Post by gatto on Two licenses have to be installed forgot to enable one license CODESYS Forge talk (Post)
Hi. What type of PLC do you have? What activation method do you use? What license ticket did you purchase and want to activate? Can you describe the process you followed step by step?
Last updated: 2026-02-02

Post by nickpoon on SysProcessCreate stopped working after SP21? CODESYS Forge talk (Post)
I'm going through the process of updating the CODESYS Project a machine to 3.5 SP21 (old version was 3.5 SP20). One function that stopped working when upgrading was SysProcessCreate. I need to run a .exe file that is located in C:\Program Files\MQTTStream. Some initial searching suggested that there are new security rules that prevent the SoftPLC from reading/writing files to outside of its Device folder (located here - C:\Windows\System32\config\systemprofile\AppData\Roaming\CODESYS\CODESYSControlWinV3x64\24FD6770) Relocating files helped fix my JSON file reader/writer functions (which were failing previously), but not the case for SysProcessCreate. I've even attempted to just run window's cmd.exe and with: pszCommandLine = 'cd /d C:\Windows\System32\config\systemprofile\AppData\Roaming\CODESYS\CODESYSControlWinV3x64\24FD6770\PlcLogic\MQTTStream & sift-proxy.exe --grpc_uri="https://grpc-api.siftstack.com" --api_key="xxxxxxxxxxxxxxxxxxx" mqtt-client --broker_ip=10.0.10.101 --broker_port=1883 --config_file="mqtt_telemetry_config.json" --username Plantd --password 1234 --stream_metrics --storage_path="sift-proxy-logs"' I have not been able to find a lot of documentation on this, and I suspect the new update may have created a bug for SysProcessCreate. Any help would be greatly appreciated
Last updated: 2026-02-02

Post by arpat on Error, visualisation property handling, VISU_USEPROPERTYINFO CODESYS Forge talk (Post)
For me going to Project -> Project Settings -> Visualisation -> check "Visible" and then check both "Activate property handling ..." and "Activate implicit checks ..." solved the problem.
Last updated: 2026-02-03

Post by jslarbaletier on Unable to compare projects containing alarm manager 4.5.0.0 CODESYS Forge talk (Post)
Hi! I had the same issue and finally found a solution. Alarm Configuration was located in a “Visualisations” folder. I moved Alarm Configuration directly under “Application”, and the issue was resolved.
Last updated: 2026-02-05

Seeking a Code-Based Solution for EtherCAT Slave Dropout or Master Errors in Production (Beyond Software Hot Reset) CODESYS Forge talk (Thread)
Seeking a Code-Based Solution for EtherCAT Slave Dropout or Master Errors in Production (Beyond Software Hot Reset)
Last updated: 2026-02-14

Post by altin on No source code available for this object CODESYS Forge talk (Post)
Hello, I get same error message but pointing at different library. The error appears when im trying to scroll an AlarmTable on a thouch screen (ifm CR1204). Anyone knows what causing this and how to procceed? Many thanks in advance,
Last updated: 2026-02-16

Post by eschwellinger on Unable to deploy "Control for Linux SL 4.18.0.0" CODESYS Forge talk (Post)
Hi could you check if this really exists in 4.19.0.0 deploy tool? In your case architecture is missing- see my configuration
Last updated: 2026-02-17

Post by akneer on HMI über Webbrowser CODESYS Forge talk (Post)
Beispiel: IF bShutdownPC THEN bShutdownPC := FALSE; // LINUX SysProcess_Implementation.SysProcessExecuteCommand( pszComand:='shutdown -h 0', pResult := ADR(udiError)); // WINDOWS SysProcess_Implementation.SysProcessExecuteCommand( pszComand:='shutdown.exe -s -t 05', pResult := ADR(udiError)); END_IF
Last updated: 2026-03-04

Post by fpawlak on How to register own component - CMAddComponent() or CMAddComponent2() CODESYS Forge talk (Post)
Hi, so really oneone has no idea which way is correct one? Or maybe both are okey if they work for me?
Last updated: 2026-03-13

Post by pernockham on Gateway in China - "Gateway not connected" CODESYS Forge talk (Post)
Finally sorted (unit in China). The problem was related to dns-setting of the gateway/host. Connection (also inside china) tested/works.
Last updated: 2026-03-18

Post by thomasrek31 on Textfield display problem CODESYS Forge talk (Post)
Hello, have you found a solution? It seems I have the same problem as you. I can't remove the overlay, otherwise certain functions stop working.
Last updated: 2026-03-23

Post by thomasrek31 on Textfield display problem CODESYS Forge talk (Post)
Hello, have you found a solution? It seems I have the same problem as you. I can't remove the overlay, otherwise certain functions stop working
Last updated: 2026-03-23

