Hello, I have a Raspberry Pi 3 which has a printer connected to his USB port. I have a PiFace Board on the Raspberry. I have a python script file (.py) to print a logo + a text. The script is working because when I execute it from the Raspberry terminal it works. Now, when I push a button on the PiFace I would like to execute the python script file to print. How can I do that ? Many thanks for your help and advices!
Last updated: 2025-08-26

Post by eschwellinger on License problem gateway CODESYS Forge talk (Post)
I just try to help. Anyway it is a big difference if a Store SL runtime or an oem plc and licence is used. These licenses need to be activated on plc side - so you have dependencies to the version (CODESYS and Runtime Version) Did you ever ask Epis out for this situation? They should know which license fit to their device. Even they should know if the device is capable for Softmotion and see the requiremnts in the CODESYS store: Runtime 4.9.0.0 - how should this work with Epis 3.5.16.x? Anyway refund is not a problem.
Last updated: 2024-04-26

Post by umair on Code for reading 4 address to get 1 value of sensor (Ethernet IP) CODESYS Forge talk (Post)
Hi all, I want to ask, how do I write code to read multiple address for Ethernet IP communication protocol? Because this multiple address will produce one reading of a sensor that I am currently using. I want to read the value of the sensor. https://global.discourse-cdn.com/business6/uploads/wago/original/1X/7a79f4ad7ce474b9383b8550356d984defd9f3a0.png The addresses are in Byte. The 4 addresses are 89,90,91,92. Thanks in advance. Best regards, Umair
Last updated: 2024-05-06

Post by pernockham on How to recognize licenses SMALL, MEDIUM, LARGE by CmpCodemeter CODESYS Forge talk (Post)
Solved finally, in short by: listening to eventId = EVT_CmpMgr_LicenseState, make a callback, extract the event-parameter which contains the RUNTIME_LICENSE_STATE. This gives me the license state as LICENSED / LICENSED_LOS / DEMOMODE etc. What Im not certain of at this point is this the aggregation of all three licenses or just the RUNTIME? Ie, what if my CONTROL-license is ok but my Visu-license is to low, will that set LICENSE_LOST, or would I need other listeners to find out if my VISU will shut down?
Last updated: 2026-10-07

Post by pernockham on How to recognize licenses SMALL, MEDIUM, LARGE by CmpCodemeter CODESYS Forge talk (Post)
Third update. I figured that even knowing the level of the license, it will not tell me if its level is enough for the current application. There must be some other way to find this out? I see a component CM write in the Log if starting without license-dongle. "License lost - time left.. " Can I access this CM to check status from inside the application? This function is essential, why is it so hard to find info about implementation?
Last updated: 2026-10-06

Post by kmax365 on ModbusTCP_FunctionCode06 CODESYS Forge talk (Post)
Hey Guys, I am trying to create a ModbusTCP_FunctionCode06 which i will use as a single write register for programming a test code for Power Meter(PQM_1000) I have tried to reserach how to add it it from the libraray manager and have largely been unsuccessful. Does anyone know where I should Look? And by the way, I am i wam using Codesys V3.5 Vs 21 Patch 4 I look forward to something positive. Best, Kmax365.
Last updated: 2026-05-14

Post by kmax365 on ModbusTCP_FunctionCode06 CODESYS Forge talk (Post)
Hey Guys, I am trying to create a ModbusTCP_FunctionCode06 which i will use as a single write register for programming a test code for Power Meter(PQM_1000) I have tried to reserach how to add it it from the libraray manager and have largely been unsuccessful. Does anyone know where I should Look? And by the way, I am i wam using Codesys V3.5 Vs 21 Patch 4 I look forward to something positive. Best, Kmax365.
Last updated: 2026-05-14

Post by dhumphries on codesys installer deletes itself instead of updating CODESYS Forge talk (Post)
I'm using the 64 bit version of the engineering software, but the codesys installer seems to be 32 bit. im trying to use the installer to manage my installations but when I open it with admin privelages it starts an automatic update immediately then deletes itself. I don't know how else to explain this. This isn't a repository problem, or a problem with the engineering software, it is a problem with the installer.
Last updated: 2026-08-11

Post by derpaul on PFC200 Update to 4.9.0.0 - No Connection CODESYS Forge talk (Post)
Hallo Today I decided to perform an Update on my PFC200 but after the Update the Device was not reachable anymore. I tried reseting to factory reset. Software reset and so on, but nothing helps... In my Router I can see it, I cann SSH into the PFC200 but it is not reachable. Then I try to go back to 4.8.0.0 But now I get this error: [INFORMATION] Befehl SSH auf root@192.168.1.17 ausführen: Laufzeitsystem stoppen [FEHLER] Fehlerausgabe: /etc/init.d/codesyscontrol: line 34: /opt/codesys/scripts/init-functions: No such file or directory [INFORMATION] Standardausgabe: /etc/init.d/codesyscontrol: line 34: /opt/codesys/scripts/init-functions: No such file or directory Please help, I can't get this thing working... Regards
Last updated: 2023-09-27

