Post by selim on LS ix7nh Servo drive with Codesys
CODESYS Forge
talk
(Post)
Hello Mr./Ms., I do not find the ES driver in codesys. The setup of the project is "Rasberry PI3B>Ls ethercat I/O aps-ec-dt32k> LS ix7nh Servo drive>apmc-fbl04amk LS servo motor". How can i slove this problem. Please provide me a proper solution.
Last updated: 2025-06-02
Post by andrewb on Codesys Visu Update Frame Parameters No Dialog Appears to update
CODESYS Forge
talk
(Post)
I'm also seeing this issue, my instances of the frame will date but not for new parameters that I add to it. Has anyone seen a fix or a way to force the parameter update other than recreating all the frame instances?
Last updated: 2025-06-06
Post by arwie on Use MC_Home without enabling the drive for homing method 35
CODESYS Forge
talk
(Post)
This is a homing routine which is controlled by setting mode of operation and started by setting a bit in the control word. If MC_Home is not usable for this homing method then I need to implement the same functionality. But how?
Last updated: 2025-06-25
Post by felixm on Unable to select VisuDialogs.Numpad in Open Dialog input configuration
CODESYS Forge
talk
(Post)
I'm trying to open the VisuDialogs.Numpad dialog to enter a new temperature setpoint on one of my VISU screens. For some reason, the numpad dialog does not appear as an option in the Open Dialog dropdown in my input configuration. I'm very new to CODESYS, so sorry if this is a simple fix/known item XD.
Last updated: 2025-07-10
Post by timvh on Execute Codesys Tests with python
CODESYS Forge
talk
(Post)
If you want to use the Test Manager, I prefer to start all the tests through the scripts of this manager. So open from there the projects, load it and run it. If you also want to use Python scripts to access CODESYS functionality, while executing a Test Manager script, then also start them from the Test Manager commands.
Last updated: 2025-07-23
Post by davemansell on control loop library IIR filter
CODESYS Forge
talk
(Post)
Hi there i am experimenting with the IIR filter from the control loop library but have been unable to get it to function no matter what inputs I set I get errorID of wrong_configuration (3). Does someone have a working example that they can share. Best regards Dave
Last updated: 2025-07-29
Post by r0udy on Adress problem
CODESYS Forge
talk
(Post)
Hi, I 've just started a new project. Translating SoMachine (SCHNEIDER) to CODESYS 3.5.18//DEMO (EATON XC303) I succeed (I think so) to copy FB, STRUCT,... and I also integrated old library. When I build F11, I have a first problem : - Adress out of rang - Overlay It's strange, usually %ML100 > %MB800 Here ONLINE: %ML100 > %MB100 !! I don't understand why ? And idea ? Thanks
Last updated: 2025-08-06
Post by rajatdas2005 on Codesys Virtual control SL
CODESYS Forge
talk
(Post)
Thanks once again. Right now the codesys virtual control sl docker is using the host ip itself not the docker ip. so the local host edge gateway was able to search the virtual plc. so you are telling me instead of local host edge gateway I should use the edge gateway docker version?
Last updated: 2025-08-08
Post by morecoffee on Control for Raspberry Pi 4.17
CODESYS Forge
talk
(Post)
I am currently having the issue that Codesyscontrol only runs for 10 seconds on my Raspberry Pi 4. I believe the problem is because the MAC address range is of the Raspberry is 88:A2:9E:XX:XX:XX. When will Codesys Control For Raspberry Pi 4.17.0.0 be released to fix this issue?
Last updated: 2025-08-22
Post by nilanjan on I want to show the current recipe name in the visualization screen
CODESYS Forge
talk
(Post)
I am having some trouble showing the current recipe name in visualization i am not using the RecipeManCommands i am using the inbuild visualization feature of Saving and Loading recipes. I need it so the user would have a track on which recipe is being used currently.
Last updated: 2025-08-24
Post by stevens on No option to create "Parameter List" in library
CODESYS Forge
talk
(Post)
I am struggling with this issue right now (again). I have nested structures with configurable array sizes. In the past I ever used parameter list. Very easy way! As of now I cannot find any solution. Ridiculous that they deprecated it without an alternative solution.
