusz997 on Visualisation - internal error
CODESYS Forge
talk
(Post)
Hi - problem solved. I had 3 version of codesys on system and they didn't like each other. After uninstall all and install again only one version now everything is OK
Last updated: 2025-11-12
Post by emmieturner on Which Lib to use, connect to a socket with URL instead of IP address
CODESYS Forge
talk
(Post)
hi, maybe Net Base Services https://forge.codesys.com/prj/codesys-example/nbs/home/Home/ https://geometrydashlite.online Thank for sharing
Last updated: 2025-11-16
Post by grepoo on DataSource CodesysApp V3
CODESYS Forge
talk
(Post)
Hi, trying to create a datasource in appV3 but it returns error code 259 (not nearer specified) everytime, no matter the device i am using. Any idea of what it might signify ?
Last updated: 2025-11-19
Post by seler on Custom button with output status
CODESYS Forge
talk
(Post)
I did some work around by adding IN switch on top of OUT bulb picture(SwitchImage) and setting IN switch button to invisible but this is not quite elegant. How to combine it to one visu element?
Last updated: 2025-11-20
Post by tristan on Textfield display problem
CODESYS Forge
talk
(Post)
Hello Tim, I am using CODESYS Visu V4.8.1.0. It works when I turn off the "Support client animation and overlay of native elements". But if I do that, dialog box moving and other options are also disabled so it is a bit problematic. Thank you for helping.
Last updated: 2025-11-27
Post by mr-ege on Error: C0138: No matching 'FB_Init' method found for instantiation of VisuClientObjectMgr
CODESYS Forge
talk
(Post)
I have tried these steps, but it still does not work. What should I do? I'm stuck on this error. I cannot design the HMI, I need help.
Last updated: 2025-11-27
Post by somlioy on Non-formal invocation of function blocks in CODESYS
CODESYS Forge
talk
(Post)
No that is not possible for function blocks, although it is possible to that with methods and functions as you see in your second pic.
Last updated: 2025-12-05
Post by patrik on Wish: CODESYSControl.cfg - again
CODESYS Forge
talk
(Post)
Really good post. I hope that it gets seen by CoDeSys staff. I often find the documentation lacking when it comes to using CoDeSys in more complex ways. If using standard "basic PLC functionality", then it's fine and functions are documented in a sufficient way. Once you go outside of that bubble then I find the documentation not enough. CODESYSControl.cfg is a good example of this. And why isn't more of this integrated in the IDE. like changing port of the webserver. Why is it hidden in this file and not accessible through the IDE. It feels like a layer of complexity purposely left in so you don't change it if you don't know what you are doing. Like the argument is if you have the know-how to find the file you have the know-how to edit it. I find the documentation lacking when it comes to more complex libraries too. Like the element collections library. there is parameters I still don't quite know what they do. I can't find any documentation about them. There is an example project to download from CoDeSys so you can see how you are supposed to set your factories up. I leave some parameters like it is in the example. Should I? I don't know. Does it work. Yes. But I could perhaps create memory leaks if I get something wrong and I don't see that until way later. In the create method of your element factory you have a function called __vfinit and you just have to accept that it works. Why can't I get insight in what it does through documentation? Don't CoDeSys want us to know how these work so we can't use them to accidentally break something? I find the error logging lacking too. I've had the CoDeSys service crash but it doesn't say why. I've seen windows noticing the crash but no error code was sent or error message. Also in my current issue where the application fails to start after power outage. I can see in the log that it fails to load retain in the application as one log entry and application failing to start as another. But why? Why does loading the retain fail? give me more information! Is it just a skill issue with me? I don't know. If it is then I'd still want CoDeSys to step up their game when it comes to documentation. I'm sorry if a lot of frustration comes though in this post. I really like the product and what I can do with it compared to other PLC brands.
