Post by salvadegianluca on List files in a directory with SysDiropen And SysDirRead
CODESYS Forge
talk
(Post)
Good morning; I'm facing an issue that seems being caused by the library itself. I'm trying to create the list of all the files that are stored inside a psecific directory. Unluckily the first file is allways hidden. VAR CONSTANT arysEmptyArray:ARRAY[iArrayMinDimension..iArrayMAXDimension] OF STRING := [(iArrayMAXDimension - iArrayMinDimension)('')]; iArrayMinDimension:INT := 1; iArrayMAXDimension:INT := 99; END_VAR VAR_INPUT sDirectoryToInspect:STRING; sSearchFilter:STRING; END_VAR VAR_IN_OUT xCheckFileInsideDirectory:BOOL; END_VAR VAR arysListOfFoundFiles:ARRAY[iArrayMinDimension..iArrayMAXDimension] OF STRING; sNullString:STRING; iNullIndex:INT := 0; libInfoAboutThePath:DirInfo; libResultOfThePathMonitoring:CmpErrors.RTS_IEC_RESULT; libInstanceToMonitorThePath:CmpErrors.RTS_IEC_HANDLE; sEntityToSearch:STRING; dMaxEntityDimension:DINT := SIZEOF(sEntityToSearch); libFileInfo:DirInfo; sFilteredFileName:STRING; iIndexToScrollArrays:INT; END_VAR IF xCheckFileInsideDirectory THEN arysListOfFoundFiles:=arysEmptyArray; iIndexToScrollArrays:=iArrayMinDimension; libInstanceToMonitorThePath:= SysDirOpen(szDir:= sDirectoryToInspect,szDirEntry:=sNullString,diMaxDirEntry:= iNullIndex,pDirInfo:= ADR(libInfoAboutThePath),pResult:= ADR(libResultOfThePathMonitoring)); WHILE libResultOfThePathMonitoring = Errors.ERR_OK AND iIndexToScrollArrays <= iArrayMAXDimension DO sEntityToSearch:= ''; libResultOfThePathMonitoring:=SysDirRead(hDir:=libInstanceToMonitorThePath,szDirEntry:=sEntityToSearch,diMaxDirEntry:=dMaxEntityDimension,pDirInfo:=ADR(libFileInfo)); sFilteredFileName:= FUN_06_00_FindItemInString_0(sFilter:=sSearchFilter,sSource:=sEntityToSearch); IF sFilteredFileName <> '' THEN arysListOfFoundFiles[iIndexToScrollArrays]:=sFilteredFileName; iIndexToScrollArrays:=iIndexToScrollArrays + 1; END_IF IF libResultOfThePathMonitoring <> Errors.ERR_OK THEN libResultOfThePathMonitoring:= Errors.ERR_OK; END_IF END_WHILE libResultOfThePathMonitoring:=SysDirClose(hDir:= libInstanceToMonitorThePath); xCheckFileInsideDirectory:=FALSE; END_IF How is possible to solve this issue? Any known work around?
Last updated: 2024-09-17
Post by salvadegianluca on List files in a directory with SysDiropen And SysDirRead
CODESYS Forge
talk
(Post)
Good morning; I'm facing an issue that seems being caused by the library itself. I'm trying to create the list of all the files that are stored inside a psecific directory. Unluckily the first file is allways hidden. VAR CONSTANT arysEmptyArray:ARRAY[iArrayMinDimension..iArrayMAXDimension] OF STRING := [(iArrayMAXDimension - iArrayMinDimension)('')]; iArrayMinDimension:INT := 1; iArrayMAXDimension:INT := 99; END_VAR VAR_INPUT sDirectoryToInspect:STRING; sSearchFilter:STRING; END_VAR VAR_IN_OUT xCheckFileInsideDirectory:BOOL; END_VAR VAR arysListOfFoundFiles:ARRAY[iArrayMinDimension..iArrayMAXDimension] OF STRING; sNullString:STRING; iNullIndex:INT := 0; libInfoAboutThePath:DirInfo; libResultOfThePathMonitoring:CmpErrors.RTS_IEC_RESULT; libInstanceToMonitorThePath:CmpErrors.RTS_IEC_HANDLE; sEntityToSearch:STRING; dMaxEntityDimension:DINT := SIZEOF(sEntityToSearch); libFileInfo:DirInfo; sFilteredFileName:STRING; iIndexToScrollArrays:INT; END_VAR IF xCheckFileInsideDirectory THEN arysListOfFoundFiles:=arysEmptyArray; iIndexToScrollArrays:=iArrayMinDimension; libInstanceToMonitorThePath:= SysDirOpen(szDir:= sDirectoryToInspect,szDirEntry:=sNullString,diMaxDirEntry:= iNullIndex,pDirInfo:= ADR(libInfoAboutThePath),pResult:= ADR(libResultOfThePathMonitoring)); WHILE libResultOfThePathMonitoring = Errors.ERR_OK AND iIndexToScrollArrays <= iArrayMAXDimension DO sEntityToSearch:= ''; libResultOfThePathMonitoring:=SysDirRead(hDir:=libInstanceToMonitorThePath,szDirEntry:=sEntityToSearch,diMaxDirEntry:=dMaxEntityDimension,pDirInfo:=ADR(libFileInfo)); sFilteredFileName:= FUN_06_00_FindItemInString_0(sFilter:=sSearchFilter,sSource:=sEntityToSearch); IF sFilteredFileName <> '' THEN arysListOfFoundFiles[iIndexToScrollArrays]:=sFilteredFileName; iIndexToScrollArrays:=iIndexToScrollArrays + 1; END_IF IF libResultOfThePathMonitoring <> Errors.ERR_OK THEN libResultOfThePathMonitoring:= Errors.ERR_OK; END_IF END_WHILE libResultOfThePathMonitoring:=SysDirClose(hDir:= libInstanceToMonitorThePath); xCheckFileInsideDirectory:=FALSE; END_IF How is possible to solve this issue? Any known work around?
