naja die compiled library hast du ja - du hast halt eine exception - und dann wirst du gefragt ob du das ganze Debuggen willst. Die offene Bibliothek wirst du nicht bekommen - daher würde ich so vorgehen: Dein Projekt hier mal anhängen so das man mal draufschauen was du genau aufrufst und wie.
Last updated: 2024-10-18

Post by lbartik on MPC predictive control CODESYS Forge talk (Post)
Would this work? https://www.mathworks.com/hardware-support/codesys.html I'm also interested in real-world MPC and have no idea where to start. There is an exciting Python library that is also beyond my grasp: https://www.do-mpc.com/en/latest/index.html Step 1, get PhD(s). Step 2, get job in aerospace/robotics. Step 3, return 15 years later to share this knowledge?
Last updated: 2024-10-19

Post by davidbo on Modbus: Is there a way to get the channel index from the channel name? CODESYS Forge talk (Post)
When I use the FUNCTION_BLOCK ModbusChannel I have to sepcify the integer iChannelIndex It can easily go wrong if one has many channels. It would be better if one could use the name. Is that possible? Attached a snippet of the channel name and the channel index to the left.
Last updated: 2024-10-21

Post by spoun on Problem with edge gateway config mode CODESYS Forge talk (Post)
I installed patch 3 now and i get a new message, although i located and modified the files in system32 and sysWOW64 still doesn't work. One thing i noticed is thta in system32 folder CODESYSGatewayV3 now i have two different XXXXXXXX files with the latest being created today at the time of installation
Last updated: 2024-10-21

Post by phoward131 on Alarm Table Filtering CODESYS Forge talk (Post)
I actually just found the solution maybe. If anyone else is running into this, go to your Project Settings > Visualization > Advanced (check 'Visible' to see advanced settings) > UNCHECK 'Activate property handling in all element properties.' I am not sure what else unchecking this might affect but it seems to allow the alarm table to be filtered as expected.
Last updated: 2024-10-28

Post by phoward131 on Alarm filtering latch variables CODESYS Forge talk (Post)
I am having the exact same issue and was wondering if you ever found the problem? The sample program does exactly what it's supposed to with filtering but when I implement it the exact same way in my program, the alarm list just goes blank when I attempt to apply a filter.
Last updated: 2024-10-28

Post by phoward131 on Alarm filtering latch variables CODESYS Forge talk (Post)
I actually just found the solution maybe. If anyone else is running into this, go to your Project Settings > Visualization > Advanced (check 'Visible' to see advanced settings) > UNCHECK 'Activate property handling in all element properties.' I am not sure what else unchecking this might affect but it seems to allow the alarm table to be filtered as expected.
Last updated: 2024-10-28

Post by yannickasselin on MQTT QoS 1 & 2 CODESYS Forge talk (Post)
Hello, After some more tests, here is what I found out. It seems we have to increase the uiKeepAlive and tPingInterval parameters. If I increase the uiKeepAlive value to 60s and the tPingInterval to 30s, then if I disconnect the ethernet cable from Codesys and publish some messages to which Codesys subscribes to and then reconnect within 30s, I will get the messages. If I don't reconnect the cable within 30s (ping interval), the client goes in error with "ACKNOWLEDGE_TIMEOUT". When this happens, it will not automatically reconnect after reconnecting the cable. I have to disable and re-enable the client but I will not get the published messages. I need to do more tests because there are a lot of weird things happening when playing with the ping interval and the keep alive. It is not clear to me what does what. I even ended up not receiving messages anymore, even if I disabled and re-enabled the mqtt client. The client did not give any error. The only way I was able to get messages again was by modifying my client ID. After that, if I try to re-use one of the old client IDs, nothing works (publish, subscribe) and I get a TCP_INIT_ERROR and sometimes a TCP_READ_ERROR. I need more explanation/documentation about these weird behaviors. Maybe it is the way I use it, maybe it is related to the broker (I am using Mosquitto with default parameters). When using a Node-Red client, everything works perfectly. I am trying to achieve the same behavior with Codesys but it seems impossible so far.
Last updated: 2024-10-30

Post by timvh on CAN Open Manager - varible of SYNC CODESYS Forge talk (Post)
You can enable "Sync Producing" in the configuration of the CANopen Manager. Then this manager will send a SYNC message every interval you set. Depending on your PDO configuration, the CAN nodes can send a PDO on every Sync (cyclic-synchronous). If this is not possible, then as alternative you can send a low level CAN message with COB-ID 16#80.
Last updated: 2024-11-05

Post by pixsys on loading delay with the option "check client animations and overlay of native elements" CODESYS Forge talk (Post)
Hi, the option "Support client animations and overlay of native elements" needs a very powerful graphics accelerator in the system. I'm using the Pixsys srl "TC series" HMI with the code "P3" (so a 4+4 cores CPU) that runs very well also with this option active.
Last updated: 2024-11-06

Post by hemuv on Open Numpad with VU.FbOpenDialogExtended CODESYS Forge talk (Post)
Hello Barton, I try to log the changes in Numpad (upon Ok button pressed) that an Element name/Element text variable is changed from so to so. How to get the Element name (or text fields Text Variable) from where the Numpad is called? Numpad is Invoked from Inputconfiguration->onMouseDown->Write a variable. Thanks
Last updated: 2024-11-07

