Post by pmasip on Codesys Control for Raspberry Pi 4.10.0.0 - Raspberry Pi OS > 2023-12-05 CODESYS Forge talk (Post)
So none of the images from the 64bit archive work with any Codesys Control versions? I have tried the last Pi OS with every Codesys Control version and they don't work. I was wondering if there's any stable combination of versions.
Last updated: 2024-01-04

Post by peter-skokanek on Rpi install runtime licence on SP13 CODESYS Forge talk (Post)
Hi, I have an older project which has been running for years. Unfortunately I have to replace current Raspberry. I repplaced it by new rpi 3 with newest 32 bit Raspberry OS. I oredered a new runtime licence. When I try to activate it, the connection to target is interrupted immediatelly after press next button in the last step of instalation.
Last updated: 2024-01-08

Post by toby on Codesys Control Raspberry PI 4.10.0 - missing 'Update Raspberry PI' option CODESYS Forge talk (Post)
Hi, Mine is the same, both using v3.5 SP17 patch 6, and v3.5 SP19 patch 5 when using anything newer than v4.8.0 the same issue as above occurs. Checked the 'Customize' window in case it was hidden/disabled in there but couldn't find it. Thanks for the help on this. Toby
Last updated: 2024-01-09

Post by timvh on Sysfile inuts CODESYS Forge talk (Post)
To prevent ambiguous use of this enumeration value. Let's say another ENUM is available in your project or in another library which has an enumeration value AM_WRITE, then it is not clear which AM_WRITE you want to assign. By this qualified access to the SysFile.AM_WRITE, it is completely clear for the compiler.
Last updated: 2024-01-14

Post by hfelek on *SOURCEPOSITION* App = [Application] area=0, offset = 0 on default example CODESYS Forge talk (Post)
Hello, I am trying to run CmpTemplate component provided by Codesys for version 3.5.17. I call MyExternalFunction from the component but I get error as shown below. I see component is loaded successfully on runtime logs. I feel like I am missing something basically.
Last updated: 2024-01-15

Post by talhaali on Is a Reset possible for the CoDeSys soft PLC? CODESYS Forge talk (Post)
Hi, I have got a solution. Go to local disk C. (There will be an option View on top. Click View>Show>hidden items.) go to following path:C:\ProgramData\CODESYS\CODESYSControlWinV3x64 there will be one or two files. delete it and run control win again. issue will be resolved.
Last updated: 2024-01-18

Post by kevin123 on MessageKey for missing library dialog CODESYS Forge talk (Post)
Hi Martin, I got the messagekey of the "upgrade format warning dialog" with key:"<< No Key>>". (please refer to the attachment) Is that means i can't use system.prompt_answers["<<No Key>>"] = PromptResult.OK; to auto-answer 'OK' in this dialog? Is there any other way to auto-answer this dialog? Thanks!
Last updated: 2024-01-26

Post by rkohser on Python Script for Finding "Last saved with" Value CODESYS Forge talk (Post)
Hi jkilburn, I have the exact same issue and thought I would search a solution on this forum. I see you did not get any answer, did you find a solution on how to extract the last saved version of codesys from the project file ? Roland
Last updated: 2024-01-29

Post by eschwellinger on New Ladder Diagram conversion does not work due to missing features CODESYS Forge talk (Post)
The "remove unused" parameters have been added to 1.0 version as well as the "manual" removal of pins... also allowed "empty" inputs for blocks is in and the compile error described there should no longer occurs. Drag drop of variables is not yet implemented and I don't think the double-click feature yet either.
Last updated: 2024-01-29

Post by hagroth on v3.5 SP19 - Modbus TCP Devices - Channel Limit? CODESYS Forge talk (Post)
Today I was struggling with the same problem. in search for a solution i found this thread. Then i tried some things. It doesn't seem to be just a libraries' fault. In addition to 3.5.19, we also have a 3.5.18 version installed, the library versions of Modbus_TCP_Master and Modbus_TCP_Slave are the same, but more than 10 slave channels can be added in 3.5.18
Last updated: 2024-02-02

