Post by spiessli on Raspberry Pi 4 with Legacy Drivers and Codesys 3.5.19 Patch 4 CODESYS Forge talk (Post)
Thanks for the suggestion, I have tried it eagerly: I have updated all packages to latest version with Codesys Installer and installed newest runtime and gateway on Raspberry Pi. Unfortunately, the error is still there. As soon as I add the SM_Drive_Servo to the device tree, I get the error below when generating the code. Reverting SM3_Basic to version 4.14 makes the error disappear. ------ Übersetzungslauf gestartet: Applikation: Device.Application ------- Code typisieren... Code erzeugen... [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet Übersetzung abgeschlossen -- 15 Fehler, 0 Warnungen : Kein Download möglich
Last updated: 2023-12-20

Post by manuknecht on Persistence Manager does not save alphabetically first value CODESYS Forge talk (Post)
After some more digging I realized that I get an error on the PLC Logger saying PersistenceChannel: 150 (invalid type in data: SimpleLibrary). I suppose the issue could be found in the ConfigData, which is automatically generated and which looks like this: 1 9##83 SimpleLibrary#GVL.aMoreZeros.[1]#0#64512#15#0 <[2]#0#64520#15#0 <[3]#0#64528#15#0 <[4]#0#64536#15#0 <#0#64544#15#0 <[6]#0#64552#15#0 <<lrVar#0#64560#15#0 <strVar#0#64428#16#80 <uiDummy#0#64370#11#0 Perhaps the fact that the variable is stored within a library confused the compiler? I tried changing the PersistenceChannel parameters to xCompressTags := FALSE which changed the entry in the data file from _xCompressTags BOOL:TRUE _xCompressTags BOOL:FALSE but the actual content of the data file and also the config data did not change.
Last updated: 2023-10-17

Post by riccardo on VisuElems.CurrentUserGroupId is not stable CODESYS Forge talk (Post)
Goodmorning TimvH, Thanks for the reply. I don't know if your solution solve my trouble yet, I am going to see the link you sent me. In the mean time I try to explane better what I need to do. I have a turbine system that get in alarm under some condition (E.g low speed of turbine) and block the itself. When the system is stoped there is no speed turbine and the system cannot start. To give to the operetor the possibility to bypass the alarms, there is an acknoledgement alarm pushbutton. This bypass must not work for everyone but only for those client that perform the login by (User Management). Furthermore, if the user perform the (manual or automatic) logout in alarm conditions, the acknowlegment must be annulled and block the system again. To do this, I need to know if an operator is logged in the page and is working to fix the problem; otherwise the syste must autoturn off again. Now I go to study your solution, if I have explaned better and you have another idea tell me please.
Last updated: 2023-11-16

Post by ewi04 on Git with visu CODESYS Forge talk (Post)
Hi, I have several problems with the git extension. Situation: I am working with Codesys v3.5 SP19 Patch 1 and Git V1.2.1.0. The remote repository is GitLab Community Edition v16.1.2. I am working on a project with one other person. Problems: 1: After each start of Codesys all of the visu pages are marked as modified. So we have to discard all changes first. Otherwise the history is not clean and the merge request becomes more complex. I tested it with a new project and only local. I made the observation, that a page is not marked as modified when it is committed a second time (after a restart of codesys). But this is necessary after every change of a page. However, since we are working in a team, it seems we are playing ping-pong and so all pages are marked as modified on each startup. 2: Each image pool causes a parent child conflict. Also in my local project. The only solution that I have found, is to ignore the issue. Does anyone have the same problems? I think it looks more like bugs. Thanks ewi04
Last updated: 2023-11-22

