Post by timvh on SafetyApp - "Invalid ERR Ack input" CODESYS Forge talk (Post)
I had a similar error "Invalid ERR Ack input". What you need to do is link an variable from the "non-safe" PLC to the Group IOs of the POU in the Safety app. * Add a POU to the SafetyApp (probably already done, otherwise you don't get this error) * Right click on this POU - select properties * Go to the Group IOs tab * Link a variable to the Err.Ackn. input I don't know about the Size of zero, I didn't get this error. Were you able to fix this?
Last updated: 2023-11-16

Post by drno on AlarmMgr Database Error in method WriteToStorage: Error code = 30531, Action = 1030 CODESYS Forge talk (Post)
Hallo zusammen, auf einer Industriesteuerung (Target-Version 3.5.5.0) läuft unter anderem eine Alarmverwaltung mit Alarmspeicherung. Offensichtlich kann kein Schreibzugriff auf das .sqlite File durchgeführt werden, daher ist die Alarmhistorie nicht mehr verfügbar. Versuche mit unterschiedlichen Unterverzeichnissen führten nicht zum Erfolg. Die Datei "application.alarmstorage.sqlite" wird zwar angelegt, aber es erfolgen keine Einträge. Hat jemand eine Idee dazu? Die Steuerung ist ca. 8 Jahre in Betrieb, die Alarmhistorie hat früher mal funktioniert. Danke, LG
Last updated: 2023-11-21

Post by joanm on Tab control element, hide/show tabs programatically? CODESYS Forge talk (Post)
Hi all, Is it possible to hide or show tabs from the PLC code? I have created a few tabs in my visualizations to configure the program behavior, I'd like to be able to hide some of them if the related option in the main tab has been disabled. Is that possible? if so, how should I do it? Thank you all in advance.
Last updated: 2023-11-25

Post by siggi95 on Übersetzungsfehler J1939 changeAdress (4.1.0.0) CODESYS Forge talk (Post)
Hallo zusammen, für den Aufruf VAR deviceDiag: J1939.IJ1939LocalECU; END_VAR deviceDiag.ChangeAddress(5); gibt es mit der Version 4.1.0.0 der Lib IoDrvJ1939 Übersetzungsfehler - C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'deviceDiag.ChangeAddress' erwartet - C0004: 'ChangeAddress' ist keine Komponente von 'IJ1939LocalECU__Union' Mit der bisher verwendeten Lib-version 3.5.17.0 nicht und auch das Setzen der device adress hat funktioniert. Lt. Release notes ("J1939: ChangeAddress method does not work properly.") wurde hier verbessert. Leider habe ich keine Beschbreibung dazu gefunden. Wie muss der Aufruf angepasst werden? Vieeln Dank und beste Grüße Siggi
Last updated: 2023-11-29

Post by alink on Visu - changing auto-logout time CODESYS Forge talk (Post)
Hello is there a chance to set with a visu input the auto-logout time? At the moment, it is a fix value set in visu-manager. But for individual configurating of passwort policies I create a visu-dialog to set policies and there for an option to set auto-logout-time. But till now, I haven't found a solution. Maybe someone has an idea? Thanks
Last updated: 2023-11-30

Post by macros8 on Translation - How to get text as reference in Frames translated? CODESYS Forge talk (Post)
Hi all, I need a help. I want to create Frame where some parameters are done via reference input to this frame. What I have realized that if I use for Label/Caption etc. string variable (%s) it is not included in translation list. This is a quite a big deal and I did not find way how to add text to the list manually. Would you give me a hint how to proceed? I hope there is a way (workaround) how to do it. Thanks a lot. M.
Last updated: 2023-12-01

Post by macros8 on Alarm Management - Import and Export of AlarmGroup CODESYS Forge talk (Post)
Hi, I struggle with exporting my Alarm Messages and following importing back to my project. Because filling in one by one is very time consuming I want to use export function and edit .csv file in Excel. As soon as I modify the file the import back to project does not work at all and function returns errors. Would you pls give me a hint how to properly use this functionality? Thanks a lot for help. Regards, M.
Last updated: 2023-12-02

