Post by dagi89 on CAA File open Problems CODESYS Forge talk (Post)
Dear All, i am using Runtime CODESYS Control Win V3 - X64 Version 3.5.20.40, by using CAA file library (3.5.19.0) seems not fasible to open a file n 'C:\ciao.txt' or others absolute path. The error on File Open is 5114 File Operation Danied.. here below the implemented code and the windows file's properties. I use to implement codesys in RPI and this operation is immediate... Can someone help me in it?? Thanks in advance Dagi89
Last updated: 2024-12-21

Post by paulpotat on Can't find the safety manual in the documentation CODESYS Forge talk (Post)
Hello, I was browsing the "CODESYS Virtual Safe Control for Linux SL" documentation page, and it says the following : For more information about the development of safety-critical applications with CODESYS, see: * Safety Manual H1 – SafetyManual.pdf, which is stored in the directory ../<user>/CODESYS Virtual Safe Control Linux SL/Delivery/Manuals</user> What does this path refers to ? I can't find it in CODESYS installation directories. Best regards
Last updated: 2025-01-23

Post by darko7417 on When running as a service, CodesysControl doesn't write log files to the disk (and other CmpLog related issuess) CODESYS Forge talk (Post)
Wow! Thanks mr Strucc. Changed to service to run as local acc, and now log works! The service (run from local acc) is using this config: C:\Users\SRV\AppData\Roaming\CODESYS\CODESYSControlWinV3\C4DBB537\CODESYSControl.cfg The path you first mentioned (c:\Windows\System32\config\systemprofile\AppData\Roaming) has no CODESYS folder in it (Windows 11 24H2 b26100.3194). Thanks for your help :)
Last updated: 2025-03-06

Post by arwie on Working on exporting/importing projects to PlainText. CODESYS Forge talk (Post)
To better track project changes in git I created a script that exports the project structure as text files. Textual POUs are stored as text, everything else as XML (with timestamps removed). The file structure is stored under path/to/your.project.txt Git merge will not work, but at least tracking changes is much easier. Script: https://github.com/arwie/controlOS_demo/blob/main/codesys/txtfy.py Example output: https://github.com/arwie/controlOS_demo/tree/main/codesys/controlOS_demo.project.txt
Last updated: 2025-07-24

Post by amy123 on CSV Utility CANNOT_OPEN_DIRECTORY CODESYS Forge talk (Post)
Hello, I tried using the CSV Utility SL Example from the CODESYS IIoT Libraries SL. No matter what path I try, I can not get the InitSave to work from CSVWRitersSTExample, line 2. It always gives the error 'CANNOT_OPEN_DIRECTORY'. I am running this on an Windows Azure VM, with Codesys Control Win V3 x64. I added a folder called 'temp' to my C: so that the default 'C:/temp' would work. However it gives CANNOT_OPEN_DIRECTORY. I tried updating to 'C:\temp' with the same result. Any help would be greatly appreciated!
Last updated: 2024-02-14

Post by camilloo on Control for Linux SL on Ubuntu Core CODESYS Forge talk (Post)
(dhumphries) I followed your advice and tried it on Ubuntu Server. Was a good choice. Your material was also very helpful :). Thanks for Your help! I no longer have problems connecting to Ubuntu. However, I still cannot install Virtual PLC. I'm currently getting a missing path message: "C:\Program Files\CODESYS 3.5.19.60\CODESYS\CODESYS Virtual Control for Linux SL\Delivery\virtuallinux\VirtualControlAPI.py." It looks as the package: "CODESYS Virtual Control for Linux SL" was not installed. But, there isn't one in CODESYS Store or I'm doing something incorrectly.
Last updated: 2024-03-03

Post by richard-wang on Codesys recipe manager - what does it do? CODESYS Forge talk (Post)
Hi All Thanks for sharing this information. For whom may not know why always get error code 16#4000 or 16#4002 while performing Recipe commands, the root cause is There is a line need to be inserted in CODESYSControl.cfg file, which is PlaceholderFilePath.1=/var/opt/codesys/PlcLogic/ I am using Pi, therefore the above path is set to my pi unit, after adding above line to my cfg file, all the Recipe commands work fine. But I still do not know how and when this file got modified though.
Last updated: 2024-04-29