Post by psychoengineer on Cannot Save CSV File on Windows Computer Using CODESYS and Control Win CODESYS Forge talk (Post)
I am currently working on a project using CODESYS and Control Win on a Windows computer. I've encountered an issue where I am unable to save a CSV file. I have followed the standard procedures and used the appropriate file handling functions, but the file is not being created or saved as expected. IF xStartTest THEN sFileName := '\logs.txt'; sFileName := CONCAT(gvl.g_sMainDirectory, sFileName); sFileNameCopy := '\CAAFileCopy.txt'; sFileNameCopy := CONCAT(gvl.g_sMainDirectory, sFileNameCopy); //eWriteState := FILE_OPEN_TRIGGER; xTestDone := FALSE; xError := FALSE; xStartTest := FALSE; END_IF VAR_GLOBAL g_sMainDirectory : STRING := 'C:\LogFiles'; // file path for CSV file END_VAR Despite this, the file does not appear in the specified directory, and no error messages are being generated. I've checked the directory permissions and ensured that the path is correct. Has anyone else experienced a similar issue or have any suggestions on how to resolve this? Any help would be greatly appreciated. Thank you!
Last updated: 2024-07-04

Post by marek71 on Ambiguous use of name - CO136 CODESYS Forge talk (Post)
My PLC is WAGO PFC200 Firmware Revision 26. target After updating WAGO_Devices_and_Libraries with newer Firmware 27, CODESYS wants to update all libraries to new versions. I will only add that I did not update the Firmware in the PLC. After compiling the program, I received the following errors: ------ Build started: Application: Device.Application ------- Typify code... [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): FbSerialInterface_internal: C0136: Ambiguous use of name 'RTS_IEC_HANDLE' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): FbSerialInterface_internal: C0136: Ambiguous use of name 'RTS_IEC_RESULT' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): Initialize [FbSerialInterface_internal]: C0032: Cannot convert type 'Unknown type: 'RTS_INVALID_HANDLE'' to type 'POINTER TO BYTE' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): Initialize [FbSerialInterface_internal]: C0136: Ambiguous use of name 'RTS_INVALID_HANDLE' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): Initialize [FbSerialInterface_internal]: C0046: Identifier 'RTS_INVALID_HANDLE' not defined [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): comextra_is_tx_empty: C0136: Ambiguous use of name 'RTS_IEC_HANDLE' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): comextra_get_line_state: C0136: Ambiguous use of name 'RTS_IEC_HANDLE' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): comextra_is_line_available: C0136: Ambiguous use of name 'RTS_IEC_HANDLE' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): COMSW_SET_MODE: C0136: Ambiguous use of name 'RTS_IEC_HANDLE' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): comextra_set_line_state: C0136: Ambiguous use of name 'RTS_IEC_HANDLE' Compile complete -- 10 errors, 0 warnings Build complete -- 10 errors, 0 warnings : No download possible The problem was caused by the WagoSysPlainMem(WAGO) library in the original version 1.5.3.0 after updating to 1.5.3.1. After returning to version 1.5.3.0, the problems disappeared. Probably the version number of this library is responsible for supporting the appropriate Firmware Revision. Can anyone confirm or deny my suspicions?
Last updated: 2024-07-06

Post by tyronnosaurus on ReceiveWatchdog FB not working on J1939 P2P PGNs CODESYS Forge talk (Post)
Hi guys. I've got a device that sends a status message over J1939 and a PLC running Codesys to receive it. This message uses a P2P PGN (as opposed to a broadcast PGN). Codesys can only read it if I mark the J1939_ECU as "Local" (see screenshot 1). The message is received correctly, that is not the problem. The problem is detecting if the message stops being received. Local ECUs have no Watchdog checkbox to detect if the message has been received in the last X seconds. In order to implement a watchdog, I've used a ReceiveWatchdog FB. The same code works well for any non-P2P message, but doesn't work for this particular P2P message I'm trying to monitor. Even if I physically disconnect the device, ReceiveWatchdog.xBusy stays True, and ReceiveWatchdog.xError never triggers due to a timeout error. Is there any caveat in the ReceiveWatchdog FB that makes it unable to monitor P2P PGNs in Local J1939_ECUs?
Last updated: 2024-07-11

