Post by jonasz on Deploy LicenseServer for Linux SL CODESYS Forge talk (Post)
Hello, Basically, everything is clear to me. There's still the issue of a TimeProvider for an external device. This may be a stupid question, but I can't find this package. And of course, the question is, can the RPi machine be an external provider? Has anyone tested such a solution?
Last updated: 2025-11-18

Post by eschwellinger on Deploy LicenseServer for Linux SL CODESYS Forge talk (Post)
As I see from your logs I think the Timeprovider is not accurate enough in your case. Things to check - at the moment you run it on the same device? (for tesing purpose ok) I would set 127.0.0.0 as IP and set it not really to Core 0 ( many other stuff is there)
Last updated: 2025-11-20

Post by gseidel on SMC_ERROR SMC_CGR_INVALID_POSPERIOD CODESYS Forge talk (Post)
Hi blitz, that usually means that the modulo period, when converted to increments, is larger than 2^31. (The bus bandwidth is usually 2^32.) What is your "technical unit", do you program in angular degrees? And what is the modulo period? If you want you can post the drive configuration (screen shot of the "General" and "Scaling/Mapping" page). Best regards, Georg
Last updated: 2025-12-16

Post by willebro on "Distributed clocks are not synchronized, Rea time problem on hardware" ? CODESYS Forge talk (Post)
https://forge.codesys.com/forge/talk/Engineering/thread/632c29cb93/#8d94 The above comment is the best, but if you just want to see it work you can try disabling the distributed clock. It's not the right thing to do but it should resolve that error.
Last updated: 2025-12-16

Post by aniket-b on Scara3 kinematic robot error CODESYS Forge talk (Post)
Thanks Georg for responding. I have followed the suggestion mentioned in the real time problem. However, it does not solve the problem. The weird part is, the robot stops at the same position randomly and it does not stop when I increase the speed of the motion.
Last updated: 2025-12-23

Post by aniket-b on Scara3 kinematic robot error CODESYS Forge talk (Post)
Here I have attached the task monitor data. What is very weird is that I am using MC__MoveDirectAbsolute FB, when I choose Vel/ACC/Jerk Factor to 1.0 it run fine. It ran 10 hours without the issue. But I get the error randomly when I use factor as 0.5
Last updated: 2025-12-29

Post by blitz on Can't get SMC_SmoothPath to work CODESYS Forge talk (Post)
Hi @bertus I have a similar situation: just like in your case I can see that rounding works correctly only for the first element, additionally in my case on a path made of lines where I am testing this every second line is skipped. The interpolator jumps to every second iActObjectSourceNo.
Last updated: 2026-01-07

Post by eschwellinger on Deploy LicenseServer for Linux SL CODESYS Forge talk (Post)
for the package you net to install 32bit support(to have the native timprovider availble to deploy) sudo apt-get install libc6:i386 Then native Safeplc and native Safetimeprovider should be available to install. Raspi yes - but there is no official package available till now and you need have a rt_preemt patched kernel on the Pi, then it works like charm
Last updated: 2025-11-18

Post by eschwellinger on NO SIGNAL ON POWER_ON FOR STEPPER MOTOR CODESYS Forge talk (Post)
Hi, how should that work? You need to download the example project and you need that structure of the project and one of the additional hardware sets https://forge.codesys.com/drv/sm3raspistepper/home/Home/ L298N or A4988, DRV8880. Important to have no GPIO in the project and have this additional tasks.
Last updated: 2025-11-24

Post by yohayr on Access Violation sherd memory CODESYS Forge talk (Post)
Hi, once in a while I get an Access Violation exception in Sherd memory pointer. the strange thing is that I protect the pointer dereference and I get this exception 1 line after the protection. I added photos of the exception can someone tell me what is that about?
Last updated: 2025-11-25

Post by yohayr on Access Violation sherd memory CODESYS Forge talk (Post)
Hi, once in a while I get an Access Violation exception in Sherd memory pointer. the strange thing is that I protect the pointer dereference and I get this exception 1 line after the protection. I added photos of the exception can someone tell me what is that about?
Last updated: 2025-11-25

Post by osande on Trend/trace data CODESYS Forge talk (Post)
Ok, the problem is that the trend/trace system can't read function block instance data. The variables has to be stored directly under the program calling the FBs. Thus, FB variables to be trended/traced must be connected to variables declared in the program. Seems like a bug to me!
Last updated: 2026-03-13

Post by poliautomacao on Absolute movement controlled by an external encoder. CODESYS Forge talk (Post)
Georg, the encoder's actual position was -208 because I moved it manually for testing, but I managed to get it working. Your information is correct; there was a parameter error, Kp was at 0. After I adjusted it, it responded as expected. Thank you very much for your help.
Last updated: 2026-04-02

Post by alexgooi on No Bootproject possible CODESYS Forge talk (Post)
Hello Simon, Thank you for your response. The problem occurs after about 10 online changes, after this a full download is required, but that means that the installation is going down. Is it possible to enlarge the space reserved for online changes, so that the problem occurs after 100 online changes for example? Kind regards Alex
Last updated: 2026-04-14

