Post by gatto on Two licenses have to be installed forgot to enable one license
CODESYS Forge
talk
(Post)
Hi. What type of PLC do you have? What activation method do you use? What license ticket did you purchase and want to activate? Can you describe the process you followed step by step?
Last updated: 2026-02-02
Post by yoeri on Python script: Launch Codesys, Execute Script, Exit Codesys
CODESYS Forge
talk
(Post)
For whoever finds this old thread. Instead of System.exit(0), use system.exit(0) without capital 'S', this worked for me. I use these imports from future import print_function import sys import os
Last updated: 2026-02-12
Post by risele on AI + Programming
CODESYS Forge
talk
(Post)
It's already fine to use, with help of exporting/importing as PLC_Open, at least CODEX is good in editing directly at XML and/or providing changes description separately.
Last updated: 2026-02-13
Post by pernockham on Unable to deploy "Control for Linux SL 4.18.0.0"
CODESYS Forge
talk
(Post)
Downloaded and installed edge gateway 4.19.0.0. Unfortunately same behavior: "Control for Linux SL" NOT shown in drop lists on either "Deployment" Tab of tool "Deploy Control SL", or as "installed packages" on "Operation" tab (only "CODESYS Edge Gateway for linux" is shown).
Last updated: 2026-02-16
Post by pernockham on Unable to deploy "Control for Linux SL 4.18.0.0"
CODESYS Forge
talk
(Post)
Am I alone in this? Is this a known fault? Should I look for the reason of the lacking update option for "Control for linux SL" in my system or is it a potential fault in the codesys system?
Last updated: 2026-02-17
Post by patrik on Wish: CODESYSControl.cfg - again
CODESYS Forge
talk
(Post)
Really good post. I hope that it gets seen by CoDeSys staff. I often find the documentation lacking when it comes to using CoDeSys in more complex ways. If using standard "basic PLC functionality", then it's fine and functions are documented in a sufficient way. Once you go outside of that bubble then I find the documentation not enough. CODESYSControl.cfg is a good example of this. And why isn't more of this integrated in the IDE. like changing port of the webserver. Why is it hidden in this file and not accessible through the IDE. It feels like a layer of complexity purposely left in so you don't change it if you don't know what you are doing. Like the argument is if you have the know-how to find the file you have the know-how to edit it. I find the documentation lacking when it comes to more complex libraries too. Like the element collections library. there is parameters I still don't quite know what they do. I can't find any documentation about them. There is an example project to download from CoDeSys so you can see how you are supposed to set your factories up. I leave some parameters like it is in the example. Should I? I don't know. Does it work. Yes. But I could perhaps create memory leaks if I get something wrong and I don't see that until way later. In the create method of your element factory you have a function called __vfinit and you just have to accept that it works. Why can't I get insight in what it does through documentation? Don't CoDeSys want us to know how these work so we can't use them to accidentally break something? I find the error logging lacking too. I've had the CoDeSys service crash but it doesn't say why. I've seen windows noticing the crash but no error code was sent or error message. Also in my current issue where the application fails to start after power outage. I can see in the log that it fails to load retain in the application as one log entry and application failing to start as another. But why? Why does loading the retain fail? give me more information! Is it just a skill issue with me? I don't know. If it is then I'd still want CoDeSys to step up their game when it comes to documentation. I'm sorry if a lot of frustration comes though in this post. I really like the product and what I can do with it compared to other PLC brands.
Last updated: 2024-11-21
Post by gmau on Station 'xyz': AR aborted by device (alarm.ind): AR consumer DHT expired
CODESYS Forge
talk
(Post)
Hello, I am writing to You with the problem of Profinet communication in my Codesys V2.5 SP21 project working on Codesys Control RTE V3 x64 device. I have implemented multiple Profinet devices in the network, the Profinet itself is configured properly, based on the hardware and software parameters of the industrial PC (Windows 10 IoT). My Profinet network contains such Profinet devices as a robot, IO-Link master with some devices on it, IO modules, safety, vision sensor (the configuration is attached to this topic). Once every few hours, sometimes more often, sometimes not even once a day, the error show up at one, two or a few random modules at the same time, every one is the same: "Station 'xyz': AR aborted by device (alarm.ind): AR consumer DHT expired". The communication is then lost with that module, but it is up instantly. It is not such a problem when it comes to regular IOs, but with safety or rotation table, it causes errors and machine stops. I have tried multiple solution based on any forum suggestions, manuals, etc., but it is still happening. Mabye when I turned on the Watchdog for this communication, it is happening less times, but still, I could not turning up the Watchdog parameters at the expense of cycle time of the process. The same is with Send Clock, Reduction and DHT. I have one of the ethernet port on the PC configured with CmpEt1000Drv driver. The card itself is Intel Ethernet Connection I219-LM. These devices are connected to one EKI-2728-NI-A Profinet switch (it was changed from the standard non Profinet one, but still nothing has changed). As I said ealier, I am attaching all the configurations for each device and the communication itself - if any of You had the same problems or have any ideas what could be the cause, I would be much gratefull for any help. For now I am out of ideas, if You have any additional question, please ask. Sincerely, PF
