Post by lukebouchard on NVL generating ADwin packets instead of UDP?
CODESYS Forge
talk
(Post)
Using Codesys 3.5 SP11 32bit to program a pair of IFM CR711S controllers. They each have an NVL sender and are set up to receive each others messages. One is transmitting properly but not receiving, the other is receiving the first's messages just fine. When I look at the traffic in wireshark, I can see the one transmitting properly as UDP packets on the subnet and port I had specified. The Second is transmitting on the right subnet and port, but is sending 'ADwin Config' packets. Has anyone run into anything simmilar? From some reading on ADwin from google, nothing is enlightening. Both are set up in the same way, have their own ports and List Identifiers. I have deleted the NVL files and regenerated them, cycled power, and even deleted and remade the NVL's so many times.
Last updated: 2024-08-24
Post by hfelek on TargetVisu for Linux Package on runtime 4.12.0.0 install error due to Qt dependencies.
CODESYS Forge
talk
(Post)
Hi, I am trying to make my runtime support TargetViso on 4.12.0.0 runtime. First when I tried to install package I got error due to missing libraries that are generated through qt-base. After compiling and installing related qt lib when I tried to install the package, I didnt get lib dependencies error but I got another error: [ERROR] The installed QT Version does not meet the minimum required version 6.4.2. Please install version 6.4.2 or higher and try again. When I check Qt version I get the following response QMake version 3.1 Using Qt version 6.5.0 in /usr/local/qt6/lib. I tried with Qt version 6.9.0 but that didn't help. Any idea on what coudl be the reason. When I looked for codesys related processes the related libraries were included within environment.
Last updated: 2024-08-27
Post by yannickasselin on codesys VLAN tagging
CODESYS Forge
talk
(Post)
Hi, I am looking for exactly the same thing. I would think that using a layer 2/3 managed switch should work but I am not convinced. I would like to test it in order to see if it would be possible to run many Codesys Docker instances on a server and run only 1 ethernet cable from the server to a managed switch closer to the machines beeing controlled instead of having to run multiple long ethernet cables. I was going to buy a managed switch in order to test it but I want to first make sure it is possible and I want to figure out exactly what kind of switch I would need. Is this even possible? I think this is a feature that would be very useful paired with "Codesys Virtual Control SL". Thank you
Last updated: 2024-09-07
Post by dkugler on Webvisu client connection monitoring
CODESYS Forge
talk
(Post)
you can give this code snippet a try. It's extracted and simplyfied from my code: Install VisuElemBase lib if not installed yet. Execute in visu task: VAR pClientData : ARRAY [-1..100] OF POINTER TO VisuElemBase.VisuStructClientData; END_VAR VisuElemBase.g_ClientManager.BeginIteration(); pClientData := VisuElemBase.g_ClientManager.GetNextClient(); WHILE pClientData <> 0 DO pClientData[pClientData^.GlobalData.GlobalClientID] := pClientData; END_WHILE You have to make shure every no longer updated pointers in the array have to be deleted and no longer used by your code! Usage of this pointer access at your own risk :-) Works with SP16. From SP17 and newer there will be warnigs etc. using this solution as I remember. It will be great, if Codesys publishes a example or give a hint how to accesse this client values with the VisuUtil lib or other future-proof way!
Last updated: 2024-09-09
Post by shabroz-gill on Exception when OPCUA datasource disconnects from Server
CODESYS Forge
talk
(Post)
If i loose the network and the opcua data source suddenly looses connection with the server, i get an exception and my application stops working. I am using the latest version of the communication add v4.5.2.0 Is this a known issue? This makes the datasource unusable because it is inevitable that we will loose connectivity at some point, and the datasource crashing everything due to that seems to be a deal breaker. I can provide more details is someone from codesys is reading this. You can recreate is by just shutting off the Opc server after the codesys data source is connected and reading data from it. The codesys app does not crash everytime and sometimes it is able to reconnect without crashing, so you may have to try this a few times to see the exception. Best regards
Last updated: 2024-09-16
Post by jinlee on Reading Camera Feed in Codesys v3.5 webvisu web element browser
CODESYS Forge
talk
(Post)
Hi guys, I have been trying to use web browser element in the visualisation to connect with my IP camera. From the past few weeks, I have not been successful of doing it. I thought it would be very easy to just connect to the ip address, but apparantly it is not. I am using WAGO PLC PFC200 and my PC as a webvisu. or else can you guys please advice me on which kind of camera should I use as a CCTV system in my project instead of IP Camera. Ideally, I want multiple web browser elements to browse my IP Cameras in one frame. Kind regards, Jin.
