Post by k2saki on CNC / G-Code streaming processing ( to start quickly in long G-Code File )
CODESYS Forge
talk
(Post)
Is it possible like G-Code streaming processing (like FANUC or SIEMENS DNC Function )? Or Does anyone know the tips for CODESYS Motion to start moving long Long G-Code File quickly? I have to wait long time after "Start" button to start moving, I have to wait finishing interpreting whole G-Code file, ( and I have to prepare huge buffer to store. ) Now, I'm working on my CNC Project using SMC_ReadNCFile2, and SMC_NcInterpreter to preprocess G-Code. I tried to set SMC_Interpolator.xExecute to true to Start while after SMC_NcInterpreter processed more 50-line of G-Code, but that not worked, I had to wait SMC_NcInterpreter processed all lines to start SMC_Interpolator. G-Code have about 2000 lines of XY of G01 (or more over.. ) of short segment that a CAM software has exploded from NURBS Curve.
Last updated: 2024-05-03
Post by sbrauns on Codemeter log error: API Error 200 (ENTRY NOT FOUND) occurred!
CODESYS Forge
talk
(Post)
Hi, I am using Codesyscontrol for linux 4.11 with an USB dongle with license. The log file from codemeter shows a constant error message which repeats every minute: Entry (6000437:8755) not found - Event WB0200 (ENTRY NOT FOUND), Request IP-Address local(IPV4) with UserLimit API Error 200 (ENTRY NOT FOUND) occurred! The log file from Codesyscontrol itself shows runtime licensed and I experience no other issues. But I am still concerned about the error message in the log file. Does anybody know what this is and how to fix it? thanks
Last updated: 2024-05-08
Post by wbj0t on connect IDE to plc that uses modem ppp
CODESYS Forge
talk
(Post)
Hello everyone! I have an PLC device that uses modem ppp connection to the internet with white IP. Device PPP connection with modem operator established, so I can connect to this device via SSH also within Codesys IDE (check version, info, etc...) BUT, I cant establish connection to this device in the device gateway options for application upload and debugging. How can I do this? Im trying set my device remote IP and port 11740, but, as I understand, it is wrong decision, because the next logic in this connection: local W10 service (Codesys Gateway) listen on 1217, then (some how) this service scanning local networks for seeking any local IP which listening on port 11740, and then connects and writes there. OR IM WRONG?:) W10 tool 'Test-NetConnection' with parameters 'ip -Port 11740' succeeded with True. Need some help, please :)
Last updated: 2024-05-21
Post by dhumphries on Rounding error in simple addition
CODESYS Forge
talk
(Post)
Thanks for the response, as I've thought about this problem over the last month I began to suspect this was a problem with not being able to exactly represent .1 as a 32 bit binary number. I think I've found a work around by making the number an integer, then dividing it by 10 and storing that value as a floating point number. There is still an issue with the value not being exact somewhere in the 8th or 9th decimal place, but because I'm incrementing an integer value then dividing it, the error doesn't compound.
Last updated: 2024-05-25
Post by robpqs on Program from one PLC to other WAGO 750-8204
CODESYS Forge
talk
(Post)
Hello, You use the WAGOUpload tool. You can download it on the download center of WAGO. Make a backup and restore it on the new device. (if can check the remanent data to copy the persistent variables if necessary) You can also use a SD card, go to the WBM copy it the image to the SD card and restart the other controller on the SD card. In the WBM, copy it back to the internal flash. If you contact your local Wago office, they will more than probably help you. There is also a WAGO forum. RP,
Last updated: 2024-05-27
Post by damian177 on CM4S GPIO's in Codesys
CODESYS Forge
talk
(Post)
Hi, I am running my application on device based on Compute Module 4S (Cortex-A72 (ARMv8) 64-bit ). On this device I installed RPi Runtime in 4.11.0.0 version. In my project I use device: Codesys Control for Raspberry Pi 64SL and my project works, but I actually do not have acces to all GPIO's , because GPIOs Compute Module is available only in 3.5.16.0 version and it doesn't work. Properly work GPIOs B+/Pi2 but using this device I do not have acces to all GPIO's in CM4S. Anyone of can tell me how add GPIOs Compute Module 4.11.0.0 to my project ?
Last updated: 2024-05-28
Post by viksym on Get text from textlist
CODESYS Forge
talk
(Post)
Does anybody know how to get a specific text from a text list within a program. Obviously it works in a visualization, but because I will have an HMI that has it's own system and I will have to send variables to this HMI via an OPC UA connection, I need to be able to get a text into a string. I tried using the VisuElems like this, but it only returns an empty "" and nothing else. IF trig THEN sText := VisuElems.cmpDynamictext.DynamicTextGetDefaultText(ADR(sTextList), ADR(sAlarmID))^; //sText := VisuElems.cmpDynamictext.DynamicTextGetText(ADR(sTextList), ADR(sAlarmID))^; trig := FALSE; END_IF Any help and idea is highly appreciated because I am getting desperate here.
