Post by pernockham on Gateway in China - "Gateway not connected"
CODESYS Forge
talk
(Post)
Trying to communicate (from Europe) with/to a unit located in china, the communication seems blocked/stopped. The edge gateway is installed in a linux environment and was possible to link to my Automation server account using the "Automation service tool". However it seems the unit cannot communicate with the Automation server (a Network scan will give the message "Gateway not connected"). (I have tested the eq. setup with units locally which works.) Anyone having experience situation similar to this and if its possible to make this work? Will a VPN be needed possibly? Other tips?
Last updated: 2025-09-04
Post by pernockham on Gateway in China - "Gateway not connected"
CODESYS Forge
talk
(Post)
I think I understand my problem. They are most probably related to configuration of the network. When I use DHCP for the unit to my router it all works. However when using static IP I have not managed to reach functioning state. Trying to replicate the situation on my desk. Having a static IP on the "debian host" and a connection to my computer which then routes traffic on to internet. I have entered settings for gateway and netmask. I can ping from my "debian plc host" to internet and also do "curl google.com" so traffic seems to find its way through and back, still "Automation server" will not find the gateway. Any hints how a manual configuration should be done? Is it possibly a "firewall" issue of my "normal router"? Thanks for any help! Per
Last updated: 2026-01-27
Post by spoun on Problem with edge gateway config mode
CODESYS Forge
talk
(Post)
Hello, i want to connect my automation server and i follow the steps as desribed in the video series(https://www.youtube.com/watch?v=iiPKyyO4M00&list=PLaws15OZmd7Uu2W23zX2w424aI3TrOfHf) and also that guide (https://content.helpme-codesys.com/en/CODESYS%20Automation%20Server/_cas_add_plc_to_server.html). When i go to "Allow Edge Gateway configuration.." from the Codesys gateway Systray running i get the message in the attached picture, so i open the Gateway.cgf but the file doesn't contain an cmpedgegateway section as mentioned in the message. I have installed all the latest versions codesys and of the components mentioned in the guides. How can i solve that problem?
Last updated: 2024-10-21
Post by pernockham on Gateway in China - "Gateway not connected"
CODESYS Forge
talk
(Post)
Some new test. Now I cannot connect from Automation server to my gateway in any way also from my office setup with my unit directly connected to my router by dhcp. I can use the IDE and the tool "Connect Edge Gateway" and successfully connect to my server/link to my Automation server account. However no PLC will respond from Automation server "Network scan". I guess the traffic should be initiated by the gateway towards automation server? Any tips on how I can diagnose my problem? Ports to be opened etc? Thing is that this has been working previously but not now (base system has been updated from debian 12 to debian 13, but I dont know at which point it has stopped working). Setup as before. A "Codesys Control for Linux SL" running on a debian 13 installation. Any help/tips appreciated! Per Update. Found the error. Had a wrong gateway-setting. Which meant the PLC could not reach internet. Checked by "ping google.com" from the PLC.
Last updated: 2026-02-12
Post by martincapd on EWON
CODESYS Forge
talk
(Post)
I have the same problem in that I can connect to the eWon and ping the controller IP Address, however I cant connect through CodeSys. I'm using Gateway-1 which is configured to use "IP-Address: localhost" and "Port: 1217". Rather than scanning the network for devices, I enter the IP Address of the device, codesys returns a "No Device is repsonding..." message. See attached. I'm wondering if the IP-Address used Gateway-1 should be "localhost" or the WAN/LAN IP of the eWon? Thanks for the help MC
Last updated: 2024-02-21
Post by dileesha on Codesys device configuration
CODESYS Forge
talk
(Post)
I am new to this and I have a Beijer X2 Control 7 HMI and in my laptop I have installed codesys v3.5, ix developer and codesys gateway control. I have designed a simple PLC programme and Im trying to connect my PC and Beijer HMI via an ethernet cable and scanit in the codesys software. But when I scan it does not show any device.