Last updated: 2024-09-16
Post by opineiro on Stack overflow with really simple function
CODESYS Forge
talk
(Post)
Hi, I have an issue with a function which sends a message through API Rest. I'm using a function from httpCLient library. I have tested this function inside a program and it works fine. But when I want to use it inside a function (so I can call it simultaneously from 2 different points on the main program) it gives a stack overflow error. In detail it says: "C0297 Stack Overflow on Main Task. Stack sizes... Call hierarchy:" I have simplified as much as I can the function, but I'm hitting a wall with this. Anybody has an idea of what's wrong? Thanks!
Last updated: 2024-09-16
Post by jinlee on Reading Camera Feed in Codesys v3.5 webvisu web element browser
CODESYS Forge
talk
(Post)
Hi guys, I have been trying to use web browser element in the visualisation to connect with my IP camera. From the past few weeks, I have not been successful of doing it. I thought it would be very easy to just connect to the ip address, but apparantly it is not. I am using WAGO PLC PFC200 and my PC as a webvisu. or else can you guys please advice me on which kind of camera should I use as a CCTV system in my project instead of IP Camera. Ideally, I want multiple web browser elements to browse my IP Cameras in one frame. Kind regards, Jin.
Last updated: 2024-09-16
Post by jinlee on Reading Camera Feed in Codesys v3.5 webvisu web element browser
CODESYS Forge
talk
(Post)
Hi guys, I have been trying to use web browser element in the visualisation to connect with my IP camera. From the past few weeks, I have not been successful of doing it. I thought it would be very easy to just connect to the ip address, but apparantly it is not. I am using WAGO PLC PFC200 and my PC as a webvisu. or else can you guys please advice me on which kind of camera should I use as a CCTV system in my project instead of IP Camera. Ideally, I want multiple web browser elements to browse my IP Cameras in one frame. Kind regards, Jin.
Last updated: 2024-09-16
Post by timvh on Clarifications regarding the appropriate runtime system to use
CODESYS Forge
talk
(Post)
If you are not using any specific Raspberry Pi functionality, then probably the "universal" Control Linux ARM SL is the approriate runtime to run on the Pi. For the license it doesn't matter which runtime version you choose, because this is not hardware based anymore, but application based. Best is to use the latest version of CODESYS. To determine which license you need, double click on your device, go to the tab License metrics.... Generate the code for your application and see which license you need based on the metrics of your application.
Last updated: 2024-09-24
Post by struccc on HTML5 Controls - string(>80) values
CODESYS Forge
talk
(Post)
Dear all, does anyone have experience with HTML5 controls recently? CODESYS 3.5.20.30 / Visualization 4.6.0.0 I'd like to create a simple lightweight text editor, with proper multiline handling, cut & paste, scrolling, etc. And it seems to work fine, just have problems with strings longer than 80 bytes.... Declaring a variable sText1 : STRING(8000) and referencing it in the HTML5 Controls corresponding value property works perfectly one way: the code receive the data as a string (See log1)... (Note TypeID 1000...) Also sending back the data (seems to work (See log2) except it doesn't change the value of the bound variable. Probably the issue is with using SendSimpleValue method... Naturally, I could do a workaround, but maybe there is a more standard way to implement this... Please let me know if you have any suggestions.
Last updated: 2024-10-23
Post by gediminas on Datasource OPC UA client system failure
CODESYS Forge
talk
(Post)
I am using CODESYS v3.5 SP20 Patch 3 / Control for BeagleboneBlack SL v4.13 and after some time the OPC UA Server crashes. However, Runtime still works without any issues. The events leading up to the OPC server crash are the most suspicious: 1) Mutex deadlock detected - owner thread died, and 2) Runtime received SIGABRT. And it seems very similar with this topic except used versions - issues should be fixed with previous SP's. I can't seem to find any information about these events. Need some pointers in the right direction on how I can fix this problem.