Last updated: 2025-09-04
Post by smeitink on Timeout Error in Modbus Communication with WAGO PFC200 and iEM2050 Meter using 750-652 Module
CODESYS Forge
talk
(Post)
Hi all, I'm looking for help with an issue I've come across while trying to facilitate Modbus communication between a WAGO PFC200 PLC using a 750-652 communication module and an iEM2050 Series Single Phase Energy Meter. I believe to have everything wired and setup correcty, but I keep running into a "Error time out" message, and by now I don't really know what else to try. My setup is as follows: A PFC200 Wago PLC, which has 2 750-652 Serial Interfaces extension modules connected to its field bus. I'm using one of these to talk to a Schneider iEM2050 - kWh-meter over modbus. I have connected terminal 23 (A) of the iEM2050 to connector 6 (A) on the 750-652. I have connected terminal 24 (B) of the iEM2050 to connector 2 (B) of the 750-652. I'm using 200mm of twisted together wires to connected them both, and I have placed a 120 ohm resistor between A and B at both ends. I've attached relevant pinout images to this post. I then wrote a simple program that configures the Mobus port, as per the datasheet of the iEM2050. You can find an image of the relavent page attached to this post too. This is my program: PROGRAM PLC_PRG VAR Master: FbMbMasterSerial; xIsConnected: BOOL; xError: BOOL; iIndex: INT := 1; xTrigger: BOOL; utQuery : typMbQuery := ( bUnitId := 1, // The Modbus unit or slave address bFunctionCode := 4, // Function code for reading input registers uiReadAddress := 1829, // adress for the Power on off counter uiReadQuantity := 1 // Quantity of registers to read ); iStep: INT; oStatusModbus: WagoSysErrorBase.FbResult; utResponseModbus: typMbResponse; xConnect: BOOL := FALSE; delayTimer: TON; END_VAR Master( xConnect:= xConnect, I_Port:= _750_652_24_1, udiBaudrate:= 9600, usiDataBits:= 8, eParity:= WagoTypesCom.eTTYParity.Even, eStopBits:= WagoTypesCom.eTTYStopBits.One, eHandshake:= WagoTypesCom.eTTYHandshake.None, ePhysical:= WagoTypesCom.eTTYPhysicalLayer.RS485_HalfDuplex, xIsConnected=> xIsConnected, xError=> xError, oStatus=> oStatusModbus, eFrameType:= WagoAppPlcModbus.eMbFrameType.RTU, tTimeOut:= T#5S, utQuery:= utQuery, xTrigger:= xTrigger, utResponse:= utResponseModbus); delayTimer(IN := TRUE, PT := T#3S); // Use the Q output of the timer to set xConnect after the delay IF delayTimer.Q THEN xConnect := TRUE; END_IF CASE iStep OF 0: //Wacht totdat de master de poort geopend heeft IF xIsConnected THEN iStep := 1; END_IF 1: //Stuur request naar de slave xTrigger := TRUE; iStep := 2; 2: //Wacht totdat de master klaar is met het afhandelen van de request IF NOT xTrigger THEN iStep := 3; END_IF END_CASE The TON delay before opening the port is due to a an error I encountered when opening it straight away. This seems to be a bug, as described here. However, the TON solved that particular issue. I tried reading multiple registers, but like I said, I still always end up with the "Error time out". What else can I test or try at this point?
Last updated: 2024-02-24
Post by mubeta on Some 'pathetic' errors in SoftMotion program
CODESYS Forge
talk
(Post)
Yes, this is the error the sometimes show up. What make me crazy is the fact that it happens randomly and not each times. I know very well where the problem is, in wich one program row it's located. For each actions of the state machine I have all events recorded with log on text file. it is not problematic for me to find the application point of the fault, but I need to understand why occasionally and for no apparent reason, switching the state machine and thus changing the motion FB, sends the axis into failure (but only occasionally). For example, one case that is often problematic is the execution of the Axis Halt instruction. When, after a MoveAbosulte instruction this returns the event as 'done' and indeed the axis is in standstill, the state machine first sets the move instruction to FALSE, and the next cycle sets the Halt request to TRUE. Some of the time everything works out fine. Occasionally, however, in this exchange, the axis goes into fault, also losing the OPERATIONAL state. Meanwhile, I would like to understand why the motion FB instances must still be called even after the Execute is set to FALSE, especially in view of the fact that the next instruction is programmed to abort the previous one, with BufferMode set to 'Aborting'. All these unnecessary FB calls are an unnecessary overhead on the CPU anyway. Is there any precise rule about when to cease calling the various instances? (It should precisely be the 'done' status that says this one has finished its work).
