Search talk: LOGGING THE VARIABLE FOR LONG TIME

 
<< < 1 .. 83 84 85 86 87 .. 254 > >> (Page 85 of 254)

Post by jmfernandes on OpenDir always in error CODESYS Forge talk (Post)
Hello I'm trying to use DirOpen to access a directory where then I can read/list the files inside. But I can't list any files because DirOpen.xError is always true. In eError the message is this: " ERROR_UNKNOWN Local library error ID (0: no error; 5101: time out)**** " I have in the file explorer the path 'C:\CodesysTest\Aluminium' and to make sure I also created in the plc a folder to 'prj/Recipes/Aluminium'. I tried using the different paths, but in both it happens the same thing.Inside the folder Aluminium there is two csv files, that I want to list. I added in the library manager CAA Files and CAA Types. I am using the example of https://content.helpme-codesys.com/en/libs/CAA%20File/Current/Examples.html#directory but not matter what I do, I can't get the list the names of the files. What am I missing?
Last updated: 2024-07-31

Post by sturmghost on Mimic behavior of the visualization button element with a custom button CODESYS Forge talk (Post)
Im wondering how Codesys is doing the mouse event capturing with their visualization button element? If you add such a button without configuring any input configuration event (like OnMouseDown) or button state variable and then click on the button, the button changes to the visual pressed state and back if you release the button (so they must react to an OnMouseDown event). But how? If I try to mimic this behavior with my custom button visualization element (like a basic rectangle) I need to use an input configuration event to change the color of the button (to make it look like the button was pressed on OnMouseDown event). When I try to add this button via a Frame-Element to my main visualization page I'm unable to use an input configuration event on the Frame-Element because the input configuration event on the button element won't be evaluated anymore (it seems like you can't stack input fields, e.g. invisible input elements, onto each other). Hence the button is not shown pressed anymore. How they do it?
Last updated: 2024-08-04

Post by t-probst on Strong Private Key Protection for Encryption Certificates CODESYS Forge talk (Post)
Hello, We are trying to implement an automated method of adding of a certificate and private key to the Windows certificate store for encrypting CODESYS projects. We want to do this so that users do not have to deal with details of certificates at all and to prevent user error. We are keen on enforcing strong private key protection since it ensures that a password is required for the certificate to be used to decrypt a CODESYS project. When we add a certificate to the certificate store and enable strong key protection using the Microsoft Management Console Certificates snap-in, it works as expected. However, through this method the user may mistakenly not enable strong private key protection. For the certificates we create programmatically (using Microsoft’s Cryptography Next Generation API in .Net 7) bag attributes are added to the certificate and key by the API. These bag attributes are as follows: Bag Attributes localKeyID: 01 00 00 00 subject=C = xx, ST = xxx, O = xxx, OU = xxx, CN = xxx issuer=C = xx, ST = xxx, L = xxx, O = xxx, OU = xxx, CN = xxx -----BEGIN CERTIFICATE----- [encoded certificate] -----END CERTIFICATE----- After using this certificate with bag attributes to encrypt a CODESYS project, it can’t be decrypted, showing this error: "The specified project could not be loaded. Possible reasons might be: - The project file is corrupted or invalid - The project has been saved with a newer version of the programming system. If this is the case, you can open the project in the corresponding version. Choose "Save as..." with the appropriate storage version, and retry again. - You may not have the necessary permissions to lad the project" We know that the bag attributes are causing the issue because if we manually edit the certificate file to remove them before using the certificate to encrypt a project, the project can be decrypted as expected. However, we are unable to automatically enforce strong key protection using this method. Here is a link to a StackOverFlow question that we have posted recently for this issue: https://stackoverflow.com/questions/76922355/enforcing-strong-private-key-protection-for-x509certificate2-objects-in-net-mod Any help is greatly appreciated.
Last updated: 2023-08-22

Post by thn-power on Codesys Communication Manger - Required information model version exists in the model repository but is not found CODESYS Forge talk (Post)
Hi. Thanks for the answer. I think I found your post on the Wago forum. I have tried installing all different nodeset versions of the opcfoundation.org/UA but neither work. Though I could not find the nodeset version called 15.09.2021 anywhere online. The opcfoundation repository only goes back to version 1.04.11 2022-03-29. Also wondering how I can generate a custom information model that only refrences the latest version of nodesets?
Last updated: 2024-09-19