Last updated: 2024-09-17
Post by salvadegianluca on List files in a directory with SysDiropen And SysDirRead
CODESYS Forge
talk
(Post)
Good morning; I'm facing an issue that seems being caused by the library itself. I'm trying to create the list of all the files that are stored inside a psecific directory. Unluckily the first file is allways hidden. VAR CONSTANT arysEmptyArray:ARRAY[iArrayMinDimension..iArrayMAXDimension] OF STRING := [(iArrayMAXDimension - iArrayMinDimension)('')]; iArrayMinDimension:INT := 1; iArrayMAXDimension:INT := 99; END_VAR VAR_INPUT sDirectoryToInspect:STRING; sSearchFilter:STRING; END_VAR VAR_IN_OUT xCheckFileInsideDirectory:BOOL; END_VAR VAR arysListOfFoundFiles:ARRAY[iArrayMinDimension..iArrayMAXDimension] OF STRING; sNullString:STRING; iNullIndex:INT := 0; libInfoAboutThePath:DirInfo; libResultOfThePathMonitoring:CmpErrors.RTS_IEC_RESULT; libInstanceToMonitorThePath:CmpErrors.RTS_IEC_HANDLE; sEntityToSearch:STRING; dMaxEntityDimension:DINT := SIZEOF(sEntityToSearch); libFileInfo:DirInfo; sFilteredFileName:STRING; iIndexToScrollArrays:INT; END_VAR IF xCheckFileInsideDirectory THEN arysListOfFoundFiles:=arysEmptyArray; iIndexToScrollArrays:=iArrayMinDimension; libInstanceToMonitorThePath:= SysDirOpen(szDir:= sDirectoryToInspect,szDirEntry:=sNullString,diMaxDirEntry:= iNullIndex,pDirInfo:= ADR(libInfoAboutThePath),pResult:= ADR(libResultOfThePathMonitoring)); WHILE libResultOfThePathMonitoring = Errors.ERR_OK AND iIndexToScrollArrays <= iArrayMAXDimension DO sEntityToSearch:= ''; libResultOfThePathMonitoring:=SysDirRead(hDir:=libInstanceToMonitorThePath,szDirEntry:=sEntityToSearch,diMaxDirEntry:=dMaxEntityDimension,pDirInfo:=ADR(libFileInfo)); sFilteredFileName:= FUN_06_00_FindItemInString_0(sFilter:=sSearchFilter,sSource:=sEntityToSearch); IF sFilteredFileName <> '' THEN arysListOfFoundFiles[iIndexToScrollArrays]:=sFilteredFileName; iIndexToScrollArrays:=iIndexToScrollArrays + 1; END_IF IF libResultOfThePathMonitoring <> Errors.ERR_OK THEN libResultOfThePathMonitoring:= Errors.ERR_OK; END_IF END_WHILE libResultOfThePathMonitoring:=SysDirClose(hDir:= libInstanceToMonitorThePath); xCheckFileInsideDirectory:=FALSE; END_IF How is possible to solve this issue? Any known work around?
Last updated: 2024-09-17
Post by lbartik on J1939 TX/RX PDU1
CODESYS Forge
talk
(Post)
Is it possible to transmit a PDU1 PGN using the J1939 manager and local device? What if I need to transmit a PGN RQST via 0xEA00 (PGN 59904)? How would I do this P2P (Destination < 0xFF) or broadcast (Destination 0xFF)? I don't think this is possible for any destination type. I don't think it's possible to receive broadcast PDU1 messages either. For example, an address claim PGN 60928 (0x18EEFF80) is addressed to all nodes (0xFF) and not any specific local device so it will be filtered out. These are major oversights in the IoDrvJ1939 library to not support every PDU1 RX/TX scenario. IoDrvJ1939 supported scenario: 1. Receive (RX) PDU1 (P2P) destination-specific (PDU-specific < 255) to local device with matching address IoDrvJ1939 unsupported scenarios: 1. Receive (RX) PDU1 (P2P) global (PDU-specific = 255) 2. Transmit (TX) PDU1 (P2P) global (PDU-specific = 255) 3. Transmit (TX) PDU1 (P2P) destination-specific (PDU-specific < 255)
Last updated: 2024-09-23
Post by naps on cant install runetime on 750-8202
CODESYS Forge
talk
(Post)
Hello, im trying to install the 3.5 Runtime on a a fresh image on my 750-8202. Product Description: WAGO 750-8202 PFC200 CS 2ETH RS Firmware Revision: 03.10.08(22) ~~~ df -h Filesystem Size Used Available Use% Mounted on ubi0:rootfs.1 82.5M 66.5M 11.8M 85% / devtmpfs 117.8M 16.0K 117.8M 0% /dev none 118.3M 12.0K 118.3M 0% /tmp none 118.3M 0 118.3M 0% /media none 4.0M 136.0K 3.9M 3% /var/log none 118.3M 112.0K 118.2M 0% /var/run none 118.3M 0 118.3M 0% /var/lock none 118.3M 0 118.3M 0% /var/tmp none 118.3M 0 118.3M 0% /sys/fs/cgroup tmpfs 118.3M 48.0K 118.2M 0% /run /dev/ubi0_1 58.6M 3.4M 52.2M 6% /home /dev/ubi0_1 58.6M 3.4M 52.2M 6% /settings /dev/ubi0_1 58.6M 3.4M 52.2M 6% /log ~ After installation and reboot i have still the wago webinterface. No runtime on Information Tab and the Runtime button from the configuration tab is lost. iv try it with firmware 22 and 21. Same problem. What can i do?