Last updated: 2024-07-18
Post by otbeka on CAA File Handling: "Read only" error
CODESYS Forge
talk
(Post)
Hi, On CODESYS V3.5.19.50 I am using the latest 3S File Access library (CAA File & CAA Types) to save and retrieve configuration data from the User Data section of an SD card, via file called config.txt. The application reads the file to memory once upon initialisation, and then the only other operation is overwriting the file with the updated configuration whenever the user changes the settings. An issue is ocurring, seemingly randomly, where the config.txt file, and all surrounding directories, cannot be written to by the unit, returning a READ_ONLY_CAA error upon file open. This sometimes does not clear even after power-cycling the PLC several times, yet checking the file permissions with ls -l shows normal read, write, and execute access. I am wondering if this is caused by the PLC itself or by an issue in my application. I have included my CAA File handler function block (SD_Card_Bin(FB).txt) and any associated types/calls below: TYPE ConfigData : STRUCT Config : ARRAY[0..256] OF STRING(64); NumberOfStrings : UDINT; END_STRUCT END_TYPE TYPE Buffer : STRUCT Data : ARRAY[0..SIZEOF(ConfigData)] OF BYTE; DataLength : UDINT; END_STRUCT END_TYPE A case within my MAIN PRG: mode.WriteConfigDataToFile: VisuElems.CURRENTVISU := 'Screen_Write'; IF xModeHasChanged THEN iErrorCount := 0; iRoute := 0; END_IF CASE iRoute OF 0: inBuffer := ConfigData_To_Buffer(GVL.UnitData); xConfigError := FALSE; xDataConfigured := FALSE; iRoute := 1; 1 : //Read Data from Card SD_Card_Bin.strFileName :=FileName; SD_Card_Bin.iFileOperation := 2; SD_Card_Bin(xExecute :=TRUE, WriteBuffer := inBuffer, xDone =>xDataConfigured, xError=>xConfigError, strErrorCodes=>strError); IF xDataConfigured THEN SD_Card_Bin(xExecute :=FALSE); IF xConfigError THEN iRoute := 32767; ELSE iRoute :=100; END_IF END_IF 100: // The end bCurMode := mode.DisplayProcessVariables; 32767: // Config error iErrorCount := iErrorCount + 1; IF iErrorCount > 2 THEN // Repeats 3 times, if no progress abandons and returns error bCurMode := mode.WriteError; ELSE iRoute := 0; // Try again END_IF END_CASE I'd like to rule out my application as the cause of this bug - help via comments or criticism would be greatly appreciated.
Last updated: 2025-03-19
Post by manuknecht on Maximum dynamic limits of MC_MoveLinearAbsolute and MC_MoveLinearRelative
CODESYS Forge
talk
(Post)
Hello all I use an axis group with two linear axes in a kinematic system. Using MC_MoveLinearAbsolute and MC_MoveLinearRelative, I am trying to realise dynamic movements (set velocity: 1 m/s, set acceleration: 30 m/s^2) with the highest possible jerk, as I want to compare this with a movement with a trapezoidal velocity profile. However, my measurements show that the axes accelerate with a maximum jerk of approx. 800 m/s^3, even if the value in the function block was set to 10,000 m/s^3. I have already increased the dynamic limits of the two axes accordingly (Velocity: 5000 u/s, Acc-/Deceleration: 250'000 u/s^2, Jerk: 100'000'000 u/s^3, where 1 u = 1 mm), but this had no effect. I have checked the input parameters of the function blocks and the VelFactor, AccFactor and JerkFactor factors are all set to the maximum (value 1). Reducing the cycle time has resulted in a higher jerk, but as we are already working with a cycle time of 1 ms, there is nothing more that can be done here. The axes themselves are still a long way from drawing the maximum current, which is why I assume that this should not be a problem either. Are there other factors or parameters that influence the dynamic limits and therefore allow faster movements? The PLC I am using is a Raspberry Pi 4 and Codesys V3.5 SP20 with all libraries up to date. Thanks in advance Manuel
Last updated: 2024-05-08
Post by hwillems on Ranges, Lambdas, on Fixed arrays of structs
CODESYS Forge
talk
(Post)
I do datastructures and algorithms in Codesys. For example a Struct of Person with thing's like IdNumber, Name, Age etc. as example. Now i do all kind of calculations, filters. So i have this pretty big Fixed Array with Structs. On this struct i want to do simple stuff you can do easily in C++/Python/Rust etc. For example i want to do this: AvererageAge := Average(Peoples.Age); Then it will return the average of all members ages. Or Sort struct on age etc. Or sort on alphabetical Name. Or use Lambda functions to filter/mutate out things like, filter out everybody above 18 years old. Or remove people who it's name start with "A". Currently i have to write my own custom function for example sorting on Age. And make a super specific function based on that particulare datastructure. Here an Example: (*Before calling this FIlter method, set the mNodeFilterSwitch to the desired filter.