Search talk: -128到127是什么数据类型

 
<< < 1 .. 811 812 813 814 815 .. 888 > >> (Page 813 of 888)

Post by aniket-b on EtherCAT drive not moving CODESYS Forge talk (Post)
I have EtherCAT drive communicating properly without an error but when I use MC_JOG function, it is not moving at all, I can use MC_Power function and drive does respond to that but other functions are not working,. Please suggest what is wrong here.
Last updated: 2024-03-04

Post by aniket-b on "Distributed clocks are not synchronized, Rea time problem on hardware" ? CODESYS Forge talk (Post)
I am getting the same error. does anyone know how to troubleshoot this?
Last updated: 2024-03-04

Post by brell on Automatic xExecute NBS.TCP_write CODESYS Forge talk (Post)
I've recently started experimenting with CODESYS for a project and am fairly new to it. I'm currently working with Function Block Diagrams (FBD) to set up TCP communication between a server and a client, where the client is implemented as a Python script. Once the communication is established, my connection status changes to True, which is the expected behavior. My challenge arises with the TCP write module, which requires the xEnable_write flag to toggle between True and False. If xEnable_write remains True, the module only performs a single write operation. To address this, I introduced a falling edge trigger (F_TRIG), expecting it to help in toggling xEnable_write and it does, However, I've encountered an issue where in the beginning after connxion established I need to manually set xEnable_write to True for the system to work as intended. I'm looking for a way to automate this process so that xEnable_write becomes True automatically upon establishing a connection . Initially, I tried setting xEnable_write to True from the start, but this approach didn't work well since it left the flag permanently True, preventing further toggling. I also experimented with using a TON timer, but I faced similar issues. I am seeking a solution that automatically toggles xEnable_write between True and False after a connection is established, ensuring continuous write operations without manual intervention. Any advice or guidance on how to achieve this would be greatly appreciated."
Last updated: 2024-03-05

Post by timvh on when going online, stuck on "Syncing file "visuelemsdatetime.tl_datetime.txt" CODESYS Forge talk (Post)
I don't know the root cause... But what could help to continue when it seems to hang, is stop the CODESYS (communication) Gateway. Go to the Windows SysTray, find the icon for the Gateway and then stop it and start it again. This will interrupt the connection between CODESYS and your controller.
Last updated: 2024-03-05

Post by timvh on Automatic xExecute NBS.TCP_write CODESYS Forge talk (Post)
Use e.g. the condition: TCP_Connection_0.xActive AND NOT(TCP_Write_0.xDone)
Last updated: 2024-03-05

when going online, stuck on "Syncing file "visuelemsdatetime.tl_datetime.txt" CODESYS Forge talk (Thread)
when going online, stuck on "Syncing file "visuelemsdatetime.tl_datetime.txt"
Last updated: 2024-03-05

Automatic xExecute NBS.TCP_write CODESYS Forge talk (Thread)
Automatic xExecute NBS.TCP_write
Last updated: 2024-03-05

Post by timvh on IFM CR711S Version Mismatch CODESYS Forge talk (Post)
You should ask IFM to provide you with the correct version of their controller packages. Then after you have installed this, you can select the correct version of the controller by right clicking on it in the device tree, update device, enable the option "Display all versions" and then select the version which matches your controller. Alternatively you can ask IFM to provide an update package which can update the runtime version on your controller to 3.2.0.0.
Last updated: 2024-03-05

WAGO 750-8212 nad Sinamics v20 modbus RTU speed control CODESYS Forge talk (Thread)
WAGO 750-8212 nad Sinamics v20 modbus RTU speed control
Last updated: 2024-03-05

Post by john-robinson on Limiting Memory Access of an Array to Within its Bounds CODESYS Forge talk (Post)
Recently we had an issue regarding some simple code to calculate a rolling average. The code indexes from zero to 199 to properly store the current input into a circular buffer which then allows us to calculate a rolling average: VAR input_5s : REAL; outs_arr : ARRAY[0..199] OF REAL; i : USINT := 0; END_VAR ___ //this code runs every five seconds, calculating a rolling average outs_arr[i] := input_5s; i := i + 1; output := OSCAT_BASIC.ARRAY_AVG(ADR(outs_arr), SIZEOF(outs_arr)); IF i >= SIZEOF(outs_arr) THEN i := 0; END_IF There is a simple bug in this code where the index will be set to 0 when it has surpassed the length of the array in bytes (800 in this case) rather than larger than the number of reals in the array (200). The solution here is simple, replacing i >= SIZEOF(outs_arr) with i >= SIZEOF(outs_arr)/SIZEOF(outs_arr[0]). In this example when the index increased to 201 and the line outs_arr[201] := input_5s was called, codesys arbitrarily wrote to the address in memory that is where outs_arr[201] would be if the array was that long. I would like to find a way to wrap the codesys array inside of a wrapper class that checks if an input is within the bounds of an array before writing to that value. I know how I would implement that for a specific array, I could create a method or class that takes an input of an array of variable length, ie. ARRAY[*] OF REAL, but I don't know how to make this for any data type. I am wondering if anyone has ever done anything similar to this, or has any better suggestions to ensure that none of the programmers on this application accidentally create code that can arbitrarily write to other locations in memory.
Last updated: 2024-03-05

