Post by timvh on Specify Input Configuration "OnDialogClosed" Action to only react to certain Dialogs
CODESYS Forge
talk
(Post)
What maybe helps is the Visu Dialog ST demo project: https://store.codesys.com/en/visu-dialog-st.html This has an application IECOpenDialog where dialogs are opened using the VU.FbOpenDialogExtended function blocks. The fbOpenConfigurationDialog call has a reference (interface) to the "close listener" FB of which it's method is automatically called when the dialog is closed. This way you can create specific function blocks for each dialog when it is closed and do what you want with the data that might have been changed.
Last updated: 2023-09-28
Post by tehthoams on Library Search not working
CODESYS Forge
talk
(Post)
Hello All! Having a strange issue. When adding a library, I'm unable to search. Each time a window pops up 'creating the search index' and then has 0 results. I have the same behavior when using the library repository and pressing the 'Find' button. I wonder if there is a way to reset or fix this issue? It is making it very difficult to search and find proper libraries to add to my project. Much appreciated.
Last updated: 2023-10-17
Post by davidbo on RPI How to login for a copy of the SD image
CODESYS Forge
talk
(Post)
I had one RPI device where I could login. I copied the SD-flash over to another SC-flash. This new SD-flash was inserted in the new device. I can boot the new device but I cannot login why? How can I install an application on this new device? Control 4.4.0.0 cat os-release PRETTY_NAME="Raspbian GNU/Linux 11 (bullseye)" NAME="Raspbian GNU/Linux" VERSION_ID="11" VERSION="11 (bullseye)" VERSION_CODENAME=bullseye ID=raspbian ID_LIKE=debian HOME_URL="http://www.raspbian.org/" SUPPORT_URL="http://www.raspbian.org/RaspbianForums" BUG_REPORT_URL="http://www.raspbian.org/RaspbianBugs"
Last updated: 2023-10-18
Post by hgpiepel on CSV Datei in einem freigegebenen Netzlaufwerk speichern
CODESYS Forge
talk
(Post)
Hallo zusammen, ich erstelle eine CSV-Datei, die im Moment mit file.Write lokal in einem Verzeichnis (/home/pi/Logdaten/logData.csv) gespeichert wird. Jetzt möchte ich die gesammelten Daten aber gerne im Netzwerk speichern. Der Versuch, die Datei unter //Server/Public/logData.csv zu speichern, hat sich so geäußert, dass ein Ordner (Server) im Stammverzeichnis auf dem Pi mit Unterordner erstellt wurde und dort die Datei abgelegt wurde. Gibt es hier eine einfache Möglichkeit, die Datei vom Pi herunter zu bekommen? Leider habe ich im Netz nicht wirklich was hierzu gefunden. Grüße Hermann
Last updated: 2023-10-30
Post by nathant on Can't open online view of FB instance from code editor, only from Device/POU windows
CODESYS Forge
talk
(Post)
Hello, The title pretty much says it all. When trying to open a FB from the CFC/Ladder/SFC editors while online, the FB does not open in an online view of that specific instance. Instead, it opens an offline view with '???' shown for the value of any variable. This makes debugging extremely cumbersome, as I have to find each FB in the POU window and select the specific instance I am trying to view. Anyone know the cause/solution for this? Thanks.
Last updated: 2023-11-08
Post by timvh on SafetyApp - "Invalid ERR Ack input"
CODESYS Forge
talk
(Post)
I had a similar error "Invalid ERR Ack input". What you need to do is link an variable from the "non-safe" PLC to the Group IOs of the POU in the Safety app. * Add a POU to the SafetyApp (probably already done, otherwise you don't get this error) * Right click on this POU - select properties * Go to the Group IOs tab * Link a variable to the Err.Ackn. input I don't know about the Size of zero, I didn't get this error. Were you able to fix this?
Last updated: 2023-11-16
Post by drno on AlarmMgr Database Error in method WriteToStorage: Error code = 30531, Action = 1030
CODESYS Forge
talk
(Post)
Hallo zusammen, auf einer Industriesteuerung (Target-Version 3.5.5.0) läuft unter anderem eine Alarmverwaltung mit Alarmspeicherung. Offensichtlich kann kein Schreibzugriff auf das .sqlite File durchgeführt werden, daher ist die Alarmhistorie nicht mehr verfügbar. Versuche mit unterschiedlichen Unterverzeichnissen führten nicht zum Erfolg. Die Datei "application.alarmstorage.sqlite" wird zwar angelegt, aber es erfolgen keine Einträge. Hat jemand eine Idee dazu? Die Steuerung ist ca. 8 Jahre in Betrieb, die Alarmhistorie hat früher mal funktioniert. Danke, LG
Last updated: 2023-11-21
Post by joanm on Tab control element, hide/show tabs programatically?