*) CASE mNodeFilterSelect OF (********************************[ Status Filters ]***********************************) NodeID: FOR x := ACS_OUT_BEGIN TO ACS_OUT_END BY 1 DO FOR y := ACS_IN_BEGIN TO ACS_IN_END BY 1 DO IF marrNode[y].Status.oiNodeID > marrNode[y + 1].Status.oiNodeID THEN mNodeTemp := marrNode[y + 1]; marrNode[y + 1] := marrNode[y]; marrNode[y] := mNodeTemp; END_IF; END_FOR; END_FOR; Started: FOR x := DES_OUT_BEGIN TO DES_OUT_END BY -1 DO FOR y := DES_IN_BEGIN TO DES_IN_END BY -1 DO IF marrNode[y].Status.oxStarted > marrNode[y - 1].Status.oxStarted THEN mNodeTemp := marrNode[y - 1]; marrNode[y - 1] := marrNode[y]; marrNode[y] := mNodeTemp; END_IF; END_FOR; END_FOR; Starting: FOR x := DES_OUT_BEGIN TO DES_OUT_END BY -1 DO FOR y := DES_IN_BEGIN TO DES_IN_END BY -1 DO IF marrNode[y].Status.oxStarting > marrNode[y - 1].Status.oxStarting THEN mNodeTemp := marrNode[y - 1]; marrNode[y - 1] := marrNode[y]; marrNode[y] := mNodeTemp; END_IF; END_FOR; END_FOR; END_CASE; I have like 30+ of these in the enum. Not really DRY code right? These are custom made bubble sort filters in a function. You pass in the Datastructure, and say what function you want. (This is an enum collection of sorting functions) And then the Array with Nodes of Structs gets ordered. Why can't we have Iterators and Lambda's and build in standard functions like regular languages? Also i use bubble sort because it's the easiest to implement because i can't get this to code DRY. Problem with ST (Even the new one with classes) that it's very limited for programming datastructures and algorithms. Yes you still not want dynamic memory and you need to choose the correct algorithm so you know the most extreme edge cases regarding the time it takes to execute the algorithms.(Real-time execution) How are other people dealing with this? Here for example saw some software using an adjusted ST language and having FOR EACH possibility: https://www.fernhillsoftware.com/help/iec-61131/structured-text/st-for-each.html You can then build your own custom Iterator functions. I wish the IEC 61131-3 standard would be more expressive and having more standard modern features, but still keep close to the fact of no dynamics memory and real-time systems.
Last updated: 2023-08-31
Post by sushela on Latest Temu Coupon Codes [acq615756] All Users
CODESYS Forge
talk
(Post)
Latest Temu Coupon Codes [acq615756] | All Users If you’re an avid Temu shopper or new to the platform, you’re in for a treat. Temu offers incredible savings with their latest coupon codes, and one of the hottest deals right now is the $100 off discount using the code [acq615756]. Whether you're placing your first order or are an existing customer, this coupon code is designed to offer fantastic value. In this article, we will explore all the benefits of using the Temu Coupon Code [acq615756], breaking it down into different categories to ensure you get the most out of this amazing offer. TEMU Coupon $100 Off for Existing Customers {[acq615756]} Existing customers on Temu can now enjoy a massive discount of $100 off their purchases. If you’ve been shopping on the platform for a while and are looking for a great deal, the [acq615756] code is perfect for you. It's rare to find such generous discounts for repeat customers, making this offer one not to miss. Apply the code at checkout and enjoy significant savings on your next order. TEMU Coupon $100 Off First Order {[acq615756]} If you’re new to Temu, there's an even better reason to start shopping now. By using the [acq615756] code, new users can save $100 on their very first order. This is an ideal way to explore the platform’s wide range of products without breaking the bank. Simply enter the code during your first purchase to redeem the discount. TEMU Coupon $100 Off Code {[acq615756]} The [acq615756] code is one of the most versatile coupon codes available. Whether you’re an existing user or a first-timer, this $100 off coupon can be applied to a broad range of products across the Temu platform. Just enter the code at checkout, and enjoy instant savings on your total. TEMU Coupon $100 Off for Existing Customers UK {[acq615756]} For our shoppers in the UK, the [acq615756] coupon code is a fantastic opportunity to save £100 off your next order. Existing customers can make the most of this discount when shopping from the UK. Whether you’re buying clothing, electronics, or household items, use the code at checkout to enjoy the discount and elevate your shopping experience. TEMU Coupon $100 Off New User {[acq615756]} New users on Temu have a golden opportunity to save big on their very first order with the [acq615756] coupon code. If you're hesitant to make your first purchase, this $100 off deal is a compelling reason to start now. With this code, you can buy more products at a reduced price, making your first shopping experience more rewarding. TEMU Coupon $100 Off for Existing Customers 2024 {[acq615756]} Looking for a way to save in 2024 as an existing customer? The [acq615756] code is here to help. This coupon provides an easy way for repeat shoppers to save $100 on any purchase. Make sure to take advantage of this deal throughout the year and enjoy continuous savings while shopping for your favorite products. TEMU Coupon $100 Off Code UAE {[acq615756]} Shoppers in the UAE can also benefit from the [acq615756] coupon code. Whether you are a new or existing customer, this $100 discount is applicable on your purchases. Be sure to apply the code during checkout and enjoy lower prices on a wide range of items available on Temu. TEMU Coupon $100 Off First Order Free Shipping {[acq615756]} In addition to saving $100 on your first order, Temu sweetens the deal by offering free shipping. Use the [acq615756] code when you make your first purchase and enjoy not only significant savings but also free delivery. It’s the perfect way to start shopping on Temu without any hidden costs. TEMU Coupon $100 Off for Existing Customers Free Shipping USA {[acq615756]} For our shoppers in the USA, the [acq615756] code offers an incredible $100 off your purchase, plus free shipping. Existing customers can benefit from this offer to save even more. Enjoy the convenience of home delivery without the extra cost, making your shopping experience smoother and more affordable. TEMU Coupon Code $100 Off + Free Shipping {[acq615756]} This coupon code [acq615756] is more than just a discount; it’s an all-in-one deal. With $100 off and free shipping combined, you can shop to your heart's content without worrying about shipping fees. This offer applies to all users, both new and returning, ensuring that everyone can enjoy amazing savings. TEMU Coupon $100 Off for Existing Customers Canada {[acq615756]} Canadian customers aren’t left out! Existing shoppers in Canada can use the [acq615756] coupon code to get $100 off their order. Temu continues to expand its presence, and this discount ensures that loyal customers in Canada can shop at discounted rates while enjoying a vast array of products. Conclusion The Temu Coupon Code [acq615756] is an exceptional opportunity for all users, offering $100 off across multiple regions, from the UK to the UAE, USA, and Canada. Whether you’re a new customer or have been shopping with Temu for a while, this code provides incredible value, ensuring that you save big on your next purchase. Don’t miss out on the added benefit of free shipping, and make sure to apply this code at checkout to maximize your savings. Start shopping now and take advantage of these amazing offers before they expire!a
Last updated: 2024-10-26
Post by mondinmr on Frustration-Fueled Feedback on Project File Management and Git Integration
CODESYS Forge
talk
(Post)
Good day, I’m writing this message out of frustration regarding the current way project files are saved as encrypted XML and single-file format in CODESYS. I find this approach to be quite tedious for several reasons: Limited Access to Structured Text: Not being able to access Structured Text (ST) externally makes it impossible to work with alternative editors like VSCode. Tools like VSCode are incredibly responsive and feature advanced systems such as GitHub Copilot, which would be a real game-changer when working with ST IEC. While CODESYS works well for small code snippets or debugging, when the codebase grows, switching to VSCode to boost productivity becomes essential, and copy-pasting between environments is a cumbersome workaround. Poor Integration with Git: This file format also makes it very difficult to integrate effectively with Git. I have tested the internal demo, but for advanced merges, it is unusable. Without properly formatted plain text, it’s impossible to leverage the vast ecosystem of external tools around Git that allow smooth merges in heterogeneous teams. File Corruption on Network Drives: I often work from multiple locations with shared network drives. When the development environment saves a file and something goes wrong midway (which can occasionally happen when using VPNs and network drives), the entire project becomes irrecoverable. There’s no way to cancel the save process, and the development environment freezes. This has happened to me at least four times over the past two weeks, and one of those incidents cost me an entire day of work. All of this is particularly disappointing because I truly believe that the libraries, runtime, and overall work done by CODESYS are exceptional. I find it fantastic that there is a platform allowing development of PLCs and control systems using OOP, which is a huge advantage in modern control engineering. I apologize for the rant, but this issue has been extremely frustrating. Best regards.
Last updated: 2024-10-15
Post by mondinmr on Frustration-Fueled Feedback on Project File Management and Git Integration
CODESYS Forge
talk
(Post)
In reality, other vendors are already moving towards integration with VS Code. B&R, for example, is likely the only one that could truly challenge Codesys in the market: they’ve overhauled their once-archaic environment (previously lacking ST OOP) and are now catching up significantly with Automation Studio Code, offering modern programming capabilities and native support for tools like Git and GitHub Copilot. The other big names in the market, frankly, are still light years behind. For smaller projects, typically handled by “wire strippers” (with all due respect!), a classic environment might be just fine. But once you’re dealing with thousands or even millions of lines of code—possibly organized in an OOP paradigm, spanning large teams, integrating third-party libraries, requiring version control, and performing comprehensive tests—a lightweight, responsive editor supercharged with AI-based features becomes essential. The real strength of something like VS Code lies in its vast ecosystem of extensions and integrations: from advanced Git support to automated build/test pipelines, and even AI-assisted autocompletion that already makes software development much more agile and productive. I understand that a PLC project involves more than just ST code (task setup, fieldbus configuration, libraries, etc.). However, there’s no technical reason not to at least provide ST files in a pure text format, making version control and collaboration far easier. B&R has clearly adopted this approach; I hope Codesys will accelerate its own efforts to offer a native, text-based integration and modern development tooling. Once you go beyond a certain level of complexity—dozens of configurations, OOP hierarchies, and distributed teams—you really do need “engineer-level” software tools, not just solutions targeting “wire strippers.” For large-scale automation projects, a more open and flexible approach is the only way to avoid chronic frustration. Let me emphasize that I truly love Codesys and consider the work done so far to be brilliant—I’d be sorry to see it overshadowed by others moving faster in this direction.