Post by derpaul on PFC200 Update to 4.9.0.0 - No Connection CODESYS Forge talk (Post)
Hallo Today I decided to perform an Update on my PFC200 but after the Update the Device was not reachable anymore. I tried reseting to factory reset. Software reset and so on, but nothing helps... In my Router I can see it, I cann SSH into the PFC200 but it is not reachable. Then I try to go back to 4.8.0.0 But now I get this error: [INFORMATION] Befehl SSH auf root@192.168.1.17 ausführen: Laufzeitsystem stoppen [FEHLER] Fehlerausgabe: /etc/init.d/codesyscontrol: line 34: /opt/codesys/scripts/init-functions: No such file or directory [INFORMATION] Standardausgabe: /etc/init.d/codesyscontrol: line 34: /opt/codesys/scripts/init-functions: No such file or directory Please help, I can't get this thing working... Regards
Last updated: 2023-09-27

Post by vincentger on Raspberry Pi Control SL MC - Restoring License not working anymore! CODESYS Forge talk (Post)
Running into the same problem restoring a Runtime 4.4.0.0 device on a now 4.8.0.0 device.
Last updated: 2023-08-21

Post by megamax on Codesys + BeagleBone PLC +LED control CODESYS Forge talk (Post)
Hello! Did you ever solve this? I'm running into the exact same problem.
Last updated: 2024-08-12

Post by installwhat on raspistepper error after install CODESYS Forge talk (Post)
I'm digging into it and see that sm3_shared is nested in the library manager raspistepper->sm3_drive_poscontrol->sm3_shared but I get errors
Last updated: 2024-04-20

Post by alexgooi on Licensing info not available. CODESYS Forge talk (Post)
Thank you for the response, The empty softcontainer does not become visible unfortunately, but I think I can get that back to working. I think I'm misunderstanding something. You are pointing to the Softcontainer number and the ticket code, I thought that I needed to fill in the virtual control containers serial code is this a misunderstanding? And if this is indeed the case, how is the link between the server (softcontainer) and the Codesys control docker container made? If I have multiple Codesys docker containers running on the same docker server, how is the correct license distributed to the correct Codesys runtime container?
Last updated: 2025-10-02

Post by wbj0t on connect IDE to plc that uses modem ppp CODESYS Forge talk (Post)
Hello everyone! I have an PLC device that uses modem ppp connection to the internet with white IP. Device PPP connection with modem operator established, so I can connect to this device via SSH also within Codesys IDE (check version, info, etc...) BUT, I cant establish connection to this device in the device gateway options for application upload and debugging. How can I do this? Im trying set my device remote IP and port 11740, but, as I understand, it is wrong decision, because the next logic in this connection: local W10 service (Codesys Gateway) listen on 1217, then (some how) this service scanning local networks for seeking any local IP which listening on port 11740, and then connects and writes there. OR IM WRONG?:) W10 tool 'Test-NetConnection' with parameters 'ip -Port 11740' succeeded with True. Need some help, please :)
Last updated: 2024-05-21

Post by mait-tim on Drive communication errors CODESYS Forge talk (Post)
With a machine I'm working with i get a communication error when I'm updating some softstop limits. As soon as I update the code the drives do not want to operate. Using the MC_readStatus I'm receiving errors as soon as i want to start a movement. Using MC_ReadAxisError i see that i receive error 131, no response. With a SMC3_ETC_ReadParameter_CoE i do not recieve any driver errors. Does anyone know how i can figure out what the error is and how to solve it. When i go back to the old software no errors occur. Im working with a legacy machine running a Beijer PLC with some Mitsubishi drives. running on Codesys 3.5 SP10. the runtime version is probably 3.5.3. The drives are all Ethercat Drives (CoE). All using the SM3_drive_ETC libary and the SM3_basic library.
Last updated: 2025-12-22

