Post by lostcontrol on Bool turning on in case stament in wrong state? CODESYS Forge talk (Post)
i would be looking at what the case variable is doing then.. sounds like there might be a logic race going on
Last updated: 2023-12-16

SM3 motion project CODESYS Forge talk (Thread)
SM3 motion project
Last updated: 2023-12-18

Post by reinier-geers on SM3 motion project CODESYS Forge talk (Post)
Hi, i try to setup a softmotion programm. Controller version 15. Ethercat, When is scan Devices then it install's the drives. 4.11 . Somehowe they have a vesion 16 libary. I tried to install new but stil problems. I tried version 19. Then i get a Visu version problem. What can i do ? Why are ther always problems with a new version ?
Last updated: 2023-12-18

Post by andrax on Meine Gerätesammlung basierend auf TCA9548 CODESYS Forge talk (Post)
Hallo zusammen, ich programmiere öfters mal kleinere Messgeräte und Datenlogger. Je nach Einsatzzweck musste ich mir ein paar Gerätetreiber selber schreiben. Da es eine recht große Sammlung ist, stelle ich die hier einfach mal ein. Die Sammlung basiert auf den Gerätetreiber TCA9548 Multiplexer von Steffen Dreyer. Codesysversion: V3.5 SP18 Patch 4 Inhalt: -4channel Dimmer (Stefan Dreyer) -BMA456 (Andre Klien) -BME280 (Stefan Dreyer) -BMP280 (Stefan Dreyer) -EEPROM_24C512 (Stefan Dreyer) -ADS1115 (Andre Klien) -ICP10125 (Andre Klien) -PCA9555 (Stefan Dreyer) -PCA9685 (Stefan Dreyer) -PCF8575 (Stefan Dreyer) -SDP810 (Andre klien) -SSD1306 (Stefan Dreyer) -TCA9548 (Stefan Dreyer) -TSL2561 (Stefan Dreyer) Alle Gerätetreiber laufen über den Multiplexer, können aber auch ohne betrieben werden. Einschränkung: BMA456: Die Konfigurationsdaten werden erfolgreich in den Chip geschrieben, dieser meldet aber config wrong. Warum auch immer, der Sensor funktioniert und bringt hochempfindlich Beschleunigungsdaten. ADS1115: Hie habe ich nur die wichtigsten funktionen implementiert. 1-4 Kanäle, PGA, kontinuierlicher Modus, Datenrate. Alle anderen Funktionen (single-shot, komparator,alm) sind nicht implementiert. Das macht auch keinen Sinn, da diese Funktionen besser über die Steuerung realisiert werden können. Achtung beim ADS1115 ist zwingend ein Levelshifter notwendig, wenn ihr diesen mit 5V betreiben wollt. Ihr grillt sonst euren Raspi (SDA, SCL sind dann 5V) Gruß Andre
Last updated: 2023-12-18

Meine Gerätesammlung basierend auf TCA9548 CODESYS Forge talk (Thread)
Meine Gerätesammlung basierend auf TCA9548
Last updated: 2023-12-18

Post by mark on IO link on IFM AL133x only single digital input on a channel CODESYS Forge talk (Post)
I have a problem with the CODESYS IO-Link SL software. When I insert a IO link master AL1332 and plug a discrete digital input to a channel it reads only 1 of the 2 available inputs on that channel. Is there anyone who sorted out if the second input is also usable? When we configure the module without the CODESYS IO-Link SL software then the second input on the channel can be used. At the moment we use some channels on a module as IO-link port, and some as discrete IO. It would be very nice if we can use both inputs on a channel with the use of CODESYS IO-Link SL.
Last updated: 2023-12-18

Post by mavitia on Application based license problem - Modbus TCP CODESYS Forge talk (Post)
I am running ubuntu on a raspberry pi, and installed an application based license Control Basic M on it, it runs a demo program fine, does not timeout etc. however, when I add a modbus TCP device, I start getting errors: <Entry severity="error" component="CmpApp" user="nobody" timestamp="12/18/2023 3:49:42 PM" infoId="24">Online change denied. Application Application is in exception state!</Entry> <Entry severity="error" component="CmpApp" user="nobody" timestamp="12/18/2023 3:49:42 PM" infoId="68">Download failed: Application=Application</Entry> <Entry severity="exception" component="CmpApp" user="nobody" timestamp="12/18/2023 3:49:41 PM" infoId="0">Application app=Application has invalid license metrics!</Entry> the modbus tcp slave runs, and the counter ticks up, however, when I call the variables on the %IX0.0 in my program, and try to upload the changes, I am getting the error messages which stop the program as far as I understand, the application based, M includes 2 fieldbus instances, but on the other side is fairly new, anything obvious I am missing out here?
Last updated: 2023-12-18

Post by mavitia on Application based license problem - Modbus TCP CODESYS Forge talk (Post)
raspberry pi is running ubuntu, so it has the codesys control for linux arm 64 bit, IDE is 3.5.19, both were installed last week from the latest versions online, im currently out of the PC but will upload some evidence ASAP
Last updated: 2023-12-18

Post by snhatton on Some visualization objects disappear when user is logged in? CODESYS Forge talk (Post)
Did you check the access rights of the visualization elements in question?
Last updated: 2023-12-18