Last updated: 2025-02-18
Post by kurtk on SysProcess Execute Command unable to run commands with special characters
CODESYS Forge
talk
(Post)
Thank you for this additional information. Could you please provide the references to the official documentation where you found this information ? I got as far as: Then insert this: [SysProcess] BasePriority=Realtime Command=AllowAll devoid of references of where the CodesysContol.cfg file was located or of the need to run codesys as root I incrementally located bits of information with perplexity searches but remained mired at error 25 ERR_NO_ACCESS I am curious whether root access is MANDATORY to run SysProcessExecuteCommand (- and/or any other SysProcess functions) or if a more access-constrained User=quasiroot could suffice without the security concerns ? Apparently codesys runs fine without User=root for almost everything... That raises the question: What IS the default codesys user ? I notice in the prototypes: VAR sCommand : STRING := '/usr/bin/whoami'; sOutput : STRING(255); refCommand : REFERENCE TO STRING; refOutput : REFERENCE TO STRING; resultCmd : UDINT; END_VAR whenever I attempt to build this Codesys v3.5 SP2 whines that "cannot convert type REFERENCE TO STRING to STRING" don't remember the exact message... Apparently this happens whenever a fixed-length string is involved. if I get rid of (255) and just set the string := ' '; that is sufficient to make the compiler happy. Is this a recently enforced constraint ? Why does this compile for you and not for me ? There are references to functions / utilities which are used/needed to massage the string references - but I see no specific details... I also notice you specify: Make sure the lib SysProcessImplementation, SysTypes, and CmpErrors is on the project. I don't comprehend why all of the dependent libraries are not automatically referenced, added ? I don't recall seeing anywhere but here that SysProcessImplementation must be included... It just seems odd that the default is to exclude essential libraries, or require alchemical conjuring to assemble all the ingredients for gnat soup ;-) Thanks a lot... I'm still a codesys newby getting my wheels on - or sometimes just partially on
Last updated: 2025-09-12
Post by adamrobotic on llcallback() iec exception caught cmpid=0x00000002, eventid=0x00010008
CODESYS Forge
talk
(Post)
Hi All, Recently I have been experiencing a issue in CodeSys SP16 Patch 3, with a exception which comes up after I have made several online changes. callcallback() iec exception caught cmpid=0x00000002, eventid=0x00010008, after I experience this fault then I receive a error message for any subsequent online change "online change failed, no task gap within 10000ms". To recover either the controller needs a orgin reset, which will allow online edits thereafter until falling back into the loop. I am using a TURCK TX707 product which is controlling robot trajectory, We have hard coded the coordinate data rather than using persistence variables so hence the need to do online changes consistently. I have read on the forum other people have experienced similar issue with the online task gap, but I have no task which have same priority and also monitored the CPU usage and have not seen it go above 13%. Anyones help would be much appreciated, thankyou.
Last updated: 2023-08-18
Post by sunfloweeerrry on Edgelogix-rpi-1000-cm4102032 SPI port connection to PiFace I/O Driver in CodeSys.
CODESYS Forge
talk
(Post)
Hello, I hv a problem. Couldn't solve this for 2 days now. So I'm quite new at CodeSys and I have to use the spi port x30 on the edgelogix rpi 1000. So what I have to do is just 'add device' at the SPI where I hv to pick the 'SPI master' after that I hv to change the parameters according to the edgelogix I did found in the spidev.h but nothing got updated so I 'add device' again where I pick the PiFace I/O Driver and I put my variables at the I/O Mapping, which i put the input startbit at the in part and led at the out part. I want to make the led blink according to my structured text code but somehow the hardware didn't connected with the CodeSys spi port. Nothing happens. Any idea what I have to do?