Post by steven-schalm on Github Actions CI/CD tasks - development topic CODESYS Forge talk (Post)
hello kevinrn, I've been looking for a solution to the CI/CD issue for a long time. Briefly about me... I am 32 and software architect for Codesys V3 and fullstack dev for web (VueJS, NestJS) in a small company in Erfurt (Germany). https://www.rex-at.de/. Through my web part, we already have CI/CD running well via GitLab (YAML-based configuration file (.gitlab-ci.yml), which defines which pipelines and jobs are executed when certain events occur) with everything you know. Stages for npm packages - prepare (GitVersion, npm install or whatever) - build (vite, tsc or whatever) - testing (vitest, jest or whatever) - deploy (npm packages) And similar for monorepo's or backend services (in NestJS) as DockerImages. For Codesys we have been building an OOP framework for years (~50 libraries now), which is currently managed via SVN and a specially written Svn-Watcher (in Python) gets commits and runs and builds everything together and deploys it to an FTP server and network drive. Why do we still have SVN? Because we are unfortunately still tied to the safety integration of Codesys and can therefore only go to SP15 at most with our controller/Eckelmann. But soon there will be an update and there will be no more obstacles to using Git. Hence my questions: 1. the basic idea is to run a local Windows Runner on some machine? 2. install Codesys on the machine where the runner is running? 3. powershell & python scripts are then used to execute builds (compile, build, sign libraries) & deploys? 4. can the Github action also be used in GitLab? ChatGPT has already told me that it's not the same, but it doesn't hurt to ask. Do you have any ideas on this? Greetings :D
Last updated: 2024-08-20

Post by chalk on No source code available CODESYS Forge talk (Post)
Hello, This is my first time using Codesys, I am trying to add EtherNetIP communication to a Raspberry PI. I’ve added the EtherNetIP Adapter configured the network setting and added some modules to the pi but when I download the project it generates the following error: “There is no source code available for the object because it is in the compiled library ‘cip object, 4.5.1.0 (3s – smart software solution gmbh)’. Do you want to browse for the original library in order to display the source code? There are 2 errors in the log which are: SOURCEPOSITION App=[Application] area=3, offset=332760 EXCEPTION [Application] occurred: App=[Application], Task=[ENIPAdapterServiceTask] I can’t for the life of me work out how to get around this. I can’t find the source code anywhere or any information regarding this error. I’m using Codesys V3.5 SP19 Patch 3, the version of the Ethernet adapter is 4.5.1.0 and the version of the modules is 4.1.0.0. Any help on this will be greatly appreciated. Thanks
Last updated: 2024-02-02

Post by damian177 on RPi, Codesys , RS232 CODESYS Forge talk (Post)
Hi, so far I have only used one com port - built-in interface in RPi - RS232 (dev/serial0) as COM1 in Codesys, and my CODESYControl_User.cfg have congiuration like below: [SysCom] Linux.Devicefile=/dev/serial portnum := COM.SysCom.SYS_COMPORT1 Actually I added to my Rpi Hat with 2xRS232 (SPI). - /dev/spidev0.0 and /dev/spidev0.1 How I should change my CODESYControl_User.cfg file to use added porta as COM2 and COM3 in Codesys ?
Last updated: 2023-10-05

Post by sean-barton on FILE_OPERATION_DENIED CODESYS Forge talk (Post)
I have code written since version 3.5.16 to access the USB drive, how can I do that now the file access has been taken away? I have tried adding a sybolic link to the usb drive in the following directories: /var/opt/codesys/PlcLogic/ /var/opt/CODESYS/PlcLogic/ /opt/CODESYS/PlcLogic/ I still recieve a "FILE_OPERATION_DENIED" response when accessing the USB drive.
Last updated: 2023-10-13

Post by fazlinda on AWS IoT core CODESYS CODESYS Forge talk (Post)
Hi, Im having a problem sending a data from my structure text code from codesys to aws. Instead of receiving {state {reported {data: 123}}} It display {state {reported {data: 123}}}\x00 \x00 \x00 \x00 \x00 \x00 \x00 Please help me solve this issues. how to remove \x00 ?
Last updated: 2023-12-06

Post by fazlinda on AWS IoT core CODESYS CODESYS Forge talk (Post)
Hi, Im having a problem sending a data from my structure text code from codesys to aws. Instead of receiving {state {reported {data: 123}}} It display {state {reported {data: 123}}}\x00 \x00 \x00 \x00 \x00 \x00 \x00 Please help me solve this issues. how to remove \x00 ?
Last updated: 2023-12-06

Post by fazlinda on AWS IoT core CODESYS CODESYS Forge talk (Post)
Hi, Im having a problem sending a data from my structure text code from codesys to aws. Instead of receiving {state {reported {data: 123}}} It display {state {reported {data: 123}}}\x00 \x00 \x00 \x00 \x00 \x00 \x00 Please help me solve this issues. how to remove \x00 ?
Last updated: 2023-12-06