Last updated: 2024-09-29
Post by bjarne-pagaard on Communication between applications on same device/controller/runtime (Win RTE 3.5.20.20)
CODESYS Forge
talk
(Post)
Thanks for this - I have now been looking in to just having an extra (non-RTE) runtime on the same machine, as you suggest. I will probably proceed this way. Even though it still seems very odd to me, that variable exchange to a different runtime is easier than between applications on the same controller. There will be some fun with the licensing, it seems. Does anyone know if it is possible to specify which license container/specific license the runtime is going to use at runtime. Let's say I have two available licenses with different resources available, for example one license allows multicore and multiple EtherCAT channels, but not many visu tags (for the RTE). Another with less resources but a lot of visu tags (for the Visu controller). Let's say the program in one of the controllers could be fully licensed by either of the two available licenses, but picks the 'largest' first. A bit later, the larger application starts, but is left with the smaller license.. How can I make sure that the 2 runtimes select the right license at startup?
Last updated: 2024-10-01
Post by codesysbeginner on Eaton XC303 - USB Mounting / Trend manager
CODESYS Forge
talk
(Post)
Hi, For a project I am using the trendmanager functionality, I changed the placeholder filepath to which the SQL database is saved to: home/disk_usb, $trend$. Which only works as long as the usb was mounted to the PLC at boot. However, I'd like to be able to switch the USB's out if they break or for data analysis. However when a new (or the same) USB is plugged back in the shortcut doens't exist on the device anymore. Also in the device directory under root/mnt/ a new folder appears SDB1 in addition to SDA1 to which the Trendmanager was originally writing. The SDA1 folder is empty/unreachable while the new SDB1 folder has the contents of the USB drive. I tried disabling the trendmanger while unplugging the USB's however this doesn't work. My question, how do I make it so that when I plug a USB drive back in, it will be mounted to SDA1 instead of SDB1? Kind Regards
Last updated: 2024-10-09
Post by etienneneu on Trend x-axis description incorrect display
CODESYS Forge
talk
(Post)
Hello everyone, maybe someone can help me with the following problem. I wanted to insert a trend element in my visualization. The problem is that I have set fixed fonts with a scaling of 1.5 for the individual languages via the visualization manager. This setting means that I have this scaling in every element, which has been quite comfortable so far because I didn't have to set the individual properties in the text fields. But in the trend element, even if I select other font sizes or fonts in the element itself, this font is also overwritten and I get a label on the x-axis that is no longer displayed correctly. Is there a way to prevent the overwriting of the font properties in this element or similar behavior? I mean, I could change the font size of each element manually, but the Visu app is a bit larger and it would be easier to have another option. Best regards Etienne
Last updated: 2024-11-28
Post by mubeta on Strange problem with the ‘MC_SetPosition’ function
CODESYS Forge
talk
(Post)
Hi gseidel, before moving to HW implementation, I had created the same program in simulation mode with virtual drives and, as far as I remember, everything worked fine simulating process and the few useful inputs. So it does not seem to be a SoftMotion library problem, but rather a problem with dynamics or physical axis adjustments. What escapes me, however, is the fact that this function is supposed to perform a position shift virtually, in fact without interfering with the axis itself, thus independent of its adjustments. MC_SetPosition() is not a homing function, in fact it is clearly intended to be executed on the fly with the axis moving. Now I'll see if I can reduce the program, although I don't like it very much. In my life I have learned that problem searches should be done on the part, and not in a more or less similar way.
Last updated: 2025-01-10
Post by timvh on STRING conversions to DWORD
CODESYS Forge
talk
(Post)
I guess that the printer expects to receive an array of byte values. So where it is described that it expects to receive: Hercules String : 1B4F513030311B7532626C61636B04 it actually expects to receive an array of bytes with the values 1B,4F,51,30,30, etc. So what you can do is create an array of bytes and assign the byte value to each item in the array: VAR abyToSend : ARRAY[0..99] OF BYTE; END_VAR abyToSend[0] := 16#1B; // ASCII Escape character, hexadecimal representation uses 16# as prefix abyToSend[1] := 16#4F; // ASCII 'O' abyToSend[2] := 16#51; // ASCII 'Q' abyToSend[3] := 16#30; // ASCII '0' // you can do the rest yourself // maybe could be created a lot smarter, but gives you an indication how to handle this. Then with the serial communication (or TCP/IP?) you can send a message with the reference to the array (abyToSend) and the number of bytes to send (15 bytes for the string you gave as example).
Last updated: 2025-02-02
Post by timvh on Device diagnosis ( EtherCAT IO card )
CODESYS Forge
talk
(Post)
You can get the state by just using the name of your node (same name as in device tree): VAR etcState: IoDrvEthercatDriverLib.ETC_SLAVE_STATE; END_VAR etcState := EJ1100.wState; Alternatively, you can iterate through the device tree to get the status of all (Ethercat) nodes. See here an example (no guarantee it works, just give as suggestion): PROGRAM P_IO_State VAR CONSTANT uiMAX_NR_OF_TERMINALS : UINT := 100; END_VAR VAR // general device diagnosis // can only be used when the Device - PLC Settings - Advanced settings - enable diagnosis for devices is enabled // this will add the DED library coupler: DED.INode; terminal: DED.INode; aDeviceState: ARRAY[0..uiMAX_NR_OF_TERMINALS - 1] OF DED.DEVICE_STATE; uiTerminalCount : UINT; uiIndex : UINT; // for each terminal check if it implements device diagnostics xQueryResult: BOOL; itfDevice : DED.IDevice2; xDiagAvailable: BOOL; eError: DED.ERROR; xEverythingOK: BOOL; END_VAR uiTerminalCount := 0; // start at the top of the device tree with the first EtherCAT coupler coupler := EtherCAT_Master.FirstChildNode; WHILE coupler <> 0 DO // for each coupler that is found start at the first terminal terminal := coupler.FirstChildNode; WHILE terminal <> 0 AND uiTerminalCount < uiMAX_NR_OF_TERMINALS - 1 DO // for each terminal that is found get the status through the device diagnosis interface xQueryResult := __QUERYINTERFACE(terminal, itfDevice); IF xQueryResult THEN aDeviceState[uiTerminalCount] := itfDevice.GetDeviceState(xDiagnosisInfoAvailable => xDiagAvailable, eError => eError); uiTerminalCount := uiTerminalCount + 1; END_IF terminal := terminal.NextSiblingNode; END_WHILE coupler := coupler.NextSiblingNode; END_WHILE uiIndex := 0; xEverythingOK := TRUE; WHILE uiIndex < uiTerminalCount DO IF aDeviceState[uiIndex] <> DED.DEVICE_STATE.RUNNING THEN xEverythingOK := FALSE; EXIT; END_IF uiIndex := uiIndex + 1; END_WHILE
Last updated: 2025-02-06
Post by carl25 on Confused about stepper spec & tips on pwm-step/dir
CODESYS Forge
talk
(Post)
Hello! I have asked the few I know who have knowledge of this and now turn to this one inexhaustible source of knowledge aka. the electronics forum. I was going to buy stepper motors yesterday but got so confused about the spec that I need to get an answer to this first. 2 different stepper motors, quite close in size but with very different spec. https://www.oyostepper.de/goods-40-Nema-17-Schrittmotor-Bipolar-12V-18-Grad-40Ncm-04A-12-Volt-4-Dr%C3%A4hte-Hybrid-Schrittmotor.html https://www.oyostepper.de/goods-38-Nema-17-Schrittmotor-Bipolar-18-deg-22Ncm-133A-28V-4-Dr%C3%A4hte-Hybrid-Schrittmotor.html Both Nema17 but the first 1.33A and 22Ncm and the second only 0.4A but almost double the torque. I can see that the resistance is very much higher on the latter but what's the catch? Double the torque to 1/3 the current sounds a little too good to be true so what am I missing?