Post by micik on CAA File, how to check whether file exists or not CODESYS Forge talk (Post)
Hello, what would be the most efficient way to check whether the file exists or not. I don't want to use file.Open function, it seems like rather inefficiet operaton. I considered GetAttribute function, but this function doesn't accept filename (with path) as an input. Basically I need to check first time when program is loaded to the runtime i.e. when application is started for the first time, whether a file exists on the specific location or not.
Last updated: 2024-05-16

Post by sukrit on What licenses are required for runtime on raspberry pi cm4 CODESYS Forge talk (Post)
We have developed a project for 2 servo motors using raspberry pi computemodule 4 on ethercat master. we are using web visualization for display different screens. project is running well in demo. we want to implement it in production envoirment. being new still wondering which licences i need. Can We get this information in codesys devlopment software. code size is approx 5 mb, 1 instance of etharcat master and aproox 100 variables in visaualization.
Last updated: 2023-10-17

Post by tehthoams on Find Function: Object reference not set to an instance of an object. CODESYS Forge talk (Post)
Hey, Sorry this isn't super helpful, but i had this problem once and was able to resolve it. I can't recall how I solved it and whether it was a problem with my codesys installation or the project itself. If it is the codesys installation, make sure all your required libraries and plugins are installed and available. compare with a colleagues installation if possible. I vaguely recall saving a copy of my project and deleting things one by one until the error went away...
Last updated: 2023-10-30

Post by tehthoams on Find Function: Object reference not set to an instance of an object. CODESYS Forge talk (Post)
Hey, Sorry this isn't super helpful, but i had this problem once and was able to resolve it. I can't recall how I solved it and whether it was a problem with my codesys installation or the project itself. If it is the codesys installation, make sure all your required libraries and plugins are installed and available. compare with a colleagues installation if possible. I vaguely recall saving a copy of my project and deleting things one by one until the error went away...
Last updated: 2023-10-30

Post by vsgn on Passing properties as VAR_IN_OUT variables. CODESYS Forge talk (Post)
Hi, in my experience, the best options for such a case could be: 1. Pass a FunctionBlock via VAR_IN_OUT, containing all variables, mehods and properties needed for the logic of this graphic element (be aware of implementing correcly both get and set accessor for properties) 2. Pass an Interface via VAR_INPUT, of which you can use obviously only Properties and Methods. This is much more elegant for me. Here, you can just pass directly the instance of a FunctionBlock implementing such Interface as input. Hope you'll find this suggestions useful.
Last updated: 2025-05-13

Post by pernockham on Engineering IDE from linux? CODESYS Forge talk (Post)
An update note. Still using linux/Qemu. Still happy, but sometimes some things are harder. I lost the "bridge" connection to my VM (meaning for instance I couldnt "scan network" and find local units. Have spent tons of hours to find out why. Finally it seems the traffic got blocked by the firewall/iptables so needed to set rules for that. So friendly note that rules must allow forward traffic to/from you configured host bridge device.
Last updated: 2025-09-22

Post by yannick on Raspberry PI 5 not working CODESYS Forge talk (Post)
Hello I'm using Codesys V3.5 SP19 Patch 6 and a Raspberry PI 5 4GB Bookworm 32bit with the Runtime 4.11.0.0 SL. I can install the runtime and download the software completly but after a few seconds the connection disconnects with the message no connection to device. Please scan network again. And the object reference was not set to an object instance. See screenshot. Can somebody help me with that? Thanks
Last updated: 2024-04-28

Post by installwhat on C0077 on one machine but not another CODESYS Forge talk (Post)
https://forge.codesys.com/forge/talk/Engineering/thread/92c913bf7c/ Solved by changing the ethercat master version after reading the thread linked above. I think I need to read up on why this happened. I understand that placeholders should point to a particular version for obvious reasons however what has occurred in this instance is different. The example project was released as a "project archive" but it seems to load differently based on what I've got installed in my repositories. I'm going to dig into that tomorrow but any advice is welcome.
Last updated: 2024-06-11

