Visualisation generates "Unresolved reference"
CODESYS Forge
talk
(Thread)
Visualisation generates "Unresolved reference"
Last updated: 2026-02-02
Post by eschwellinger on cm4 runtime problem
CODESYS Forge
talk
(Post)
no - you need to update, smallest impakt is just to install the debiab package on target side. Nothing else ( no updates in CODESYS)
Last updated: 2026-02-02
cm4 runtime problem
CODESYS Forge
talk
(Thread)
cm4 runtime problem
Last updated: 2026-02-02
Post by nickpoon on SysProcessCreate stopped working after SP21?
CODESYS Forge
talk
(Post)
I'm going through the process of updating the CODESYS Project a machine to 3.5 SP21 (old version was 3.5 SP20). One function that stopped working when upgrading was SysProcessCreate. I need to run a .exe file that is located in C:\Program Files\MQTTStream. Some initial searching suggested that there are new security rules that prevent the SoftPLC from reading/writing files to outside of its Device folder (located here - C:\Windows\System32\config\systemprofile\AppData\Roaming\CODESYS\CODESYSControlWinV3x64\24FD6770) Relocating files helped fix my JSON file reader/writer functions (which were failing previously), but not the case for SysProcessCreate. I've even attempted to just run window's cmd.exe and with: pszCommandLine = 'cd /d C:\Windows\System32\config\systemprofile\AppData\Roaming\CODESYS\CODESYSControlWinV3x64\24FD6770\PlcLogic\MQTTStream & sift-proxy.exe --grpc_uri="https://grpc-api.siftstack.com" --api_key="xxxxxxxxxxxxxxxxxxx" mqtt-client --broker_ip=10.0.10.101 --broker_port=1883 --config_file="mqtt_telemetry_config.json" --username Plantd --password 1234 --stream_metrics --storage_path="sift-proxy-logs"' I have not been able to find a lot of documentation on this, and I suspect the new update may have created a bug for SysProcessCreate. Any help would be greatly appreciated
Last updated: 2026-02-02
Error, visualisation property handling, VISU_USEPROPERTYINFO
CODESYS Forge
talk
(Thread)
Error, visualisation property handling, VISU_USEPROPERTYINFO
Last updated: 2026-02-03
Post by gatto on Two licenses have to be installed forgot to enable one license
CODESYS Forge
talk
(Post)
Sorry, I've never used Raspy. Maybe someone else can help. From personal experience, I've had license activation issues, but it was caused by my company firewall, which was blocking traffic from the Codesys license server. So I found that the license was listed as activated on the server (and therefore used and no longer activable), but it wasn't present in the PLC. I solved the problem by using an unblocked internet connection when I needed to activate the purchased license ticket. Since then, the activation process has always worked, and I've never lost any licenses.
Last updated: 2026-02-03
Visualization 🇬🇧
CODESYS Forge
talk
(Discussion)
Realizing operator screens with CODESYS HMI, Targetvisu, Webvisu
Last updated: 2026-02-03
Post by arpat on Error, visualisation property handling, VISU_USEPROPERTYINFO
CODESYS Forge
talk
(Post)
For me going to Project -> Project Settings -> Visualisation -> check "Visible" and then check both "Activate property handling ..." and "Activate implicit checks ..." solved the problem.
Last updated: 2026-02-03
Two licenses have to be installed forgot to enable one license
CODESYS Forge
talk
(Thread)
Two licenses have to be installed forgot to enable one license
Last updated: 2026-02-03
Post by davidbo on Two licenses have to be installed forgot to enable one license
CODESYS Forge
talk
(Post)
Raspberry Pi MC Application based license: CODESYS Control Standard M CODESYS Visualization M (Could not be installed) CODESYS Control Standard M pops up with a dialog window where I can select 3 bundled licenses one of which is "Visu S" which I didn't select
Last updated: 2026-02-03
Post by winki on Error in licence activation
CODESYS Forge
talk
(Post)
Hello, Despite receiving an activation message after entering the license number, I don’t have any license installed on my gateway. I went to check in /var/opt/codesys/ and there is no License file. I searched the entire gateway for a .lic file and found no license. I’m really stuck—how can I fix this, please? When I am using the licence tools I got this picture: But nothing that have been activated. Loic,
Last updated: 2026-02-03
Error in licence activation
CODESYS Forge
talk
(Thread)
Error in licence activation
Last updated: 2026-02-03
Post by winki on Error in licence activation
CODESYS Forge
talk
(Post)
Hello, Despite receiving an activation message after entering the license number, I don’t have any license installed on my gateway. I went to check in /var/opt/codesys/ and there is no License file. I searched the entire gateway for a .lic file and found no license. I’m really stuck—how can I fix this, please? When I am using the licence tools I got this picture: But nothing that have been activated. Loic,
Last updated: 2026-02-03
Post by winki on Error in licence activation
CODESYS Forge
talk
(Post)
I am using Codesys Control for linux ARM64 SL. Installed with the SL deployment tool
Last updated: 2026-02-03
SysProcessCreate stopped working after SP21?