Post by simotion on Inheritance of axis CODESYS Forge talk (Post)
I have developped a function block 'Axis' the inherits from 'AXIS_REF_SM3' -> FUNCTION_BLOCK Axis EXTENDS AXIS_REF_SM3 In my global variable list I define a variable MasterDrive of type Axis and assign Axis1. Axis1 is a virtual drive (AXIS_REF_VIRTUAL_SM3). This type should inherit from AXIS_REF_VIRTUAL. VAR_GLOBAL MasterDrive : Axis := Axis1; However I get the error 'Cannot convert type'. What is the way to obtain what I want : function block inheriting AXIS_REF_SM3 and initialising this function block with a Softmotion virtual or real axis?
Last updated: 2023-12-07

Post by voffi on Converting UINT into bytes and converting 2Bytes into UINT CODESYS Forge talk (Post)
There are some ways. One is to use SHR and SHL and it depends on your byte order in the data array. For Motorola byte order: PROGRAM PLC_PRG VAR u : UINT; byte_array_in : ARRAY [1..8] OF BYTE := [16#11, 16#12, 16#13, 16#14, 16#15, 16#16, 16#17]; byte_array_out : ARRAY [1..8] OF BYTE; END_VAR u := SHL(TO_UINT(byte_array_in[2]), 8) + TO_UINT(byte_array_in[1]); byte_array_out[1] := TO_BYTE(u); byte_array_out[2] := TO_BYTE(SHR(u, 8)); If it's Intel byte order just change 1 and 2 in the array indexes.
Last updated: 2023-12-07

Post by nz-dave on Bool turning on in case stament in wrong state? CODESYS Forge talk (Post)
I have a case statement running a process. during one of the steps it has started calling a bool var that is 2 steps further on in the case? i have even tried //commenting it out but it still turns on at the same point in the case. i have also run a trace but cant see anything that would trigger it. Any Ideas? Cheers
Last updated: 2023-12-15

Post by solidlogicguy on Little endian to Float from Modbus RTU CODESYS Forge talk (Post)
Hello, I got a device from which I require to read values from I am using a WAGO PLC 750-8212 and I am communicating through Modbus Master FUNCTION BLOCK from library WagoAppPLCModbus in Codesys 3.5 to this device. I already receive data from the device that is a CVM to monitor voltage from a fuel cell. The technical support of the company that makes these devices says that the data is sent in little endian form. And I want to convert it to a float value. The tech support sent me the next instructions of how to do it but I am new using codesys, so any advice or help I will really appreciate so much. Message from tech support: The process is complicated, better to do it with already implemented library in the language/program you use. Basically the process should be next: To convert the two Modbus registers containing parts of a 32-bit float in little-endian byte order to a floating-point number using mathematical operations, you first need to combine the two 16-bit integers (assuming reg1 is the lower word and reg2 is the higher word) and then interpret the result according to the IEEE 754 standard. Given: - Register 192 (reg1) = 4096 - Register 193 (reg2) = 14884 Step 1: Combine the two registers. Since we are dealing with little-endian byte order, reg2 is the high word, and reg1 is the low word: combined = reg2 * 2^16 + reg1 combined = 14884 * 65536 + 4096 combined = 975175680 + 4096 combined = 975179776 Step 2: Convert the combined value to binary: combined_binary = '1110101101011100000000000000000' Step 3: Split the binary into IEEE 754 components: Sign bit (1 bit): 0 Exponent (8 bits): 11101011 Mantissa (23 bits): 01011100000000000000000 Step 4: Convert the binary exponent to decimal and subtract the bias (127 for 32-bit floats): exponent = int('11101011', 2) - 127 exponent = 235 - 127 exponent = 108 Step 5: Calculate the mantissa as a fraction: The mantissa in IEEE 754 format is the fractional part after the leading 1 (which is implicit). Therefore, we need to convert the binary mantissa to decimal and add the implicit leading 1: mantissa_fractional = 1 + int('01011100000000000000000', 2) / 2^23 mantissa_fractional = 1 + 18688 / 8388608 mantissa_fractional = 1 + 0.002227783203125 mantissa_fractional ≈ 1.002227783203125 Step 6: Combine the sign, exponent, and mantissa to get the float value: float_value = (-1)^0 * mantissa_fractional * 2^exponent float_value = 1 * 1.002227783203125 * 2^108 Because the exponent is quite large, the resulting float value is a very large number.
Last updated: 2023-12-15