Post by user0815 on Web Socket Client SL -Bibliothek Fehler CODESYS Forge talk (Post)
Sobald ich probiere eine Nachricht von Node-RED an Codesys zusenden.
Last updated: 2023-12-18

Post by eschwellinger on Application based license problem - Modbus TCP CODESYS Forge talk (Post)
Which versions exactly are involved? Runtime on PI? CODESYS Version and compilerversion?
Last updated: 2023-12-18

Post by eschwellinger on Web Socket Client SL -Bibliothek Fehler CODESYS Forge talk (Post)
bei welcher Aktion kommt dieses Fenster mit dem Source Code?
Last updated: 2023-12-18

Post by eschwellinger on Application based license problem - Modbus TCP CODESYS Forge talk (Post)
you could sent the projectarchive to 'my question' in the CODESYS store
Last updated: 2023-12-18

Post by user0815 on Web Socket Client SL -Bibliothek Fehler CODESYS Forge talk (Post)
Doch aber ich dachte nur die Fehler sind in den Logs relevant. Ich kann morgen ein Bild von den gesamten Logs hochladen.
Last updated: 2023-12-18

Application based license problem - Modbus TCP CODESYS Forge talk (Thread)
Application based license problem - Modbus TCP
Last updated: 2023-12-18

Post by simover on TCP/IP client CODESYS Forge talk (Post)
I want to send a string to a tics TCP/IP server. I got i working with the Net Base lib. for communication good with this tcis i need to by array of byte I want to include a string in the third position of the array TCIS_Send[1] :=254; //this valus is fix for evry communication TCIS_Send[2] :=80; //this valus is fix for evry communication TCIS_Send[3] := ; here I put my and my string is lik this 5806509-DRAP10#AB#3452302073 TCIS_Send[4] :=252; //this valus is fix for evry communication
Last updated: 2023-12-18

Post by trycyclepower on How to remove other libraries and keep the only one I have created. CODESYS Forge talk (Post)
I have created my own library inside codesys and when I import it, it has other basic and standard library inside. How do I extract those libraries and keep the only one that I have created? Thanks.
Last updated: 2023-12-18

Post by eschwellinger on Web Socket Client SL -Bibliothek Fehler CODESYS Forge talk (Post)
aber sind dann nicht auch exceptions im Log zu sehen?
Last updated: 2023-12-18

How to remove other libraries and keep the only one I have created. CODESYS Forge talk (Thread)
How to remove other libraries and keep the only one I have created.
Last updated: 2023-12-18

CAN TPDO / RPDO CODESYS Forge talk (Thread)
CAN TPDO / RPDO
Last updated: 2023-12-19

Post by vahasa on CAN TPDO / RPDO CODESYS Forge talk (Post)
Hi I'm automation engineering student and I'm not yet quite familiar with CAN-bus. What I am trying to achieve, to send two byte message via CAN from Epec display to Scott Drive inverter. I'm using code template made with Epec Multitool in Codesys 3.5 Problem i'm facing is that drive responds with same COB-ID. In multitool, you can create TPDO/RPDO. And depending on that, display either sends or only receives. This is problem, because for parameter polling from drive, you need to send two byte request to 0x399 and drive responds with eight bytes. If request is longer, drive don't respond. 0x399 is currently setted as RPDO, so display doesn't send anything on startup and I made program that sends messages to 0x399 bytes 0 and 1 and bytes 3-7 are shown in display. If setted as TPDO, display send all eight bytes and therefor drive cannot respond. But, I think because they are defined as RPDO, display won't send message, although monitoring with Codesys, values are changed. Question is, how should COB-ID be configured in Codesys, so it wouldn't automatically start to send message but would send when needed?
Last updated: 2023-12-19

Post by reinier-geers on Softmotion general CODESYS Forge talk (Post)
Hi, Im busy using softmotion. But its reading data , but no respons on the commands. Most examples has Softmotion General exis pool. How can get that?
Last updated: 2023-12-19

Post by ph0010421 on TCP/IP client CODESYS Forge talk (Post)
Hello TCIS_Send needs to be longer than 4 bytes because idata is 28 bytes long. There may be other ways, but I would make a UNION with string/array of bytes. Write your STRING into the AsString part then copy the AsBytes part into TCIS_Send (Elements [3] to [30]) then 252 would be in [31] (I've assumed the idata is always the same length)
Last updated: 2023-12-19

Post by spiessli on Raspberry Pi 4 with Legacy Drivers and Codesys 3.5.19 Patch 4 CODESYS Forge talk (Post)
Hi, I wanted to use the Adafruit Hat for the Raspberry and get acquainted with Softmotion using servos for RC models. This did work great with Codesys 3.5.19 Patch 1, but with Patch 4 and 5 i get errors. I suspect changes in the SoftMotion library have broken dependencies in the legacy drivers, might that be true? Thanks for any hint, spiessli Here the error log: ------ Übersetzungslauf gestartet: Applikation: Device.Application ------- Code typisieren... Code erzeugen... [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet Übersetzung abgeschlossen -- 15 Fehler, 0 Warnungen : Kein Download möglich
Last updated: 2023-12-19

Post by giglecald on Visualisations in Frames CODESYS Forge talk (Post)
Almost 2024 and I'm looking for this too XD Can't seem to find a way to get the current visualization inside a frame
Last updated: 2023-12-19