Post by paulorb on STRUCT AT %MW1000 CODESYS Forge talk (Post)
Hi I am trying to use STRUCT to parse commands from Modbus/TCP, Modbus client will fill the bytes related to a specific command (type, parameters), then PLC (Codesys) will access the command parameters. A STRUCT will simplify a lot the process of parsing the data, so I don't need to parse byte per byte, address will be mapped to a struct and I can use it for parsing the data. From what I understood, the compiler does not allow me to specify the location of the struct for a %MW register. VAR_COMMAND AT %MW1002: structGenericModbusCommand; This will throw: Bad declaration, use '%ML' for 'structGenericModbusCommand' variable But If I change it to %ML, when you go online you see that it is actually allocating the struct in another memory address. When we go online, on GVL we can see: VAR_COMMAND. structGenericModbusCommand %ML1002 commandType COMMANDTYPE %MB8016 ... %MB8020 I am not specifying a pointer or a reference it is a struct type, why is it mapping to a %MW location (random one). How can I control where it is mapping to? I need a consistent way to map STRUCT to specific modbus address. Is it possible? Thanks, Paulo Note I am using a Codesys OEM: Schneider Machine Expert Logic Builder (M241)
Last updated: 2024-08-13

Post by ruobian on Analog Input Delay Timer CODESYS Forge talk (Post)
Hello there, I am new here and in programming. I need help with the basics. I am trying to do what I mentioned in the title. I have an analog input. So I have a real or integer data type value. I want to delay it. TON and TOF only work with bool. I think there is a function block that has two inputs, 1 for real or int and 1 for bool. And if bool is true, it will give the output as real or int. I don't know but I need something like this. Actually, it is not exactly like that. In other words, it will not show the real value at the input at the output after a certain period of time. I want it to show the real value from 2 seconds ago continuously. The purpose of doing this is to compare the real value I received with the value from 2 seconds ago and find out whether it went up or down. I am using only FBD. Please help me with this. Thanks in advance.
Last updated: 2024-08-20

Post by otbeka on CmpCrypto CryptoGenerateHash Not Outputting CODESYS Forge talk (Post)
Hi, I have been trying to use CryptoGenerateHash from the CmpCrypto Implementation library. My code is taken almost directly from the CryptoDemo.project example provided on Codesys Forge, yet the CryptoGenerateHash function does not write to the address listed in pHash. RTS_IEC_RESULT is OK, but I am getting nothing out of the function. No errors either, all my libraries are up to date. Any help would be appreicated! PROGRAM PLC_PRG VAR sMessage : MESSAGE := 'The red fox runs across the ice'; abyHashCode : HASH_CODE := [ 16#52, 16#ED, 16#87, 16#9E, 16#70, 16#F7, 16#1D, 16#92, 16#6E, 16#B6, 16#95, 16#70, 16#08, 16#E0, 16#3C, 16#E4, 16#CA, 16#69, 16#45, 16#D3 ]; xMessageOK : BOOL; END_VAR xMessageOK := CheckMessage(sMessage, abyHashCode); FUNCTION CheckMessage : BOOL VAR_INPUT sMessage : REFERENCE TO MESSAGE; abyHashCode : REFERENCE TO HASH_CODE; END_VAR VAR _hHASH : RTS_IEC_HANDLE := CryptoGetAlgorithmById(ui32CryptoID:=RtsCryptoID.HASH_SHA1, pResult:=0); Result : RTS_IEC_RESULT; bsMessage : RtsByteString := (ui32MaxLen:=SIZEOF(sMessage), pByData:=ADR(sMessage), ui32Len:=TO_UDINT(LEN(sMessage))); abyNewHashCode : HASH_CODE; bsNewHashCode : RtsByteString := (ui32MaxLen:=SIZEOF(abyNewHashCode), pByData:=ADR(abyNewHashCode)); diCmpResult : DINT; END_VAR Result := CryptoGenerateHash(hAlgo:=_hHASH, pData:=ADR(bsMessage), pHash:=ADR(bsNewHashCode)); diCmpResult := SysMemCmp(pBuffer1:=ADR(abyHashCode), pBuffer2:=ADR(abyNewHashCode), udiCount:=SIZEOF(HASH_CODE)); CheckMessage := diCmpResult = 0;
Last updated: 2024-09-06