Last updated: 2023-12-08
Post by transmin01 on CANbus issue
CODESYS Forge
talk
(Post)
Hi, I have been trying to get a CANbus device working with Codesys 3.5SP19 patch1 via a Beckhoff EL6751 gateway without success. I have the CANOpen_Manager and CANopen device configured but this will not run. Is there any code required to kickstart the CANbus comms into action? Regards Trevor
Last updated: 2023-09-13
Post by eschwellinger on RPI Zero w - Edge gateway cant install
CODESYS Forge
talk
(Post)
check 'uname -a' by ssh connection - addtional you'll probaly find the reason for not running with application by 'cat /var/opt/codesys/codesyscontrol.log' incase you are using 4.9.0.0 runtime version
Last updated: 2023-09-13
Post by danwoodlock on RPI Zero w - Edge gateway cant install
CODESYS Forge
talk
(Post)
Thanks very much for the explanation. I am basically new to the rpi world, but somewhat familiar with the indraworks/CtrlX versions of codesys. Appreciate your help.
Last updated: 2023-09-13
Post by eschwellinger on RPI Zero w - Edge gateway cant install
CODESYS Forge
talk
(Post)
ok now it is clear - this is a single core Pi Zero W. For this device there is no edge device available. But just for working with CODESYS it is not really needed and yes plc runs only for 2h unlicensed.
Last updated: 2023-09-13
Post by eschwellinger on Using the Wago 750-658 CAN Gateway
CODESYS Forge
talk
(Post)
I would ask the Wago Support - they have a CODESYS V3 runtime (not eCOCKPIT) which probably support this? At least worth to ask them.
Last updated: 2024-07-23
Post by fransh on WAGO PFC200 FW25 unable to connect
CODESYS Forge
talk
(Post)
Hi I set up my WAGO PFC200 controller and am unable to connect to the processor. Gateway is set to local host. I can connect to the unit with the WAGO Web Based management but not with Codesys V3.5 SP18.5. Any suggestion?
Last updated: 2023-12-09
Post by felipemsgarcia on Edge Gateway online, but PLC is not online
CODESYS Forge
talk
(Post)
Hello Edwin, I sent the info through CODESYS store my question, as I was afraid that I could be exposing sensitive information here in the forum. Thank you very much!
Last updated: 2024-01-10
Post by plumper on License problem gateway
CODESYS Forge
talk
(Post)
I have the same problem. Obtained new license without success. Codesys 3.5 SP 16, soft container. I would be grateful for quick help as we have to deliver equipment. Best regards
Last updated: 2024-04-16
Post by reinier-geers on License problem gateway
CODESYS Forge
talk
(Post)
By browser is not working. Tim suggestet to use Codesys and stick in the laptop. Thats working. But now with a stick with licence but no running motion.
Last updated: 2024-04-25
Post by winki on Error in licence activation
CODESYS Forge
talk
(Post)
Hello, Despite receiving an activation message after entering the license number, I don’t have any license installed on my gateway. I went to check in /var/opt/codesys/ and there is no License file. I searched the entire gateway for a .lic file and found no license. I’m really stuck—how can I fix this, please? When I am using the licence tools I got this picture: But nothing that have been activated. Loic,
Last updated: 2026-02-03
Post by winki on Error in licence activation
CODESYS Forge
talk
(Post)
Hello, Despite receiving an activation message after entering the license number, I don’t have any license installed on my gateway. I went to check in /var/opt/codesys/ and there is no License file. I searched the entire gateway for a .lic file and found no license. I’m really stuck—how can I fix this, please? When I am using the licence tools I got this picture: But nothing that have been activated. Loic,
Last updated: 2026-02-03
Post by danwoodlock on RPI Zero w - Edge gateway cant install
CODESYS Forge
talk
(Post)
Hello all, First post. I recently acquired an RPI zero W from amazon, and have been using it with Codesys v3.5 SP19 patch 2. I first got it working yesterday, and after installing the runtime on the Pi, I was prompted to install the edge gateway. Installation of the edge gateway failed because of unsupported architecture, undeterred I was able to connect to the pi and program as I wanted. The issue I've noticed is that if I do not load anything to the pi overnight, I can then no longer connect to the pi and download, although I can still ping it from my pc. I found that if I power cycle the PI, I am then able to connect again, and it works as normal. I did some googling and found instances where people recommended downloading the newest edge gateway, which brings me here. Wondering if there are any suggestions, or if this is a known issue. I actually tried installing all 3 versions of edge gateway for science, but all fail with the same message. Thanks -Dan
Last updated: 2023-09-13
Post by latassan on RaspberryPi 5 gateway problem
CODESYS Forge
talk
(Post)
Hello, I'm trying to use a raspberryPi 5 as a PLC. I fixed its IP address, I can ping it. I've also installed the CODESYS Control for Raspberry Pi 64 SL runtime on it. So I've created a gateway (IP address of the Raspberry, TCP port 1217). I see the green dot next to this gateway. When I do a network scan, I can see my raspberry (see photo). When I try to connect to it, I have to define an administrator profile, which I do. On validation, I see a message: No device is responding to the scan request. I've checked that port 1217 is listening on the raspberry, I've uninstalled the runtime then installed it again, but I can't connect. Also, when I try to configure the user groups before connecting, I see that Offline mode is not supported by the device, even though I'm connected to it in the Deploy Control SL tab. When I try to refresh, I see: Gateway not configured properly. How can I connect to my Raspberry? Have I defined my gateway incorrectly?
