Post by rossanoparis on RevPi CONNECT+, CODESYS, EtherCAT master "Filedbus lost synchronicity"
CODESYS Forge
talk
(Post)
Hello @rmaas I assume, you've already verified and tuned everything regarding the EtherCAT network. In my case the problem was due to a wrong core assignement. I suggest to not use the core #0 for your EtherCAT task. The OS realtime patch, which is present on RevPi OS, uses the core #0 for its porpouses and it mustn't be used by any other task which requires realtime and deterministic features. regards Rossano
Last updated: 2024-04-11
Post by tk096 on Fieldbus has lost synchronicity
CODESYS Forge
talk
(Post)
Hi, a few suggestions on how to tackle the problem: - it might help to increase the cycle time of the ethercat task - increase the value of the ethercat parameter DCInSyncWindow (https://content.helpme-codesys.com/en/libs/IODrvEtherCATDriver/Current/pou-IoDrvEtherCAT/DCInSyncWindow.html) (see attached image) - enable FrameAtTaskStart (https://content.helpme-codesys.com/en/libs/IODrvEtherCATDriver/Current/pou-IoDrvEtherCAT/FrameAtTaskStart.html) in the ethercat master (see attached image) - if the drives can handle the synchronization problems, checking of the synchronization can be deactivated using SMC_Set_ETC_DCSyncSupervision (https://content.helpme-codesys.com/en/libs/SM3_Drive_ETC/Current/SMC_Set_ETC_DCSyncSupervision.html).
Last updated: 2024-04-11
RevPi CONNECT+, CODESYS, EtherCAT master "Filedbus lost synchronicity"
CODESYS Forge
talk
(Thread)
RevPi CONNECT+, CODESYS, EtherCAT master "Filedbus lost synchronicity"
Last updated: 2024-04-11
build (F11) / generate code using a python script file
CODESYS Forge
talk
(Thread)
build (F11) / generate code using a python script file
Last updated: 2024-04-11
Post by rmaas on RevPi CONNECT+, CODESYS, EtherCAT master "Filedbus lost synchronicity"
CODESYS Forge
talk
(Post)
Hi Rossano, Did you ever find a solution to this issue? It seems i am facing the same issue but i do not use OPCUA... Best Regards, Rinie Maas
Last updated: 2024-04-11
Post by eschwellinger on Problem mit control runtime V3 und profinet
CODESYS Forge
talk
(Post)
Hallo Tim, man hat halt einfach mit der Control Win - keine wirkliche harte Echzeit. Man müsste den Fehler genauer analysieren + ich denke er müsste den Slave wieder an den Busholen oder fällt ads ganze Netzwerk aus? Welche Versionen genau sind im Einsatz? Ist das halbwegs aktuell (PN 4.4.0.0?) Grüße Edwin
Last updated: 2024-04-11
Post by flavinhofh on Beaglebone Black OPC-UA Server
CODESYS Forge
talk
(Post)
ah ok, I will keep trying, I already removed all security from the Server side. I'm new on codesys and I don't know yet how to implement the certificates, but I will find out and also try. thanks for your reply.
Last updated: 2024-04-11
Post by tim-roelant on Problem mit control runtime V3 und profinet
CODESYS Forge
talk
(Post)
Hallo Edwin, meinst du das der control-win nicht wie SPS verwendet werden kann? Das program ist klein, und realtime brauch ich gar nicht, Es gibt im bus einem Turck inselstation mit 16 ein und ausgange, und ein MTS linearencoder, womit wir teile messen und abschneiden. Die cycluszeit reist auch nicht aus. Processorleisung bleibt unter 20%. Es geht mir darum das der profinet master in fehler geht, und nicht mehr seine telnehmer erkannen kann. Es kan passieren nach 10 minuten, aber auch nach 5 tage. Nur ein kaltstart bringt die bus wieder am laufen. (kein reconnect mochlich, auch die bus scannen functioniert nicht mehr) Wann ich aber ein ipscan durchfure mit Angryip auf der rechner sind alle telnehmer da. Ich habe noch eine andere application mit die gleiche anwendung, aber wo ein raspberry pi die SPS rolle spielt, und das functioniert einwandfrei. Soll ich fielleicht das OS von Rechenr nach linux umrusten? Der operator ist im moment sehr unzufrieden mit die "upgrade" von maschine... :-( lg Tim
Last updated: 2024-04-11
Post by tim-roelant on Problem mit control runtime V3 und profinet
CODESYS Forge
talk
(Post)
Hallo Edwin, meinst du das der control-win nicht wie SPS verwendet werden kann? Das program ist klein, und realtime brauch ich gar nicht, Es gibt im bus einem Turck inselstation mit 16 ein und ausgange, und ein MTS linearencoder, womit wir teile messen und abschneiden. Die cycluszeit reist auch nicht aus. Processorleisung bleibt unter 20%. Es geht mir darum das der profinet master in fehler geht, und nicht mehr seine telnehmer erkannen kann. Es kan passieren nach 10 minuten, aber auch nach 5 tage. Nur ein kaltstart bringt die bus wieder am laufen. (kein reconnect mochlich, auch die bus scannen functioniert nicht mehr) Wann ich aber ein ipscan durchfure mit Angryip auf der rechner sind alle telnehmer da. Ich habe noch eine andere application mit die gleiche anwendung, aber wo ein raspberry pi die SPS rolle spielt, und das functioniert einwandfrei. Soll ich fielleicht das OS von Rechenr nach linux umrusten? Der operator ist im moment sehr unzufrieden mit die "upgrade" von maschine... :-( lg Tim
Last updated: 2024-04-11
Post by reinier-geers on License problem gateway
CODESYS Forge
talk
(Post)
It doesnt see the dongel on my computer
Last updated: 2024-04-11
Post by thomaspfrimmer on Can't import enums OnlineChangeOption / ResetOption
CODESYS Forge
talk
(Post)
Hello Jusito, Can you share your final code, please ? I tried to implement a similar feature (going online, doing the reset and the start). But I get a timeout on the reset/start when I'm testing the script. If you got something working, I would appreciate to see it.