Post by ricola on ERROR: CodeMAccess2: Used CmRuntime 2.61.2705.500 is too old CODESYS Forge talk (Post)
hi there , can someone tell me how to deal with this error , please? I use the Linux ARM64SL (4.11) on a bullseye distro and when I want to update or install some package, I have the following reply : pi@NanoPi-R5C:~$ sudo apt upgrade Reading package lists... Done Building dependency tree... Done Reading state information... Done You might want to run 'apt --fix-broken install' to correct these. The following packages have unmet dependencies: ** codesyscontrol : Depends: codemeter but it is not installable or codemeter-lite but it is not installable** E: Unmet dependencies. Try 'apt --fix-broken install' with no packages (or specify a solution). and if I try apt --fix-broken install as suggested, I have a proposal to uninstall codesyscontrol ... :-D so I tried to search if there is some Codesys repo: nothing, then I tried to see if ther was something inside Codesys dev (V3.5.20) and I only found that by reading/requesting my device, i spoted that codemeter was too old . I don't see how to deal with this issue. is there a codemeter.deb somewhere ? thanks in advance for any help.
Last updated: 2024-09-17

Post by lbartik on J1939 TX/RX PDU1 CODESYS Forge talk (Post)
Is it possible to transmit a PDU1 PGN using the J1939 manager and local device? What if I need to transmit a PGN RQST via 0xEA00 (PGN 59904)? How would I do this P2P (Destination < 0xFF) or broadcast (Destination 0xFF)? I don't think this is possible for any destination type. I don't think it's possible to receive broadcast PDU1 messages either. For example, an address claim PGN 60928 (0x18EEFF80) is addressed to all nodes (0xFF) and not any specific local device so it will be filtered out. These are major oversights in the IoDrvJ1939 library to not support every PDU1 RX/TX scenario. IoDrvJ1939 supported scenario: 1. Receive (RX) PDU1 (P2P) destination-specific (PDU-specific < 255) to local device with matching address IoDrvJ1939 unsupported scenarios: 1. Receive (RX) PDU1 (P2P) global (PDU-specific = 255) 2. Transmit (TX) PDU1 (P2P) global (PDU-specific = 255) 3. Transmit (TX) PDU1 (P2P) destination-specific (PDU-specific < 255)
Last updated: 2024-09-23

Post by breiter on Frustration-Fueled Feedback on Project File Management and Git Integration CODESYS Forge talk (Post)
Hi, supporting a text based storage format is on our roadmap, see https://www.codesys.com/the-system/releases-updates-lifecycle/release-plan-roadmap.html It will be an Add-On feature called "File Based Storage" for the professional developer edition. Structured text POUs will be stored as plain text. Other graphical languages will remain in an xml format. You will be able to switch the storage type for projects. Certain workflows will become easier this way. Nevertheless restrictions will remain because of CODESYS specific storage logic (for example how methods below function blocks are stored as file). So merging using our Git Integration Add-On remains the recommended workflow. A workflow involving Visual Studio Code as the main IDE is not supported. Simply because many topics like library management, task configuration or fieldbus configurators are not available for VS Code. A PLC project is a lot more than just some ST POUs. Best Regards
Last updated: 2024-10-16

Post by andrax on CodeSys Raspberry pi I2C driver not found CODESYS Forge talk (Post)
Hi, Communication with the ADS1115 is actually simple. 1. write config 2. write address pointer 3. read conversation register The ADS1115 works like a multiplexer. This means that you do this individually for each channel that you want to read. e.g: Channel 1: write config > write address pointer > read conversation register Channel 2: write config > write address pointer > read conversation register Channel 3: write config > write address pointer > read conversation register Channel 4: write config > write address pointer > read conversation register then you start again from the beginning You can also omit individual channels or read only one. It doesn't matter. I have written the driver so that I can also use it on the TCA9548. The driver is from Stefan Dreyer. In your case, the driver works and communication with the ADS1115 is running. As you can see, the cfgWrong:=FALSE If you could not write or read data, cfgWrong:=TRUE; This means that either something is wrong with your ADS1115 or you have connected something incorrectly. Question: what voltage do you want to measure?
Last updated: 2024-11-08