Post by jwhaley on C0007 Errors CODESYS Forge talk (Post)
I ended up figuring it out It wasn't in my code. It kept taking me to 2 of my visualizations but it wasn't going to anything specific. Figured out it was some arrows that I had made to buttons for a mouse click to go to the other visualizations. I removed the text in the assign box but didn't remove the action "change shown Visualization from the list. If I deleted the images all together, the error went away. That's how I thought to go look at that.
Last updated: 2024-10-10

Post by garrian on How to write multiple coils (Modbus FC15) CODESYS Forge talk (Post)
Thanks for your reply. I belive it is contiguous, I'm writing to adress 0 to 4. Or, do you mean something else? Well, something is happening. If I on the client set adress 1,2,3 to true, only 1 is set to true on the server side. On the client side, the data is array of word. But on the server side, the coils are array of bool. Holding register is array of word on server side. Can this be a problem? Attached screenshot of how it looks at the server side.
Last updated: 2024-11-17

Post by teichhei on The selected container ... does not fit your ticket CODESYS Forge talk (Post)
Update, installed 3.5.19.70 with the same result. The error message is as useful as a chocolate fire guard. The container SN is in the 130-xxx range which should work. The Version, Chip, Rev number don't mean anything to me. There is no SD Card installed. I've also reinstalled a fresh Wago FW22 image, Deployed PFC200 SL and Edge for Linux, still the same result.
Last updated: 2025-01-09

Post by gabrielarffa on Modbus TCP/IP having problems with global variables CODESYS Forge talk (Post)
I'm using Modbus TCP/IP to communicate Codesys with Elipse E3 as the master for a college project. I have made a list of global variables to organize the programming in two different POUs. The problem is, when I try to do the mapping of variables, the program informs me of an error due to the identifiers having a "." on their names. Do I have to reorganize my code to make it an unified block or is there a way to declare their names without changing all the code structure?
Last updated: 2025-05-20

Post by gabrielarffa on Modbus TCP/IP having problems with global variables CODESYS Forge talk (Post)
I'm using Modbus TCP/IP to communicate Codesys with Elipse E3 as the master for a college project. I have made a list of global variables to organize the programming in two different POUs. The problem is, when I try to do the mapping of variables, the program informs me of an error due to the identifiers having a "." on their names. Do I have to reorganize my code to make it an unified block or is there a way to declare their names without changing all the code structure?
Last updated: 2025-05-20

Post by arwie on Use MC_Home without enabling the drive for homing method 35 CODESYS Forge talk (Post)
Is it possible to use MC_Home without enabling the drive (MC_Power)? On the drive the homing method 35 (Homing on current position) has to be executed. The drive has to stay disabled due to safety. This is explicitly allowed by the drive. Unfortunately MC_Home reports the error SMC_REGULATOR_OR_START_NOT_SET when executed. Are there other options to start homing, if not with MC_Home?
Last updated: 2025-06-25

Post by sandro66 on Application-based license Modbus Channels CODESYS Forge talk (Post)
Hi Gatto, Using version 3.5.21.xx, it is no longer possible to use Modbus function blocks (I make extensive use of these FBs.)as shown in the example. https://content.helpme-codesys.com/en/CODESYS%20Examples/_ex_modbus_example.html The compiler detects one Modbus instance for each instance of the communication FB block. The example program above, although simple, reports 8 Modbus instances when compiled with the latest version. Codesys Support says that you must use fieldbus I/O mapping, but this will result in the loss of the ability to programmatically modify communication parameters. Sandro
Last updated: 2025-09-04

Post by svn123 on In Simulation Mode, logic is not executing CODESYS Forge talk (Post)
Please check the attached snapshot. I am converting an int to real and storing in rVlv01_SV and then scaling the value using LIN_TRAFO. In the bottom Status Bar of Codesys, both RUN and SIMULATION are visible. When I enter value 100 as input to INT_TO_REAL instruction and press Ctrl-F7, the value can be seen at the input but the logic seems not to work. I searched for help but could not find anything relevant. What could be the reason. Codesys ver3.5.11 svn
Last updated: 2023-12-25

Post by mp9876 on Device User Logon CODESYS Forge talk (Post)
Hi everyone, Had that problem before where I could not create another user but used the method just above and it worked great. My problem now is that I get this message when attempting to logon to the device: invalid user authentication on the target dev5, the new user created is pretty much a copy of the user 'Owner' except for the password. Any idea as to why I am always getting this "invalid user authetication on the target" message ? Using Codesys V3.5 SP19 Patch 6 + (64 bit) Regards
Last updated: 2024-03-16