Post by tomast on WAGO 750-8212 nad Sinamics v20 modbus RTU speed control CODESYS Forge talk (Post)
Hi Guys, I am new to this forum and i would like to ask od anyone got communication with Siemens v20 vfd working via Modbus RTU? I followed many websites and finally got the communication working but have problema with read/write registers. For example if i try to read holding register 40011 which is accel time i get noth but when i set the offset 0x0000 en length 113 i get ale the registers. I cannot get speed control working. I read someth about stw (control Word) and hsw but have some problems to understand it en get it working. It would be really nice if someone could help me with it. Thx
Last updated: 2024-03-05

Post by mandeepahujaifm on IFM CR711S Version Mismatch CODESYS Forge talk (Post)
Please send an email to info.us@ifm.com and they shall provide you with the correct information. Alternatively you can check the website for latest packages. https://www.ifm.com/us/en/product/CR711S?tab=documents
Last updated: 2024-03-05

IFM CR711S Version Mismatch CODESYS Forge talk (Thread)
IFM CR711S Version Mismatch
Last updated: 2024-03-05

JSON Utilities - JSON file written with invalid structure CODESYS Forge talk (Thread)
JSON Utilities - JSON file written with invalid structure
Last updated: 2024-03-06

Web Browser special tools errors CODESYS Forge talk (Thread)
Web Browser special tools errors
Last updated: 2024-03-06

Post by mtho on JSON Utilities - JSON file written with invalid structure CODESYS Forge talk (Post)
I'm using the JSON Utilities SL library to write configurations in my program to a file. I'm generating the JSON data using the builder function block and all appears to work correctly. When I write the jsondata to file, I'm finding that some of the JSON elements are not being written in the right location in the file. Rather than writing they keys under the parent object, they get written outside the root JSON object at the end of the file. If I then try to read the file back into the program, I get an invalid_structure error. I don't get any errors when populating the JSON data or when writing the file. I attached an example of the JSON writer output. The problems begin with key P200. Each P200 should go under MBR1 through MBR3. Among the rest of the keys, they are supposed to be under different parent objects. I am using default values for wsLineBreak and encoding.
Last updated: 2024-03-06

Post by riccardo on Web Browser special tools errors CODESYS Forge talk (Post)
Nano goodmorning and thanks for the reaply, the links I have to manage are links as the following: https://192.168.1.101/u-os-app-codesys/application/visualization/webvisu.htm I saw that with Wikipedia or other web sites the tool works but not the link above. "google and some other providers, prevent from using as iframe and similar injections." The goal I'm pursuing is to display remote graphical user interfaces from a local graphical user interface over a local network. thanks in advance, Riccardo
Last updated: 2024-03-06

Post by timvh on Limiting Memory Access of an Array to Within its Bounds CODESYS Forge talk (Post)
Add the object "POU for Implicit Checks" to your application, then select "Bounds check". This will create a function which is automatically called each time an array is write accessed. In the function you can handle "out of bounds" situations. By default it will be limited to its lower or upper bound.
Last updated: 2024-03-06

Post by dkugler on Web Browser special tools errors CODESYS Forge talk (Post)
If there is a runtime + webvisu running at the .101 then the link should be: http://192.168.1.101:8080/webvisu.htm
Last updated: 2024-03-06

Post by john-robinson on Limiting Memory Access of an Array to Within its Bounds CODESYS Forge talk (Post)
Thanks Tim! This was exactly the functionality we were looking for. We are already using implicit checks to check for divide by 0 errors, we will add implicit checking for array bounds.
Last updated: 2024-03-06

Limiting Memory Access of an Array to Within its Bounds CODESYS Forge talk (Thread)
Limiting Memory Access of an Array to Within its Bounds
Last updated: 2024-03-06

Post by dhumphries on Not able to see input data coming from eip adapter on codesys CODESYS Forge talk (Post)
The green icon with an ! next to the device is concerning. Is the data type correct for the input, you are using a byte input but the description says string. Is there anything useful in the status tab?
Last updated: 2024-03-06

Post by sumit on Not able to see input data coming from eip adapter on codesys CODESYS Forge talk (Post)
Yes, green icon is there, this time I tried by enabling the device to always update variables but results are the same. I have attached the screenshot and eds file I am using.
Last updated: 2024-03-06

Post by rckalex on Data Source Limit CODESYS Forge talk (Post)
There appears to be a limit to the number of OPC Servers that can be connected simultaenously. 1-10 work but adding an 11th makes one of the previously linked ones unavailable. Is this a soft setting that can be adjusted? Using 3.5.18.30 on Win x64
Last updated: 2024-03-06

Post by rckalex on Data Source Error 418 CODESYS Forge talk (Post)
Trying to connect to a Codesys V3 datasource but am unsuccessful. The error information for the datasource reads: Failed (not nearer specified) Error ID: 418 Can anyone shed light on what that error means?
Last updated: 2024-03-06

<< < 1 .. 811 812 813 814 815 .. 888 > >> (Page 813 of 888)

Showing results of 22181

Sort by relevance or date