Last updated: 2024-05-31
Post by kronlundo on Licensing info not available (WAGO PFC200 + Codesys V3)
CODESYS Forge
talk
(Post)
Hi! We're using a WAGO PFC200 for several projects towards the energy sector, and recently upgraded to CODESYS V3. We have the "IEC 60870-5-104 Server" package in a test program, and it works well with the package in DEMO mode. However, when we acquired a license for the "IEC 60870-5-104 Server" package and tried to add the license on the PFC200 through the license manager, we get an error (see attached file). It seems like there is no CmContainer on the device, does anyone have an idea on how to fix this? We've also contacted WAGO on this issue a while back with no feedback yet.
Last updated: 2024-06-10
Post by adaffern on Runtime on Raspberry pi5 stops after 15 seconds
CODESYS Forge
talk
(Post)
Hi Guys, I'm new to CODESYS on the pi and I'm struggling to get it working. My issue is that the runtime keeps stopping after approximately 15 seconds. I have installed the runtime package 4.11.0.0 on the pi, trying on both a 64 bit and 32 bit OS. Looking at old forums it all references the 4B and the fact they used 32 bit Debian bullseye (the last version of raspberry pi os) however the pi 5 doesn't offer this version when I try select it in the imager. Has anyone managed to get running using the pi 5? Any help would be greatly appreciated. Thanks, Adam
Last updated: 2024-06-10
Post by installwhat on C0077 on one machine but not another
CODESYS Forge
talk
(Post)
I have a version of codesys 3.5.16 on my local machine and a vm. The local machine has loads of codesys versions and libraries installed etc. I can open the FPosCR_Example_Project_SP16_patch1 project on my vm without any errors. On the local machine I get the error C0077: unknown type IoDrvEthercatLib.ETC_CO_SdoWrite. I can, on the local machine, declare a var of type IoDrvEthercatLib.ETC_CO_SdoWrite and include it in the code without adding an extra error. The problem only seems to affect the library. This is seems more an issue with my codesys set up rather than something with festo. I would like to know the possible causes. I understand most of the library manager features but it's not clear how to find the cause. Thanks
Last updated: 2024-06-11
Post by kthomas on Cant login to Rpi4 but can see it in codesys communications settings.
CODESYS Forge
talk
(Post)
I have been struggling for over a week to program my rapspberry pi 4 with codesys. I purchased the license. I installed the runtime and the gateway, and I can see the pi in the communication settings. But cannot log in. I have checked the status of the pi with sudo systemctl status codesyscontrol and it is running. I have enabled traffic to and from the pi with iptables and checked the logs and all looks good. I just cannot connect through the codesys ide. Can anyone help me before I lose my mind?
Last updated: 2024-06-22
Post by kthomas on Cant login to Rpi4 but can see it in codesys communications settings.
CODESYS Forge
talk
(Post)
I have been struggling for over a week to program my rapspberry pi 4 with codesys. I purchased the license. I installed the runtime and the gateway, and I can see the pi in the communication settings. But cannot log in. I have checked the status of the pi with sudo systemctl status codesyscontrol and it is running. I have enabled traffic to and from the pi with iptables and checked the logs and all looks good. I just cannot connect through the codesys ide. Can anyone help me before I lose my mind?
Last updated: 2024-06-22
Post by ron-rp on Errors with VisuUserManagement library
CODESYS Forge
talk
(Post)
Hi all, I've played a bit with the VisuUserManagement library, and some other security option in my project, and I started getting this error when logging in - see attached pic. something to do with a specific screen in the library - VUM_Login. Also, Codesys started to ask me to log in to the library when logging in, asking to log in as user of the groups Maintainer or Owner, which I dont know either users (attached pic). when I close the login screen and try to log in to the PLC again, everything works again until I close and open Codesys. I do use user and password to login to the PLC, and this login screen is fine I know the user and pass I setup. anyone know what did I do wrong here and how to fix it?