CODESYS Forge
talk
(Thread)
SysProcessCreate stopped working after SP21?
Last updated: 2026-02-03
IO Drive on C manual
CODESYS Forge
talk
(Thread)
IO Drive on C manual
Last updated: 2026-02-03
Post by russells on Codesys ControlWinV3x64 with EtherCat Slave
CODESYS Forge
talk
(Post)
Hi there I am running Codesys ControlWinV3x64 (Patch 4) on my laptop for demonstration purposes but I am unable to get connection to the EtherCAT master and slave device. This is the process that I have followed: * Installed NPCap. * Added the xml file for the SMC slave device to the Device Repository. * Activated Control Win SysTray x64 and selected Start PLC. * Scanned the network for the local device (my laptop). * Added an EtherCAT master to the project and scanned the EtherCAT master for the Network and then selected the correct network. * Selected "Scan for devices" to identify the connected I/O. * Add the SMC EtherCAT slave manually because I was unable to scan it in. * Selected "Scan for devices". I have followed the steps described above but I can't scan in the EtherCAT slave or connect to it. I thought this situation was unique to the EtherCAT slave but I have also tried the same for an EtherNet/IP slave using the Ethernet Adaptor and EtherNet/IP scanner and I am also unable to scan in the device or activate the EtherNet/IP network. Any assistance will be appreciated.
Last updated: 2026-02-04
Post by eschwellinger on Codesys ControlWinV3x64 with EtherCat Slave
CODESYS Forge
talk
(Post)
please check the plclog for more information. sounds like NPCap does not work.
Last updated: 7 days ago
Post by mrkm-dic on CODESYS: Combining Master Redundancy with EtherCAT Ring Topology – Is it Supported?
CODESYS Forge
talk
(Post)
Hello, I would like to ask whether it is technically supported (and practically achievable) to combine CODESYS Master Redundancy with EtherCAT ring (loop) redundancy in the same system. System setup CODESYS version: CODESYS 3.5.21.40 CODESYS Control SL for Weidmuller u-OS-4.12.2.0 Controllers (Masters): Weidmuller UC20-M4000 ×2, configured as Active / Standby using CODESYS redundancy EtherCAT Slaves: Weidmuller UR20-FBC-EC ×3, supporting EtherCAT ring / line break detection Topology: EtherCAT ring (loop) Main question Is it officially supported to use: ・CODESYS PLC/Master redundancy (Active/Standby) and ・EtherCAT ring topology (for cable redundancy) at the same time? Expected behavior Our expectation is: ・When the Active PLC fails, the Standby PLC becomes Active ・The Standby PLC then takes over the role of EtherCAT Master ・EtherCAT communication is re-established ・I/O control continues after reinitialization (a short interruption is acceptable; no strict bumpless requirement) We do not expect completely seamless / zero-cycle switchover, but we want to understand: ・Whether this combination is supported by design ・Or whether there are known limitations or restrictions when EtherCAT ring mode is used together with Master redundancy Clarification At this stage, the question is mainly about feasibility and support, not about a specific error message yet. Any official guidance, limitations, or real-world experience would be greatly appreciated. Thank you in advance.
Last updated: 6 days ago
Post by russells on Codesys ControlWinV3x64 with EtherCat Slave
CODESYS Forge
talk
(Post)
Much thanks. I reinstalled NPCap and it is now working. Much thanks.
Last updated: 6 days ago
Codesys ControlWinV3x64 with EtherCat Slave
CODESYS Forge
talk
(Thread)
Codesys ControlWinV3x64 with EtherCat Slave
Last updated: 6 days ago
Unable to compare projects containing alarm manager 4.5.0.0
CODESYS Forge
talk
(Thread)
Unable to compare projects containing alarm manager 4.5.0.0
Last updated: 6 days ago
Post by jslarbaletier on Unable to compare projects containing alarm manager 4.5.0.0
CODESYS Forge
talk
(Post)
Hi! I had the same issue and finally found a solution. Alarm Configuration was located in a “Visualisations” folder. I moved Alarm Configuration directly under “Application”, and the issue was resolved.
Last updated: 6 days ago
Post by timvh on CODESYS: Combining Master Redundancy with EtherCAT Ring Topology – Is it Supported?
CODESYS Forge
talk
(Post)
Yes, this works (at least we have it running with Wago PLC and Beckhoff I/O), but the concept works. You need 2 PLC's with at leat 3 network interfaces. And 2 switches (can be unmanaged). See the attached simple diagram for the solution.
Last updated: 6 days ago
Post by mrkm-dic on CODESYS: Combining Master Redundancy with EtherCAT Ring Topology – Is it Supported?
CODESYS Forge
talk
(Post)
Hi! thanks for reply. We tested the configuration you proposed as well; however, when the cable between the controller and the switch was disconnected, the Active and Standby roles were swapped. Did you observe the same behavior in your configuration using WAGO and Beckhoff?
Last updated: 5 days ago