Last updated: 2025-02-21
Post by pernockham on Inheritence of struct,
CODESYS Forge
talk
(Post)
Im looking for a way to define predefined version of the same structures through "extends"/inheritance. What I want to do is best shown with an example: TYPE log_item_val_type : ( BOOL_ := 0, INT_, REAL_, STRING_ ); END_TYPE TYPE LOG_DATA_BASE STRUCT val_type : log_item_val_type; (* value, name etc *) ENDSTRUCT ENDTYPE (* this/below is not possible as I understand from the compiler?? *) TYPE LOG_DATA_BOOL extends LOG_DATA_BASE : STRUCT val_type : log_item_val_type := log_item_val_type.BOOL_; END_STRUCT END_TYPE TYPE LOG_DATA_INT extends LOG_DATA_BASE : STRUCT val_type : log_item_val_type := log_item_val_type.INT_; END_STRUCT END_TYPE etc. for LOG_DATA_REAL and ..STRING. The system will not allow me to "re-define" "val_type" however. Instead I must do the work-around of defining four different types with all fields individually defined. The benefit if I could extend the base item would be that Im (more) sure the structures are identical. In usage I can call in a specific type rather use the base type and assign which type. Usage by pointer/ref to log_data_base would also be easier.. (* Usage: *) log_data : log_data_int := (name, value etc.) (* Instead of: *) log_data : log_data_base := (name, value, val_type).. Is this possible to achieve in some way that I have missed?
Last updated: 2025-03-05
Post by imdatatas on Auto Declare window disappears by itself in the Ladder editor
CODESYS Forge
talk
(Post)
Hello Everyone, The "Auto Declare" window disappears by itself in the Ladder editor. For example, a new function block is wanted to be added to the Ladder editor. (For example; MC_Jog block and instance name will be fbMcJog). To do this, "Empty box with EN/ENO" is added to the ladder line from the Toolbox on the right and when you type MC_Jog in the empty box and press enter, normally the "Auto Declare" window appears and you are expected to be asked to write the instance name here. However, this "Auto Declare" window closes itself immediately, it does not wait for the user to enter a value or close the window. I often encounter this situation in many IDE versions. Does this seem like a bug? If anyone has encountered a similar problem while creating a new program name, function or function block instance name regarding the "Auto Declare" window and knows a solution, I would be glad if you could share it. Best wishes Imdat
Last updated: 2025-03-06
Post by ojz0r on Assignment Efficiency - Repetitive Assignment vs IF statement
CODESYS Forge
talk
(Post)
Its important that you know the difference between the two. Example 1: Coils[0] := Coils[0] OR (Buttons[0] AND Sensors[0] > 6); In this case the statements will be evaluated every scan and result in either true or false for Coils[0]. Example 2: IF NOT Coils[0] AND Buttons[0] AND (Sensors[0] > 6) THEN Coils[0] := TRUE; END_IF In this example Coils[0] will latch the result in a true evaluation, if you want it to behave the same way as example 1 then you need to do it like example 3 below: IF NOT Coils[0] AND Buttons[0] AND (Sensors[0] > 6) THEN Coils[0] := TRUE; ELSE Coils[0] := FALSE; END_IF However back to the real question. There is no problem using either example 1 or example 3, if im not requiring a latch i usually go with example 1 as it is more compact.
Last updated: 2025-03-07
Post by pikebuster on Help for a newbie
CODESYS Forge
talk
(Post)
Can somebody help me with this? I have problem with the button! This task must be solved using Sequential Function Chart (SFC), IEC 61131-3. TASK Create an SFC program to control a traffic light at an intersection. Description: You will program a traffic light that has three phases: Green, Yellow, and Red. The traffic light must follow these rules: Green light is on for 10 seconds. Yellow light is on for 3 seconds. Red light is on for 10 seconds. If the pedestrian button is pressed, the system must keep the red light on for 20 seconds during the next cycle. After the pedestrian has “crossed,” the system should return to its normal cycle. Basic Steps: Initialization: Start by setting the traffic light to Red. Green Phase: After 10 seconds, switch to Green. Yellow Phase: After 10 seconds in the Green phase, switch to Yellow. Red Phase: After 3 seconds in the Yellow phase, switch back to Red. Loop: Repeat the cycle. Use, for example, lamp symbols in the visualization module to simulate the traffic light. You may also add a simple pedestrian light if desired.