Last updated: 2024-04-11
Can't import enums OnlineChangeOption / ResetOption
CODESYS Forge
talk
(Thread)
Can't import enums OnlineChangeOption / ResetOption
Last updated: 2024-04-11
Post by tim-roelant on Problem mit control runtime V3 und profinet
CODESYS Forge
talk
(Post)
Wann ich ein scan mache bekomme ich keine teilnehmer, mit ein ipscan sind alle da. Die version von Ethernet & Profinet master ist 4.3.1 (oder muss ich besser codesys actualisieren nach letzten stand?
Last updated: 2024-04-11
Post by idir93dz on Identifier 'IoDrvGPIO' not defined
CODESYS Forge
talk
(Post)
Thanks a lot.
Last updated: 2024-04-11
Problem mit control runtime V3 und profinet
CODESYS Forge
talk
(Thread)
Problem mit control runtime V3 und profinet
Last updated: 2024-04-11
Identifier 'IoDrvGPIO' not defined
CODESYS Forge
talk
(Thread)
Identifier 'IoDrvGPIO' not defined
Last updated: 2024-04-11
Post by joschi2804 on Licensing info not available.
CODESYS Forge
talk
(Post)
Hello, I've added some additional log output. Maybe this helps in figuring out the root cause. I've turned logging and verbose mode on for the CodeMeterLin application and I get the error, that some entry is not found.
Last updated: 2024-04-11
Post by tim-roelant on Problem mit control runtime V3 und profinet
CODESYS Forge
talk
(Post)
Hallo Edwin, ich arbeite mit 3.5 SP 19.20 Runtime control win 3 X64 in anhang ein paar bilder von die zustand
Last updated: 2024-04-11
Post by r-niedermayer on Issue with WebVisu on Raspberry PI
CODESYS Forge
talk
(Post)
Regarding to your application: When clicking in the web visualization, the boolean variable will be tapped for both buttons. The LED in the web visualization lights up as long as the variable is true The used variables should come from the GVL, ad/or thePLC_Prg. We see no difference or problem in both projects: You have created a visuelement Push button a a tapper, that is supposed to control the variable in this way as expected. This is also reflected (switching Bool from false to true) in the program code, as well as in the (GVL declared) variables. Wherever the misunderstanding comes from: no, this is not memory or license related. Our best guess: it is probably more of an applicative/conceptual implementation.
Last updated: 2024-04-11
Issue with WebVisu on Raspberry PI
CODESYS Forge
talk
(Thread)
Issue with WebVisu on Raspberry PI
Last updated: 2024-04-11
Post by sachem on Problem retain values Weidmuller UC20-WL2000
CODESYS Forge
talk
(Post)
Show this, but I'm not sure what it means
Last updated: 2024-04-11
Post by mmpl on IIoT Library Payload Limit
CODESYS Forge
talk
(Post)
Last updated: 2024-04-11
SSD1206
CODESYS Forge
talk
(Thread)
SSD1206
Last updated: 2024-04-11
Problem retain values Weidmuller UC20-WL2000
CODESYS Forge
talk
(Thread)
Problem retain values Weidmuller UC20-WL2000
Last updated: 2024-04-11
Post by niallel on Continuous MC_PositionProfile
CODESYS Forge
talk
(Post)
Hi, Is it possible to have a MC_PositionProfile that runs continuously again and again without stopping the motor and starting again. I have a profile that contains about 50 steps that I want to repeat. At the end of each run the motor comes to a stop before the next one starts. My code checks for Done, then resets the Execute to False before setting Execute to True to run again, and I think this is causing the motor to go to standstill before starting again. There doesn't seem to be a BufferMode option like with MC_MoveAbsolute. Is it possible to do this? Many thanks,
Last updated: 2024-04-11
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.