Last updated: 2023-08-18
Post by ofey on Codesys Soft PLC OPC UA server
CODESYS Forge
talk
(Post)
Hi! I'm sorry if this has been asked before. I have tried looking up previous topics regaring this, but even though I'm following tutorials and other posts I cant seem to get this to work consistently. I actually got the connection established on a test project after some trial and error. I only got it to work with the "Anonymous login". But after i deleted the test project and tried to get the same thing to work on another project I cant get it to work anymore. What I'm trying to do: Set up and OPC UA Server using CODESYS with the free soft PLC. I then try to connect to the OPC UA Server with the program "UaExpert". What happens: I get the error Error "'BadUserAccessDenied' was returned during ActivateSession". What I have done in CODESYS: - Added the object "Symbol configuration" and checked some test variables - Checked "Support OPC UA features - In "Communication settings -> device -> Change runtime security policy" I have checked "Allow anonymous login" What I have done in UAExpert: - Found the OPC UA server under "local". (It is showing two servers though, I do not know why. It showed the same when it worked yesterday). Se attachment - Checked "Anonymous" under "Authentication settings in the OPC UA server. I'm new to CODESYS, so it could be something elementary wrong in my settings. Maybe something in the user settings in CODESYS regarding user rights or something?
Last updated: 2023-09-14
Post by sturmghost on Visualization using methods and cyclic ST-calls
CODESYS Forge
talk
(Post)
Im looking for a way to implement ST-code into the visualization element without creating a helper POU or method in my device/application tree. Like visualization properties are evaluated at each VISU_TASK cycle I want to be able to create own ST code which interacts with the visualization interface variables. To be more specific I want to have a property which executes user defined ST-code at each VISU_TASK cycle exactly like its already possible for Input Configuration on various mouse and dialog events. Also a property for initialization (so only executed once) and a timed property would be nice. With the situation right now I'll have to create a POU function which handles the ST-code and misuse a property, like the text variable, to execute this POU function at each VISU_TASK cycle. Or does it exist and I don't know it?
Last updated: 2023-10-02
Post by mavitia on Application based license problem - Modbus TCP
CODESYS Forge
talk
(Post)
I am running ubuntu on a raspberry pi, and installed an application based license Control Basic M on it, it runs a demo program fine, does not timeout etc. however, when I add a modbus TCP device, I start getting errors: <Entry severity="error" component="CmpApp" user="nobody" timestamp="12/18/2023 3:49:42 PM" infoId="24">Online change denied. Application Application is in exception state!</Entry> <Entry severity="error" component="CmpApp" user="nobody" timestamp="12/18/2023 3:49:42 PM" infoId="68">Download failed: Application=Application</Entry> <Entry severity="exception" component="CmpApp" user="nobody" timestamp="12/18/2023 3:49:41 PM" infoId="0">Application app=Application has invalid license metrics!</Entry> the modbus tcp slave runs, and the counter ticks up, however, when I call the variables on the %IX0.0 in my program, and try to upload the changes, I am getting the error messages which stop the program as far as I understand, the application based, M includes 2 fieldbus instances, but on the other side is fairly new, anything obvious I am missing out here?
Last updated: 2023-12-18
Post by lsislsis on SIGABRT Error
CODESYS Forge
talk
(Post)
Please help us. Why we take this errors. We try different versions like 4.12.0 and 4.13.0 with same results. ;*********;<loggername>codesyscontrol.log</loggername>;<logoptions>; <enable>1</enable>; <type>normal</type>; <timestamp>rtc high resolution</timestamp>; <deactivatable>0</deactivatable>; <dump>always</dump>; <filter>0x0000000f<filter>; <maxentries>100000</maxentries>; <maxfiles>1</maxfiles>; <maxfilesize>1000000</maxfilesize>;</filter></filter></logoptions>;<entries>;Timestamp, CmpId, ClassId, ErrorId, InfoId, InfoText;ClassId: LOG_INFO =1;ClassId: LOG_WARNING =2;ClassId: LOG_ERROR =4;ClassId: LOG_EXCEPTION =8;ClassId: LOG_DEBUG =16;ClassId: LOG_PRINTF =32;ClassId: LOG_COM =64;</entries>;*********2024-11-05T08:23:59.728Z, 0x0000100c, 1, 0, 0, VisuFctCheckForUnusedClients: Removing Client with IEC-ID: 1 Time delta: T#33s1ms Locks: Paintbuffer: TRUE 2024-11-05T08:23:59.728Z, 0x0000100c, 1, 0, 0, VisuFctCheckForUnusedClients: Successfully Removed Client at Address: 547195449944, IEC-ID was: 1, EXT-ID: 431000373 2024-11-05T08:28:57.913Z, 0x0000100c, 1, 0, 0, Visu_PRG: Creating Client for Extern-ID: 347055752 2024-11-05T08:28:57.926Z, 0x0000100c, 1, 0, 0, Visu_PRG: Creating Client successful for Extern-ID: 347055752 Returned IEC-ID: 1 2024-11-05T08:30:51.103Z, 0x0000100c, 1, 0, 0, Visu_PRG: Successfully Removed Client with IEC-ID: 1, Extern-ID: 347055752 2024-11-05T08:37:36.517Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state* We recommend