Post by antonz on OSCAT Scale_r function not working in LD 4.60 works in LAD2 on 3.5.21sp3 CODESYS Forge talk (Post)
That's what I found as well Shaun. I have seen it at least in versions 3.5.21.1 and 3.5.21.3. There seems to be an issue with the FBD/LD package v4.6.0.0. The workaround proposed by Tim works but needs to be done manually on every code change/addition. For now we manually downgrade the FBD/LD package from v4.6.0.0 down to v4.5.0.0 after installation of CoDeSys. Same as you did. I hope this gets fixed on a next patch.
Last updated: 2025-11-21

Post by sunfloweeerrry on Edgelogix-rpi-1000-cm4102032 SPI port connection to PiFace I/O Driver in CodeSys. CODESYS Forge talk (Post)
Hello, I hv a problem. Couldn't solve this for 2 days now. So I'm quite new at CodeSys and I have to use the spi port x30 on the edgelogix rpi 1000. So what I have to do is just 'add device' at the SPI where I hv to pick the 'SPI master' after that I hv to change the parameters according to the edgelogix I did found in the spidev.h but nothing got updated so I 'add device' again where I pick the PiFace I/O Driver and I put my variables at the I/O Mapping, which i put the input startbit at the in part and led at the out part. I want to make the led blink according to my structured text code but somehow the hardware didn't connected with the CodeSys spi port. Nothing happens. Any idea what I have to do?
Last updated: 2023-08-18

Post by jegerjon on Find index based on values CODESYS Forge talk (Post)
Hi, I need to figure out witch indexes of an Array containing the highest and lowest values. Typically search for the 5 lowest values and result the indexnumbers containing the 5 lovest values. is there a library for this, or codeexample?
Last updated: 2023-08-20

Post by jegerjon on Find index based on values CODESYS Forge talk (Post)
Hi, I need to figure out witch indexes of an Array containing the highest and lowest values. Typically search for the 5 lowest values and result the indexnumbers containing the 5 lovest values. is there a library for this, or codeexample?
Last updated: 2023-08-20

Post by sven01 on Documentation / Usage Help For Scripting Engine Libraries CODESYS Forge talk (Post)
Hi, I am still not able to figure out how to use the the classes and their functions. πŸ˜” Let's say I would like to use the function "importfile()" from the class "ScriptTextListObject.ScriptTextListMarker". I would be grateful for an additional example. Thanks! 😊
Last updated: 2023-08-21

Post by kunz on Profinet Device keeps abort connection with AR alarm.ind(err) CODESYS Forge talk (Post)
Can somebody explain what the error Connection aborted: AR alarm.ind(err) exactly mean? I have the same Problem and dont know how to solve the issue
Last updated: 2023-08-21

Post by rossanoparis on After un upgrade of "CODESYS Control for Raspberry Pi MC SL" from v4.7 to v4.9 SysFileOpen function stopped working CODESYS Forge talk (Post)
Hello at all. After un upgrade of "CODESYS Control for Raspberry Pi MC SL" from v4.7 to v4.9 SysFileOpen function stopped working. I'm not able to read or write files from the PLC application. Before this upgrade all worked fine. I've read this thread [ https://forge.codesys.com/forge/talk/Engineering/thread/3da9ded84e/ ] Despite I followed that indications I couldn't get my code working again. Perhaps I'm missing something or I didn't understand how to use placeholders at all. Is there a different syntax to use for "SysFileOpen" in order to use placeholders? Thanks in advance for your help. Information Compiler: CODESYS V3.5 SP19 Patch 2 Runtime: codesyscontrol 4.9.0 HW: KUNBUS RevPi Connect S Below the paths I want to access (The entire CODESYSControl_User.cfg file is attached) [SysFile] PlaceholderFilePath.1=/home/pi/hpca/bin, $hpcabin$ PlaceholderFilePath.2=/home/pi/hpca/cfg, $hpcacfg$ PlaceholderFilePath.3=/home/pi/hpca/logs, $hpcalogs$ PlaceholderFilePath.4=/home/pi/hpca/resources, $hpcares$
Last updated: 2023-08-22

Post by janderson on OPC UA Server limitations, large array crashes runtime CODESYS Forge talk (Post)
when using an array of structs, the runtime crashes. but when using an array of LREALS, it'll do 100k at least
Last updated: 2023-08-23

Post by eschwellinger on Connection to device closed CODESYS Forge talk (Post)
is there a way to check the plclog on Opus A3 by using cmd line under Linux? This log is what you need to check for the disconnection problem
Last updated: 2023-08-24