Post by ulvis on CAA 3.5.16 TLS configuration - certificate CODESYS Forge talk (Post)
Hi, did yo have any luck with this? I am facing the same challenge. Using a WinCTRLx64 but I get AccessViolation error in my CmpTlsCreateContext() call.
Last updated: 2026-03-23

Post by lukasz on Unresolved reference when trying to upload to Codesys Runtime V3 CODESYS Forge talk (Post)
Hello! I'm working with Codesys SP21 Patch 4. The project builds without any errors. When trying to upload my project to Codesys Runtime V3 x64 I get a lot of Unresolved Reference errors, all with FU- at the start and then -CLOSELAYER2, -GETBUSINFO, -GETFRAME etc. I also get a error pop-up that I should 'update device' in the project but it's not specified to which version or anything useful really.There's also not much to choose from. When I check Runtime version in the systray I get 3.5.21.40 and it's the same as I have set up in the project as the device. All information I get is that it should be clear from the errors but no useful information is provided in the errors. Do I need to install some library? I checked other posts and for different reference error and this was the answer. Thanks in advance!
Last updated: 2026-03-25

Post by nulltrace on How change Unity-ID in TCP Modbus Slave CODESYS Forge talk (Post)
Hey Husarz, thanks for your Message, now i understand your Problem, also able to reproduce that. Pls. give me a Short Time to Check some stuff on this, i'll come back to this Topic with news ASAP. Greetings
Last updated: 2026-04-03

Post by struland on Sysfile Konfiguration CODESYS Forge talk (Post)
Bei mir half: [SysFile] IecFilePath=/mnt/sdcard Allerdings ist es kein Raspi. Den Ordner, der gelesen werden soll mal auf korrekte Zugriffsrechte prüfen. Im Falle das SELinux aktiv ist mit ls -lZ, ansonsten ls -al
Last updated: 2026-04-13

Post by struland on Sysfile Konfiguration CODESYS Forge talk (Post)
Bei mir half: [SysFile] IecFilePath=/mnt/sdcard Allerdings ist es kein Raspi. Den Ordner, der gelesen werden soll mal auf korrekte Zugriffsrechte prüfen. Im Falle das SELinux aktiv ist mit ls -lZ, ansonsten ls -al
Last updated: 2026-04-13

Post by nulltrace on How change Unity-ID in TCP Modbus Slave CODESYS Forge talk (Post)
Hey, I also waiting for feedback from Mr. Schwellinger @eschwellinger, please send me an answer, i would appreciate it. The clue is, i know the solution, but have to check if it's allowed to share.
Last updated: 2026-04-14

Post by husarz17 on How change Unity-ID in TCP Modbus Slave CODESYS Forge talk (Post)
Good to know there's a solution to this problem. I hope you'll be able to share it with me. I can't wait to hear about it.
Last updated: 2026-04-20

Post by malie on Issue with library updates CODESYS Forge talk (Post)
Hello, i got the same problem, but on my site it started with version 3.5.21, with version 3.5.19.7 it worked like a charm. How get the old behavior back? Or how to reload the librarys in an open project/library manually?
Last updated: 2026-04-24

Post by reinier-geers on Network variable stops sending CODESYS Forge talk (Post)
What version. 20.5 ? ive got also problems wiyth that version. Online change, it hangs itself after one hour. Then one project can problems. Ive change display with 21.0 . At home i turned on the 20.5 display. After 1 hour i goes to stop.
Last updated: 2026-05-06

Post by alex-n on Problem with keeping up the distance between two axes CODESYS Forge talk (Post)
We use Inovance AC802 as PLC, IS810N Drive, library 4.10, connection via Ethercat and no any suprise at work.
Last updated: 2026-06-02

Whether You’re New to Nursing or a Seasoned Pro, Grasping the Basics of NURS FPX 4055 Assessment 1 Offers Many Benefits CODESYS Forge talk (Thread)
Whether You’re New to Nursing or a Seasoned Pro, Grasping the Basics of NURS FPX 4055 Assessment 1 Offers Many Benefits
Last updated: 2026-06-13

Post by eschwellinger on Linux ARM64 Deploy Fail - Index out of range CODESYS Forge talk (Post)
Which Deploy Tool version is installed? the ssh login does work? If yes could we get a screenshot of the device information see my example:
Last updated: 2026-07-01

Post by arj3090 on Linux ARM64 Deploy Fail - Index out of range CODESYS Forge talk (Post)
I used Tools->Deploy Control SL in the IDE that I downloaded yesterday. So I assume it is the latest version. I did a manual install using SSH and it works.