Post by wbj0t on Update project from SP20 to SP21 CODESYS Forge talk (Post)
Hello everyone. I have a problem: I installed new version of codesys IDE. When I try open project in this new version, I have many errors about Visu: rectalnge/button/frame/etc does not exist. How update properly project? 20+ pages of visu pages from 100+ frames and all visu elems looks like "Error image". It is not problem of SP20->SP21. Any update has problems from visu side.
Last updated: 2025-06-09

Post by berkdan on SMC_ReadNCFile2 is always busy CODESYS Forge talk (Post)
Hello, I’m using CODESYS V3.5 SP18. When I try to use SMC_ReadNCFile2 to read the file /PlcLogic/gcode.nc, the function block's bBusy output remains TRUE indefinitely. Can you help me understand what I might be doing wrong? Here is how I’m calling the function block. The value of strFileName is 'gcode.nc'. fbReadFile( bExecute := bExecute, sFileName := strFileName, bAbort := bCycleStop, fDefaultVel := RetainVariables.xSlowVelocity, fDefaultAccel := RetainVariables.xAcc, fDefaultDecel := RetainVariables.xDec, b3DMode := TRUE, bParenthesesAsComments := TRUE, fDefaultVelFF := RetainVariables.xFastVelocity, fDefaultAccelFF := RetainVariables.xAcc, fDefaultDecelFF := RetainVariables.xDec, ErrorID => gCNC.eErrorId, errorPos => gCNC.eErrorPos, ErrorProgramName => gCNC.eErrorProgName, bBusy => bReadFileBusy, sentences => sentencesss ); Thanks in advance for your help.
Last updated: 2025-06-16

Post by hickan on safety cpu cannot go online CODESYS Forge talk (Post)
Hi! I am using abb ac500 in automation builder v2.7 I have a problem with a new project. In the normal mode I have no problems, but in safety mode i cannot go online. I get 'Communication Error (#0) Logout Performed' message. I have tried changing the adress (level 1) in communication parameters. I tried 0.0.0.0.0 and 0.1.0.0.0 and 1.1.0.0.0 but it did no difference. What do you think could be causing this? Thanks!
Last updated: 5 days ago

Post by sunfloweeerrry on Edgelogix-rpi-1000-cm4102032 SPI port connection to PiFace I/O Driver in CodeSys. CODESYS Forge talk (Post)
Hello, I hv a problem. Couldn't solve this for 2 days now. So I'm quite new at CodeSys and I have to use the spi port x30 on the edgelogix rpi 1000. So what I have to do is just 'add device' at the SPI where I hv to pick the 'SPI master' after that I hv to change the parameters according to the edgelogix I did found in the spidev.h but nothing got updated so I 'add device' again where I pick the PiFace I/O Driver and I put my variables at the I/O Mapping, which i put the input startbit at the in part and led at the out part. I want to make the led blink according to my structured text code but somehow the hardware didn't connected with the CodeSys spi port. Nothing happens. Any idea what I have to do?
Last updated: 2023-08-18

Post by jegerjon on Find index based on values CODESYS Forge talk (Post)
Hi, I need to figure out witch indexes of an Array containing the highest and lowest values. Typically search for the 5 lowest values and result the indexnumbers containing the 5 lovest values. is there a library for this, or codeexample?
Last updated: 2023-08-20

Post by jegerjon on Find index based on values CODESYS Forge talk (Post)
Hi, I need to figure out witch indexes of an Array containing the highest and lowest values. Typically search for the 5 lowest values and result the indexnumbers containing the 5 lovest values. is there a library for this, or codeexample?
Last updated: 2023-08-20

Post by sven01 on Documentation / Usage Help For Scripting Engine Libraries CODESYS Forge talk (Post)
Hi, I am still not able to figure out how to use the the classes and their functions. πŸ˜” Let's say I would like to use the function "importfile()" from the class "ScriptTextListObject.ScriptTextListMarker". I would be grateful for an additional example. Thanks! 😊
Last updated: 2023-08-21

Post by kunz on Profinet Device keeps abort connection with AR alarm.ind(err) CODESYS Forge talk (Post)
Can somebody explain what the error Connection aborted: AR alarm.ind(err) exactly mean? I have the same Problem and dont know how to solve the issue
Last updated: 2023-08-21

Post by rossanoparis on After un upgrade of "CODESYS Control for Raspberry Pi MC SL" from v4.7 to v4.9 SysFileOpen function stopped working CODESYS Forge talk (Post)
Hello at all. After un upgrade of "CODESYS Control for Raspberry Pi MC SL" from v4.7 to v4.9 SysFileOpen function stopped working. I'm not able to read or write files from the PLC application. Before this upgrade all worked fine. I've read this thread [ https://forge.codesys.com/forge/talk/Engineering/thread/3da9ded84e/ ] Despite I followed that indications I couldn't get my code working again. Perhaps I'm missing something or I didn't understand how to use placeholders at all. Is there a different syntax to use for "SysFileOpen" in order to use placeholders? Thanks in advance for your help. Information Compiler: CODESYS V3.5 SP19 Patch 2 Runtime: codesyscontrol 4.9.0 HW: KUNBUS RevPi Connect S Below the paths I want to access (The entire CODESYSControl_User.cfg file is attached) [SysFile] PlaceholderFilePath.1=/home/pi/hpca/bin, $hpcabin$ PlaceholderFilePath.2=/home/pi/hpca/cfg, $hpcacfg$ PlaceholderFilePath.3=/home/pi/hpca/logs, $hpcalogs$ PlaceholderFilePath.4=/home/pi/hpca/resources, $hpcares$
Last updated: 2023-08-22

