General question about library versions
Last updated: 2024-05-29
Post by zer0g on Modbus Client Request Not Processed
CODESYS Forge
talk
(Post)
Hi, I have the same problem as the guys above. Any solution or hint in the right direction is appreciated. Codesys version 3.5.19.2, Lib version: 4.4.0.0. Thank you!
Last updated: 2024-05-29
Post by paro on General question about library versions
CODESYS Forge
talk
(Post)
I think you can use the newer versions. For a explanation from CODESYS, please read this post: https://www.codesys.com/the-system/versions-modularization.html
Last updated: 2024-05-29
Post by paro on "You are using inconsistent overlay settings, please check your compiler defines for the current application" error
CODESYS Forge
talk
(Post)
Disable the setting "Support client animations and overlay of native elements" in the Visu Manager. Activating this setting should also set a compiler define (GENERATE_OVERLAY_VISU). Maybe the compiler define is set and the feature is not activated in the visu manager or or the other way round.. rightclick the Application -> Properties -> Build https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_dlg_properties_build.html
Last updated: 2024-05-29
"You are using inconsistent overlay settings, please check your compiler defines for the current application" error
CODESYS Forge
talk
(Thread)
"You are using inconsistent overlay settings, please check your compiler defines for the current application" error
Last updated: 2024-05-29
Post by paro on send appliaction files to wago plc (codesys 3.5) via ssh
CODESYS Forge
talk
(Post)
Hi, it is enough to copy the files to /home/codesys/PlcLogic/Application and adding the lines [CmpApp] Application.1=Application to the eRUNTIME.cfg, if your Application in your program is also called "Application". Reboot -> Bootapp should be loaded. If not please check the log /var/log/runtime.log There should be a line which explains why the bootproject is not loaded.
Last updated: 2024-05-29
Library error after creating project from python
CODESYS Forge
talk
(Thread)
Library error after creating project from python
Last updated: 2024-05-29
Codesys HMI Redundancy
CODESYS Forge
talk
(Thread)
Codesys HMI Redundancy
Last updated: 2024-05-30
Post by arrotek on Codesys HMI Redundancy
CODESYS Forge
talk
(Post)
Is there a way to run Codesys HMI on two different PC's and have the web visu clients fail over to the HMI instance that is wokring or running?
Last updated: 2024-05-30
Post by paro on Modbus Client Request Not Processed
CODESYS Forge
talk
(Post)
Hi, works in my case if I increase the timeout! to_udint(t#100ms) -> 100 -> 100us.. FUNCTION_BLOCK MODBUS_master_example_ST VAR initDone : BOOL := FALSE; aIPAddress : ARRAY [0..3] OF BYTE := [127,0,0,1]; clientTcp: ModbusFB.ClientTcp; // buffer to read input registers aDataInputRegisters : ARRAY[0..9] OF UINT; // some client requests clientRequestReadInputRegisters: ModbusFB.ClientRequestReadInputRegisters; xExecute: BOOL; uistart: UINT := 100; udiTimeout1: UDINT; END_VAR IF NOT initDone THEN initDone := TRUE; // configure clientTcp clientTcp(aIPaddr:=aIPAddress, uiPort:=502, udiLogOptions := ModbusFB.LoggingOptions.All); // configure clientRequestReadInputRegisters clientRequestReadInputRegisters(rClient:=clientTcp, uiUnitId:=1, udiTimeout:=1000000); // 1sec END_IF // call the client FB's clientTcp(); clientRequestReadInputRegisters(rClient:=clientTcp,xExecute := xExecute AND NOT clientRequestReadInputRegisters.xBusy ,uiStartItem:=uistart, uiQuantity:=3, pData:=ADR(aDataInputRegisters[0]));
Last updated: 2024-05-30
send appliaction files to wago plc (codesys 3.5) via ssh
CODESYS Forge
talk
(Thread)
send appliaction files to wago plc (codesys 3.5) via ssh
Last updated: 2024-05-30
Non-existing identifiers
CODESYS Forge
talk
(Thread)
Non-existing identifiers
Last updated: 2024-05-30
Post by zer0g on Modbus Client Request Not Processed
CODESYS Forge
talk
(Post)
I'm using the code bellow which is based on the Codesys example: FUNCTION_BLOCK MODBUS_master_example_ST VAR initDone : BOOL := FALSE; aIPAddress : ARRAY [0..3] OF BYTE := [127,0,0,1]; clientTcp: ModbusFB.ClientTcp; // buffer to read input registers aDataInputRegisters : ARRAY[0..9] OF UINT; // some client requests clientRequestReadInputRegisters: ModbusFB.ClientRequestReadInputRegisters; xExecute: BOOL; END_VAR IF NOT initDone THEN initDone := TRUE; // configure clientTcp clientTcp(aIPaddr:=aIPAddress, uiPort:=502, udiLogOptions := ModbusFB.LoggingOptions.All); // configure clientRequestReadInputRegisters clientRequestReadInputRegisters(rClient:=clientTcp, uiUnitId:=1, udiTimeout:=TO_UDINT(T#1000MS)); END_IF // call the client FB's clientTcp(); clientRequestReadInputRegisters(rClient:=clientTcp,xExecute := xExecute AND NOT clientRequestReadInputRegisters.xBusy ,uiStartItem:=2, uiQuantity:=3, pData:=ADR(aDataInputRegisters[0])); As you can see the clientTCP is called cyclically with the same result.
Last updated: 2024-05-30
Post by jaspergain on Non-existing identifiers
CODESYS Forge
talk
(Post)
Hi, I'm using SP19 Patch 5, the software is also updated from SP18 Patch 5, I forgot to mention this. I will try a newer patch to see if it fixes the issue. Thanks for your help.