Post by rafaelbrito on The element of type 'VisuFbElemImage' could not be updated. Reason: Index was outside the bounds of the array. CODESYS Forge talk (Post)
When trying to use the Visualization ToolBox, no objects appear and the following error appears. Could you tell me what this error could be? The element of type 'VisuFbElemImage' could not be updated. Reason: Index was outside the bounds of the array. Can anyone tell me what this error is?
Last updated: 2024-12-03

Post by hyys12 on Energie price CODESYS Forge talk (Post)
I am definetly not an expert in this field, but it does seem like you need a propper API key in the URL. Right now you are using the token 'ANWB' in your URL, which the website returns an error, since this is not valid. Somehow you first need a propper API key. I hope that makes sense.
Last updated: 2024-12-06

Post by timvh on Colors look different when logged in and running CODESYS Forge talk (Post)
At the top of the Visualisation Properties View, you can enable the "Advanced" options. This will give you access to more properties than what you currently see. There might be a variable linked to the "advanced" colour property where the fill colour is determined by the value of this variable (dword).
Last updated: 2025-01-09

Post by timvh on Library ENUM text representation in visualization CODESYS Forge talk (Post)
Probably the enum from the library doesn't have text support. In that case you need to add your own TextList to the application. In the rectangle you should use the property "dynamic text" to link this object to the textlist which you have created yourself and then link the text index to your enum variable.
Last updated: 2025-01-09

Post by gseidel on Strange problem with the ‘MC_SetPosition’ function CODESYS Forge talk (Post)
Hi Gustavo, can you reduce the problem to a project that reproduces the issue without the real servo drives? (You could set the servo drives to virtual and strip away as much as possible from the application.) If you can attach a project, we will have a look. Best regards, Georg
Last updated: 2025-01-10

Post by trusty-squire on Help with __SYSTEM.VAR_INFO CODESYS Forge talk (Post)
Not knowing exactly what you want to accomplish, you can try to use VAR_INPUT MyVar: POINTER TO BOOL; END_VAR MyVar contains the address of your referenced variable, and MyVar^ dereferences it allowing you to access the value. If this doesn't meet your needs, could you add more detail on what you are trying to accomplish?
Last updated: 2025-01-26

Post by gatto on Removing a symbol from the IEC Symbols Editor grid CODESYS Forge talk (Post)
Hi, I've never used Communication Manager, but I tried it and I saw that I can drag tags from left to right. If I click on a line on the right, it turns light blue. By pressing the DEL or CANC key (It depends on your keyboard language) I can delete the line
Last updated: 2025-02-12

Post by timvh on TargetVisu started in windowed or not full screen CODESYS Forge talk (Post)
In your soft plc folder, there is a file called targetvisuextern.cfg. Open this with a text editor to change the settings. Remove the semi-colons in front of the lines to enable your custom window settings. WindowType=0 means you will get a moveable window. Save the file and restart the soft PLC to enable these settings.
Last updated: 2025-02-26

Post by fabiodasilveira on PLC Shell commands via ST Code CODESYS Forge talk (Post)
Thank you, Bingo. I have added the instructions below to the CODESYSControl.cfg file, but they haven't changed anything. [SysSocket] Adapter.0.Name="ETH0" Adapter.0.EnableSetIpAndMask=1 Adapter.1.Name="ETH1" Adapter.1.EnableSetIpAndMask=1 Regarding your second suggestion, could you please expand a bit on that?
Last updated: 2025-03-03

Post by cellohorst on File Creation Issue CODESYS Forge talk (Post)
Nope! The file path is $$PlcLogic$$ and NOT $$PLCLogic$$. Otherwise a new folder ('PLCLogic') is created (at least with a linux rt - like raspberry or compute module) with the new file in it if you open the file with eFileMode := FILE.MODE.MRDWR. That is a bad bug that I'll report right after this comment.
Last updated: 2025-03-03

Post by domebruce on Which database to use? CODESYS Forge talk (Post)
We have developed a similar application few years ago with .Net and MS Sql Server. The database has about 30 tables, the more bigger tables have 2 or 3 thousands records. We can have multiple threads accessing at the same time to the DB. To garantie the data integrity we need to manage data locks and transactions. Thanks
Last updated: 2025-03-04

Post by jkopicz on How can you get the active frame index from a frame CODESYS Forge talk (Post)
In my project, I have frames that I would like to read the current active index. I change the frame index using the onclick properties of a button, then change frame index. I need to do some logic based on which frame index is selected. Is there a way to read the current active index of a frame?
Last updated: 2025-03-11

Post by juki01 on HMI über Webbrowser CODESYS Forge talk (Post)
Auf meiner Kendrion SPS läuft eine WebVisu. Über einem touchpanel-IPC mit Win10 greife ich über den Webbrowser auf die SPS zu alles o.k. Nun möchte ich den IPC mit einem Visu-Element runterfahren da der Webbrowser im Kiosk-Mode läuft. Das gelingt mir irgendwie nicht. Kann mir da bitte jemand helfen ? Gruß juki
Last updated: 2025-03-11

Post by peterkcontrols on Making a Visu Element normally invisible and visible if variable is true CODESYS Forge talk (Post)
Hello I would like an element in my visu to be only visible when a certain Variable is true, currently it is only capable of being normally visible and then invisible if a certain variable is true. Is this possible without programming a new variable to be the opposite of my desired control variable? Thanks.