CODESYS Forge
talk
(Post)
Hi all, Is it possible to hide or show tabs from the PLC code? I have created a few tabs in my visualizations to configure the program behavior, I'd like to be able to hide some of them if the related option in the main tab has been disabled. Is that possible? if so, how should I do it? Thank you all in advance.
Last updated: 2023-11-25
Post by siggi95 on Übersetzungsfehler J1939 changeAdress (4.1.0.0)
CODESYS Forge
talk
(Post)
Hallo zusammen, für den Aufruf VAR deviceDiag: J1939.IJ1939LocalECU; END_VAR deviceDiag.ChangeAddress(5); gibt es mit der Version 4.1.0.0 der Lib IoDrvJ1939 Übersetzungsfehler - C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'deviceDiag.ChangeAddress' erwartet - C0004: 'ChangeAddress' ist keine Komponente von 'IJ1939LocalECU__Union' Mit der bisher verwendeten Lib-version 3.5.17.0 nicht und auch das Setzen der device adress hat funktioniert. Lt. Release notes ("J1939: ChangeAddress method does not work properly.") wurde hier verbessert. Leider habe ich keine Beschbreibung dazu gefunden. Wie muss der Aufruf angepasst werden? Vieeln Dank und beste Grüße Siggi
Last updated: 2023-11-29
Post by alink on Visu - changing auto-logout time
CODESYS Forge
talk
(Post)
Hello is there a chance to set with a visu input the auto-logout time? At the moment, it is a fix value set in visu-manager. But for individual configurating of passwort policies I create a visu-dialog to set policies and there for an option to set auto-logout-time. But till now, I haven't found a solution. Maybe someone has an idea? Thanks
Last updated: 2023-11-30
Post by macros8 on Translation - How to get text as reference in Frames translated?
CODESYS Forge
talk
(Post)
Hi all, I need a help. I want to create Frame where some parameters are done via reference input to this frame. What I have realized that if I use for Label/Caption etc. string variable (%s) it is not included in translation list. This is a quite a big deal and I did not find way how to add text to the list manually. Would you give me a hint how to proceed? I hope there is a way (workaround) how to do it. Thanks a lot. M.
Last updated: 2023-12-01
Post by macros8 on Alarm Management - Import and Export of AlarmGroup
CODESYS Forge
talk
(Post)
Hi, I struggle with exporting my Alarm Messages and following importing back to my project. Because filling in one by one is very time consuming I want to use export function and edit .csv file in Excel. As soon as I modify the file the import back to project does not work at all and function returns errors. Would you pls give me a hint how to properly use this functionality? Thanks a lot for help. Regards, M.
Last updated: 2023-12-02
Post by simotion on Inheritance of axis
CODESYS Forge
talk
(Post)
I have developped a function block 'Axis' the inherits from 'AXIS_REF_SM3' -> FUNCTION_BLOCK Axis EXTENDS AXIS_REF_SM3 In my global variable list I define a variable MasterDrive of type Axis and assign Axis1. Axis1 is a virtual drive (AXIS_REF_VIRTUAL_SM3). This type should inherit from AXIS_REF_VIRTUAL. VAR_GLOBAL MasterDrive : Axis := Axis1; However I get the error 'Cannot convert type'. What is the way to obtain what I want : function block inheriting AXIS_REF_SM3 and initialising this function block with a Softmotion virtual or real axis?
Last updated: 2023-12-07
Post by voffi on Converting UINT into bytes and converting 2Bytes into UINT
CODESYS Forge
talk
(Post)
There are some ways. One is to use SHR and SHL and it depends on your byte order in the data array. For Motorola byte order: PROGRAM PLC_PRG VAR u : UINT; byte_array_in : ARRAY [1..8] OF BYTE := [16#11, 16#12, 16#13, 16#14, 16#15, 16#16, 16#17]; byte_array_out : ARRAY [1..8] OF BYTE; END_VAR u := SHL(TO_UINT(byte_array_in[2]), 8) + TO_UINT(byte_array_in[1]); byte_array_out[1] := TO_BYTE(u); byte_array_out[2] := TO_BYTE(SHR(u, 8)); If it's Intel byte order just change 1 and 2 in the array indexes.
Last updated: 2023-12-07
Post by nz-dave on Bool turning on in case stament in wrong state?
CODESYS Forge
talk
(Post)
I have a case statement running a process. during one of the steps it has started calling a bool var that is 2 steps further on in the case? i have even tried //commenting it out but it still turns on at the same point in the case. i have also run a trace but cant see anything that would trigger it. Any Ideas? Cheers
Last updated: 2023-12-15
Post by macros8 on Translation - How to get text as reference in Frames translated?
CODESYS Forge
talk
(Post)
Hi, one more point. I have been able to create Property of Text which is added to Global text list so it´s fine. But as soon as I use Frame configuration I lose all other properties but some very basics. I need to have still possibility to set Input configuration because my element is Button. Do you know how to make visible all standard properties + my own properties created in Frame configuration? Thanks a lot. M.