Last updated: 2024-10-25
Post by srouse on Adding a Softmotion License to a Weintek HMI
CODESYS Forge
talk
(Post)
I am trying to add a Softmotion license to my Weintek HMI. The HMI is already licensed for Codesys and I have already purchased a Softmotion license as well. When using the License Manager I get an error saying the licensing info is not available. I am fairly new to working with Codesys so I am at a bit of a loss and there seems very little information online about troubleshooting this specific issue. I have attached the error message below. If there are any ideas of how to troubleshoot this better I would be happy to hear them.
Last updated: 2025-01-09
Post by askic on Library Documentation Export Error
CODESYS Forge
talk
(Post)
Hello, I have encountered a very strange and non descriptive error when creating libraries. Basically, when user just create a new CODESYS library, and then just add Text List, save build with no errors and then try to save as compiled library, the following error would be generated: "The library documentation export error" and nothing more, just like shown in the attachment. Of course I have installed package CODESYS Library Documentation Support v 4.6.0.0 I'm Using Codesys 3.5.20 Patch 2 Does anybody have any suggestion about the cause of this error or any advice on how to troubleshoot further?
Last updated: 2025-02-15
Post by peterkcontrols on TargetVisu started in windowed or not full screen
CODESYS Forge
talk
(Post)
Hello, I am using Codesys on an industrial pc with a single monitor. I would also like to have a separate vision software running on the PC and would like to display it half screen. When I run the soft PLC the my visualization screen appears full screen, I would like to be able to set the size of the visualization screen so I can display other software on the monitor. Is it possible to set the width/height of the targetVisu? Anyone try something similar? I would like to avoid having to put it on a Virtual Machine. Thank you
Last updated: 2025-02-26
Post by peterkcontrols on Copying 2 byte word to output
CODESYS Forge
talk
(Post)
Hello. I am using codesys 3.5. I would like to know if it is possible to set a variable to an output without declaring in. I have defined a STRUCT and within this struct I have a Struct for inputs called I and a struct for outputs called O. I have declared a variable of the type of this Struct, I would like to set or alias the value in this variable to an input/output value of an IO block that has a module on the ethernet tree. Is it possible to copy the contents of %IW0 -> STRUCT.I ? The size of both of these is 2 bytes. I understand that I can declare a variable with the input like Input01 AT %IX0.0 : BOOL; However how can I make STRUCT.I.D00 AT %IX0.0? Is this possible? Thanks
Last updated: 2025-03-03
Post by clarenced on Multiple applications on one device sharing variables.
CODESYS Forge
talk
(Post)
I got this working using OPC UA. In the logic application I just added a Symbol Configuration. In the HMI application I added a Data Sources Manager and OPC UA Data Source. The one thing I don't like is the way the tags end up being named in the HMI application. In the logic application I have a program named PLC_PRG. It has a variable named testDINT. In the logic application the name I get for this variable is DeviceSet.CODESYS_Control_Win_V3_x64.Resources.Logic.Programs.PLC_PRG.testDINT. This is very long and looks like it could change if I used this on a different device type. Any ideas how I could get this name shortened down to just PLC_PRG.testDINT like it is on the Logic application?
Last updated: 2025-03-06
Post by clarenced on Multiple applications on one device sharing variables.
CODESYS Forge
talk
(Post)
I got this working using OPC UA. In the logic application I just added a Symbol Configuration. In the HMI application I added a Data Sources Manager and OPC UA Data Source. The one thing I don't like is the way the tags end up being named in the HMI application. In the logic application I have a program named PLC_PRG. It has a variable named testDINT. In the HMI application the name I get for this variable is DeviceSet.CODESYS_Control_Win_V3_x64.Resources.Logic.Programs.PLC_PRG.testDINT. This is very long and looks like it could change if I used this on a different device type. Any ideas how I could get this name shortened down to just PLC_PRG.testDINT like it is on the Logic application?