Last updated: 2025-06-12
Post by janber0206 on Gateway doesn't come online, regarding a working internet connection
CODESYS Forge
talk
(Post)
Solved EN: The Problem is that the Codesys Edge-Gateways have a License with a runtime of an half year, as long the Gateways are online they will self renew themselfs. In my Case the RevPi was more than a year offline and so the Edge-Gateway was not working anymore. The solution: I accessed a laptop that was directly connected to the RevPi. I installed the Codesys service tool and renewed the certificate manual. DE: Das Propblem ist das die Codesys Edge-Gatways eine Lizenz haben die nur ein halbes Jahr gültig ist. Solange das Gateway eine Internet verbindung hat aktualisiert sich das Zertifikat von alleine. In meinem Fall war das Gateway aber über ein Jahr offline und hat somit nicht mehr funktioniert. Die Lösung: Ich hab auf einen Laptop von Kunden mit TeamViewer zugegriffen, der Laptop wurde mit Kabel direkt mit RevPi verbunden. Codesys Service Tool installiert und dann das Gatewayzertifikat aktualisiert.
Last updated: 2023-10-26
Post by winki on Scan Network on gateway created with Control Sl
CODESYS Forge
talk
(Post)
Hello, I am new on CODESYS environement. I am used to BECKHOFF env. I would like to use codesys on debian distribution. I followed this tutorial : https://www.youtube.com/watch?v=TVF0LV279_4 But I am stuck on selected the device. I do not understand, everything is running correctly Someone have an idea ? Loic
Last updated: 2024-10-16
Post by eschwellinger on Scan Network on gateway created with Control Sl
CODESYS Forge
talk
(Post)
it seems that the device you scan, is not the same type which you have added to the project in CODESYS. Virtual Control is Arm 64 SL so please select this type in CODESYS when you generate a new Application..or right click to the device- update device - virtual Control Arm 64 SL
Last updated: 2024-10-16
Post by nulltrace on Modbus TCP Server connection is ESTABLISHED but all holding registers are value 0?
CODESYS Forge
talk
(Post)
your case looks different, the first one was an codesys modbus tcp-slave, your's an Master-Application with gateway. I dont know this Unit, but i would say, from Point of Codesys it looks wrong configured. Just give us more detailed configuration and the please make a sketch of the topology you're trying to realise.
Last updated: 2026-04-08
Post by jens on Using the Wago 750-658 CAN Gateway
CODESYS Forge
talk
(Post)
Is there any solution for this ? or do you need to use wago runtime and use the function blocks for the CanOpen ?
Last updated: 2024-07-23
Post by yannickasselin on ControlWin 3.5.20.30 Issues
CODESYS Forge
talk
(Post)
Hello, Trying to install ControlWin 3.5.20.30 on Windows 10 Enterprise 2016 LTSB and I always get this error about the gateway. 3.5.20.20 is working fine. Any ideas why? Thank you
Last updated: 2024-09-26
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.