Post by kenth1973 on MC_Phasing state explenation CODESYS Forge talk (Post)
My MC_Phasing FB was stuck in iPhasingState=1 and error output HIGH on one axis. I could manually overwrite the state to 0 in the instance data. During normal run I see the state change from 0 to 10 to 100 back to 0 (maybe more states that I couldnt catch with the naked eye) But - what are the states numbers and their different explenations? This is not explained in the FB guide on codesys. (the pictures show state = 0 after I reset)
Last updated: 2025-11-22

Post by psychoengineer on Cannot Save CSV File on Windows Computer Using CODESYS and Control Win CODESYS Forge talk (Post)
I am currently working on a project using CODESYS and Control Win on a Windows computer. I've encountered an issue where I am unable to save a CSV file. I have followed the standard procedures and used the appropriate file handling functions, but the file is not being created or saved as expected. IF xStartTest THEN sFileName := '\logs.txt'; sFileName := CONCAT(gvl.g_sMainDirectory, sFileName); sFileNameCopy := '\CAAFileCopy.txt'; sFileNameCopy := CONCAT(gvl.g_sMainDirectory, sFileNameCopy); //eWriteState := FILE_OPEN_TRIGGER; xTestDone := FALSE; xError := FALSE; xStartTest := FALSE; END_IF VAR_GLOBAL g_sMainDirectory : STRING := 'C:\LogFiles'; // file path for CSV file END_VAR Despite this, the file does not appear in the specified directory, and no error messages are being generated. I've checked the directory permissions and ensured that the path is correct. Has anyone else experienced a similar issue or have any suggestions on how to resolve this? Any help would be greatly appreciated. Thank you!
Last updated: 2024-07-04

Post by pernockham on Engineering IDE from linux? CODESYS Forge talk (Post)
I have done the switch (linux mint, virtual windows through QEMU/KVM) now and is generally pleased. Have had problems in two areas initially. To bridge IP to the Virtual unit (solved), I overthought things initially. Solution. Configure manually a bridge in the mint-"network connections". Use that bridge in the Qemu settings as "Bridge device", "Device name": "name of the configured bridge" Figure out where to store the projects. I started out have the data in linux world (sort of) and linking it the windows with "virtio-fs". That had some serious impact though on git-handling. It seems that virtio-fs interpreted any file-path as lowercase only even if there were uppercase, resulting in git not able to sync files between its repository and the source code (it created a new file-path for me with only lowercase). Then I switch to samba-share instead and this works much better, though (git-actions) is a part that still has low performance with lots of waiting for file-actions. What should be the best way of handling the source/git? Edit to answer myself: Save the project "locally" in windows, then a lot of slow performance is avoided. Then a git-remote sync for backup.
Last updated: 2025-05-08

Post by micik on Python scripting - print whole project tree CODESYS Forge talk (Post)
Hello, I have found a script for printing device tree in Codesys project. This script is available as code snippet as an exmaple for using Python in Codesys. However I feel main documentation is lacking. For example, where can I find that object has "is_device" attribute? Code examples are given here: https://content.helpme-codesys.com/en/CODESYS%20Scripting/_cds_access_cds_func_in_python_scripts.html However, I have a question how to print the whole Project tree and not just devices? Of course I need to remove check: if treeobj.is_device: But simply removing this test condition will not produce what I want. I need to print PLC Logic, Application, ad other nodes in the Project tree. Where to find this documentation?
Last updated: 2024-08-12