Last updated: 2025-03-06
Post by trusty-squire on AXIS Rollover
CODESYS Forge
talk
(Post)
If you mean you want to shift the Origin or Zero position of your axis, you can try MC_SetPosition and set the position to 0 (if you want to take the current active position and make it the new 0. Adjust this number accordingly if/as needed). This means the servo drive keeps it's current origin position, and Codesys applies an offset to the servo drive position in the logic. You can also use the homing function of your servo drive using MC_Home and have your drive configured to set the current position as origin when it receives a homing command.
Last updated: 2025-03-11
Post by mehakfatima on Need Help Configuring Energy Analyzers via Modbus TCP & RTU (RS-485) in CODESYS 3.5
CODESYS Forge
talk
(Post)
Hello everyone, I am currently working on reading data from energy analyzers using Modbus TCP and RTU (RS-485). In my previous software, I used the following method to add slave devices (i have attached the image) and configure registers: Add the Modbus slave device. Configure the communication parameters (baud rate, parity, etc.). Define the registers and their addresses for data retrieval. Now, I am trying to achieve the same in CODESYS 3.5, but I am not sure how to configure the Modbus master, add slave devices, and set up the registers properly. If anyone has experience with Modbus TCP/RTU setup in CODESYS 3.5, I would really appreciate your guidance! A step-by-step explanation or any references/tutorials would be extremely helpful.
Last updated: 2025-03-13
Post by milosfejgl on Codesys Licenses - How to reload them after updating the Raspberry Pi OS
CODESYS Forge
talk
(Post)
We use several control units running on Raspberry Pi, programmed using Codesys software, with multiple licenses stored as soft containers. We are planning to update the SD card image of the Raspberry Pi to a newer OS version. However, we are concerned that this process might result in the loss of our soft container licenses. Is there a way to temporarily deactivate the license so that it can be reactivated on the updated system? Alternatively, what would be the best method to preserve the licenses during the update? Thank you in advance for any responses!
Last updated: 2025-03-13
Post by r-c-r on SM3RaspiStepper 0.0.0.6 issue
CODESYS Forge
talk
(Post)
Hello, I noticed that version 0.0.0.6 is now available, so I tested it using CODESYS V3.5 SP19 Patch 7 and SoftMotion 4.17.0.0. While the project compiles and downloads without issues, I encountered a problem with the 'Enable: GPIO pin number that is set when the axis is enabled (with MC_Power) (0: not used)' functionality β it no longer works (HIGH level not present at the output pin). I observed the same behavior with version 0.0.0.5, whereas version 0.0.0.4 functions correctly. Could you help me identify what might be causing this issue or suggest how to resolve it? Thanks.
Last updated: 2025-03-19
Post by beginner on ERROR: Demo mode for SoftMotion Basic expired. Feature stopped!
CODESYS Forge
talk
(Post)
Hello. Please help me. Sometimes SoftMotion starts in demo mode and stops working after 2 hours. When I check with the license manager, it is recognized normally. I checked the log. After changing online or logging in with a download, the message "**** ERROR: Demo mode for SoftMotion Basic started. Will expire and stop!" was left. Even if you change online or log in with a download, this phenomenon may not occur. Please tell me how to solve this problem. Thank you in advance. Codesys Ver 3.5.20.0 SM3 Basic SoftMotion Ver 4.16.0.0 β»This text was translated using a translator.
Last updated: 2025-03-25
Post by agentcousto on [Bug report] Issue with Importing XML Files Containing "POINTER TO" Variables in Codesys Platform Plugins Versions 2.7 and 2.8
CODESYS Forge
talk
(Post)
Hello, I have developed a Python script that I run to import XML files into my project. For this, I use the Python function import_xml(). Everything was working fine when I was using Codesys platform plugins version 2.6.1.2320, but since I upgraded to versions 2.7 and even 2.8, some files are no longer imported correctly. After some research, I identified that all the files containing variables of the type "POINTER TO" are affected. I have attached a screenshot of the error I am encountering. Do you know about this bug? Do you plan to fix it?
Last updated: 2025-03-26
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.