Last updated: 2024-05-30
Post by sigurdrb on send appliaction files to wago plc (codesys 3.5) via ssh
CODESYS Forge
talk
(Post)
Okey, I will try this out. Thank you for your answer!
Last updated: 2024-05-30
Post by bartg on Open a POU in the editor via scripting
CODESYS Forge
talk
(Post)
Hi, I would like to automate opening some specific pous and visualisations in the codesys environment I found out that I can open it by using : system.commands["42f6acb9-bd6e-42e7-94bb-6e2a03973b83"].execute() But the POU has to be selected in the Devices or POUs navigator. Does anyone know how I can select a specific POU in the navigator? Or how I can open a specific POU? I can retreive the guid of the POU. Thx
Last updated: 2024-05-30
Post by zer0g on Modbus Client Request Not Processed
CODESYS Forge
talk
(Post)
Hi, Thank you for your suggestion but the problem is fixed after I disabled and enabled the network adapter from Windows settings.
Last updated: 2024-05-30
Modbus Client Request Not Processed
CODESYS Forge
talk
(Thread)
Modbus Client Request Not Processed
Last updated: 2024-05-30
Open a POU in the editor via scripting
CODESYS Forge
talk
(Thread)
Open a POU in the editor via scripting
Last updated: 2024-05-30
Post by starmaxou on How to download dependencies packages for CODESYS Control for Raspberry Pi SL ?
CODESYS Forge
talk
(Post)
Hi everyone, I'm trying to install the CODESYS Control for Raspberry Pi SL package. The computer with CODESYS software is offline for security reasons. So, I downloaded the package on another computer and installed it manually. But this package has dependencies packages: CODESYS.Control SL Extension Package, V4.0.0.0 CODESYS.Control SL Deploy Tool, V4.10.0.0 As I said, the computer with CODESYS is offline. I cannot use the package installer to search for these packages. I did not find them in Codesys Store with another computer. Do you know where to find and download them? Thank you in advance for your help!
Last updated: 2024-05-30
Post by mp9876 on Problems with simulation in Window 10
CODESYS Forge
talk
(Post)
Hi Eschwellinger, sorry for so late reply but I found a solution back then; uninstall completely Codesys V3x64 and re-installed Codesys V3x32 to properly note the password I created and everything went ok. thank you for your suggestion and have a good day/evening Mike
Last updated: 2024-05-30
Post by greenwood on CODESYS Control Raspberry Pi mit Servotreiber T6 von StepperOnline
CODESYS Forge
talk
(Post)
Hallo, ich versuche, eine Modbus-RTU-Kommunikation zwischen meinem Raspberry Pi mit CODESYS Control für Raspberry Pi 64 SL und einem Servotreiber von StepperOnline, Typ T6, herzustellen. Die Verbindung ist wie folgt: RJ45-Stecker am Servotreiber -> Kabel mit RJ45 an einem Ende und USB-A-Stecker am anderen Ende -> Seriell-zu-USB-Konverter -> Raspberry Pi. Der Seriell-zu-USB-Konverter und die Kabel habe ich zusammen mit dem Motor und Treiber von StepperOnline gekauft und sie sind dafür gedacht, den Servotreiber mit einem Computer zu verbinden, auf dem deren Setup-Software läuft. dmesg | grep tty auf dem Pi sagt mir, dass der USB-zu-Seriell-Konverter auf ttyusb0 ist. Ich weiß nicht, wie man das in einen COM-Port übersetzt, ich habe COM 1 genommen. Ich habe ein Projekt in Codesys erstellt und ein Modbus_COM-Gerät hinzugefügt, einen Modbus_Master_COM_Port und einen Modbus_Slave_COM_Port angehängt. Auf der Registerkarte "Allgemein" des Modbus_COM habe ich die folgenden Werte eingestellt: Slave address 1 Baud rate 9600 Parity None Data bits 8 Stop bits 2 Ich habe den Servotreiber auf die gleichen Werte eingestellt. (Ich habe auch andere Werte getestet, aber mit dem gleichen Ergebnis). Auf der Registerkarte "Modbus Slave Channel" des Modbus_Slave_COM_Port habe ich einen Kanal hinzugefügt und die folgenden Werte eingetragen: Access type Read Holding Registers (Function Code 3) Read Register offset 0x0000 Length 1 Ich habe noch keinen Code geschrieben, weil ich noch nicht herausgefunden habe, wie man die Kommunikation programmiert. Wenn ich das Projekt zum Raspberry Pi herunterlade scheint der Modbus_Master_COM_Port zu laufen (grünes Symbol), aber der Modbus_Slave_COM_Port nicht (rotes Dreiecksymbol). Wenn ich einen anderen COM-Port eintrage, haben sowohl der Master als auch der Slave das rote Dreiecksymbol. Ich habe dies auch mit meinem Windows-PC unter Verwendung von Codesys Control Win 64 versucht und die gleichen Ergebnisse bekommen. Ich wäre dankbar für jede Hilfe oder Tipps, wie ich den Grund dafür herausfinden kann, warum der Servotreiberreiber nicht reagiert.
Last updated: 2024-05-31
Post by micik on "CAA" meaning in library names
CODESYS Forge
talk
(Post)
Hello, what CAA stands for? Since it is a collection of different libraries, does it mean it is created by some specific organization? Thanks!
Last updated: 2024-05-31
Opto 22 Groov PR2 Modbus TCP Master communication
CODESYS Forge
talk
(Thread)
Opto 22 Groov PR2 Modbus TCP Master communication
Last updated: 2024-05-31
Post by kislov on "CAA" meaning in library names
CODESYS Forge
talk
(Post)
CODESYS Automation Alliance I doubt that this organization still exists in any form.