Post by mondinmr on Why SysPipeWindows is not implemented in RTE? CODESYS Forge talk (Post)
This library would be very useful for IPC communications. Using a UDP socket on localhost is unpredictable, as with slightly loaded machines it does not even guarantee packet delivery locally. Using TCP creates a lot of overhead. Message named pipes would be an excellent solution for Windows RTE. On Linux, since the release of the extension package, there is no issue, as it is sufficient to develop a component. However, although now 90% of our clients understand that Linux runtimes are better in every way compared to Windows RTE, especially from the security aspect (Not in kernel space) and the issues with Windows updates, 10% stubbornly insist (sometimes for trivial commercial reasons) on using Windows. Managing IPC with circular buffers in shared memory is quite ugly, or rather really ugly and unaesthetic. In the manuals, I saw the SysPipeWindows libraries, so I decided to test them, but unfortunately, I noticed that they are not implemented for RTE devices. Technically, I could try to open them as regular files, but SysFileOpen returns 16#27 or 16#39 depending on how I set the name (direction of the slashes). Here is the code to create shared memory and named pipes. Shared memory work great, named pipes no! #ifdef Q_OS_WIN32 SECURITY_ATTRIBUTES sa; SECURITY_DESCRIPTOR sd; InitializeSecurityDescriptor(&sd, SECURITY_DESCRIPTOR_REVISION); SetSecurityDescriptorDacl(&sd, TRUE, NULL, FALSE); sa.nLength = sizeof(SECURITY_ATTRIBUTES); sa.lpSecurityDescriptor = &sd; sa.bInheritHandle = FALSE; const wchar_t* name = L"Global\\ShmTest"; HANDLE hMapFile = CreateFileMapping( INVALID_HANDLE_VALUE, NULL, PAGE_READWRITE, 0, sizeof(SharedData), name); if (hMapFile == NULL) { qCritical("Error creating shared memory"); return 1; } data = static_cast<SharedData*>(MapViewOfFile(hMapFile, FILE_MAP_ALL_ACCESS, 0, 0, sizeof(SharedData))); if (data == NULL) { qCritical("Error mapping shared memory"); return 1; } HANDLE hPipe = CreateNamedPipe( TEXT("\\\\.\\pipe\\MyPipe"), PIPE_ACCESS_DUPLEX, PIPE_TYPE_MESSAGE | PIPE_READMODE_MESSAGE | PIPE_WAIT, PIPE_UNLIMITED_INSTANCES, 1024 * 1024, 1024 * 1024, NMPWAIT_USE_DEFAULT_WAIT, &sa); if (hPipe == INVALID_HANDLE_VALUE) { qCritical("Error creating named pipe"); return -1; } if (!ConnectNamedPipe(hPipe, NULL)) { qCritical("Error connecting to named pipe"); return -1; } checkPipe(hPipe); #endif
Last updated: 2024-02-02

Post by davidbo on i2c How does CODESYS handle exception or error messages. CODESYS Forge talk (Post)
For Raspberry Pi I have made a python script which regularly read a bulk of data over the ic2 from a device. Sometimes I get an Exception an IOError. I assume similar things can happen in CODESYS. So how does CODESYS handle that? Can I get any info about such an event?
Last updated: 2024-02-07

Post by ferrim on IEC 61499 CODESYS Forge talk (Post)
Hello otdeveloper, I am very interested in this topic. I have been dedicated to IEC 61499 for some time and I would like to understand if the time has come to adopt it in the real world of automation or if it will continue to fill up research papers only.
Last updated: 2024-02-09

Post by dkugler on Color Change for Symbols not working CODESYS Forge talk (Post)
to modify and change the color of this icons from symbols lib I placed it in a visu. After download to the device, I uploaded the SVG files and saved it local. Now I was able to modify them with inkscape and import it to my own imagepool in the project :-)
Last updated: 2024-02-13

Post by rmaas on Direct Pointers in IOMapping for EtherCAT with IoDrvEthercatLib.ETCSlave_Dia CODESYS Forge talk (Post)
Hi, Im not sure if this is what you mean, but i do succesfully use the IoDrvEthercatLib.ETCSlave.InputData and IoDrvEthercatLib.ETCSlave.OutputData to read from and write to beckhoff DI and DO cards. Very convenient as you can make an FB with an VAR_IN_OUT of type IoDrvEthercatLib.ETCSlave and only have to pass the slave reference... So i am not using .ETCSlave_Diag but .ETCSlave...
Last updated: 2024-02-13

Post by liepgp on Script for batch printing CODESYS Forge talk (Post)
I'm searching a way to print several projects to PDF, in order to correct student exercises. I'm able to open the printing dialog box using system.commands["print", "print"].execute(). But I can't find the prompt names in order to complete the printing with the dialogs Do you have any way to do that?
Last updated: 2024-02-13