Post by timvh on Current Visu name without Current Visu Variable CODESYS Forge talk (Post)
To get the current visu for all your individual web clients, you could iterate over them, using the same library 1) Create a new function block which implements VU.IVisualizationClientIteration 2) Create an instance of this function block + add an instance of the "iterate" function block fbIterateCallBack : FB_IterateOverClients; // this implements VU.IVisualizationClientIteration fbVuIterate : VU.FbIterateClients; // this FB iterates over all clients 3) Call the fbVuIterate and set the reference to the call back FB. Then it will automatically call the method "HandleClient" of this function block. fbVuIterate( xExecute:= NOT fbVuIterate.xDone, xDone=> , xBusy=> , xError=> , itfClientFilter:= VU.Globals.OnlyWebVisu, eError=> , itfIterationCallback:= fbIterateCallBack); In the HandleClients method you can use the property of the interface of your webclient to which page it is currently on: sCurrentVisuOfClient := itfClient.CurrentVisuName; 4) Optionally from here you could also set the visu for the webclient, but this might be obsolete, because the other function block is now available... xQueryOK : BOOL; xChangePage : BOOL; itfVisuClientRawData : VU.IVisualizationClientRaw; xQueryOK := __QUERYINTERFACE(itfClient, itfVisuClientRawData); IF xQueryOK AND xChangePage THEN VisuElems.g_VisuManager.SetMainVisu(pClientData := itfVisuClientRawData.ClientDataPointer, stVisu := 'Visu2'); xChangePage := FALSE; END_IF
Last updated: 2025-08-13

Post by denizerm on Deploy Control SL cant find Podman CODESYS Forge talk (Post)
Hello, CODESYS seems to have problems finding the container engine. In the "Deploy Control SL" window, after connecting via ssh, it simply says: [INFORMATION] Connected successfully! [INFORMATION] Successfully connected to target (192.168.4.199) [WARNING] Error detecting container architecture running podman info yields normal results. My podman info output is as follows: home/Admin$ podman info host: arch: amd64 buildahVersion: 1.35.3 cgroupControllers: - cpu - memory - pids cgroupManager: systemd cgroupVersion: v2 conmon: package: Unknown path: /usr/bin/conmon version: 'conmon version 2.1.10, commit: affab49967eb62f75d2a47398344ab053326289f' cpuUtilization: idlePercent: 99.36 systemPercent: 0.3 userPercent: 0.34 cpus: 4 databaseBackend: sqlite distribution: codename: scarthgap distribution: redagv version: 1.0.0 eventLogger: journald freeLocks: 2040 hostname: secure-automation-os idMappings: gidmap: - container_id: 0 host_id: 1000 size: 1 - container_id: 1 host_id: 100000 size: 65536 uidmap: - container_id: 0 host_id: 1100 size: 1 - container_id: 1 host_id: 100000 size: 65536 kernel: 6.6.65-intel-pk-standard linkmode: dynamic logDriver: journald memFree: 6115598336 memTotal: 8086278144 networkBackend: cni networkBackendInfo: backend: cni dns: {} ociRuntime: name: crun package: Unknown path: /usr/bin/crun version: |- crun version 1.14.3.0.0.0.8-89d44-dirty commit: 89d44467e3b410b73f2065756a12789be45b855b rundir: /run/user/1100/crun spec: 1.0.0 +SYSTEMD +SELINUX +APPARMOR +CAP +SECCOMP +EBPF +YAJL os: linux pasta: executable: /usr/bin/pasta package: Unknown version: "" remoteSocket: exists: true path: /run/podman-shared/podman.sock security: apparmorEnabled: false capabilities: CAP_CHOWN,CAP_DAC_OVERRIDE,CAP_FOWNER,CAP_FSETID,CAP_KILL,CAP_NET_BIND_SERVICE,CAP_SETFCAP,CAP_SETGID,CAP_SETPCAP,CAP_SETUID,CAP_SYS_CHROOT rootless: true seccompEnabled: true seccompProfilePath: "" selinuxEnabled: false serviceIsRemote: true slirp4netns: executable: /usr/bin/slirp4netns package: Unknown version: |- slirp4netns version 1.2.0-beta.0+dev commit: unknown libslirp: 4.7.0 SLIRP_CONFIG_VERSION_MAX: 4 libseccomp: 2.5.5 swapFree: 0 swapTotal: 0 uptime: 1h 36m 10.00s (Approximately 0.04 days) variant: "" plugins: authorization: null log: - k8s-file - none - passthrough - journald network: - bridge - macvlan - ipvlan volume: - local registries: localhost:5000: Blocked: false Insecure: true Location: localhost:5000 MirrorByDigestOnly: false Mirrors: null Prefix: localhost:5000 PullFromMirror: "" search: - localhost store: configFile: /home/serviceuser/.config/containers/storage.conf containerStore: number: 2 paused: 0 running: 2 stopped: 0 graphDriverName: overlay graphOptions: {} graphRoot: /data/containerfiles graphRootAllocated: 119952025600 graphRootUsed: 13801246720 graphStatus: Backing Filesystem: extfs Native Overlay Diff: "true" Supports d_type: "true" Supports shifting: "false" Supports volatile: "true" Using metacopy: "false" imageCopyTmpDir: /var/tmp imageStore: number: 4 runRoot: /run/user/1100/containers transientStore: false volumePath: /data/containerfiles/volumes version: APIVersion: 5.0.2-dev Built: 1711987427 BuiltTime: Mon Apr 1 16:03:47 2024 GitCommit: bb81e85a430fa95d23a15b77c717fd68bf06ebf2 GoVersion: go1.22.12 Os: linux
Last updated: 2025-10-22