Last updated: 2024-06-25
Post by adaml on ScriptEngine - execute "Export -> Bootproject and firmware (SD Card)" from python
CODESYS Forge
talk
(Post)
Hi everybody, recently I was checking how many time consuming manual tasks I can perform with python scripts through ScriptEngine. I have in the project many devices and currently I export bootprojects for them by right clicking on Application, then go Export -> Bootproject and firmware (SD Card) and then point folder where files should be exported. It's fine if project has few devices, but I have some of them with over 30 devices and manual clicking like that is very time consuming. How can I do it with python script? So far I found "create_boot_application" method from Application object (taken by projects.primary.find('Application', True)) but it only generates .app and .crc file instead of full structure to store on SD card (FIRMWARE, USERDATA, SDCARD.INI, Version, Version.txt.sig). Should I use some method to control user interface? Best regards, Adam
Last updated: 2024-07-05
Post by naks on Change IP address from IEC code
CODESYS Forge
talk
(Post)
Hi, I'm working with wago 750-8212 controller. I want to change the IP address of the Ethernet adapter from webvisu. I have read some other threads in this forum and I have tried the following: Added the following text to the config file CODESYSControl.cfg: [SysSocket] Adapter.0.Name="br1" Adapter.0.EnableSetIpAndMask=1 Used the below code : IF xUpdateEthernet THEN Ethernet.Enable := FALSE; Reconfig ( xExecute := TRUE, itfNode := Ethernet, eError => ErrorReconfig, xBusy => xBusy, xDone => xDone, xError => xErrorReconfigure); IF Reconfig.xDone THEN ErrorCode := Ethernet.UpdateConfiguredIPSettings(IpAddress := NewIp, gateway := newGateway, subnetmask := newSubnetmask); END_IF IF Reconfig.xDone OR Reconfig.xError THEN reconfig(xExecute := FALSE); END_IF Ethernet.Enable := TRUE; Reconfig(xExecute := TRUE, itfNode := Ethernet ); END_IF I could change the IP address but when i restart my Controller then the IP address resets to the original, Is there anything I have missed, what else can i try ? Thank you in advance.
Last updated: 2024-07-08
Post by dekelec on The current baud rate could not be determined in CR0020 IFM with maintenance tool
CODESYS Forge
talk
(Post)
It could be a problem with the cable pinout on either side: 9 pin D-SUB connector (male) - PC side Pin Potential: 1 n.c. 2 RxD 3 TxD 4 n.c. 5 n.c. 6 GND 7 n.c. 8 n.c. 9 n.c. Shell Shield Check if TxD and RxD cross between pins 2 and 3 (what is the Recive signal/wire to one device it's a Transmit signal/wire for the othe device) or with COM port settings: Bits per second: 9600 Data bits: 8 Parity: None Stop bits: 1 Flow controll: None
Last updated: 2024-07-09
Post by vamsi on How to configure gateway for programming RPi 2B using Codesys
CODESYS Forge
talk
(Post)
I am using a Raspberry Pi 2B. Installed Codesys V3.5.20.1 64-bit and installed 'CODESYS Control for Raspberry PI 4.12.0.0' I am able to install the packages using the 'Update Raspberry Pi' option, but when I try to log into the RPi, in the Device tab it says 'Sacn fail. Please checl that the gateway is running and that its settings are correct'. My setup looks like this. I connected my RPi to my company LAN and also my laptop to company LAN (using HP Docking station). This setup worked when I installed 'CODESYS Control for Raspberry PI', but now I donot know how to configure the gateway. Could anyone please help me in finding what I have to enter in the gateway configuration? Thanks, Vamsi.
Last updated: 2024-07-10
Post by rcanfield on Code Coverage and Test Manager
CODESYS Forge
talk
(Post)
I am exploring the possibility of measuring test coverage using the Test Manager and Profiler tools. It appears there are some significant limitations. Has anyone been successful trying to use these tools? Here are my observed limitations. Am I misunderstanding anything? * Profiler only works for one "run cycle". Even warm resets will clear the coverage calculations. Thus, all tests would have to manually reset values when complete to prevent contamination to other tests. * It is not possible to see which statements were/weren't executed. One would have to use the flow control tool which cannot be used in conjunction with the Profiler, and must be viewed in realtime. * The profiler control cannot be automated and therefore must be executed through a manual procedure. Thank you!
Last updated: 2024-07-11
Post by rcanfield on Code Coverage and Test Manager
CODESYS Forge
talk
(Post)
I am exploring the possibility of measuring test coverage using the Test Manager and Profiler tools. It appears there are some significant limitations. Has anyone been successful trying to use these tools? Here are my observed limitations. Am I misunderstanding anything? * Profiler only works for one "run cycle". Even warm resets will clear the coverage calculations. Thus, all tests would have to manually reset values when complete to prevent contamination to other tests. * It is not possible to see which statements were/weren't executed. One would have to use the flow control tool which cannot be used in conjunction with the Profiler, and must be viewed in realtime. * The profiler control cannot be automated and therefore must be executed through a manual procedure. Thank you!