Post by gurkan on OPCUA array max length? CODESYS Forge talk (Post)
We are using codesys 3.5.16.30 and we have a array with strings of length 5000. We are having issues subscribing to this variable from an OPCUA client. Is there any limit in the OPCUA Server in codesys for how long an array can be on the opcua server?
Last updated: 2024-02-16

Post by dav3 on Exception auf Raspberry, CMCommCycleTask Tainted CODESYS Forge talk (Post)
Hello, I don't really know what my problem was, but it's working for me at the moment. All i did was to change my code because of some REAL_TO_INT conversions, like i wrote above. And later a complete new Pi setup (because of 64x support with 4.10.0.0 now).
Last updated: 2024-02-16

Post by durstloescher on Library Documentation DocScripting CODESYS Forge talk (Post)
Hi, I am currently creating a documentation for our library with DocScripting. In the process, I noticed that Visu images are created before the merge and transform, i.e. "screenshots" of the different Visus. Unfortunately, these are not used in the later process (Merge/Transform). Is there a way to set it up so that they are found in the html file?
Last updated: 2024-02-19

Post by jmauer on Codesys 3.5 SP16 Modbus change port settings. CODESYS Forge talk (Post)
Hello, I'm coming to you today because I'm trying to make the baudrate and the slave number dynamic. I've tried the "updateComPortSettings" method on the slave device but it doesn't work and gives the "Modbus_COM_Port" an error. Can you tell me how you got this method to work? Thanks in advance for your help jΓ©rΓ©my
Last updated: 2024-02-20

Post by camilloo on Control for Linux SL on Ubuntu Core CODESYS Forge talk (Post)
Hello, Has anyone tried running CODESYS Linux on Ubuntu Core? I'm having problems installing the runtime. The connection to UC cannot be established. I used the instruction: https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_linux_public_key_authentification.html I can connect to UC using SSH (putty, shell). Codesys can't. Do any of you have an idea?
Last updated: 2024-02-24

Post by alexgooi on Init Array input on a method CODESYS Forge talk (Post)
Dear Forum, I would like to initialize an array input on a method. When I do this, I get the following error: "The type of ARRAY [1..2] OF BOOL cannot have a default value in this context." I attached a picture for more clarity. Is this simply not possible or is there a different way of tackling this problem? Thank you in advance
Last updated: 2024-02-26

Post by westcountryewe on ac_persistence not working when creating a Boot Application but works with a Direct Download to the PLC CODESYS Forge talk (Post)
I am using V3.5 SP18 Patch 5. I have noticed that when I Create a Boot Application from CODESYS, and upload this to my PLC via a USB stick the AC_Persistence does not work and none of my values that are in my PersistenceChannel are retained. However, if I connect direct to my PLC and I perform a direct download of my CODESYS program, my values that are in my PersistenceChannel are retained and work as they should. This makes me wonder if there are files that are missing when a Boot Application is created. I have tried taking a backup of my configuration files after performing a direct download, which gives me the plclog.zip folder, and appears to have the ac_persistence folder present within the file structure, however when I replace the plclogic.zip with the same folder that was created when I created a Boot Application, it still does not work but I wonder whether this is because the ac_persistence folder isn't stored in the correct location for reading. The .app and .crc files are embedded within the plclogic.zip folder, which obviously when uploading need to be standalone files in the root directory of the USB, so the intention there is clearly to extract the .app and .crc files and put them into the correct location within the USB. I wonder if it could be the same for the ac_persistence folder? I have tried moving it to different locations but none have worked. Has anybody else discovered a fix for this? I know the short-term solution is to do a direct download to the PLC but there are some logistical reasons why this isn't neccesarily the best solution for us.
Last updated: 2024-02-27

Post by jaspergain on SoftMotion Axes issue CODESYS Forge talk (Post)
Dear, We have an issue with SoftMotion and it's licensing. We don't use SoftMotion in this project. But a SoftMotion license is required by it. The License metrics tell's us there is a -1 Axes. Is there a way to reset this? Delete this? There was a MotionControl device in the project, but we have deleted this. But it stayed at -1. Thanks for you help.
Last updated: 2024-02-29

Post by jdjennings1962 on Is there any support for I2C on Raspberry Pi? CODESYS Forge talk (Post)
Hello, our team is able to use Raspberry Pi on CODESYS, but we purchased two peripherals that utilize I2C and we cannot figure out how to access these devices in CODESYS. But they are working using Python. Does anyone have a suggestion or an existing library that might help support this? Thank you, Jeff
Last updated: 2024-02-29