Last updated: 2025-08-26
Post by sandro66 on Application-based license Modbus Channels
CODESYS Forge
talk
(Post)
Hi, I imported an old project created with version 3.51.20.50 into the new version 3.51.21.20. I'm using ModbusFB.ClientTCP v4.5.0.0. Strangely, I can no longer download the project due to a licensing issue I didn't have before. The number of Modbus channels has gone from 1 to 54!, and there's no license that would work. Can anyone tell me where I'm going wrong? Thanks Sandro
Last updated: 2025-08-27
Post by timvh on Get Alarm status in Codesys
CODESYS Forge
talk
(Post)
You are right, that you can use the GetState method, but it is not that simple. You first have to get a list of (filtered) alarms from the AlarmManager. You can find an example in Forge how to do this. See https://forge.codesys.com/prj/codesys-example/alarm-manager/home/Home/ Then you can go through this list to get the state of all the (filtered) alarms. See below the code which you could use. This is all based on the example from forge. Create a program: // This example shows how to access alarms via structured text. PROGRAM PLC_PRG VAR xInit : BOOL := TRUE; udiResult : UDINT; fbAlarmFilterCriteriaAll : FB_AlarmFilterCriteriaAll; fbAlarmManagerClient : FB_AlarmManagerClient; itfAlarmManagerClient : IAlarmManagerClient := fbAlarmManagerClient; xAlarm1 : BOOL; xAlarm2 : BOOL; xWarning : BOOL; iNrOfAlarmsInAlarmList : INT; iNrOfActiveAlarmsInAlarmList : INT; paitfAlarm: POINTER TO ARRAY [0..0] OF AlarmManager.IAlarm; iAlarmIndex : INT; eAlarmState: AlarmManager.AlarmState; END_VAR IF xInit THEN xInit := FALSE; fbAlarmManagerClient.itfAlarmFilterCriteria := fbAlarmFilterCriteriaAll; // register alarm client to get updated about alarm status / changes udiResult := AlarmManager.g_AlarmHandler.RegisterClient(itfAlarmManagerClient, 0, 0); END_IF // Polling the number of alarms udiResult := AlarmManager.g_AlarmHandler.GetActiveAlarms(itfAlarmManagerClient, parritfActiveAlarms => paitfAlarm, iCountActiveAlarms => iNrOfAlarmsInAlarmList); iAlarmIndex := 0; iNrOfActiveAlarmsInAlarmList := 0; WHILE iAlarmIndex < iNrOfAlarmsInAlarmList DO eAlarmState := paitfAlarm^[iAlarmIndex].GetState(); IF eAlarmState = AlarmManager.AlarmState.Active OR eAlarmState = AlarmManager.AlarmState.ActiveAcknowledged THEN iNrOfActiveAlarmsInAlarmList := iNrOfActiveAlarmsInAlarmList + 1; END_IF iAlarmIndex := iAlarmIndex + 1; END_WHILE See below some details about the function blocks: One function block should implement the IAlarmFilterCriteria interface. This can be empty except a few methods. FUNCTION_BLOCK FB_AlarmFilterCriteriaAll IMPLEMENTS AlarmManager.IAlarmFilterCriteria Method implementation (others related to interface are empty) METHOD AreAllAlarmClassesSelected : BOOL AreAllAlarmClassesSelected := TRUE; METHOD AreAllAlarmGroupsSelected : BOOL AreAllAlarmGroupsSelected := TRUE; METHOD GetPriorityFrom : USINT GetPriorityFrom := 0; METHOD GetPriorityTo : USINT GetPriorityTo := 255; The other function block should implement IAlarmManagerClient and get a reference to the FB which implements the IAlarmFilterCriteria FUNCTION_BLOCK FB_AlarmManagerClient IMPLEMENTS AlarmManager.IAlarmManagerClient VAR_INPUT itfAlarmFilterCriteria: AlarmManager.IAlarmFilterCriteria; END_VAR Method implementation (others related to the interface are empty) METHOD GetFilterCriteria : AlarmManager.IAlarmFilterCriteria // see VAR_INPUT for filter GetFilterCriteria := itfAlarmFilterCriteria; Off course you have to add the AlarmManager to your application and add some alarms to it.
Last updated: 2025-09-02
Post by timvh on CoDeSys v3.5: creating libraries for both 32-bit and 64-bit controllers
CODESYS Forge
talk
(Post)
Yes, you are right. I think the help is pretty clear: https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_library_development.html It helps you to find errors in the source code of your library if you want to create a library which is using pointers and you want to use your library on 32 and/or 64 bit platforms.
Last updated: 2025-09-02
Post by alexgooi on Execute a .py file with Codesys
CODESYS Forge
talk
(Post)
Hello yann, In the past I have experimented with the execution of Linux commands using Codesys. Maybe this article helps: https://www.linkedin.com/pulse/run-linux-commands-from-codesys-jouke-aalvanger When you are able to execute Linux commands in Codesys, you can run the Python script.