Post by gseidel on Discontinuity of A/B/C axis movement. CODESYS Forge talk (Post)
Hi jonasz, you already solved it, I'm answering here for the sake of others with a similar question. You can provide the slope of the A/B/C axis with the U/V/W word. See example 3 here: https://content.helpme-codesys.com/en/CODESYS%20SoftMotion/_sm_cnc_din66025_additional_axis.html If you don't want to change the G-Code, the function block SMC_RecomputeABCSlopes can compute the slopes automatically. https://content.helpme-codesys.com/en/libs/SM3_CNC/Current/SM_CNC_POUs/SoftMotion-CNC/SoftMotion-Function-Blocks/SMC_RecomputeABCSlopes.html Best regards, Georg
Last updated: 2024-04-30

Post by william-blandon on RecipeManCommands.ReloadRecipes CODESYS Forge talk (Post)
Hello. I'm trying to use RecipeManCommands.ReloadRecipes Method for getting recipes from files. When I call the method it does not generate any error but also not reload any recipe to the recipe definition. Actually I have 6 recipe files on the directory PlcLogic. The rest of the methods work creating recipes, saving to file, etc. Does any one have the same issue? it is something to be set on the recipe manager?
Last updated: 2024-05-16

Post by peder on Parker Compax3 controlled by Schneider LMC 201 CODESYS Forge talk (Post)
I have replaced a Parker PAC320 with a Schneider LMC 201 The system has some Parker Compax3 servodrive communicating over EtherCAT. PAC320 is programmed with Codesys 3.5.15. The program is opened in Machine Expert 3.2. But I can not get the commumication running to the Compax3. When I scan for hardware the it seems like the Compax3 is registated, but not the motors. Anyone that have succeded this replacement?
Last updated: 2026-01-13

Post by em1681 on Modbus RTU over 750-652 CODESYS Forge talk (Post)
Hi, It's my first time operating in Codesys 2.3, but I have done a good amount of Codesys programming, so I'm a little familiar. I haven't done a lot of RTU, but a lot of Modbus TCP. I don't have the PLC in my reach at the moment, but I'm trying to be a little ahead. We're adding the 750-652 module to read energy from a flowmeter over RTU. There will only be 1 slave. I attached pictures of my current hardware, PLC code, the register datasheet from the slave and the only modbus serial library I seem to have available. I'm uncertain if this will work. Any help or clarification on how things work will be greatly appreciated. Thanks in advance.
Last updated: 2025-09-01

Post by raghusingh77 on Temu Promo Code ACU934948 get $100 off + $5 extra bonus for new and existing customers CODESYS Forge talk (Post)
$100 Off Coupon Code [ACU934948] Temu, the rapidly growing e-commerce platform, continues to attract shoppers with its incredible discounts and promotions. As of October 2024, customers can take advantage of a variety of coupon codes, including a significant $100 off coupon code [ACU934948], along with additional discounts for new users and existing customers alike. Here’s everything you need to know about maximizing your savings on Temu. Exclusive Discounts for New Users For first-time shoppers, Temu offers an enticing 30% discount on orders. By using the coupon code [ACU934948], new users can not only enjoy this percentage off but also unlock further savings. Specifically, new users can redeem a new user coupon that provides up to 75% off their first order, making it an excellent opportunity for those looking to explore Temu's extensive product range. Massive Savings in October 2024 October is a prime month for deals at Temu. With the coupon code [ACU934948], shoppers can access discounts of up to 90% off select items throughout the month. This promotion is part of Temu's commitment to providing exceptional value, especially during seasonal sales events. Flat Discounts and Bundle Offers The $100 off coupon code [ACU934948] is a standout offer that allows customers to receive a substantial discount on their total order value. This coupon is applicable to both new and existing customers, ensuring that everyone can benefit from significant savings. Additionally, there are bundle offers available that combine this $100 discount with other promotions, potentially allowing customers to save up to 70% on their purchases. Temu Rewards Program for Existing Customers Temu also values its loyal customers through its Rewards Program, which provides exclusive deals and discounts. Existing customers can utilize the same coupon code [ACU934948] to enjoy flat discounts and cash-back offers. For instance, using this code may yield an additional 25% cash back on eligible purchases, enhancing the overall shopping experience. How to Redeem Your Coupons Using Temu's coupons is straightforward: Select Your Items: Browse through Temu’s vast selection of products. Add to Cart: Once you’ve chosen your items, add them to your shopping cart. Apply the Coupon Code: On the checkout page, enter the coupon code [ACU934948] in the designated box and click "Apply." Complete Your Order: Review your discounted total and proceed with payment. Conclusion With its competitive pricing and generous promotional offers like the $100 off coupon code [ACU934948], Temu is making waves in the online shopping arena. Whether you are a new user looking for introductory discounts or an existing customer eager to take advantage of rewards, Temu provides ample opportunities to save significantly on your purchases. Don’t miss out—redeem your coupons today and enjoy a shopping experience filled with incredible value
Last updated: 2024-10-26