Post by cihangur on OpC UA server on Raspberry Pi 64 SL runtime CODESYS Forge talk (Post)
Hello everyone, I wanted to write here because it is a similar and the most up-to-date topic. I want to connect to CoDeSys Win V3 x64 - 3.5.19.50 with OPC UA using WinCC Advanced V17. (Or to a PLC with CoDeSys Version 4.10.0.0) My settings are exactly the same as the previous comment. I even tried many different settings. I can access all CoDeSys OPC UA variables via TIA Portal IDE and add them to my HMI tags. When WinCC RT Advanced is started, it gives a warning that the connection could not be established and does not update the variables. I can connect to Inovance AM600 using CoDeSys Target version 3.5.11.50. (The same version Win x64 is also connected.) However, a security setting in the current versions prevents me. I would be very happy if those who have up-to-date experience on this issue and find a solution share it. The CoDeSys Security Settings which I can access variables with TIA Portal: CommunicationPolicy: POLICY_BASICSHA256SHA256 CommunicationMode: ALL Activation: Activated UserAuthentication: ENABLED Server Certificate: Valid until 2034 Greetings.
Last updated: 2024-12-06

Post by dominggus on FileDialog - OnDialogClosed not called anymore CODESYS Forge talk (Post)
Hi, since the latest update it seems the OnDialogClosed is not called anymore?? using CODESYS SP20 Patch 3 with CODESYS Visualization 4.6.0.0 I am using LoadWriteRecipe to load a recipe file from disk (with some custom dialog settings), and I need to run a function (Recipes_LoadFromRecipeData()) afterwards which I execute when OnDialogClosed is closed with OK button. See attached screenshot and code below: *** OnDialogClosed : Recipes_OnLoadFileDialogClosed(pClientData): *** // the DialogManager is provided via the implicitly available VisuManager dialogMan := VisuElems.g_VisuManager.GetDialogManager(); IF dialogMan <> 0 AND pClientData <> 0 THEN FileOpenCloseDialog := dialogMan.GetDialog('VisuDialogs.FileOpenSave'); // gets the FileOpenSave dialog IF FileOpenCloseDialog <> 0 THEN result := FileOpenCloseDialog.GetResult(); // gets the result (OK, Cancel) of the dialog IF result = VisuElems.Visu_DialogResult.OK THEN Recipes_LoadFromRecipeData(); END_IF END_IF END_IF *** OnMouseClick: Execute ST-Code *** // override FileOpenSave Dialog settings // Visu_FbFileListProvider.Initialize(stDirectory, stFilter, stFileIn, stTitle, iRowCount, bBrowseDirectory, bTouch) VisuDialogs.g_FileListProvider.Initialize('./', '*.bunkerrecipe', '', 'Load recipe', 20, TRUE, FALSE); VisuDialogs.g_FileListProvider(); This used to work in CODESYS v3.5 SP20 Patch 1, but it seems it doesn't work anymore unfortunately? The OnDialogClosed just never seems to be called anymore....
Last updated: 2024-12-18

Post by faceplant on Comparison via CLI is broken CODESYS Forge talk (Post)
Hello! I am trying to compare 2 projects via the --compare CLI option. In the docs for the --compare option, it describes the usage as .\CODESYS.exe --compare "project path 1" "project path 2". I store my projects in WSL2 on my windows machine. Since CODESYS is happy to open those projects via a path like \\wsl.localhost\home\project.project. So, to compare, I use the command .\CODESYS.exe --compare "\\wsl.localhost\home\prog1.project" "\\wsl.localhost\home\prog2.project". This results in CODESYS just opening the project and starting, not comparing the two projects. No errors are thrown, and I know the paths are correct since I can open both independently in CODESYS, and I can compare them manually through the CODESYS UI. I have also tried moving my projects to the Windows 11 OS and still have the same issue. CODESYS opens the project and does not actually compare them. I am using CODESYS profile v3.5 sp20 patch 1. What is the correct way to compare 2 projects using the --compare CLI option?
Last updated: 2024-12-18

Post by sean-barton on Ambiguous namespace in library dependencies CODESYS Forge talk (Post)
I am trying to install the MQTT Client SL in an existing project I have been working on for years. After adding the library to the project, and without adding any other code, upon building I get a C0180: Ambiguous namespace 'MBM' error between the memory block manager (MBM) in the NetBaseSrv dependency of the MQTT Client SL library and the memory block manager (MBM) in the CAA CanL2 dependency of the 3S CANopen stack library. I have tried: * setting "Only allow qualified access to all identifiers." in the properties for both the parent libraries. * deleting the 3S CANopen stack library. Upon (re)building the error simply points to another conflicting library - there are many. * deleting the Library Manager and rebuilding it. * adding the memory block manager library (used in the NetBaseSrv) manually and changing its namespace to MBM3S. None of the above allow me to access the MQTT library through its namespace (MQTT). Adding the memory block manager manually removes the C0180 error, but the MQTT library is not accessible - i.e. mqttClient : MQTT.MQTTClient; highlights the mqttClient as "Identifier 'MQTT.MQTTClient' not defined". Is there anything else I can try?
Last updated: 2025-01-09