Post by macros8 on Translation - How to get text as reference in Frames translated? CODESYS Forge talk (Post)
Hi, one more point. I have been able to create Property of Text which is added to Global text list so it´s fine. But as soon as I use Frame configuration I lose all other properties but some very basics. I need to have still possibility to set Input configuration because my element is Button. Do you know how to make visible all standard properties + my own properties created in Frame configuration? Thanks a lot. M.
Last updated: 2024-01-03

Post by tvm on SEND_RECV_MSG function block on Schneider Machine Expert CODESYS Forge talk (Post)
Anyone else using the SEND_RECV_MSG function block for RS-485 communication on Schneider Machine Expert? I have had ongoing issues with it for several years, which Schneider tech support is aware of, but hasn't been able to fix. The latest version of Machine Expert (v2.2) appears to have broken some of the functionality altogether. I'd be interested in hearing from anyone else using this platform for serial communication.
Last updated: 2024-01-03

Post by tvm on multiply gives negatives CODESYS Forge talk (Post)
It's probably because you have an INT in the input to the MUL function, which will then try to output an INT as well. INT variables can only handle values of -32768 to 32767. Your value of 523000 won't fit in an INT, so it turns into an invalid number. Use a DINT. This is usually better for working with time values anyway, because time values are all 32 bit. Or if you can't, use INT_TO_DINT(gvlp.detectie_nalooptijd_s) in the input to the MUL function.
Last updated: 2024-01-04

Post by usacodesysuser on How to connect serial devices ? CODESYS Forge talk (Post)
@eschwellinger do you have any examples of using a USB barcode scanner? I have read through the forums here and I am unable to find how to get the barcode data to populate in a text field without having to first click into the text field to activate it. Is there a library that allows you to access the barcode data? I am really new to this in general any help is greatly appreciated, hopefully you have a pretty clear example
Last updated: 2024-01-06

Post by apurv on Cannot pass array of constant size to a function as a reference CODESYS Forge talk (Post)
I have a Array of constant size defined like this Var Constant MAX_SIZE :UINT := 10; End_var VAR array : ARRAY[0..MAX_SIZE] OF INT; END_VAR Now I want to pass this array to a function by reference, Function fun : INT VAR_IN_OUT CONSTANT MAX_SIZE : UINT; END_VAR VAR_INPUT array : REFERENCE TO ARRAY[0..MAX_SIZE] OF INT; END_VAR but when I run this it gives strange Errors Error : Cannot Convert type 'ARRAY [0..MAX_SIZE] OF INT' to type 'ARRAY[0..MAX_SIZE] OF INT'
Last updated: 2024-01-07

Post by toby on SM Drive license error CODESYS Forge talk (Post)
Hi albert1999 and forest, I hope you are well. I too am wondering if you have found any solutions? Im working with a RPi and a Omron R88D-ETH servo amplifier. The SoftMotion is timing out after 30min without the license, but I cant figure out how to license it, and I seem to have some compatibility issues between my RPi license and any SoftMotion licenses. Did you guys have any luck? Thank you very much for any assistance offered. Toby
Last updated: 2024-01-10

Post by sturmghost on Visualization using methods and cyclic ST-calls CODESYS Forge talk (Post)
I found a way to do it: You can use, for example, the text variable property of any visualization element and call a function in it. Example: Write a test POU as a function (FUN), like MyTestFun which need a boolean Variable as an input value. Now write into the text variable property: MyTestFun(bBooleanValue) Thats it. The function is called at each visu_task cycle.
Last updated: 2024-01-22