a reboot of the controller now! 2024-11-05T08:37:36.517Z, 0x00000111, 8, 260, 3, #### Exception: HANDLED EXCPT <excpt>NonContinuable</excpt> in CH_COMM_CYCLE 2024-11-05T08:47:42.117Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state We recommend a reboot of the controller now! 2024-11-05T08:47:42.117Z, 0x00000111, 8, 260, 3, #### Exception: HANDLED EXCPT <excpt>NonContinuable</excpt> in CH_COMM_CYCLE 2024-11-05T09:14:41.316Z, 0x00000071, 1, 0, 13, Webserver stopped 2024-11-05T09:14:44.485Z, 0x0000013d, 1, 0, 4, Number of licensed cores for IEC-tasks: 1 from 4 2024-11-05T09:14:44.487Z, 0x0000013d, 1, 0, 4, Number of licensed cores for IEC-tasks: 4 from 4 2024-11-05T09:14:44.540Z, 0x00000002, 1, 0, 2, Application [<app>Application</app>] loaded via [Download] 2024-11-05T09:14:55.894Z, 0x00001012, 1, 0, 0, Opened alarm storage file, version: 6 2024-11-05T09:14:55.951Z, 0x0000100c, 1, 0, 0, Visuinitialization starting. 2024-11-05T09:14:55.983Z, 0x0000100c, 1, 0, 0, Visuinitialization done. 2024-11-05T09:14:55.995Z, 0x00000071, 1, 0, 12, Webserver started 2024-11-05T09:15:01.753Z, 0x0000100c, 1, 0, 0, Visu_PRG: Creating Client for Extern-ID: 2279884529 2024-11-05T09:15:01.753Z, 0x0000100c, 1, 0, 0, Visu_PRG: Creating Client successful for Extern-ID: 2279884529 Returned IEC-ID: 0 2024-11-05T09:34:44.667Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state We recommend a reboot of the controller now! 2024-11-05T09:34:44.667Z, 0x00000111, 8, 260, 3, #### Exception: More than 2 exceptions in CH_COMM_CYCLE: Stop logging 2024-11-05T10:13:26.867Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state We recommend a reboot of the controller now! 2024-11-05T10:15:21.966Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state We recommend a reboot of the controller now! 2024-11-05T10:19:12.167Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state We recommend a reboot of the controller now! 2024-11-05T10:26:02.566Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state We recommend a reboot of the controller now! 2024-11-05T10:31:42.866Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state We recommend a reboot of the controller now! 2024-11-05T11:01:54.468Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state We recommend a reboot of the controller now! 2024-11-05T11:09:29.868Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state We recommend a reboot of the controller now! 2024-11-05T11:14:44.540Z, 0x0000100d, 1, 0, 0, Demo mode expired. 2024-11-05T11:27:20.868Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state We recommend a reboot of the controller now! * Regards
Last updated: 2024-11-05
Post by matthew on New Ladder Editor Issues
CODESYS Forge
talk
(Post)
Hi There, When using the new ladder editor there is no option for function blocks to Remove uncalled FB call parameters. I also see no update function block. When you double click the function block it no longer opens the function block. I also now get warnings if I insert FB call without a contact in front. Warning is: (Impl)): C0373: Expression or part of it has no effect I take it the new editor must work differently? The only reason for using new ladder editor is the ST execute/block editing is far better, If you have alot of text in the old ST execute the editor window is very small and when online it's even worse. The new ST block seems a lot better Thanks!
Last updated: 2023-10-10
Post by smartcoco on The text list provided outside the library is not available for visualization controls within the library.
CODESYS Forge
talk
(Post)
I have a project called 'DemoProject' and a library called 'DemoLib'. Create a visual control named "DemoVisu" in the library, with a selection box of type "ComboBoxInteger" in the space. Now 'ComboBoxInteger' requires a 'Text list'. This "Text list" is provided when I call the "DemoVisu" control of the "DemoLib" library in "DemoProject". And this text list is in 'DemoProject'. I found that 'ComboBoxInteger' no longer works at this time. Other visual controls that use text lists also have this issue. I hope there is a good solution to this problem.
Last updated: 2023-10-16
Post by benediktenger on Access project information of references library by script
CODESYS Forge
talk
(Post)
Hi, I need to accesss to project information of a referenced library in the project. At least I need the "Released" flag from these information to check that no project gets shipped with unreleased libraries. Unfortunally, I do not get this information by script. I archieved to get the library reference object and the managed library object but both won't give me this flag but only basic information like company, name, version, etc. Here is my code: # get the library refernces proj = projects.primary objects = proj.get_children(recursive=True) for object in objects: if object.is_libman: for libref in iter(object): if libref.is_placeholder and isinstance(libref.effective_resolution,str): print(libref) print(libref.name) # get the managed libraries libs = librarymanager.get_all_libraries() for lib in libs: print(lib.displayname) print(lib.version) Does somebody know how do get these information?
Last updated: 2023-10-23