Last updated: 2025-03-11
Post by egau on Enable and Disable Project IO programmatically
CODESYS Forge
talk
(Post)
Hi @eschwellinger, I tried this with Modbus COM slaves. I was able to disable them (slave becomes greyed out in the device tree), but the DED.Reconfigure "eError" output shows "NOT_SUPPORTED". After this, when I tried to re-enable the slave, it did not work (device stayed greyed out in the device tree), and the DED.Reconfigure "eError" output also showed "NOT_SUPPORTED". Is there something to do about this, or the device just doesn't support reconfiguration? P.S: I tried this running locally on my computer (not in simulation mode). So of course I was not physically connected to the devices. I have two similar projects, but one of them doesn't have the Modbus_COM devices. I know I can "Exclude from build" the devices for that project, but I would really prefer not to do this if possible. I would prefer to dynamically toggle a configuration variable that would enable or disable the slaves.
Last updated: 2025-03-14
Post by nz-dave on MC_HOMING
CODESYS Forge
talk
(Post)
Hi Just new to motion and i am building my own 3axis cnc cutter using servo drives. i have every thing working quite well apart from mc_home. when executed (r_trig) it stops immediately and i get fb_wasnt_called_during_motion. if i execute the mc_home fb with a toggle it just runs and runs for a while then errors out. what im unsure of is the way mc_home works. from what i understand it changes the drive mode to 6 (homing) and should then run of the drive homing settings. once origin sensor is made then homing would stop and mc_home.done is true. and the position on the fb is where i what the new home position (zero) to be? or do i feed mc_readposition to that input? so i would think its the settings in the drive that aren't quite right. but i believe they are all correct. has any one got any info to steer me in the right direction? Cheers
Last updated: 8 hours ago
Post by francesco86 on Script python for write in a file Project information
CODESYS Forge
talk
(Post)
Dear all, My python script can read a Codesys project and save in file the different POU, but the problem is that I don't able to read the project info from the obj list. Following of this message there is my python script. Can you help my? Best regards Francesco # encoding:utf-8 # We enable the new python 3 print syntax from __future__ import print_function import os import shutil import time import sys from datetime import datetime print("--- Saving files in the project: ---") print("sys.argv: ", len(sys.argv), " elements:") for arg in sys.argv: print(" - ", arg) if (len(sys.argv)>1): folderExportName = sys.argv[1] print(" folderExportName: ", folderExportName) exportPath = sys.argv[2]+ sys.argv[3]+ "\\"+ sys.argv[1] print(" File path: ", exportPath) # git has_repo=False #save_folder=r'E:\Tmp\ControlPlugins\ControlPlugins\Export' save_folder = exportPath if not os.path.exists(save_folder): os.makedirs(save_folder) else: a=os.listdir(save_folder) for f in a: if not f.startswith("."): sub_path= os.path.join(save_folder,f) if os.path.isdir(sub_path): shutil.rmtree(sub_path) else: os.remove(sub_path) elif f==".git": has_repo=True info={} type_dist={ '792f2eb6-721e-4e64-ba20-bc98351056db':'pm', #property method '2db5746d-d284-4425-9f7f-2663a34b0ebc':'dut', #dut 'adb5cb65-8e1d-4a00-b70a-375ea27582f3':'lib', #lib manager 'f89f7675-27f1-46b3-8abb-b7da8e774ffd':'m', #method no ret '8ac092e5-3128-4e26-9e7e-11016c6684f2':'act', #action '6f9dac99-8de1-4efc-8465-68ac443b7d08':'pou', #pou '6654496c-404d-479a-aad2-8551054e5f1e':'itf', #interface '738bea1e-99bb-4f04-90bb-a7a567e74e3a':'', #folder 'ffbfa93a-b94d-45fc-a329-229860183b1d':'gvl', #global var '5a3b8626-d3e9-4f37-98b5-66420063d91e':'prop', #property '2bef0454-1bd3-412a-ac2c-af0f31dbc40f':'tl', #textlist '63784cbb-9ba0-45e6-9d69-babf3f040511':'gtl', #global textlist '225bfe47-7336-4dbc-9419-4105a7c831fa':'dev', #device 'ae1de277-a207-4a28-9efb-456c06bd52f3':'tc', #task configuration 'f8a58466-d7f6-439f-bbb8-d4600e41d099':'m', #method with ret '261bd6e6-249c-4232-bb6f-84c2fbeef430':'gvl', #gvl_Persistent '98a2708a-9b18-4f31-82ed-a1465b24fa2d':'task', #task '085afe48-c5d8-4ea5-ab0d-b35701fa6009':'progInfo'#project information }; def save(text,path,name,tp): if not tp: tp='' else: tp='.'+tp+'.txt' with open(os.path.join(path,name+tp),'w') as f: f.write(text.encode('utf-8')) def print_tree(treeobj, depth, path): global info #record current Path curpath=path isfolder=False t='' #text tp='' #type # get object name name = treeobj.get_name(False) id = treeobj.type.ToString() if id in type_dist: tp = type_dist[treeobj.type.ToString()] #Print all type of objects #print("--Name: ", tp) else: info[id]=name if treeobj.is_device: deviceid = treeobj.get_device_identification() t = 'type='+str(deviceid.type) +'\nid=' +str(deviceid.id) + '\nver='+ str(deviceid.version) if tp == "progInfo": print("-- There is prog info, ", tp) print("-- It has textual declaration: , ", treeobj.has_textual_declaration) print("-- It has textual implementation: , ", treeobj.has_textual_implementation) print("-- It is folder: , ", treeobj.is_folder) print("-- It is children: , ", treeobj.get_children(False)) print("-- It is children len: , ", len(treeobj.get_children(False))) print("-- It is progInfo type: , ", type(treeobj.ScriptProject)) #for child in treeobj.get_children(False): # print_tree(child, depth+1,curpath) try: if treeobj.is_folder : #system.ui.prompt('folder:'+u, PromptChoice.YesNo, PromptResult.Yes) isfolder=true pass except: pass if treeobj.has_textual_declaration : t=t+'(*#-#-#-#-#-#-#-#-#-#---Declaration---#-#-#-#-#-#-#-#-#-#-#-#-#*)\r\n' a=treeobj.textual_declaration t=t+a.text if treeobj.has_textual_implementation: t=t+'(*#-#-#-#-#-#-#-#-#-#---Implementation---#-#-#-#-#-#-#-#-#-#-#-#-#*)\r\n' a=treeobj.textual_implementation t=t+a.text if treeobj.has_textual_declaration and not treeobj.has_textual_implementation: t=t+'(*#-#-#-#-#-#-#-#-#-#---NOT Implementation visible---#-#-#-#-#-#-#-#-#-#-#-#-#*)\r\n' if treeobj.is_task : exports=[treeobj] projects.primary.export_native(exports,os.path.join(curpath,name+'.task')) if treeobj.is_libman: exports=[treeobj] projects.primary.export_native(exports,os.path.join(curpath,name+'.lib')) if treeobj.is_textlist: treeobj.export(os.path.join(curpath,name+'.tl')) children = treeobj.get_children(False) if children or isfolder: if tp: curpath=os.path.join(curpath,name+'.'+tp) else: curpath=os.path.join(curpath,name) if not os.path.exists(curpath): os.makedirs(curpath) if t: save(t,curpath,name,tp) for child in treeobj.get_children(False): print_tree(child, depth+1,curpath) for obj in projects.primary.get_children(): print_tree(obj,0,save_folder) with open(os.path.join(save_folder,'ExportInfo.txt'),'w') as f: now = datetime.now() infTimeExecution = now.strftime("%Y-%m-%d %H:%M:%S") f.write("Export date and time: "+infTimeExecution + "\r\n" + str(info)) print("--- Script finished. ---") #system.ui.info('save ok') projects.primary.close()
Last updated: 2024-04-30
Post by francesco86 on Script python for write in a file Project information
CODESYS Forge
talk
(Post)
Dear all, My python script can read a Codesys project and save in file the different POU, but the problem is that I don't able to read the project info from the obj list. Following of this message there is my python script. Can you help my? Best regards Francesco # encoding:utf-8 # We enable the new python 3 print syntax from __future__ import print_function import os import shutil import time import sys from datetime import datetime print("--- Saving files in the project: ---") print("sys.argv: ", len(sys.argv), " elements:") for arg in sys.argv: print(" - ", arg) if (len(sys.argv)>1): folderExportName = sys.argv[1] print(" folderExportName: ", folderExportName) exportPath = sys.argv[2]+ sys.argv[3]+ "\\"+ sys.argv[1] print(" File path: ", exportPath) # git has_repo=False #save_folder=r'E:\Tmp\ControlPlugins\ControlPlugins\Export' save_folder = exportPath if not os.path.exists(save_folder): os.makedirs(save_folder) else: a=os.listdir(save_folder) for f in a: if not f.startswith("."): sub_path= os.path.join(save_folder,f) if os.path.isdir(sub_path): shutil.rmtree(sub_path) else: os.remove(sub_path) elif f==".git": has_repo=True info={} type_dist={ '792f2eb6-721e-4e64-ba20-bc98351056db':'pm', #property method '2db5746d-d284-4425-9f7f-2663a34b0ebc':'dut', #dut 'adb5cb65-8e1d-4a00-b70a-375ea27582f3':'lib', #lib manager 'f89f7675-27f1-46b3-8abb-b7da8e774ffd':'m', #method no ret '8ac092e5-3128-4e26-9e7e-11016c6684f2':'act', #action '6f9dac99-8de1-4efc-8465-68ac443b7d08':'pou', #pou '6654496c-404d-479a-aad2-8551054e5f1e':'itf', #interface '738bea1e-99bb-4f04-90bb-a7a567e74e3a':'', #folder 'ffbfa93a-b94d-45fc-a329-229860183b1d':'gvl', #global var '5a3b8626-d3e9-4f37-98b5-66420063d91e':'prop', #property '2bef0454-1bd3-412a-ac2c-af0f31dbc40f':'tl', #textlist '63784cbb-9ba0-45e6-9d69-babf3f040511':'gtl', #global textlist '225bfe47-7336-4dbc-9419-4105a7c831fa':'dev', #device 'ae1de277-a207-4a28-9efb-456c06bd52f3':'tc', #task configuration 'f8a58466-d7f6-439f-bbb8-d4600e41d099':'m', #method with ret '261bd6e6-249c-4232-bb6f-84c2fbeef430':'gvl', #gvl_Persistent '98a2708a-9b18-4f31-82ed-a1465b24fa2d':'task', #task '085afe48-c5d8-4ea5-ab0d-b35701fa6009':'progInfo'#project information }; def save(text,path,name,tp): if not tp: tp='' else: tp='.'+tp+'.txt' with open(os.path.join(path,name+tp),'w') as f: f.write(text.encode('utf-8')) def print_tree(treeobj, depth, path): global info #record current Path curpath=path isfolder=False t='' #text tp='' #type # get object name name = treeobj.get_name(False) id = treeobj.type.ToString() if id in type_dist: tp = type_dist[treeobj.type.ToString()] #Print all type of objects #print("--Name: ", tp) else: info[id]=name if treeobj.is_device: deviceid = treeobj.get_device_identification() t = 'type='+str(deviceid.type) +'\nid=' +str(deviceid.id) + '\nver='+ str(deviceid.version) if tp == "progInfo": print("-- There is prog info, ", tp) print("-- It has textual declaration: , ", treeobj.has_textual_declaration) print("-- It has textual implementation: , ", treeobj.has_textual_implementation) print("-- It is folder: , ", treeobj.is_folder) print("-- It is children: , ", treeobj.get_children(False)) print("-- It is children len: , ", len(treeobj.get_children(False))) print("-- It is progInfo type: , ", type(treeobj.ScriptProject)) #for child in treeobj.get_children(False): # print_tree(child, depth+1,curpath) try: if treeobj.is_folder : #system.ui.prompt('folder:'+u, PromptChoice.YesNo, PromptResult.Yes) isfolder=true pass except: pass if treeobj.has_textual_declaration : t=t+'(*#-#-#-#-#-#-#-#-#-#---Declaration---#-#-#-#-#-#-#-#-#-#-#-#-#*)\r\n' a=treeobj.textual_declaration t=t+a.text if treeobj.has_textual_implementation: t=t+'(*#-#-#-#-#-#-#-#-#-#---Implementation---#-#-#-#-#-#-#-#-#-#-#-#-#*)\r\n' a=treeobj.textual_implementation t=t+a.text if treeobj.has_textual_declaration and not treeobj.has_textual_implementation: t=t+'(*#-#-#-#-#-#-#-#-#-#---NOT Implementation visible---#-#-#-#-#-#-#-#-#-#-#-#-#*)\r\n' if treeobj.is_task : exports=[treeobj] projects.primary.export_native(exports,os.path.join(curpath,name+'.task')) if treeobj.is_libman: exports=[treeobj] projects.primary.export_native(exports,os.path.join(curpath,name+'.lib')) if treeobj.is_textlist: treeobj.export(os.path.join(curpath,name+'.tl')) children = treeobj.get_children(False) if children or isfolder: if tp: curpath=os.path.join(curpath,name+'.'