Post by jinlee on Multiple WebVisu CODESYS Forge talk (Post)
Hi guys, I am new to the Visualization. I am having a problem. I have multiple web-panel to use webvisu. I have my software dowwloaded into the one PFC200. There are 3 screens connected to it. I noticed that if I switch page/visualisation on one of the screens, the others will change as well. Three screens are with different URLs that I set in the software. Is there any method to make them independently ? Kind regards, Jin.
Last updated: 2024-01-25

Post by jaspergain on Access to the path *** is denied CODESYS Forge talk (Post)
Hello, Recently I upgraded to 3.5.19.50 and have been having errors/issues when doing a download/online change. The message as seen in the attachment pops up. The file in the path is different every time. However when I login again afterwards all works fine. This issue does not happen on older versions. Any clue what the issue could be? I did an reinstall/repair but the issue reappeared again... Thanks in advance!
Last updated: 2024-01-25

Post by wiresplus on INT_TO_WORD function not working CODESYS Forge talk (Post)
Hello, I need to take an INT input, and convert it to a WORD value. VAR DRV2Speed : WORD; //IO card takes a WORD where 16000 = full 10V output (equivalent to 50Hz) PumpFillSpeed : INT; //Users enter a value between 0 and 50 END_VAR IF <conditions> THEN DRV2Speed :=INT_TO_WORD((PumpFillSpeed/50)*16000); END_IF </conditions> According to me this should work - but it stays at 0, no matter what. What am I doing wrong?
Last updated: 2024-01-26

Post by wiresplus on Cannot get INT_TO_TIME working CODESYS Forge talk (Post)
Hello, I have a simple TON timer. It is watching prime loss for a pump. The operator can set the delay via the HMI, it is an integer (seconds) As the TON uses milliseconds, we then multiply the entry by 1000 to get seconds. Seems simple, but... VAR PrimeTimer : TON; primetime : INT; END_VAR PrimeTimer(in:=State>0 AND FlowRate<MinimumFlow,pt:=INT_TO_TIME(primetime *1000)); For an entered 15 seconds (VAR primetime:=15;) the timer reads 49d17h2m26s760ms !!!! What am I doing wrong?
Last updated: 2024-01-26

Post by ojz0r on INT_TO_WORD function not working CODESYS Forge talk (Post)
That calculation will not work the way you expect it to. If PumpFillSpeed is limitied to 0-50 then the only whole number would be 50/50 = 1 everything else is 0.0-0.9999... and since you are using word and integer only 50 would work since there is no representation for mantissa in integer values. Declare a temporary real variable and do the calculation and then do a REAL_TO_WORD in the DRV2Speed assignment.
Last updated: 2024-01-26

Post by melle17 on Steuerung einer Geschirrspülmaschine CODESYS Forge talk (Post)
Hallo, ich muss im Rahmen einer Hausarbeit die Steuerung einer Geschirrspülmaschine erarbeiten. Leider bin ich mit dem Programm noch nicht so vertraut und habe Probleme bei meinem Zeitschalter und finde leider selber das Problem nicht. Deswegen zu meiner Frage ob mir jemand helfen könnte. Und zwar kommt das meine Variablen nicht deklariert sind und ich finde aber nicht wieso. Die zwei Screenshots zeigen nochmal den Zeitschalter und das Programm wo der Zeitschalter eingesetzt wird. Vielen Dank im Voraus.
Last updated: 2024-01-30

Post by matt-s on HMI Pushbutton/Move Instruction CODESYS Forge talk (Post)
I have not gotten to the bottom of this yet no. I have double check that the variables are correct linked. When online with the program I can see the button and rung going true for the move instruction, yet it does not change. Forcing the bit in the program does change the value in Groov View. I am kind of at a loss here, especially since the other POU(For the pumps) does the same thing fine.
Last updated: 2024-02-02