Post by bertus on Can't get SMC_SmoothPath to work CODESYS Forge talk (Post)
Hello all, I am trying to run a XY trajectory from a static G-Code file. Everything works except the smoothing/blending of the corners. My setup: Codesys v3.5sp18 Raspberry Pi 4 CODESYS Control for Raspberry Pi SL, using demo license. Zero axes (only using the interpolator). The order of processing for my decoding is: SMC_NCDecoder (ok) SMC_SmoothMerge (ok) SMC_SmoothPath (not ok) SMC_LimitDynamics SMC_CheckVelocities I created following instances and buffers: fbNCDecoder: SMC_NCDecoder; fbSmoothMerge: SMC_SmoothMerge; fbSmoothPath: SMC_SmoothPath; fbLimitDynamics: SMC_LimitDynamics; fbCheckVelocities: SMC_CheckVelocities; aNCDecoderBuffer: ARRAY[0..49] OF SMC_GeoInfo; // buffer stage 1 (fbNCDecoder) aSmoothMergeBuffer: ARRAY[0..19] OF SMC_GeoInfo; // buffer stage 2 (fbSmoothMerge) aSmoothPathBuffer: ARRAY[0..99] OF SMC_GeoInfo; // buffer stage 3 (fbSmoothPath) aLimitDynamicsBuffer: ARRAY[0..39] OF SMC_GeoInfo; // buffer stage 4 (fbLimitDynamics) My original G-Code file has a lot of short G1 elements but this example, I reduced it to a simple square: N000 G51 D10 N010 G38 O1 N020 G00 X0 Y0 F50 E1000 E-1000 N030 G01 X0 Y-37.5 N040 G01 X-75 Y-37.5 N050 G01 X-75 Y37.5 N060 G01 X0 Y37.5 N070 G01 X0 Y0 N080 G50 N090 G39 O1 In the Codesys CNC settings, I have these instances activated: SMC_SmoothMerge SMC_SmoothPath SMC_LimitDynamics SMC_CheckVelocities And with those settings (and the path-preprocessing button actived), the G-Code viewer shows the square with nicely blended corners (see attached picture). However, when running it on the PLC, it doesn't blend the corners at all. Below the relevant part of my code. The process is started with bDecode. // stage 1: decoding G-code fbNCDecoder( ncprog := square, bExecute:= bDecode, bAbort:= NOT bDecode, nSizeOutQueue := SIZEOF(aNCDecoderBuffer), pbyBufferOutQueue := ADR(aNCDecoderBuffer) ); // stage 2: merge short linear segments fbSmoothMerge( bExecute := bDecode, poqDataIn := fbNCDecoder.poqDataOut, nSizeOutQueue := SIZEOF(aSmoothMergeBuffer), pbyBufferOutQueue := ADR(aSmoothMergeBuffer), piMaxDifference := PI_MAX_DIFFERENCE, usiMaxDegree := 5, wFeatureFlag := 1, wAdditionalParamNumber := 0, dMinimumCurvatureRadius := D_MIN_CURVATURE_RADIUS ); // stage 3: smooth corners fbSmoothPath( bExecute := bDecode, bAbort := NOT bDecode, poqDataIn := fbSmoothMerge.poqDataOut, eMode := SMC_SMOOTHPATHMODE.SP_SPLINE5_MIN_CURVATURE, eAddAxMode := SMC_SMOOTHPATHADDAXMODE.SPAA_NONE, nSizeOutQueue := SIZEOF(aSmoothPathBuffer), pbyBufferOutQueue := ADR(aSmoothPathBuffer), dAngleTol := D_ANGLE_TOL, bSymmetricalDistances := TRUE, bImprovedSymmetricCuts := TRUE ); // stage 4: keep acc/dec and velocity within limits fbLimitDynamics( bExecute := bDecode, bAbort := NOT bDecode, poqDataIn := fbSmoothPath.poqDataOut, wAxis := 16#07, nSizeOutQueue := SIZEOF(aLimitDynamicsBuffer), pbyBufferOutQueue := ADR(aLimitDynamicsBuffer), bIncludePathSettings := TRUE, dMaxVel := 2500, dMaxAccDec := 10000 ); // stage 5: check the path speed fbCheckVelocities( bExecute := bDecode, bAbort := NOT bDecode, poqDataIn := fbLimitDynamics.poqDataOut, dAngleTol := D_ANGLE_TOL); pathQueue := fbCheckVelocities.poqDataOut; // repeat until MaxDuration ... Any idea what I'm doing wrong? Is smooth path supposed to work at all when using a demo license? Thanks.
Last updated: 2025-12-17