Last updated: 2024-07-11
Post by ucconversions on displaying all incoming CAN bus messages
CODESYS Forge
talk
(Post)
Hello Im using CAN API Im receiving CAN messages with no problem. below is my code. METHOD ProcessMessage VAR_IN_OUT ( Incoming message ) Message : CAN.RxMESSAGE; END_VAR VAR i: USINT; END_VAR recvCANid := Message.udiCanID; IF recvCANid = 16#18FF8247 THEN UserVarGlobal.g_countMsg_RPMset := UserVarGlobal.g_countMsg_RPMset + 1; FOR i := 0 TO 7 DO myDataFF82[i] := Message.abyData[i]; END_FOR END_IF but in this way I can only display CAN messages which I know its ID. I want to display all incoming CAN messages for example first incoming CAN message - I assign it into a variable Message1. second incoming CAN message - I assign it into a variable Message2. third incoming CAN message - I assign it into a variable Message3. Can you give me guidance? Thank you BR
Last updated: 2024-07-18
Post by mubeta on Reset problem with CMZ SD/SVM drive
CODESYS Forge
talk
(Post)
In a recent project with SoftMotion 4.15.0.0, where I integrated two SD drives from CMZ (from catalogue EDS and not imported), on CANopen bus, I found that the SoftMotion MC_Reset function does not reset the drive faults. Even if the drive is in fault, either on the device or on the drive at the CoDeSys level, the function does not reset, instead reporting the error code: no error to reset. Finally, I had to connect the reset bit of the ControlWord directly to a tag in my program. Something I never had to do on other drives: Lexium, etc. all reset simply with MC_Reset.
Last updated: 2024-07-24
Post by dawidr on Best practices for querying multiple MODBUS devices
CODESYS Forge
talk
(Post)
Hi! What are the best practices for querying multiple Modbus devices? Single PRG or maybe multiple PRG (so basically multiple thread) per each Modbus device. In my current implementation I'm using single PRG and I'm utilizing FbMbMasterMultiQuerySerial and WagoAppPlcModbus.FbDigitalTwinMbSlaveDevice in eCockpit with PFC200. I've the timer with 2 seconds delay there and it was working fine for single device. But now I have three Modbus devices and for two of them I need to run 2/3 queries to get data from all registers. I noticed that the delays for getting the data from the Modbus devices is much bigger right now.
Last updated: 2024-07-31
Post by paulpotat on Exclude traces when searching with ctrl+F
CODESYS Forge
talk
(Post)
Hello, I was wondering if there is a way in codesys to exclude the traces from the search when using the "ctrl+F" window ? That would be nice to improve the search functionnality when looking for a specific variable. Sometimes when I iterate through all occurences with the "find next" button, it opens the trace configuration window. I would expect to be able to close it and go to the next occurence with the "find next" button, but after closing the trace configuration window the search says it has reached the end of the scope (even if in reality there are other occurences of the variable elsewhere). I tried to enable / disable the "search up" checkbox but it's not changing anything. I hope somebody have insight on this, BR
Last updated: 2024-08-06
Post by installwhat on IDialogOpenedListener
CODESYS Forge
talk
(Post)
Why do you develop things like this? The workflow should be highly dependent on autocomplete, then if that's not super obvious browse to definition and everything is made clear possibly with the checking of a few types. The nature of how things are done makes me think these libraries aren't developed for general use and are actually internal or for partners. The example projects include objects that don't appear in autocomplete and then lead nowhere obvious when browsing. Do you consider developer workflow when creating these libraries? Are some libraries really for public use such as Visu Utils and others not? If so which? It's really hard to tell.
Last updated: 2024-08-06
Post by expertplas on No connection to opc server from codesys opc client
CODESYS Forge
talk
(Post)
Hello, we have aproblen to connect our CODESYS OPC Client to the OPC Server. We installed the client according the CODESYS manual. We can browse the server and variables can be linked to the PLC. I created a self signed certificate for the CmpOPCUAClent as described. The server has a cerificate also. I copied the certificates to the trusted zone of server and client. But when it comes to data exchange we get an error message. "Communication error in data source OPC UA Library. Error ID : 7001 German : "Kommunikatinsfehler inder Datenquelle OPC UA -Bibiothek. Es wurde kein genauer Fehler angegeben. Fehler ID : 7001" It semms that there is no cerificate exchange. We are working with CODESYS 3.5 SP19 Patch 5. Can anyone here say something about this error or has an idea for a solution? Thanks.
Last updated: 2024-08-19