+tp) else: curpath=os.path.join(curpath,name) if not os.path.exists(curpath): os.makedirs(curpath) if t: save(t,curpath,name,tp) for child in treeobj.get_children(False): print_tree(child, depth+1,curpath) for obj in projects.primary.get_children(): print_tree(obj,0,save_folder) with open(os.path.join(save_folder,'ExportInfo.txt'),'w') as f: now = datetime.now() infTimeExecution = now.strftime("%Y-%m-%d %H:%M:%S") f.write("Export date and time: "+infTimeExecution + "\r\n" + str(info)) print("--- Script finished. ---") #system.ui.info('save ok') projects.primary.close()
Last updated: 2024-04-30
Post by mubeta on Strange problem with the ‘MC_SetPosition’ function
CODESYS Forge
talk
(Post)
How are the servo drives controlled? EtherCAT, step/dir pulses, other? CANOpen, 1 Mb/s, bus load 35%, cycle time 2ms. Another thought is that - if it's step/dir pulse based control - the pulses from the PLC to the drive are getting missed/lost at high frequencies? If that's the case then there would be multiple troubleshooting steps/corrections that could be investigated. Here, it seems to me that we are getting completely off track with the observed problem. You could try to create a simplified program I had already written this elsewhere. The program before being brought into machines was exhaustively tested in SW emulation and the problem did not occur. However, in emulation I was interested in checking other aspects of the process, not this specific one which is for real a correction made necessary after the fact. The part of the program that does this correction with the function mentioned in the topic, came up from its origins, but I didn't know or didn't think it was really useful. A scruple that later turned out to be necessary. However, for now I do not think I will spend any more time on this verification, already lacking any to do my normal. I remain amazed, however, that a function intended to correct the axis position with the motor in motion and that it should not interfere with this, in fact instead changes behavior as the motor speed changes. Mah! When you manually control the motor directly from the servo drive software at the speeds you are calling for, does it move precisely to the target position? The drive and motor have been working fine for about 10 years. In replacing the machine control system, I opted for CoDeSys where before there was something else. But this is not the subject of the problem. What I need to resolve is the fact that a clutch specially placed at a certain point can slip and, therefore, I have the undeniable need to phase the 'prime mover' to the mechanical position of the machine, detected by a cam for each turn, in order to properly stop at its optimum point. Which for now I have ruled out doing. In fact, if I really have to say, since we have now gone brutally OT, I originally thought that this clutch should only come into action in cases of extreme necessity, as happens in most trials. But this one, the way it is made, slips more easily than I could estimate and the servo-controlled 'prime mover,' and the machine, get out of phase, maybe by a little, but frequently, and when the machine work at it's high speed, (in fact all of the time), I can't adjust properly the 'prime mover' position at fly.
Last updated: 2025-01-18
Post by ryandmg on Web Client (HMI) Disconnects from Webvisu (Weidmuller u-OS)
CODESYS Forge
talk
(Post)
Hey Everyone, I'm having a bit of a struggle finding settings that will reliably maintain a connection between the webvisu and a touchscreen client. Every so often the HMI disconnects and will perpetually display the red spinning arrow with the "Error Happened, Will resume automatically" text. Power cycling the HMI to force a reconnect will re-establish comms. It seems to happen during periods of inactivity if that's a clue. From what I've gathered so far this seems to have something to do with the webvisu update rate, buffer size as well as the visu task scan rate. We first tried the default settings as follows: Webvisu Update Rate: 200 ms Webvisu Buffer Size: 50,000 Visu Task Scan Rate: 100 ms Priority 31 Other Tasks for Reference: Main Task Scan Rate: 100 ms Priority 1 Alarm Manager Scan Rate: 50 ms Priority 31 Ethercat Task: 4 ms Priority 1 This would disconnect some what regularly. We then made the following changes to try and stabilize: Webvisu Update Rate: 150 ms Webvisu Buffer Size: 75,000 Visu Task Scan Rate: 75 ms Kept other tasks the same. This seems to disconnect even more frequently. Also for reference the network is very small and only consists of the PLC, a small switch and the HMI. We're also not controlling frames from outside the visu program itself. The frame changes are all done natively. Any suggestions to get this to stop disconnecting? Oh and whatever the issue is the log does not record it. Figured I would ask here before opening a ticket. Thanks in advance for your help!