Post by alexgooi on Network variable stops sending CODESYS Forge talk (Post)
Are you making use of structs in the NVL? In the past I had similar behavior (NVL stops sending) when I added something in the struct. if you are making use of structs makes sure that the structs are identical in both projects. If this is not the case, have you tried changing the port number to something different than 1202?
Last updated: 2026-04-29

Post by ilarioimi on Date Picker CODESYS Forge talk (Post)
Hello, I am new here and need some help. I have added the Date Picker to a visualization page. The date selection works, but the current day is not highlighted. The date and time are displayed correctly by the system, which is set by default to β€œVisuElems.Visu_DateTime.DisplayUTC:= FALSE;”. Is there some project setting or Visualization Manager setting that I am missing? Thank you. Ilario.
Last updated: 2026-01-14

Post by kambel on IO Drive on C manual CODESYS Forge talk (Post)
Hello, pls help!!! Is there a more detailed manual (for dummies) for writing your own IO drive device in C? Another question: how can I add diagnostics to the IEC IO Drive device so that a red triangle lights up in the project tree in the event of a malfunction?
Last updated: 2026-01-29

Post by davidbo on Two licenses have to be installed forgot to enable one license CODESYS Forge talk (Post)
I have to install "Basic M" and "Visualization M", but it seems that during installation of "Basic M" you have to enable "Visualization S" I assume if you here after want to install my "Visualization M". And I forgot to enable "Visualization S" How do I fix that?
Last updated: 2026-02-02

Post by pernockham on Unable to deploy "Control for Linux SL 4.18.0.0" CODESYS Forge talk (Post)
Ok, I think I understand. The problem is my language-setting being "swedish". I will check if I can switch to english. Update/confirmed. Change LANG to en_GB, this enabled the architechture to be correct and the control SL again to appear and to be possible to be updated. Thanks!
Last updated: 2026-02-23

Post by poliautomacao on Absolute movement controlled by an external encoder. CODESYS Forge talk (Post)
Hello, is it possible to perform an MC_MoveAbsolute movement, and have the servo move using an external encoder (freeEncoder)? In my application, I have slippage on the main shaft of the servo motor, and I would like to add an encoder to measure the actual position of the material.
Last updated: 2026-03-04

Post by noah on "Invalid Value" for Variables at Runtime CODESYS Forge talk (Post)
Hello, I also have the problem that suddenly all variables in my project were invalid and shown as "???" during runtime. Could you manage to fix the problem in the last 4,5 years ;) ? Because I tried everythin to fix it but nothing worked. I feel like maybe this is a bug. Thank you.
Last updated: 2026-03-09

Post by noah on "Invalid Value" for Variables at Runtime CODESYS Forge talk (Post)
Hello, I also have the problem that suddenly all variables in my project were invalid and shown as "???" during runtime. Could you manage to fix the problem in the last 4,5 years ;) ? Because I tried everythin to fix it but nothing worked. I feel like maybe this is a bug. Thank you.
Last updated: 2026-03-09

Post by gseidel on Absolute movement controlled by an external encoder. CODESYS Forge talk (Post)
Hi polyautomacao, hmm, did you tune the PD parameters as shown in the link I posted above? One thing that could cause the behavior are bad parameters. I also don't understand the screen shot: when you hold the encoder to 0, why is the actual position of the DrivePosControl -208? Best regards, Georg
Last updated: 2026-03-27

Post by reinier-geers on Network variable stops sending CODESYS Forge talk (Post)
I use network variables. But when i change the programm, it wil stop sending. Then is have to add or delete a variable. Then i will be compiled again and sends again. This problem wasw already in 9.20 but seems to be still in 21.0 . Is there a way to solve this ?
Last updated: 2026-04-20

Post by damian177 on Codesys and SMS in RPi CODESYS Forge talk (Post)
I tried initialize my GSM modem by write simple application in C, and GSM modem works, below used AT commands: AtChat: T : "AT" AtChat: F : "OK" AtChat: T : "AT+CMEE=1" AtChat: F : "OK" AtChat: T : "AT+CMGF=0" AtChat: F : "OK" AtChat: T : "AT+CGMI" AtChat: F : "WH_Ltd" AtChat: F : "WH_GM35" AtChat: F : "Revision: RDA BV5" AtChat: F : "OK" AtChat: T : "AT+CGMM" AtChat: F : "WH_GM35" AtChat: F : "OK" AtChat: T : "AT+CGMR" AtChat: F : "Revision: GM35-D_B5_R05_A01_D170914" AtChat: F : "OK" AtChat: T : "AT+CGSN" AtChat: F : "868221045990218" AtChat: F : "OK" AtChat: T : "AT+CNMI=2,1,0,1,0" AtChat: F : "OK" AtChat: T : "AT+CLIP=1" AtChat: F : "OK" AtChat: T : "AT+COPS?" AtChat: F : "+COPS: 0,2,\"26002\"" AtChat: F : "OK" operator name: "26002" AtChat: T : "AT+CREG?" AtChat: F : "+CREG: 1,1" AtChat: F : "OK" at+creg Modem is initialized I do not understand why Codesys SMS library send AT+CPIN? command ?