Post by george32 on Readable IO names CODESYS Forge talk (Post)
Hello Folks, I have a quite basic understanding of how PLC programming works. However I keep getting stuck on 1 problem I could not get my head around. The problem is as follow: I have a PLC with 60 IO (20 inputs, 40 outputs). Each IO is defined as a function block. Furthermore I have an external IO card connected trough a CanBus connection. This IO card has 4 analog input channels (USINT), 4 digital inputs (Bool) and 4, digital outputs (Bool) Because I have 2 different components which both has data have I made 4 arrays to store the data off every component in one variable. PLC_Input: Array [1..20] of BOOL; PLC_Output: Array [1..40] of BOOL IOCard_Input: Array [1..8] of BOOL IOCard_Output: Array [1..4] of BOOL Because the control and reading of the different in and outputs is done by a TCP connection I want to use some kind of enumeration or struct to give each index a name so that my main would be a little bit more readable instead of all the magic numbers. Also this would make my program more dynamic for the furter in case I need to changes some in the IO nummers. For example: pump is placed on the fysical terminal strip number place 54, which is the 3th output of the IO card in the program: if I am sending a message with value 54 I would like to control IOCard_Output[3]. If there is a solution or methode to get this done, I can eventually do the following in my main program: IOCard_Output[Pump]. I have tried the following: IOCard_Output[Pump - 51] with an enumration but this keeps raising an error I hope some of you could help me further with this problem. In gross lines: I want to couple all the different IO to a more readable name and this readable name should control the right Array index Thanks in advance, George
Last updated: 2024-09-26

Post by hclai on Maximum Array Index Issue CODESYS Forge talk (Post)
I was trying to use a table object in visualization. I want to dynamically show the valid rows in the table. However, it does not work when there is 1 row. i put the maximum array index to 1. it does not show the 1st row. when i change to 2, it show the second row only. my project with older visualization profile version is working perfectly fine. I did some test and realized that i must use a Row Selection variable to change from 0 to 1. With this change of Row selection, then the row 1 will show up.
Last updated: 2025-06-19

Post by cer-wa on Not able to connect multiple profinet encoder in codesys Linux ARM64 CODESYS Forge talk (Post)
Hello, currently im working with a RevPi connect 5 on a codesys project. Up until now I was having a blast because things were going really smooth but for like almost a day im kind of stuck on the integration of multiple profinet sensors into my project. This is kind of a bummer because that should be an easy thing to do. What I tried so far was to create and additional ethernet adapter where I then tried to connect my devices. in the beginning I tried to connect the devices directly which was not working because I could assign the IP-adress only to the ethernet adapter and not to the devices but the device was found in the device repository (this gets important in the second part) So what I tried next was to setup a PN-Controller and connect my devices subsequently to the Controller. Sadly now the devices wont show up in the device repository anymore. To me its not clear why this is happening. And the worst thing is: I went ahead and setup a device completely like I would want to have it in the project and when I then click on scan devices I can even find the device. But it can not be added to project for whatever reason eventhough im 100% certain that the gsdml file is the correct one. Can anyone help me with this. Like I said this seems like an easy thing to do and its taking me way longer than expected already. The only thing that came to my mind why this might not work is because I have codesys license which only allows one profinet instance. Could that be the case? The error message seems then pretty unfit but ok. I will be grateful for every advice. Thanks in advance! Best regards!
Last updated: 2025-09-25