Post by trusty-squire on Strange problem with the ‘MC_SetPosition’ function CODESYS Forge talk (Post)
Here, it seems to me that we are getting completely off track with the observed problem. If questions clarifying the details of the installation are problematic, it's best to include those details in the original question then... I had already written this elsewhere. The program before being brought into machines was exhaustively tested in SW emulation and the problem did not occur. Testing the full program in emulation is entirely different from creating a simplified program to isolate the function causing problems in the real world. I would recommend trying it to isolate the issue. The drive and motor have been working fine for about 10 years. In replacing the machine control system, I opted for CoDeSys where before there was something else. But this is not the subject of the problem A simple "yes" is the correct answer to my question here... Anyways, you seem to be a very knowledgeable expert, good luck on your problem!
Last updated: 2025-01-18

Post by pernockham on Inheritence of struct, CODESYS Forge talk (Post)
Im looking for a way to define predefined version of the same structures through "extends"/inheritance. What I want to do is best shown with an example: TYPE log_item_val_type : ( BOOL_ := 0, INT_, REAL_, STRING_ ); END_TYPE TYPE LOG_DATA_BASE STRUCT val_type : log_item_val_type; (* value, name etc *) ENDSTRUCT ENDTYPE (* this/below is not possible as I understand from the compiler?? *) TYPE LOG_DATA_BOOL extends LOG_DATA_BASE : STRUCT val_type : log_item_val_type := log_item_val_type.BOOL_; END_STRUCT END_TYPE TYPE LOG_DATA_INT extends LOG_DATA_BASE : STRUCT val_type : log_item_val_type := log_item_val_type.INT_; END_STRUCT END_TYPE etc. for LOG_DATA_REAL and ..STRING. The system will not allow me to "re-define" "val_type" however. Instead I must do the work-around of defining four different types with all fields individually defined. The benefit if I could extend the base item would be that Im (more) sure the structures are identical. In usage I can call in a specific type rather use the base type and assign which type. Usage by pointer/ref to log_data_base would also be easier.. (* Usage: *) log_data : log_data_int := (name, value etc.) (* Instead of: *) log_data : log_data_base := (name, value, val_type).. Is this possible to achieve in some way that I have missed?
Last updated: 2025-03-05

Post by struccc on The future and proper use of CAA.BOLT, CAA.SEMA,.. CODESYS Forge talk (Post)
Dear All, Dear CODESYS, I'm curiously following CODESYS transitioning away from the CAA libraries, and I'm mostly in favor of these major changes. Naturally, I'd like to align my current (not end-user) developments accordingly. I'm tracking , reading release notes, ... And want to figure out the future :) Is it possible to hear / read more about the reasons, objectives and scope of these changes? One important element is CAA Types - CAA Types Extern. What is the plan with that? What's the future of CAA.SEMA, CAA.BOLT ? I have never used them (always relied on SysLib*), but they are tempting... Would be useful to have a platform independent "Macro" for this functionality... Is there something in existing or planned ? Are they suitable to be used in low level libraries... For Example IO-Drivers, Components, "to-become system libraries"? CAA.TaskLock, CAA.TaskUnlock ? Well, they don't claim platform independency, so I can't rely on those.... Any up-to-date advise, standard, pattern to follow in new libraries for task and resource locking? Practical set of conditional defines to be used? If this information is not publicly available, can you please send a private message about the proper way to achieve this? I have support agreement, just couldn't get trough with these questions... P.
Last updated: 2025-03-14