Post by reinier-geers on Ping By Name CODESYS Forge talk (Post)
How can i ping my computer by name ? My controler uses SysSockPing , But seems only by IP adres, not by name. IP adres changes. So how can i ping by name or know that im connected
Last updated: 2023-08-24

Post by eschwellinger on How to configure CODESYSControl_User.cfg in order to use a specific network card for OPCUA Server CODESYS Forge talk (Post)
check this faq section here: https://faq.codesys.com/plugins/servlet/mobile?contentId=102137886#content/view/102137886
Last updated: 2023-08-25

Post by eschwellinger on How to configure CODESYSControl_User.cfg in order to use a specific network card for OPCUA Server CODESYS Forge talk (Post)
Hi Rossano, thank you for the feedback, you are right this need to be changed in the faq section. Regards Edwin
Last updated: 2023-08-28

Post by reinier-geers on Ping By Name CODESYS Forge talk (Post)
To bad. Controller uses Version 9.2 But i dont see a lower version of net bas Service. Maybe i can try a linux command.
Last updated: 2023-08-29

Post by eschwellinger on CSVReaderInit returns error : INVALID_HANDLE CODESYS Forge talk (Post)
this is a security issue not to read/write in the plc allowed path I would recommend to update and change the path in the application were the files are😏
Last updated: 2023-08-30

Post by roundex on CSVReaderInit returns error : INVALID_HANDLE CODESYS Forge talk (Post)
Could you please give me an example where to select new path in plc. Right now my csv files are placed into /home/user/csvfiles
Last updated: 2023-08-30

Post by totorovic on CSVReaderInit returns error : INVALID_HANDLE CODESYS Forge talk (Post)
Thank you for the return. The path targets to a CFast card. User has R/W access to it. We will try to change it.
Last updated: 2023-08-31

Post by felipemsgarcia on EtherCAT - Force Control Word CODESYS Forge talk (Post)
What worked for me: Use SMC_SetControllerMode and set the nControllerMode to SMC_nocontrol. With that, you can control the drive via Modes of Operation(16#6060) and Controlword(16#6040) directly. Hope that helps, Cheers!
Last updated: 2023-08-31

Post by marekxc on Error C0521 - unknow compiler CODESYS Forge talk (Post)
Select in tree "DEVICE", right-click and select "Update Device" Select "Library manager" and Change the version of the Library (down manualy). Samoetimes "Try reload Library". If you open a project version 3.5.19 in version 3.5.16, there are difficulties.
Last updated: 2023-09-02

Post by janderson on Ethercat scan for devices not picking up EL7041 as a softmotion axis CODESYS Forge talk (Post)
I have a beckhoff EL7041-1000 rev 21 in my ethercat bus but it wont correctly create a softmotion axis unless i manually insert the device. scan for devices gives me an el7041-1000 without an SM3 axis.
Last updated: 2023-09-02

Post by eschwellinger on Ethercat scan for devices not picking up EL7041 as a softmotion axis CODESYS Forge talk (Post)
Add existing version (with SM drive) - without scan - disable under expert settings in the slave the revision check.
Last updated: 2023-09-03

Post by automa on Defining local variables that can be independent with several users. CODESYS Forge talk (Post)
Hi, I am looking for a way to define a local variable that will be multi user independent. This is so several user can connect at the same time select frames independent of each other.
Last updated: 2023-09-04

Post by laazik2 on v3.5 SP19 - Modbus TCP Devices - Channel Limit? CODESYS Forge talk (Post)
I am actually wondering as well if there are plans to fix it or not? As adding two modbus devices creates it's own problems with connection limits and other issues, which some slave devices have.
Last updated: 2023-09-05

Post by richard-wang on When Keyboard Key is in Hold, then Webvisu is extreme slow and latent CODESYS Forge talk (Post)
Hi Tyro Did you resove your problem? I have the same issue. BR Richard
Last updated: 2023-09-05

Post by tvm on Web Client (HMI) Disconnects from Webvisu (Weidmuller u-OS) CODESYS Forge talk (Post)
We have seen this kind of thing before. I have two questions: 1. What kind of HMI are you using? 2. When this happens, are you able to connect using https, on port 8089?
Last updated: 2023-09-06

Post by ulvis on How to do horizontal scroll in CFC editor? CODESYS Forge talk (Post)
CFC (page oriented) editor does vertical scroll by mousewheel and zoom by ctrl + mousewheel, allright. How do I do the horizontal scroll (pan) using the mousewheel? (I do not want to drag the scrollbar, I am sure you have guessed by now.)