Last updated: 2023-09-06
Post by wildcard on Modbus Client Request Not Processed
CODESYS Forge
talk
(Post)
Hi, does anyone has a solution for this issue. I've the same problem. I've implemented a very simple client based on the Modbus Examples and connected the soft PLC to a Modbus Simulator. PROGRAM ModbusClient VAR initDone : BOOL := FALSE; errorID : ModbusFB.Error; client : ModbusFB.ClientTCP; timeout : UDINT := 500000; replyTimeout : UDINT := 200000; aUINT : ARRAY [0..8] OF UINT; clientRequestReadHoldingRegisters : ModbusFB.ClientRequestReadHoldingRegisters; clientRequestsCnt : UINT := 0; clientRequestsProcessCnt : UINT := 0; ipAddress : ARRAY[0..3] OF BYTE := [10,54,0,72]; END_VAR IF NOT initDone THEN initDone := TRUE; client(aIPaddr:=ipAddress, udiLogOptions:=ModbusFB.LoggingOptions.All); client(xConnect:=TRUE, ); clientRequestReadHoldingRegisters(rClient:=client, udiTimeOut:=timeout, uiUnitId:=1, uiStartItem:=0, uiQuantity:=4, pData:=ADR(aUINT[0]), udiReplyTimeout:=replyTimeout); clientRequestReadHoldingRegisters.xExecute := TRUE; clientRequestsCnt := 0; END_IF clientRequestReadHoldingRegisters(rClient:=client, udiTimeOut:=timeout, uiUnitId:=1, uiStartItem:=0, uiQuantity:=4, pData:=ADR(aUINT[0]), udiReplyTimeout:=replyTimeout, xExecute := TRUE); IF clientRequestReadHoldingRegisters.xError THEN clientRequestsCnt := clientRequestsCnt +1 ; errorID := clientRequestReadHoldingRegisters.eErrorID; END_IF clientRequestReadHoldingRegisters(rClient:=client, udiTimeOut:=timeout, uiUnitId:=1, uiStartItem:=0, uiQuantity:=4, pData:=ADR(aUINT[0]), udiReplyTimeout:=replyTimeout, xExecute := NOT clientRequestReadHoldingRegisters.xExecute); When the system is running I do get the following on the logs: 2024-05-13T10:18:07.443Z: Cmp=MODBUS lib, Class=1, Error=0, Info=0, pszInfo= Client.RequestProcessed ClientRequest,16#0164ADC561A0 unitId=1 fc=ReadHoldingRegisters id=2070 state=Error 2024-05-13T10:18:07.443Z: Cmp=MODBUS lib, Class=1, Error=0, Info=0, pszInfo= ClientRequest,16#0164ADC561A0 unitId=1 fc=ReadHoldingRegisters id=2070 change state Error -> None timestamp=63843421226 2024-05-13T10:18:08.444Z: Cmp=MODBUS lib, Class=1, Error=0, Info=0, pszInfo= ClientRequest,16#0164ADC561A0 unitId=1 fc=ReadHoldingRegisters id=2071 change state None -> Init timestamp=63844421420 2024-05-13T10:18:09.444Z: Cmp=MODBUS lib, Class=1, Error=0, Info=0, pszInfo= ClientRequest,16#0164ADC561A0 unitId=1 fc=ReadHoldingRegisters id=2071 change state Init -> Error timestamp=63845421675 But the errorID is jumping between OK and RequestNotProcessed. Any help is very appreciated which gives me a hint what I'm doing wrong. Thanks
Last updated: 2024-05-13
Post by mubeta on Some 'pathetic' errors in SoftMotion program
CODESYS Forge
talk
(Post)
Yes, this is the error the sometimes show up. What make me crazy is the fact that it happens randomly and not each times. I know very well where the problem is, in wich one program row it's located. For each actions of the state machine I have all events recorded with log on text file. it is not problematic for me to find the application point of the fault, but I need to understand why occasionally and for no apparent reason, switching the state machine and thus changing the motion FB, sends the axis into failure (but only occasionally). For example, one case that is often problematic is the execution of the Axis Halt instruction. When, after a MoveAbosulte instruction this returns the event as 'done' and indeed the axis is in standstill, the state machine first sets the move instruction to FALSE, and the next cycle sets the Halt request to TRUE. Some of the time everything works out fine. Occasionally, however, in this exchange, the axis goes into fault, also losing the OPERATIONAL state. Meanwhile, I would like to understand why the motion FB instances must still be called even after the Execute is set to FALSE, especially in view of the fact that the next instruction is programmed to abort the previous one, with BufferMode set to 'Aborting'. All these unnecessary FB calls are an unnecessary overhead on the CPU anyway. Is there any precise rule about when to cease calling the various instances? (It should precisely be the 'done' status that says this one has finished its work).
Last updated: 2024-07-18
Post by tk096 on Some 'pathetic' errors in SoftMotion program
CODESYS Forge
talk
(Post)
Meanwhile, I would like to understand why the motion FB instances must still be called even after the Execute is set to FALSE, especially in view of the fact that the next instruction is programmed to abort the previous one, with BufferMode set to 'Aborting'. All these unnecessary FB calls are an unnecessary overhead on the CPU anyway. Is there any precise rule about when to cease calling the various instances? (It should precisely be the 'done' status that says this one has finished its work). In general: - Motion function blocks have to be called until they report 'Done', 'Error', 'CommandAborted' or a subsequent motion FB with BufferMode=Aborting is started in the current cycle. - Setting the Execute input to FALSE will not abort any ongoing motion of the motion function block. For example, one case that is often problematic is the execution of the Axis Halt instruction. When, after a MoveAbosulte instruction this returns the event as 'done' and indeed the axis is in standstill, the state machine first sets the move instruction to FALSE, and the next cycle sets the Halt request to TRUE. Some of the time everything works out fine. Occasionally, however, in this exchange, the axis goes into fault, also losing the OPERATIONAL state. I think the error SMC_FB_WASNT_CALLED_DURING_MOTION is only a follow-up (and misleading) error that results from the axis not being in operational state anymore (bus problems). Is there an error 'regulator or start not set' in the device log before the error 'motion generating FB wasn't called for at least one cycle'? Which error does the respective function block (Halt.ErrorId) report?