Last updated: 2025-09-03
Post by gunstr on CODESYS control on RPi starts, shortly runs, then exits
CODESYS Forge
talk
(Post)
I now tried to install 4.17.0.0 on a fully clean installations: A brand new RPi 4B Install latest Raspberry Pi OS Lite, Release date 13 May 2025, 64bit run sudo apt update && sudo apt full-upgrade When asked - Select to install the updated version of '/etc/initramfs-tools/initramfs.conf' Install CODESYS Control for Raspberry Pi SL. version 4.17.0.0 Log output: [INFORMATION] Connected successfully! [INFORMATION] Successfully connected to target (192.168.0.197) [WARNING] No supported container engine found on device. You have to install a supported container engine to use Virtual Control. Please contact the Administrator of the device. [WARNING] Error detecting container architecture [INFORMATION] Finished reading device information [ERROR] Error output: /var/lib/dpkg/info/codesyscontrol.postinst: 88: check_legacy_extensionapi_folder: not found [INFORMATION] Standard output: Selecting previously unselected package codesyscontrol. [INFORMATION] Standard output: (Reading database ... 76772 files and directories currently installed.) [INFORMATION] Standard output: Preparing to unpack .../codesyscontrol_raspberry_4.17.0.0_all.deb ... [INFORMATION] Standard output: Unpacking codesyscontrol (4.17.0.0) ... [INFORMATION] Standard output: Setting up codesyscontrol (4.17.0.0) ... [INFORMATION] Standard output: make config rw [INFORMATION] Standard output: set folder permissions [INFORMATION] Standard output: prepare permissions [INFORMATION] Standard output: check legacy extension api folder [INFORMATION] Standard output: create and install daemon [INFORMATION] Standard output: codesyscontrol started [WARNING] Unable to detect Raspberry Pi Architecture. Setting armv6l as default, you can change this through the settings panel. [INFORMATION] Standard output: codesyscontrol stopped [ERROR] Expected exit value of command failed: expected 0, received 1 [WARNING] Error setting the Raspberry Pi Architecture [ERROR] Error installing codesyscontrol If I read the log correctly the control is actually installed but cannot start. I'm running out of ideas how to proceeed now, any suggestions are welcome.
Last updated: 2025-09-03
Post by gseidel on The default ramp type selection in SoftMotion V4.18.0.0 is Quadratic
CODESYS Forge
talk
(Post)
Hi imdatatas, thanks for your feedback. This change was intentional, as the quadratic ramp type has many advantages over the trapez ramptype. Sorry to hear it causes problems in your situation. Can you please shortly explain the nature of the problems? Best regards, Georg
Last updated: 2025-09-08
Post by gseidel on Dynamic target position tracking
CODESYS Forge
talk
(Post)
Hi kporter, a more direct way would be to use SMC_FollowPosition to write the set positions directly to the servo drive. This FB has reacts on changes of the fSetPosition on each call, without a need for a rising edge on Execute. See https://content.helpme-codesys.com/en/libs/SM3_Basic/Current/SM3_Basic/POUs/Movement/Direct/SMC_FollowPosition.html. Best regards, Georg
Last updated: 2025-09-08
Post by snhatton on How to write a for loop in ladder?
CODESYS Forge
talk
(Post)
Hi there, little late to the party, but you could also use the ST block for in-line ST code and implement a for loop as you normally would. ST Block is super handy if you just need a small amount of in-line structured text code without creating a new POU. Hope this helps!
Last updated: 2025-10-06
Post by arjunk on How to correctly create a device descriptor (.devdesc.xml) for a custom Linux ARM64 PLC in CODESYS 3.5.21.20?
CODESYS Forge
talk
(Post)
Hi, Iβm evaluating CODESYS for our devices. If I buy a standard runtime and the Toolkit, can I create a custom device descriptor so users can select my device (instead of just βCODESYS Control for Linux ARM64 SLβ) when starting a new project? Has anyone done this or know if itβs possible? Thanks!
Last updated: 2025-10-07
Post by ph0010421 on TCP/IP client
CODESYS Forge
talk
(Post)
Hello TCIS_Send needs to be longer than 4 bytes because idata is 28 bytes long. There may be other ways, but I would make a UNION with string/array of bytes. Write your STRING into the AsString part then copy the AsBytes part into TCIS_Send (Elements [3] to [30]) then 252 would be in [31] (I've assumed the idata is always the same length)
Last updated: 2023-12-19
Post by preimesbergert on Codesys Control for Raspberry Pi 4.10.0.0 - Raspberry Pi OS > 2023-12-05
CODESYS Forge
talk
(Post)
Same issue here: Raspberry Pi 4 Model B HW 1.5 Regardless of the image (tried 32bit / 64bit version from Raspberry Pi Imager- all the "standard version") and with all tested Codesys Control versions (4.2.0, 4.8.0, 4.10.0) and regardless if single core / multicore / 64 bit variant.
Last updated: 2023-12-21
Post by martinlithlith on Raspberry Pi: List of available drivers / libraries
CODESYS Forge
talk
(Post)
Hi! I'm still on the hunt for drivers for example TCA9548 and a list or somewhere where all devices for raspberry is gathered. as this post is quite old I'm hoping/gussing that there is somewhere where work after 2021 is gathered? Or has the raspberry part if the community slowed down on creating device drivers?
Last updated: 2023-12-31
Post by peter-skokanek on Rpi install runtime licence on SP13
CODESYS Forge
talk
(Post)
Hi, I have an older project which has been running for years. Unfortunately I have to replace current Raspberry. I repplaced it by new rpi 3 with newest 32 bit Raspberry OS. I oredered a new runtime licence. When I try to activate it, the connection to target is interrupted immediatelly after press next button in the last step of instalation.
Last updated: 2024-01-08
Post by spiessli on Softmotion axis to CANopen Maxon IDX drive
CODESYS Forge
talk
(Post)
Just verified the behaviour. Still is the same. It should be attached here. But I also tried the DCF-file with the axis in the lab with the real drive: The MC_Power block never goes out of busy. Had not time to investigate further, though.
Last updated: 2024-01-08
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.