Post by smeitink on Timeout Error in Modbus Communication with WAGO PFC200 and iEM2050 Meter using 750-652 Module CODESYS Forge talk (Post)
Hi all, I'm looking for help with an issue I've come across while trying to facilitate Modbus communication between a WAGO PFC200 PLC using a 750-652 communication module and an iEM2050 Series Single Phase Energy Meter. I believe to have everything wired and setup correcty, but I keep running into a "Error time out" message, and by now I don't really know what else to try. My setup is as follows: A PFC200 Wago PLC, which has 2 750-652 Serial Interfaces extension modules connected to its field bus. I'm using one of these to talk to a Schneider iEM2050 - kWh-meter over modbus. I have connected terminal 23 (A) of the iEM2050 to connector 6 (A) on the 750-652. I have connected terminal 24 (B) of the iEM2050 to connector 2 (B) of the 750-652. I'm using 200mm of twisted together wires to connected them both, and I have placed a 120 ohm resistor between A and B at both ends. I've attached relevant pinout images to this post. I then wrote a simple program that configures the Mobus port, as per the datasheet of the iEM2050. You can find an image of the relavent page attached to this post too. This is my program: PROGRAM PLC_PRG VAR Master: FbMbMasterSerial; xIsConnected: BOOL; xError: BOOL; iIndex: INT := 1; xTrigger: BOOL; utQuery : typMbQuery := ( bUnitId := 1, // The Modbus unit or slave address bFunctionCode := 4, // Function code for reading input registers uiReadAddress := 1829, // adress for the Power on off counter uiReadQuantity := 1 // Quantity of registers to read ); iStep: INT; oStatusModbus: WagoSysErrorBase.FbResult; utResponseModbus: typMbResponse; xConnect: BOOL := FALSE; delayTimer: TON; END_VAR Master( xConnect:= xConnect, I_Port:= _750_652_24_1, udiBaudrate:= 9600, usiDataBits:= 8, eParity:= WagoTypesCom.eTTYParity.Even, eStopBits:= WagoTypesCom.eTTYStopBits.One, eHandshake:= WagoTypesCom.eTTYHandshake.None, ePhysical:= WagoTypesCom.eTTYPhysicalLayer.RS485_HalfDuplex, xIsConnected=> xIsConnected, xError=> xError, oStatus=> oStatusModbus, eFrameType:= WagoAppPlcModbus.eMbFrameType.RTU, tTimeOut:= T#5S, utQuery:= utQuery, xTrigger:= xTrigger, utResponse:= utResponseModbus); delayTimer(IN := TRUE, PT := T#3S); // Use the Q output of the timer to set xConnect after the delay IF delayTimer.Q THEN xConnect := TRUE; END_IF CASE iStep OF 0: //Wacht totdat de master de poort geopend heeft IF xIsConnected THEN iStep := 1; END_IF 1: //Stuur request naar de slave xTrigger := TRUE; iStep := 2; 2: //Wacht totdat de master klaar is met het afhandelen van de request IF NOT xTrigger THEN iStep := 3; END_IF END_CASE The TON delay before opening the port is due to a an error I encountered when opening it straight away. This seems to be a bug, as described here. However, the TON solved that particular issue. I tried reading multiple registers, but like I said, I still always end up with the "Error time out". What else can I test or try at this point?
Last updated: 2024-02-24

Post by simone on Collapse all CODESYS Forge talk (Post)
Hi, I'm wondering if it exist a button or a keyboard shortcut (much much better) for "collapse all" the open folder on a codesys project. It would really be nice to have. Also: Are there some options or configuration for set a default zoom for the different editor (or even one global), for example I would like to have 100% on ST, LD editor and have 80% on Visualization Editor; and also have a button to set all the zooms to default, now it seems that every file mantain the one previously set. I'm working with the 3.5.20.10 right now Thanks!
Last updated: 2024-11-21

Post by voffi on projects.open not working for file based storage project CODESYS Forge talk (Post)
Hello! Opening a project from a python script given at the CODESYS command line does not work for me with a file based storage project. Example: Running projects.open("test.project", primary = True) works but converting the project to a file based storage project and then give the folder name as an argument to project.open Running projects.open("test.fbsproj", primary = True) does not work. We decided to work with file based storage for the project. Is there a scripting API for file-based storage to e.g. convert it while running the script back or how to open file based storage project with projects.open? Thank you! voffi
Last updated: 2025-09-05

Post by sean-barton on Function block method default arguments CODESYS Forge talk (Post)
I have default arguments specified for function block methods but when calling a method, an error is produced requiring me to supply all the arguments despite there being default values. According to the online documentation, under section "Calling a Method" and subsection "argument passing" of the following link: https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_obj_method.html "Passing an argument for an input ... can be omitted ... for which a default or initial value was specified in the declaration..." I have found this to be the case for all Codesys IDEs I've used, 3.5.11, 3.5.16, 3.5.17, 3.5.19. Am I missing something?
Last updated: 2023-12-21

<< < 1 .. 83 84 85 86 87 .. 254 > >> (Page 85 of 254)

Showing results of 6328

Sort by relevance or date