Post by pernockham on Persistence Manager: Config File not found? CODESYS Forge talk (Post)
Back in november I paused this, but wanted to reattempt using the persistent manager, the behavior is still the same. Most "login attempts" s are stopped with the message "One or more errors occurred" but I have no idea what that error might be. The only clue is this message is presented while the lower left status box says "Generating code...: relocation pou". For clarification. Build/Generate code is successful, no errors. Error appears when I try to download/login (physical or simulation) to a device. I did manage to login (in simulation mode) at one point, but then the error message "PersistenceChannel: Config file not found!". And no persistence files were created. I have done device-tree/reset-orgin also clean/clean all etc. Removed/re-inserted persistance manager. Behaviour is just the same. Removing Persistence Manage and everything is working OK. Is there possibly more info somewhere about the "One or more errors occured"-message?
Last updated: 2025-03-20

Post by latassan on RaspberryPi 5 gateway problem CODESYS Forge talk (Post)
Hello, I'm trying to use a raspberryPi 5 as a PLC. I fixed its IP address, I can ping it. I've also installed the CODESYS Control for Raspberry Pi 64 SL runtime on it. So I've created a gateway (IP address of the Raspberry, TCP port 1217). I see the green dot next to this gateway. When I do a network scan, I can see my raspberry (see photo). When I try to connect to it, I have to define an administrator profile, which I do. On validation, I see a message: No device is responding to the scan request. I've checked that port 1217 is listening on the raspberry, I've uninstalled the runtime then installed it again, but I can't connect. Also, when I try to configure the user groups before connecting, I see that Offline mode is not supported by the device, even though I'm connected to it in the Deploy Control SL tab. When I try to refresh, I see: Gateway not configured properly. How can I connect to my Raspberry? Have I defined my gateway incorrectly?
Last updated: 2025-06-12

Post by pouyavakili on Execute Codesys Tests with python CODESYS Forge talk (Post)
❓ Issue: TestManager Not Available in Python Script (AttributeError) 🙏 Question: Why does project.get_testmanager() not work in scripting, even though Test Manager is installed and licensed, and the script runs in GUI mode? Is there a way to ensure the Test Manager interface is loaded or accessible from the scripting environment? 🧠 Summary: I'm trying to automate test execution using the CODESYS scripting engine (Python) via a script that opens a project, builds the application, and runs tests from a TestRepository.xml. Although the Test Manager works manually in the IDE, it fails when accessed via script with the following error: AttributeError: 'ScriptObject' object has no attribute 'testmanager' 🧪 Test Setup: CODESYS version: 3.5.21.10 Test Manager: Installed and licensed (works in the IDE manually) Project: Contains a test repository, which can be executed via the GUI Script execution method: powershell Start-Process -FilePath "C:\Program Files\CODESYS 3.5.21.10\CODESYS\Common\CODESYS.exe" ` -ArgumentList @( '--profile="CODESYS V3.5 SP21 Patch 1"', '--runscript="C:\Scripts\run_tests.py"' ) -Wait 📜 Script Summary: python project = projects.open(project_path) application = project.active_application application.build() This fails: testmanager = project.get_testmanager() ❗ Problem: Calling project.get_testmanager() or application.testmanager throws an AttributeError, even though the same project and test repository work in the GUI.
Last updated: 2025-07-23

Post by leandroct on Creating Boot Application not working CODESYS Forge talk (Post)
I have a Control Win V3.5 SP20 (64-bit) application, and until now, I open the program (with a password) and download it. However, I need to give the client the option to install the program on the Controller, without them having to open it and access the code. So, I followed these steps: 1 – In the Online => Create Boot Application menu, I saved the generated files in a directory: Application.app Application.crc PlcLogic\visu\ directory with several files 2 – In the SysTray, I ran the PLC, and it created a directory. In the root of this directory (C:\ProgramData\CODESYS\CODESYSControlWinV3x64\E84889DB), I pasted Application.app and Application.crc. Since it created a \visu directory, I pasted the PlcLogic\visu\ files generated in Create Boot Application into it. 3 - In the general Codesys directory (C:\ProgramData\CODESYS\CODESYSControlWinV3x64), I edited CodesysControl.cfg, adding: [CmpLog] Application.1=Application 4 - When running the PLC, nothing happens and the TargetVisu screen does not open. What I'm doing wrong?
Last updated: 2025-09-03