Last updated: 2024-01-03
Post by tvm on SEND_RECV_MSG function block on Schneider Machine Expert
CODESYS Forge
talk
(Post)
Anyone else using the SEND_RECV_MSG function block for RS-485 communication on Schneider Machine Expert? I have had ongoing issues with it for several years, which Schneider tech support is aware of, but hasn't been able to fix. The latest version of Machine Expert (v2.2) appears to have broken some of the functionality altogether. I'd be interested in hearing from anyone else using this platform for serial communication.
Last updated: 2024-01-03
Post by tvm on multiply gives negatives
CODESYS Forge
talk
(Post)
It's probably because you have an INT in the input to the MUL function, which will then try to output an INT as well. INT variables can only handle values of -32768 to 32767. Your value of 523000 won't fit in an INT, so it turns into an invalid number. Use a DINT. This is usually better for working with time values anyway, because time values are all 32 bit. Or if you can't, use INT_TO_DINT(gvlp.detectie_nalooptijd_s) in the input to the MUL function.
Last updated: 2024-01-04
Post by usacodesysuser on How to connect serial devices ?
CODESYS Forge
talk
(Post)
@eschwellinger do you have any examples of using a USB barcode scanner? I have read through the forums here and I am unable to find how to get the barcode data to populate in a text field without having to first click into the text field to activate it. Is there a library that allows you to access the barcode data? I am really new to this in general any help is greatly appreciated, hopefully you have a pretty clear example
Last updated: 2024-01-06
Post by apurv on Cannot pass array of constant size to a function as a reference
CODESYS Forge
talk
(Post)
I have a Array of constant size defined like this Var Constant MAX_SIZE :UINT := 10; End_var VAR array : ARRAY[0..MAX_SIZE] OF INT; END_VAR Now I want to pass this array to a function by reference, Function fun : INT VAR_IN_OUT CONSTANT MAX_SIZE : UINT; END_VAR VAR_INPUT array : REFERENCE TO ARRAY[0..MAX_SIZE] OF INT; END_VAR but when I run this it gives strange Errors Error : Cannot Convert type 'ARRAY [0..MAX_SIZE] OF INT' to type 'ARRAY[0..MAX_SIZE] OF INT'
Last updated: 2024-01-07
Post by eschwellinger on Edge Gateway online, but PLC is not online
CODESYS Forge
talk
(Post)
we need some logfiles from the edge gateway /etc/Gateway.cfg [CmpLog] CmpEdgeGateway.Filter=0xFFFFFFFF Logger.0.Name=/tmp/codesysedge.log Logger.0.Filter=0x0000000F Logger.0.Enable=1 Logger.0.MaxEntries=100000 Logger.0.MaxFileSize=5000000 Logger.0.MaxFiles=1 Logger.0.Backend.0.ClassId=0x00000104 ;writes logger messages in a file Logger.0.Type=0x314 ;Set the timestamp to RTC and does the scan via Automation Server show the plc?
Last updated: 2024-01-09
Post by felipemsgarcia on Edge Gateway online, but PLC is not online
CODESYS Forge
talk
(Post)
Hello, I couldn't figure what/where the issue was, so I deleted everything from automation server and reinstalled the edge gateway and did the process again. It worked for about a month and then it stopped working again. It presents the same symptom, edge gateway is online but I can't connect to the PLC. Any idea of what could be the issue? Thank you!
Last updated: 2024-01-09
Post by felipemsgarcia on Edge Gateway online, but PLC is not online
CODESYS Forge
talk
(Post)
Hi Edwin, The PLC is already in the automation server so nothing happens when I scan the network, however the PLC show offline (not connected). Please see logs below. [CmpLog] Logger.0.Name=codesysedge.log Logger.0.Filter=0x0000000F Logger.0.Enable=1 Logger.0.MaxEntries=100000 Logger.0.MaxFileSize=1000000 Logger.0.MaxFiles=1 Logger.0.Backend.0.ClassId=0x00000104 ;writes logger messages in a file Logger.0.Type=0x314 ;Set the timestamp to RTC Thank you!
Last updated: 2024-01-09
Post by toby on SM Drive license error
CODESYS Forge
talk
(Post)
Hi albert1999 and forest, I hope you are well. I too am wondering if you have found any solutions? Im working with a RPi and a Omron R88D-ETH servo amplifier. The SoftMotion is timing out after 30min without the license, but I cant figure out how to license it, and I seem to have some compatibility issues between my RPi license and any SoftMotion licenses. Did you guys have any luck? Thank you very much for any assistance offered. Toby
Last updated: 2024-01-10
Post by sturmghost on Visualization using methods and cyclic ST-calls
CODESYS Forge
talk
(Post)
I found a way to do it: You can use, for example, the text variable property of any visualization element and call a function in it. Example: Write a test POU as a function (FUN), like MyTestFun which need a boolean Variable as an input value. Now write into the text variable property: MyTestFun(bBooleanValue) Thats it. The function is called at each visu_task cycle.