Post by felipemsgarcia on Edge Gateway online, but PLC is not online CODESYS Forge talk (Post)
Hello, Up until yesterday (2023/11/20) I was able to connect to the PLC remotely with no issues through Edge Gateway. However, today I can see the Edge Gateway online but I can find the PLC even if I do a network scan. Following the same path as janber0206 @ https://forge.codesys.com/forge/talk/automation_server/thread/e78b11d7e9/, I looked into certificates and found that one of the Trusted publisher certificates has expired earlier today (2023/11/21). Please see image. Questions are: Does it affect the connection to the PLC through Edge Gateway? How do I fix it? Thank you very much in advance!
Last updated: 2023-11-21

Post by gatto on CAA File open Problems CODESYS Forge talk (Post)
Ciao, here same question https://forge.codesys.com/forge/talk/Engineering/thread/2538729618/ in this post https://forge.codesys.com/forge/talk/Engineering/thread/4586a90290/?limit=25#d531 i find : keep in mind that all files which are generated / or read should be exist in the iecfilepath this means: for Windows (Control Win as example) c:\ProgramData\CODESYS\CODESYSControlWinV3x64\268E8ADF\PlcLogic for Linux /var/opt/codesys/PlcLogic I never use codesys on windows but im sure on linux we can manipulate file only inside /var/opt/codesys/Plc Logic. Or you need to modify the file codesyscontrol.cfg for change path permission, but this is another history Buone feste !
Last updated: 2024-12-21

Post by jzhvymetal77 on VarAccGetAddress does not return the correct address for TYPE_ARRAY or TYPE_USERDEF. CODESYS Forge talk (Post)
VarAccGetAddress does not return the correct address for TYPE_ARRAY or TYPE_USERDEF. When you use VarAccGetNode, it returns a proper IBaseTreeNode if you provide the full path of an array element or structure element, and it even provides the correct data type. The problem is that with TYPE_ARRAY, it returns the start address of the array rather than the indexed element. With TYPE_USERDEF, it only returns the offset of the element instead of the actual address. This causes many issues with nested structures or arrays of structures, since it requires manually calculating the address based on the parent IBaseTreeNode. See attached image and example.
Last updated: 2025-08-28