Post by janderson on OPC UA Server limitations, large array crashes runtime CODESYS Forge talk (Post)
when using an array of structs, the runtime crashes. but when using an array of LREALS, it'll do 100k at least
Last updated: 2023-08-23

Post by eschwellinger on Connection to device closed CODESYS Forge talk (Post)
is there a way to check the plclog on Opus A3 by using cmd line under Linux? This log is what you need to check for the disconnection problem
Last updated: 2023-08-24

Post by reinier-geers on Ping By Name CODESYS Forge talk (Post)
How can i ping my computer by name ? My controler uses SysSockPing , But seems only by IP adres, not by name. IP adres changes. So how can i ping by name or know that im connected
Last updated: 2023-08-24

Post by eschwellinger on How to configure CODESYSControl_User.cfg in order to use a specific network card for OPCUA Server CODESYS Forge talk (Post)
check this faq section here: https://faq.codesys.com/plugins/servlet/mobile?contentId=102137886#content/view/102137886
Last updated: 2023-08-25

Post by cdutz on Problems connecting to Codesys 4.9.0.0 runtime on my Wago PFC200 CODESYS Forge talk (Post)
Turns out I managed to get a connection to my PLC. It seems that a few weeks ago Wago released something with version 4.3.3(25). So I reset my PLC to Factory-Reset, set it to the 192.168.1.17 IP and changed the IP to the one I wanted with the Wago EthernetSettings tool. Then updated the latest firmware using the WAGOupload tool. Now the PLC came back up without a PLC runtime running, so in the Web-tool I wen't to the "Configuration"/"PLC Runtime" and selected the runtime version "CODESYS V3". I uninstalled all Codesys versions and installed the version from the download package of Wago together with all the packages the bundle provided. After creating a new project I didn't select the old PFC200 runtime, but one of the dozens of new device profiles, that it now listed. With these settings I was then able to connect to my PLC. Now I hope I'll get the existing project that I had ported to this new structure. Sorry for the noise. Chris
Last updated: 2023-08-26

Post by eschwellinger on How to configure CODESYSControl_User.cfg in order to use a specific network card for OPCUA Server CODESYS Forge talk (Post)
Hi Rossano, thank you for the feedback, you are right this need to be changed in the faq section. Regards Edwin
Last updated: 2023-08-28

Post by reinier-geers on Ping By Name CODESYS Forge talk (Post)
To bad. Controller uses Version 9.2 But i dont see a lower version of net bas Service. Maybe i can try a linux command.
Last updated: 2023-08-29

Post by eschwellinger on CSVReaderInit returns error : INVALID_HANDLE CODESYS Forge talk (Post)
this is a security issue not to read/write in the plc allowed path I would recommend to update and change the path in the application were the files are😏
Last updated: 2023-08-30

Post by roundex on CSVReaderInit returns error : INVALID_HANDLE CODESYS Forge talk (Post)
Could you please give me an example where to select new path in plc. Right now my csv files are placed into /home/user/csvfiles
Last updated: 2023-08-30

Post by totorovic on CSVReaderInit returns error : INVALID_HANDLE CODESYS Forge talk (Post)
Thank you for the return. The path targets to a CFast card. User has R/W access to it. We will try to change it.
Last updated: 2023-08-31

Post by felipemsgarcia on EtherCAT - Force Control Word CODESYS Forge talk (Post)
What worked for me: Use SMC_SetControllerMode and set the nControllerMode to SMC_nocontrol. With that, you can control the drive via Modes of Operation(16#6060) and Controlword(16#6040) directly. Hope that helps, Cheers!
Last updated: 2023-08-31

Post by marekxc on Error C0521 - unknow compiler CODESYS Forge talk (Post)
Select in tree "DEVICE", right-click and select "Update Device" Select "Library manager" and Change the version of the Library (down manualy). Samoetimes "Try reload Library". If you open a project version 3.5.19 in version 3.5.16, there are difficulties.
Last updated: 2023-09-02

Post by janderson on Ethercat scan for devices not picking up EL7041 as a softmotion axis CODESYS Forge talk (Post)
I have a beckhoff EL7041-1000 rev 21 in my ethercat bus but it wont correctly create a softmotion axis unless i manually insert the device. scan for devices gives me an el7041-1000 without an SM3 axis.
Last updated: 2023-09-02

Post by eschwellinger on Ethercat scan for devices not picking up EL7041 as a softmotion axis CODESYS Forge talk (Post)
Add existing version (with SM drive) - without scan - disable under expert settings in the slave the revision check.
Last updated: 2023-09-03

Post by automa on Defining local variables that can be independent with several users. CODESYS Forge talk (Post)
Hi, I am looking for a way to define a local variable that will be multi user independent. This is so several user can connect at the same time select frames independent of each other.
Last updated: 2023-09-04

Post by laazik2 on v3.5 SP19 - Modbus TCP Devices - Channel Limit? CODESYS Forge talk (Post)
I am actually wondering as well if there are plans to fix it or not? As adding two modbus devices creates it's own problems with connection limits and other issues, which some slave devices have.
Last updated: 2023-09-05