Last updated: 2024-11-21
Post by gmau on Station 'xyz': AR aborted by device (alarm.ind): AR consumer DHT expired
CODESYS Forge
talk
(Post)
Hello, I am writing to You with the problem of Profinet communication in my Codesys V2.5 SP21 project working on Codesys Control RTE V3 x64 device. I have implemented multiple Profinet devices in the network, the Profinet itself is configured properly, based on the hardware and software parameters of the industrial PC (Windows 10 IoT). My Profinet network contains such Profinet devices as a robot, IO-Link master with some devices on it, IO modules, safety, vision sensor (the configuration is attached to this topic). Once every few hours, sometimes more often, sometimes not even once a day, the error show up at one, two or a few random modules at the same time, every one is the same: "Station 'xyz': AR aborted by device (alarm.ind): AR consumer DHT expired". The communication is then lost with that module, but it is up instantly. It is not such a problem when it comes to regular IOs, but with safety or rotation table, it causes errors and machine stops. I have tried multiple solution based on any forum suggestions, manuals, etc., but it is still happening. Mabye when I turned on the Watchdog for this communication, it is happening less times, but still, I could not turning up the Watchdog parameters at the expense of cycle time of the process. The same is with Send Clock, Reduction and DHT. I have one of the ethernet port on the PC configured with CmpEt1000Drv driver. The card itself is Intel Ethernet Connection I219-LM. These devices are connected to one EKI-2728-NI-A Profinet switch (it was changed from the standard non Profinet one, but still nothing has changed). As I said ealier, I am attaching all the configurations for each device and the communication itself - if any of You had the same problems or have any ideas what could be the cause, I would be much gratefull for any help. For now I am out of ideas, if You have any additional question, please ask. Sincerely, PF
Last updated: 2025-09-04
Post by smeitink on Timeout Error in Modbus Communication with WAGO PFC200 and iEM2050 Meter using 750-652 Module
CODESYS Forge
talk
(Post)
Hi all, I'm looking for help with an issue I've come across while trying to facilitate Modbus communication between a WAGO PFC200 PLC using a 750-652 communication module and an iEM2050 Series Single Phase Energy Meter. I believe to have everything wired and setup correcty, but I keep running into a "Error time out" message, and by now I don't really know what else to try. My setup is as follows: A PFC200 Wago PLC, which has 2 750-652 Serial Interfaces extension modules connected to its field bus. I'm using one of these to talk to a Schneider iEM2050 - kWh-meter over modbus. I have connected terminal 23 (A) of the iEM2050 to connector 6 (A) on the 750-652. I have connected terminal 24 (B) of the iEM2050 to connector 2 (B) of the 750-652. I'm using 200mm of twisted together wires to connected them both, and I have placed a 120 ohm resistor between A and B at both ends. I've attached relevant pinout images to this post. I then wrote a simple program that configures the Mobus port, as per the datasheet of the iEM2050. You can find an image of the relavent page attached to this post too. This is my program: PROGRAM PLC_PRG VAR Master: FbMbMasterSerial; xIsConnected: BOOL; xError: BOOL; iIndex: INT := 1; xTrigger: BOOL; utQuery : typMbQuery := ( bUnitId := 1, // The Modbus unit or slave address bFunctionCode := 4, // Function code for reading input registers uiReadAddress := 1829, // adress for the Power on off counter uiReadQuantity := 1 // Quantity of registers to read ); iStep: INT; oStatusModbus: WagoSysErrorBase.FbResult; utResponseModbus: typMbResponse; xConnect: BOOL := FALSE; delayTimer: TON; END_VAR Master( xConnect:= xConnect, I_Port:= _750_652_24_1, udiBaudrate:= 9600, usiDataBits:= 8, eParity:= WagoTypesCom.eTTYParity.Even, eStopBits:= WagoTypesCom.eTTYStopBits.One, eHandshake:= WagoTypesCom.eTTYHandshake.None, ePhysical:= WagoTypesCom.eTTYPhysicalLayer.RS485_HalfDuplex, xIsConnected=> xIsConnected, xError=> xError, oStatus=> oStatusModbus, eFrameType:= WagoAppPlcModbus.eMbFrameType.RTU, tTimeOut:= T#5S, utQuery:= utQuery, xTrigger:= xTrigger, utResponse:= utResponseModbus); delayTimer(IN := TRUE, PT := T#3S); // Use the Q output of the timer to set xConnect after the delay IF delayTimer.Q THEN xConnect := TRUE; END_IF CASE iStep OF 0: //Wacht totdat de master de poort geopend heeft IF xIsConnected THEN iStep := 1; END_IF 1: //Stuur request naar de slave xTrigger := TRUE; iStep := 2; 2: //Wacht totdat de master klaar is met het afhandelen van de request IF NOT xTrigger THEN iStep := 3; END_IF END_CASE The TON delay before opening the port is due to a an error I encountered when opening it straight away. This seems to be a bug, as described here. However, the TON solved that particular issue. I tried reading multiple registers, but like I said, I still always end up with the "Error time out". What else can I test or try at this point?
Last updated: 2024-02-24
Post by mubeta on Some 'pathetic' errors in SoftMotion program
CODESYS Forge
talk
(Post)
Yes, this is the error the sometimes show up. What make me crazy is the fact that it happens randomly and not each times. I know very well where the problem is, in wich one program row it's located. For each actions of the state machine I have all events recorded with log on text file. it is not problematic for me to find the application point of the fault, but I need to understand why occasionally and for no apparent reason, switching the state machine and thus changing the motion FB, sends the axis into failure (but only occasionally). For example, one case that is often problematic is the execution of the Axis Halt instruction. When, after a MoveAbosulte instruction this returns the event as 'done' and indeed the axis is in standstill, the state machine first sets the move instruction to FALSE, and the next cycle sets the Halt request to TRUE. Some of the time everything works out fine. Occasionally, however, in this exchange, the axis goes into fault, also losing the OPERATIONAL state. Meanwhile, I would like to understand why the motion FB instances must still be called even after the Execute is set to FALSE, especially in view of the fact that the next instruction is programmed to abort the previous one, with BufferMode set to 'Aborting'. All these unnecessary FB calls are an unnecessary overhead on the CPU anyway. Is there any precise rule about when to cease calling the various instances? (It should precisely be the 'done' status that says this one has finished its work).
Last updated: 2024-07-18
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.